COM2019-00120 Cancelled Furnace - COM Inspections - 6/10/2020
Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg. 8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us F 9-00120 MECH/PLUMB - COMMERCIAL ESCRIPTION: INSTALL REPLACEMENT FURNACE FOR ISSUED: 12/13/2019 LDING ESS: 600 NE ROESSEL RD BELFAIR EXPIRES: 06/10/2020 PARCEL: 123325000089 APPLICANT: PACIFIC NORTHWEST SALMON CENTER OWNER: PACIFIC NORTHWEST SALMON CENTER PO BOX 2169 PO BOX 2169 BELFAIR, WA 98528 BELFAIR, WA 98528 360.275.3575 GENERAL CONTRACTOR'S LICENSE: HCHC INC License: HOODCCH82101 PO BOX 2940 Expires: 09/21/2020 BELFAIR, WA 98528 360.777.7771 FEES: Paid Due Final Inspection $80.00 $0.00 Mechanical Fees $23.00 $0.00 Mechanical Base Fee $30.00 $0.00 State Fee-Commercial $25.00 $0.00 Totals : $158.00 $0.00 FIXTURES Qyt Mechanical Fixtures 1.0000 For each air-handling unit over 10,000 cfm (4719L/s) REQUIRED INSPECTIONS Mechanical/Plumbing Final Inspection CONDITIONS Printed by Ariane Paysse on:12/13/2019 10:24 AM Page 1 of 2 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg. 8 _ Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us MECH/PLUMB - COMMERCIAL COM2019-00120 * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. * The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency (ORCAA). It is unlawful for any person to cause or allow the demolition (or major renovation) of any structure unless all asbestos containing materials have been identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or operator has obtained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org * All furnace installations shall meet the minimum efficiencies set forth in the current edition of the Washington state energy code(WSEC). any portion of the mechanical system that is altered or replaced shall meet the minimum standards set forth in the WSEC and international mechanical code. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified here' or not. The granting of a permit does not presume to give authority to violate or cancel the provision f any er s regulating construction or the performance of construction. Issued Contractor or Authorized Agent: Date: a J Printed by:Ariane Paysse on:12/13/2019 10:24 AM Page 2 of 2 INSPECTION CARD Mason County :. / 615 W. Alder St. Bldg. 8, Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us PERMIT# COM2019-00120 PROJECT ADDRESS 600 NE ROESSEL RD BELFAIR, WA 98528 PARCEL# 123325000089 PROJECT DESCRIPTION Install replacement furnace for office building OWNER PACIFIC NORTHWEST SALMON CENTER ADDRESS PO BOX 2169 PHONE 360.275.3575 CONTRACTOR HCHC INC ADDRESS PO BOX 2940 PHONE 360.777,7771 CONTRACTOR LICENSE HOODCCH82101 LENDER INSPECTION INSP DATE Comments INSPECTION IN JDTE Comments Mechanical/Plumbing Final 12/12/2019 Rest UI t HVAC System Rooms In System Duct Systems Hot water piping Internal Loads HVAC System F I L E HVAC system COPY HVAC system name: System Heated: ® Yes ® No Cooled: TO BE KEPT ►N THE ® Yes No PARCEL FILE E Does this system serve all rooms in the home's conditioned space? 