Loading...
HomeMy WebLinkAboutSWG2022-00129 - SWG Application / Design - 6/14/2023 (2) M. ': MASON COUNTY 415 N 6TH STREET,SHELTON,WA 98584 SHELTON:360 427-9670,EXT 400 BELFAIR:360-275-4467,EXT 400 Public Health & Human Services ELMA:360-482-5269,EXT 400 FAX:360-427-7787 On-Site Sewage System Permit: SWG2022-00129 APPLICANT CONNOLE MARGOT &ZACHARY Phone: 360-556-5233 Address: 606 LILLY RD NE, APT 723 OLYMPIA, WA 98506 SEPTIC DESIGNER CINDY WAITE-Septic Designer Phone: 3607010205 Address: 80 E PICKERING LANE SHELTON, WA 98584 Site Address: 70 W Taffs Ter Primary Parcel Number: 420351490070 Permit Description: New SFR -2BR Nuwater Permit Submitted Date: 03/16/2022 Permit Issued Date: 05/02/2022 Issued By: Jeff Wilmoth Current Permit Fees Paid: $820.00 (additional fees may be required upon installation of system). Permit Expiration Date: 04/14/2025 (based on date of inspection) Permit Conditions: i 1 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 3 Drain field installation not to exceed designed upslope and downslope depth specified on design form. 4 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 5 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. 6 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsiteloss-inspection-request.php or call: 360-427-9670, extension 400. �.m_ . . I: a i OFFICIAL USE ONLY— MASON COUNTY PUBLIC HEALTH BAR RFCFIVED. eeWb / ONSITE SEWAGE SYSTEM APPLICATION AMWNTItLCCMU RECEIVEDM' o m 415 N 6th Street,(Bldg 81 Shelton WA,98584ECO"V 0 Co Shelton:360-427-9670 ext 400 Belfair. G 360-275-4467 ext 430 SWG c a _ cot a� 1 i 1r d c�J__ O Z 6 1 ,D ff`APPLICANT PHONE D D E �tivv l 3�o SSA 5,23, m •0 I I m MAILING ADDRESS STRFFT CITY STATE ZIP CODE r- D 0 _ 19 rS d/Ytic1o%� . V•A ' 27 z SITE ADDRESS-STREET.CITY,LIP COOL I CD 70 WEST TAFFS TERRACE SHELTON WA 98584 m NAJAF OF DESIGNER PRONE I� - C w ( 6 m.-t.f-e 36.0 R( 0 ;/ I N NAME OF INSTALLER PHONE 0 la CtIECK ALL APPLICABLE ITEMS DRINKING WATER SOURCE le NEW CONSTRUCTION 0 RV HOLDING TANK ONLY 0 PRIVATE INDIVIDUAL WELL CA I tl`W ❑ REPLACEMENT SYSTEM 0 INSTALLATION PERMIT ONLY 0 PRIVATE TWO-PARTY WEl 1. Z 1 VI ❑ TABLE 9 REPAIR SINGLE FAMILY 0 COMMUNITY/PUBLIC WATER SYSTEM ❑ TANK(S)ONLY ❑ COMMERCIAL SYSTEM NAME: ❑ UPGRADE TO EXISTING 0 OTHER: ._ BEDROOMS LOT SVE • ❑ EXISTING FAILURE "Record Drawing?squired ') 2 5 W 0 I S For aft Installations' L r DIRECTIONS TO SITE-BE SPECIFIC AND ADVISE OF ANY NEEDED INFORMATION FOR ACCESS(')i.IoiFsd yai-T 0 I SOUTH ON DEEGAN RD, LEFT ON WEST TAFFS TERRACE, UP HILL TO LOT ON I� RIGHT AT SIGN I c7 O lc, SITE MUST DE FLAGGED FROM MAIN ROAD AND TEST HOLES MUST BE FLAGGED WITH TEST HOLE NUMBERS --.161 -------- • --- — OFFICIAL USE ONLY BELOW THIS I INE . UPGRADE I FAILURE SOURCE(Tor Ie.porllnp mimosas) O VOLUNTARY 0 MAINTENANCE/PUMPING 0 BUILDING PERMIT OHOME SALE OCOMPLAINT 0OTHER•!_ -_ __ �'se J ..g1 INSPECTORSOIL LOGS COMMENTS/CONDITIONS 1 g _ —) - L 5 I .,,, o _ •D L 5 ..._ „...