Loading...
HomeMy WebLinkAboutBLD2023-00675 - BLD CD Environmental Health Review - 6/23/2023 HS#107 ' <'''" '"t t-ta;, MASON COUNTY COMMUNITY SERVICES Permit No: +t� 7�1i ?� ' L� '2 PERMIT ASSISTANCE CENTER: �. •BUILDING•PLANNING•PUBLIC HEALTH•FIRE MARSHAL 2ill1117, , _ 615 W.Alder Street,Shelton,WA 98584 �'� :,qri Phone Shelton:(360)427-9670 ext.352•Fax:(360)427-7798 Phone Beltair.(360)275-4467•Phone Elma:(360)482-5269 BUILDING PERMIT APPLICATION PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: Lennar Northwest,Inc NAME: Lennar Northwest,Inc MAILING ADDRESS: 33455 6th ave S,Unit 1-B MAILING ADDRESS: 33455 6th ave S,Unit 1-B CITY: Federal Way STATE: WA ZIP: 98003 CITY:Federal Way STATE: WA ZIP: 98003 Z. PHONE#I: (253)294-1322 PHONE:(253)294-1322 CELL: (253)294-1322 r) PHONE#2: EMAIL: Sam.Martin@Lennar.com EMAIL: Sam.Martin@Lennar.com L&I REG# LENNANL783JO EXP. 03/18/24 C t`l PRIMARY CONTACT: OWNER❑ CONTRACTOR❑ OTHER tRI fi NAME Sam Martin,Agent for Lennar EMAIL Sam.Martin@Lennar.com MAILING ADDRESS 33455 6th ave S,Unit 1-B CITY Federal Way STATE WA ZIP 98003 t� PHONE (253)294-1322 CELL (253)294-1322 PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number) 12328-51-00107 ZONING cc LEGAL DESCRIPTION(Abbreviated) Olympic Ridge FIRE DISTRICT SITE ADDRESS CITY d61 NF Ridge Point Boulevard D. DIRECTIONS TO SITE ADDRESS V. IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES❑ NO® SNOW LOAD:25.00 psi IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply): SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ TYPE OF WORK: NEW® ADDITION❑ ALTERATION❑ REPAIR❑ OTHER USE OF STRUCTURE(Residence,Garage,Commercial Bldg,Etc.) New SFR using stock plan 1217 MF GL for Olympic Ridge Plan IS USE: PRIMARY❑ SEASONAL❑ NUMBER OF BEDROOMS 3 NUMBER OF BATHROOMS 2 HEATED STRUCTURE? YES(Whole Bldg)❑ YES(Part/si of Bldg)® NO❑ DESCRIBE WORK New Single Family Residence heated and garage unheated SQUARE FOOTAGE:(proposed) 1ST FLOOR 1185 sq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft. DECK sq.ft. COVERED DECK IA) sq.ft. STORAGE sq.ft. OTHER sq.ft. GARAGE 400 sq.ft. Attached® Detached❑ CARPORT sq.ft. Attached❑ Detached❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* ,j MAKE MODEL YEAR LENGTH WIDTH BEDROOMS BATHS SERIAL NUMBER 0 ENVIRONMENTAL HEALTH: SEWAGE/SEWER SOURCE: SEPTIC❑ SEWER® / NEW® EXISTING❑ PLUMBING IN STRUCTURE? YES® NO❑ If yes,attach completed Water Adequacy Form PERIMETER/FOUNDATION DRAINS PROPOSED? YES® NOD EXISTING SQ.FT. 1645 EXISTING BEDROOMS PROPOSED BEDROOMS , TOTAL BEDROOMS , OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or it construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON COUNTY CODE 14.08.42) x 'a. -7I rL— 03/20/2023 Signature of OWNER(Must be signed by the OWNER) Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL �-, PUBLIC HEALTH { 6P-31 BUILDING SETBACKS: TCE =INSTALL TEMP. CONST. ENTRANCE TRACT B PROPOSED FRONT: 10' SIDE: 5' REAR: 10' TSS =INSTALL TEMP. SOIL STOCKPILE ® S28'44'14"W 50.00' CONTOURS 7 _ --320 -_ - - 2 ~-322-- l - -.326~~ --- _ -328- - dil*° TSS r) `r) c9 o0 N N `r' BSBL--------' "' (nP) "R-5"Medium density residential district ' Front yard:10 feet. Side yard:5 feet for accessory structures and 5 feet for the dwelling unit. S! Street side yard:10 feet. PATIO i Rear yard:5 feet for accessory structures and 10 feet for the dwelling unit. 6' _ _ 9' Street rear yard:10 feet. 0 0 -o - _ 35' oO I EH APPROVED HS 107 I 14,,onea Wnom,,o,0623: HS 108 I PROPOSED I 0 SINGLE FAMILY o Public sewer and water I RESIDENCE o HS 106 'i (7) / r .d• EAVE_~1 BUILDING ` 1 217 M F 1 Z ENVELOPE 'L I G,RAGE L I 16' CONC. I g' Digitally �6' 'citi/DRIVEWAY PORCH �g' _ ScottRuedy signed b -o � by Scott SS STUB L' �'I Ruedy WALK n_ } f' 06/23/2023 o STORM- -_ oN `V STUB - o ^ - --330-— 6-4. :. . .J}} TCE 1-. . . • e N28144'14't 50.00' wM! --�! APPROVED . v -`------ - MASON COUNTY DCD PLANNING I SIDEWALK SCOTT►;UEDY,A(CP INSTALL SILT FENCE, WATER LINE EASEMENT SSMH .411.- .. .,,' STRAW WATTLE, OR AFN 1933608 FUNCTIONALLY EQUIVALENT NE RIDGE POINT BLVD SOIL AMENDMENT NOTE: LOT SIZE = 6,000 SF SEE BMP T5.13 "POST CONSTRUCTION IMPERVIOUS SOIL QUALITY AND DEPTH", WSDOE TOTAL IMPERVIOUS: 2,161 SF (36.0%) STORMWATER MANAGEMENT MANUAL ROOF: 1,813 SF FOR WESTERN WASHINGTON. DRIVEWAY: 306 SF FLAT WORK NOTE: WALK: 33 SF LOT COVERAGE = 1,813 SF (30.2%) FLAT WORK IS SHOWN FOR ILLUSTRATIVE PATIO: 9 SF (INCLUDES EAVES) PURPOSES ONLY. FINAL CONDITIONS MAY VARY. Job Number 0 ,\ `��, \\�\\\,,��\\\\\\\ LENNAR NORTHWEST INC. 21885 Scale 1"=20' Barghausen OLYMPIC RIDGE Sheet Drown DBriggs Consulting Engineers,Inc. HOMESITE 107 18215 72nd Avenue South PARCEL NO. 12328-51-00107 Kent,W 98032 1 of 1 Dote 3/23/23 425.251.6222 barghausen.com 461 NE RIDGE POINT BLVD. BELFAIR, WA File:P:\21000s\21885\lot\21865-0lympic Ridge-Plot Plons.dwg Plot Dote/Time:3/23/2023 9:25 AM DBRIGGS