--iec--.0‘41- i Iiil SOIL CODES: V=VERY G=GRAVELLY 5=SAND L=LOAM SI=SILT C=CLAY E=EXTREMELY R=ROOTS IN r I. :NATURE DATE APPLICATION EXPIRATION DATE AP APPROVED BY DATE i�►, -iu —LI — ill— < LA -°-/ - TH - 0• BE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEBSITE REVISED 127/10IS Print- d ' om Mason County DMS Printed from Mason County DMS • IIMI DESIGN FORM—PAGE ONE Assessor's Parcel Number: 4 2 0 3 5 — 1 4 — 9 0 0 7 0 A design will be reviewed when 3 copies of each of the following are submitted: `itompleted design form that has been signed and dated. Scaled layout sketch,including all applicable items on checklist ''Scaled plot plan,including all applicable items on checklist. ''Cross-section sketch, including all applicable items on checklist. This form may be scanned and available for public view on the Mason County Web site.Maximum paper size: 11"X 17" PARCEL IDENTIFICATION Permit Number: SWG 2022-00129 Designer's Name: CINDY WAITE ' Applicant's Name: MARGOT&ZACHARY CONNOLE 360-701-0205 Designers Phone Number: Mailing Address: PO BOX 1995 80 E PICKERING LANE Designer's Address: OLYMPIA WA 98507 SHELTON WA 98584 City State Zip City DESIGN PARAMETERS State Zip Treatment Device ❑Glendon Biofilter 0 Sand Filter 0 Mound ❑Sand Lined Drainfield ❑Recirculating Filter,Type: ❑Aerobic Unit Make/Model ❑Disinfection Unit Make/Model Other: Drainfield Type ❑Gravity Io'Pressure LgTrench 0 Bed ❑Sub Surface Drip Septic Tank/Drainfield Specifications { h ;� VU L; � �, � La erals Number of Bedrooms 2 S• i ule/Class I SCHEDULE 40 Daily Flow: Operating Capacity 180 gpd L;+ JUN 0 9 Z0L3 i h;' Daily Flow: Design Flow 240 gpd D meter U 34 ft 1.25 in Septic Tank Capacity 1060 INFILITRATOR gal N :.8.1 3 Receiving Soil Type(1-6) 3 Separation 2 — ft Receiving Soil Appl. Rate .g gpd/ft' Orifices Required Primary Area 300 ft' Total Number of Orifices 27 Designed Primary Arca 306 2 ft Diameter 3/16 in Designed Reserve Area 300 ft, Spacing 48 Trench/Bed Width in 3 ft Manifold Trench/Bed Length 102 ft Schedule/Class SCHEDULE 40 Elevation Measurements Lei tl 1-2 ft Original Drainfield Area Slope 7 % to, et.jl 2 in New Slope, If Altered % i �fcrr 1, nifold -onfiguration used? EgYes 0 No Depth of Excavation Up-slope 18 in J?o.tea;, 1 from Original Grade �'.� ,d ��' 11 Transport Pipe Down-slope 15 in ice' ''�t �'1 (i�7 SCHEDULE 40 Designed Vertical Separation 12 • .e 1 'JJ"" t 120 ft Gravclless Chambers Required? ❑ Yes 0 No ❑ `ion*c *: ,WA' Gji� 11`. 2 Pump Required? '' in erYes 0 No X,%irri t ���;�� g and Pump Chamber EX��RES o5n0% Pump/Siphon Specifications Number of doses/day 6 Difference in Elevation Between Pump Shutoff and Uppermost Dose quantity 30 Orifice 5 ft gal Chamber Capacity 1060 INFILITRATOR gal Uppermost Orifice 0 Higher ❑ Lower than Pump Shutoff Pump controls: Please check those required. Capacity @ Total Pressure Head 15.93 gpm L(Timer Calculated Total Pressure Head 12.28 Ill lapse Meter 'Event Counter ft If Timer: Pump on , .. r5,41 f.` Comments y itDESIGNER AND INSTALLER TO MEET ON SITE PRIOR TO INSTALLATION A ., •RE S E EA- TO BE HELD AS SHALLOW ASc.POSSIBLE,GRAVEL BASED DRAINFIELD REQ ' �� I, 'NKS 0 7 7 MASON-COUNTY ENVIRONMENTAL HEALTH JBW DESIGN FORM—PAGE TWO Assessor's Parcel Number:4 2 0 3 5 — 1 4 -- 9 0 0 7 0 Permit Number: SWG DESIGN CHECKLISTS Scaled Plot Plan Scaled Layout Sketch El Test hole locations Cross-Section Sketch Pi Drainfield orientation and layout Reference depth from original grade: Soil logs C$ Trench/bed dimensions and RI 6d Property lines critical distances within layout Septic tank Gif WI Existing and proposed wells rigD-Box/Valve box locations Drainfield cover within 100 ft of property I�f Septic tank/pump chamber Reference depth from original grade gliv1 asurements to cuts, banks, and locations pie/ pLui and restrictive strata: fig Laterals,trench/bed,top and surface water and critical areas 521 Observation port location Location and orientation of bottom ai drain and absorption 66 Clean-out location 0 Curtain drain collector q components rid Manifold placement ❑ Sand augmentation Location and dimension of G� Orifice placement Other cross-section detail: IiiG� Lateral placement with distance Observation ports/clean-outs primary system and reserve area Buildings Yes No Eti to edge of bed IiiDirection of slope indicator lidAudible/visual al referenced Other Information AV ofa, 6d Waterlines Scale of'drawing shown on scale 0 Eilap ItDesign staked out Roads,easements,driveways, R 0 V E ❑ 0 Recorded Notices attached parking 0 0 Waiver(s)attached B1 North arrow and scale drawing JUL Q 3 2023 ❑ 0 Pump curve attached shown on scale bar ,,ps= ❑ ❑ Evaluation of failure MASON COUNTY ENVIRONMENTAL HEALTH Non-residential justification JBW ❑ ❑ Waste strength ❑ ❑ Flow DESIGN APPROVAL The undersigned designer must be ' ed by i taller at time of installation L(Yes 0 No Signs re of Designer 3 Dat l ts�,LA?,The undersigned has reviewed thi •esign on behalf of Mason County Public 1 ealth and determined it to be in compliance with state and loc. on-s e r gulations: ilk 7— 3- En it is tal l lealth Specialist 2-2_ Date CAUTION: DESIGN APPR I VAL IS VALID ONLY UNDER THE FOLLOWING CONDITION: The design is stamped "Approved" by Mason County Public Health. The Onsite Sewage Permit has not expired, the Permit Expiration Date is: ✓ Drainfield site conditions have not been altered to adversely affect conditions of design approval. g Please Note: The system must be installed by " )� unless prior authorization is obtained a certified installer, from Mason County Public Health. An Installation Fee is ref uired. This form may be scanned and available for public view on the Mason County Web site. Updated Date: 12/7/2015 • APPROV .: I, il,, • • iff 40.3 ` 1 ' e' 44 r\,; ;.j ; i..vTAL HEALTH (. 11 ti (A r ��i . i�VW Iso arc. d, tepl 1`,. �,, ' __. . . . M LICE DDCESIGNER �,+A� \`�� .�-:" • LS OSrIOr y--- =..-. (mod . .(€'1 . "9(r) . 1. RESIDENCE 2. GARRAGE ��_ f 3. 1060 INFILITRATOR SEPTIC TANK ' `� 4. 1060 INFILTRATOR PUMPE TANK • 5 EXISTING WELL f 6. WATER LINE ' • 7 TANSPORT LINE ' 8. CLEANOUTS(2) �� 9. ATTENUATION ZONE t `. `,3�� 10. AUDIO/ISUAL ALARM \l 1 i. VALVE BOX ` ' 12. PRIMARY, ;,- I .�.. ...,�. t f rt _ � t be 2 , L. f • • : . -,,\\V ___ -_ _n.-___ ___ __•-___ ............. _! �._.. . / .1/4(... �.,,r,, Ya' F. _. ._ _-- 11..E ti,�. � , I • • r. .F. _ ____...____ /.2...‘J. 1 ---.1.7._______. -- ...........ay • .4 ( ,. ...._....,............ ..... _......___....7 z 41, 1 i 2 ' -- - •• - . -. --- — - . .--11 ..,. j_,z4 ..,,e 0 Ijoilic • 44snAPPROVEA JUL 0 3 2023 • • cou • I /a ' I 2ca- :;-'i'..•, IV7V ENVIR0 NMENT Jaw At HEALTH 4h 4. 111 • L • if 4.i 0 CeN) 1 004 N \ th All.. 1 , 0 CIND - Alt • ISA LICENSED DESIGNE w, gs"cliT,,tok. lim.. IL Ilivio.m.. ', Lw.;,i..; .)..,•)• ,.___ 1 1 Lateral#; Length Length Orifice # Distance from Distance from end Length# ' # (Feet) (Inches) Spacing" Orifices feeder line of end of lateral 1 34 408 48 9 1 34 2 34 408 48 9 1 34 1 34 3 34 408 48 9 1 Total 102 27 102 TRANS LENGTH 60 GPM 15.93 K (2" SCHEDULEN 40) 284.5 FRICTION LOSS 0.2898666 Squirt 2 Elevation difference 10 TDH 12.289867 `�l `'k} u J )v/ /4/ NV N,__ ,ZZIK___ cv I • Z f ttCs 9 ,+ f ..........E.. ...; ilL c Fa„..4.0c. . ( k t / �;; v+ vile qH /� mai { 1 CI Dv WIfE n tiny" qu r LICEN DES.GN `� 'mil i. Z .:-'� LX.'IHLS U5n0, ,Ly vs AP!LRO3OED 2023 MASON COUNTY ENVIRONMENTAL HEALTH JBW \1 THREADED CAP OR PLUG • P `l. va_u(- — 6"PVC LAST ORIFICE; WITH ORIFICE SHIELDS IF ORIFICE ORIENTATION IS BACKFILL UPWARD MATERIAL \` �� lk���-� } �\j\j\j\ \ �j\�j\\ 6"_24" , \ �4° \\�\°ODO Fero§ ' ---- PRESSURE LATERAL oo0 0 0o0000o AS SPECIFIED PVC HOSE OR /\\ o 0 LONG SWEEP \% �G\ ELBOW \\ \\ DRAIN ROCK; 6"MIN. /, \ /� �� � LOW PIPE UNDISTURBED SOIL —/ 6"PVC WITH DRAIN HOLES; EXTEND TO BOTTOM OF GRAVEL TO MONITOR PONDING INFILTRATIVE SURFACE 114 or iv I1 MONITORING/CLEANOUT PORT •Trok, �. t (EXAMPLE) il.. C4 NNASM, TA 1 OV2 '`u,''-i i" -1'N 1,613 P P R 0 lit „„, ,, , `� 510 °h1/\ ` vv,p L CI 6ED DESICNEGt ���Z� `� A JUL 0 3 2023 IA\ le\ 10. Ilk iliW. ` MASON COUNTY ENVIRONMENTAL HEALTH EXPiRLS U5.10, JBW I14e/L46 .eV'. _ I RISER WITH LOCKING LID TO DRAINFIELD PRESSURE LATERALS A i A 1 1 ''� - I FLOW CONTROL VALVE :1 SLOTS AS REQUIRED : - .....° ) FLAP CHECK iI• .• . VALVE LONG SWEEP 90 ��� DEGREE ELBOW0 ��L AY 914 i�, �, . WASHED ROCK %�P s 2� �� DRAIN SUMP ark, �'. �,� r� 510 �� TRANSPORT PIPE FROM VI '/� LI CND D DE IGNBI�ITt, ' '`t,1/ PUMP CHAMBERmi. • 41 mom. I:Xc'ikLS U5'0. DRAINFIELD CONTROL BOX (SLOPING GROUND; MANIFOLD BELOW LATERALS) ``\,v APPRovV JUL 0 3 2023 b_ MASON COUNTY ENVIRONMENTAL HEALTH JBW PClni ff 1--9,, ' /,.-.. , :,,,,,f, . ,rr INFILTRATOR" ,,: . .. , N..- ,. i septic tanks I Features&Reset i• Strong injection molded polypropylene 1 construction • i • Lightweight plastic construction and h' r ' ` + inboard lifting lugs allow for easy �, ,—I de:;::::u2;reenuds ft!f' I i{ I • Int that ( J I (ii' interconnect with TWTM risers and pipe r(K•crKK�wit[K K (et lO o[ • riser solutions '� a1 N ti �' • Structurally reinforced access ports eliminate distortion during installation and pump-outs ", ' • Reinforced structural ribbing and fiberglass bulkheads offer additional -�. strength • Can be installed with 6"to 48" of cover The Infiltrator IM-1060 ,e lightweight strong and durable septic tank. • Can be pumped dry during iiP This watertight tank .-l:i•ri is offered with Infiltrator's line of custom-fit pump outs risers and heavy-du;;'ds. ,�v filtrator injection molded tanks provide a • Suitable for use as a septic tank, pump revolutionary impr.f en.;0..lastic septic tank design, offering long-term tank, or rainwater(non-potable)tank pi exceptional stren.,'0 anAsXJ.• !Si ightness. 6� � ���a�� �� • No special water filling requirements xi N,-)• z is#4. Inlet Side are necessary TANK CUTA '�':� 5�ooai8 I), et • The tank may be backfilled with suitable 1 ato n,` o ci v E Ai E '� • • i1• -� U" / - native soli. See installation instructions LICEN. ED SIGN:R y :+` { ,�( for guidance. r ,b J910 Partition baffle wall y l- i *• . HEAVY DUTY LID i. CUTAWAY I Reinforced 24"structural ocvsirt I Structural JUL 0 3 2023 �. bulkheads• MASON COUNT- F��IR��iMENTAI H t MID-SEAM CUTAWAY JBW EALTH y Reinforced water tight mid-seam �( Y gasketed connection p \ il, n, is ir Protecting the Environment with Innovative Wastewater Treatment Solutions N F I LT R ATO R water technologies / • IM-1060 General Specifications and Illustrations UF11NG STRAP UFTINGLUG Ri S(RCONNECTWN (TYPICAL) _(4TOEAL) (TYPICAL) The IM-1060 is an injection molded two piece mid-seam plastic tank.The IM-1060 Injection molded plastic design L�>]1 -�!1 1 1 I gralowl allows for a mid-seam joint that has precise dimensions A �i�'--y'F"��•li ■���'"',=°-�') for accepting an engineered EPDM gasket. Infiltrator's ,_ Q% �' I 1 t I■ ,r�Q%�rcl f gasket design utilizes technology from the water industry . , _U - ; ■ . b ! J be • %O . ' �Q T-II. 11 Sao' to deliver proven means of maintaining a watertight seal. ;__T-i. ', I E I I h ••: EXTERIOR The two-piece design is permanently fastened using a �'i=='"'-j�� II r:• a'"series of non-corrosive plastic alignment dowels and �,III( 1IIlip,r1 i �. Ill fir, LJIL J_ i_i. JV 44.VLJ`J��' locking seam clips.The IM-1060 is assembled and sold • through a network of certified Infiltrator distributors. :2A 13226;ExTER KIR LEN'eTH Must be backfilled and installed in accordance with TOP VIEW Infiltrator Water Technologies,Infiltrator IM-Series Septic OUTLET _ Tank General Installation Instructions and for shallow ground water conditions reference the Infiltrator IM- 1 Series Tank Buoyancy Control Guidance. $/&I , c Please visit www.infiltratorwater.com/images/pdf/ -„ uI1MI oa ManualsGuides/TANK01.pdf for the latest information. �i YIY +�( 111 I�E1 HEIGHT sEAM1xp 1I IM-1060 11�ING STRAP i �` fl_ (TYPICAL) 1 --- el.-_._.� Working Capacity 1094 gal(4141 L) Total Capacity 1287 gal(4872 L) ( END VIEW Airspace 16.5% Length 127"(3226 mat) ; D<11021 024(01 el ACCESS OPENINGS WITH LOCKING LIDS(21 PVC OR ABS 04(102)PVC OR WidthINLET TEE -10.21Mel FREEBOARD 62.2"(1580 mm) / ABS OUTLET TEE ar- Length-to-Width Ratio 2.3 to 1 1 INLET MY____1 1e.5% 1 , AIRSPACE Height 54.7"(1389 mm) 'FPEa 3:0 OUTLET 5 -- CODE n61 PER CODE) f (✓ <ODE Liquid Level 44"(1118 mat 440 I FIBERGLASS :1118} FIBERGLASS Invert Drop 3"(76 mm) SUPPORT --j uvulD SUP/TYPICAL (TYPICAL) I DEPTH (TYPICAL) Fiberglass Supports 2 MN BAFFLE WALL WHERE Compartments 1 or 2 ,,-----.—., REQuwED Maximum Burial Depth 48"(1P19 rnrn) -!�g POP f j VI P ii 0 v E Minimum Burial Depth 6"(152 mat) �4, Maximum Pipe Diameter 6"(152 mm) i�' �F�• 4 03 2023 Weight 320 lbs(145 yK TOP !,1/4/4R0, ' �c •9 ,, rANHALF I L' SON C(1 SKET S 0'f" <cl.- : z tt ^ ENVRp ,!� ,►. !%� TANK ,I NMENTAL HEALTH A'§' 51,,• 8 4 A , eaINTERIOR I,ll WM CUP tt C DY to 11 1� !�� LICE E 1 N861\ A �ly \� —Y �� \ �,\;v`�s TANK BOTTOM /} r. S is In 4\\ / 4 Business Park Road HALF y P.Q.Box 768 Old Saybrook.CT 06475 INFILTRATOR �� 9�4 3e• 869.57T-7901 MID-HEIGHT SEAM SECTION water technologies www.infiltratorswateccom J.S.Patents.4,759,881;5.017.041:5,155,488:5,336,017;5,401,11U;5,401,450;5,511,933;5,710,103;5,500,778;5,839,844 Canadian Patents:1,329,959,2,004,564 Other patents perking.Infitrator,Equalizer, Quick4,and SIdeWinder are registered trademarks of Infiltrator Water Technologies.Infilrator Is a reglslered trademark'n France.Infiltrator Water Technologies!s a registered Irademar7 in Mexico. Contour,Mao'-each ng,PolyTuff,ChamborSpacer,MultiPorl,Pos Lock,O,IikCut.QuickPley,SnapLOck and StraighlLock are trademarks of InPtrator Water Technologies. PdyLok is a trademark of PolyLok,Inc.TUF-TITE Is a registered trademark of fUF-TITE,INC.Ultra Rib Is a trademark of IPEX Inc. E)2016 Infiltrator Water Technologies,LLC.Al rights reserved.Printed in USAA IM02 1116 Contact Infiltrator Water Technologies' Technical Services Department for assistance at 1-800-221-4436 LbjjPuinps i.„ ;..,',. \IPump Specifications ` II I0A\ 250-Series Submersible I Sump / Effluent Pump tii � _ LITERS PER MINUTE 0 20 40 60 80 100 120 140 160 180 25 • 4 -4 - I t — 7 r 20 - • 6 L 5 15 t w lat 11.1 w z _ 4 iurd w —IJ Ct Q of 10 F = 3 i_N �° Pli,,,,,,ON,EV,„EL iv It.10- e 1% � 1 2�UL 0 3 2023IS '1-"'' ;s. e7 /� t1NTY EN ark, 'A# 10-- HEALTH O CINDi 1•11 A ' /r _ — J�� 5t 41,63- - 1 �or LI• . : I IGN R �1tt\ ��� IMF 01"T�''• `�� L,.:>�H,s 5 tu, �, — — -- \ 0 0 10 20 30 40 50 0 • GALLONS PER MINUTE 250 PI RI/I7/2018 LY'opynght 2018 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice able* Pumps Installation Notes Pressure Distribution System: 42035-14-90070 70 W Taffs Terrace 1. The prepared site plan is not a survey. It's the owner's responsibility to verify property lines, utility lines (water, sewer, power, phone and gas) prior to installation. 2. Extreme care to be taken when clearing, remove no top soil 3. Installer and designer to meet on site after clearing to layout drainfield laterals. 4. Concrete tanks required 5. Pump controls to be set at time of installation . 6. Install system during dry weather with acceptable soil conditions 7. The tanks may be moved as necessary to accommodate building requirements. Septic tank location must meet all required setbacks. 8. Keep wheeled vehicles off the drainfield area before, during and after installation. Tracked equipment only, 9. All ground, surface water and roof drains must be diverted away from the septic tanks and drainfield. Ensure the final grade slopes away from these areas and water doesn't collect on or around them. Use swales, berms, catch basin and tight lines, curtain drains, etc. to divert all waters. 10. Curtain drains can be no closer than 10' upgradient and 30' down gradient of the drainfield 11. Exposed restrictive layers, cuts, banks, etc. can be no closer than 50' downhill from the drainfield. 12. Install access risers on the septic tanks, valve box and ends of laterals. 13. Make sure septic tank risers are epoxied or caulked to cast in riser rings on,tank. 14. Lids must form a water and gas tight seal with the access risers 15. Install effluent filter specified in this design at the septic tank outlet. 16. This system must be installed by a Mason County Certified installer. 17. Self-install systems must meet Mason County procedures. or4 14 18. Deviation from this design without prior approval from the designer a r a�j'n County Health Department will make this design null and void. j' - , 19. This design was sized per Washington Administrative CodeWAC2; ;' operatinge o� �.•'.a�. The capacity is based on 45 gallons per day per capita wit ,„-,••01 0,1 s 13,3 bedroom. The minimum design flow per bedroom per day is th tol.eraliA. apaJ ,!/i, .f ninety gallons multiplied by 1.33. This results in a minimum d., .K twentyflo •���'�- �• ',,t d gallons per day. This creates a surge factor of 33% . ' c'"'Y� tic:•.;.• •.:���: :111•.e; fit,gallons per bedroom per day. , %'ll 20. Install laterals with contour of the ground "` "�"�� ` ��� � ��3 EXPIRES 0510, 21. Install trench bottoms level and always maintain a minimum of six inches into native soil 22. Install locator tape on top of all drainfield laterals. 23. Install threaded clean outs at the ends of all laterals (caps must extend to within six inches of finish grade and be in a valve box as shown on diagram. 24. Install audio/visual alarm 25. Filter fabric required over drain rock prior to backfillin tfacairRo the original grade, run the filter fabric at least 2 inch wn the trencw IjI. yeeEl \\� JUL 0 3 2023 MASON COUNTY ENVIRONMENTAL HEALTH JBW System Owner Responsibilities: 1. Operation and Maintenance is required by Washington State Department of Health and Mason County Health Department. 2. The septic tank and pump tank should be pumped every three to five years or as needed. 3. System owners are responsible for having maintenance performed annually. 4. System owners are responsible for responding to septic issues in a timely manner. 5. System owners shall not at any time change or alter settings in the control box. 6. System owner agrees to read and abide by information regarding their system in the User Manual provided by Mason County Public Health. 7. Keep the flow of sewage at or below the approved design operating capacity. 8. Keep waste strength at residential waste strength parameters. 9. Spread loads of laundry through the week. 10. Do not use excessive bleach or detergents with added whiteners. 11. Do not shower, do laundry and dishwasher at the same time 12. Antibiotics can kill or impair the biological process in the septic tank. 13. Leaky plumbing can hydraulic overload your on-site septic system. PPROVE .JUL 03ASONC OUNTY ENVIRONME2023 NTAL HE ALTH Q• -p LBW 1.0 � z LC' c2 5100418 p CINDY E WAITE LICENSED DESIGNER .i5 10, n/ V