0 Yes ® No i I Duct system type: ® Ducted ® Ductless Engineered ventilation v Blower motor v Infiltration v Winter humidification v � DELETE � SAVE NEXT > Load Calculation Heating BTU Cooling BTU SHR CFM 41,961 18,378 1 928 Cooling Loads AEDExcursion aboveGradeWalls Amp ceilings floors windows I I i i Heating Loads aboveGradeWalls ceilings floors infiltration windows Wff I I �C httosJ/www r.nnlralr.rnm/rash d/ /9 12/12/2019 Rest UI t HVAC System Rooms In System Duct Systems Hot water piping Internal Loads MJ8 Report c = 10,000 - -- --------—-- ------- ti CO 5,000 — 0 8 9 10 11 12 13 14 15 16 17 18 19 20 —HTM —Average —Average'1.3 Privacy Policy I Terms of Use httos-//www.coolcalc.com/restui/ 2/2 Accuracy 5 F Ambient 32 F to 120 F Temperature Range Application Standard Efficient Gas Forced Air, High Efficacy Gas Forced Air, Oil Forced Air, Electric Forced Air, Hot water Fan Coil, Geothermal Heat Pump, Air to Air Heat Color White Cover Type UWP Current Rating 0.02 to 1 Amp (Heat), 0.02 to 0.05 (Fan) Dimensions 4-1/16" L x 4-1/16" W x 1-3/32" D Display Size 5.44 sq. in. Display Type Large Display, Soft Key Controls iu BE KEPT IN THE Electrical Honeywell UWP Mounting System Connection Details PARCEL FILE Electrical Rating 20 to 30 Vac Heat Current 0.02-1.0 A Inclusions/Features Thermostat, UWP mounting system, Installation (J-box) adaptor, Small decorative cover plate, screws and anchors, Installation Guide, User Guide, and 2 AA Batteries Mounting UWP Mounting System Operating Humidity 5 to 90% RH, Non-Condensing F1Lr= Range Operating 37 F to 102 F Temperature Power Method Battery or Hardwired Setting Heat- 40 F to 90 F; Cool 50 F to 99F Temperature Range Stages Up to 2 Heat/1 Cool Heat Pumps; Up to 1 Heat/1 Cool Conventional Systems Storage - 20 F to 120 F Temperature Supply Voltage 20 to 30 Vac Switch Position HEAT-OFF-COOL-AUTO-EM (System), AUTO-ON-CIRC-FOLLOW SCHEDULE (Fan) Switch Type Relay Temperature Rating 37 to 102 Deg F Terminal RC, R, C, W, W2, O/B, Y, G, K, L/A, E Designation Voltage Rating 20 to 30 VAC a _ Capacity ^ �49200 Btu/h (@ 240V) / 36900 Btu/h (@ 208V) i Capacity Power 14.4 kW (@ 240V) / 10.8 kW (@ 208V) Heater Amps per Circuit 40.0/20.0 (@ 240V) / 34.6/17.3 (@ 208V) Item Heater Number of Circuits/Phases 2/1 aVAA 1�kN`���1 TO BE KEPT IN THE PARCEL FILE Cooling Capacity 42000 Btu/h Crated Dimensions 52-3/4" H x 27-1/2" W x 25-1/2" D Drain Conn. Size 3/4" NPT F.L. Amps 4.3 Face Area 4.59 sq. ft. Gas Line Size 7/8" i Indoor Coil Type Plate Fin Liquid Line Size 3/8" Rated Voltage 208-230/1/60 Refrigerant R-410A Refrigerant Control TXV Refrigerant Line Connections Brazed Return Opening 21.75" x 18.75" Rows - F.P.1. 4 - 14 Shipping Weight 155 Ibs Supply Opening 21.5" x 12.15" Tube Size 3/8" Uncrated Dimensions 51-3/8" H x 23-1/2" W x 21-1/8" D Weight + 144lbs %�- HC Call Today. HEATING& . . 1 COOLING (360)777-7771 Customer's Name: Job Address: Date: Salmon Center 12/13/2019 Customer's Billing Address: City,State,Zip: Customer#: Home Phone: Mobile Phone: Email(s): Job#: Why Choose Us? • A Company You Can Trust.We are a locally owned and operated . Professional Service&Maintenance.Our service and business that has been meeting the comfort needs of our maintenance programs keep your equipment running at peak community for years-let our nationally recognized name-brand efficiency-to provide better comfort and healthier air while we lower equipment and air quality products meet your needs too. your utility bills and help your equipment last longer. Duality Installation.Our professional,nationally certified and . Affordable Pricing&Financing.We offer great prices and our factory-trained technicians have years of installation and service high-efficiency equipment will cut your utility bills.Our financing experience-we'll get your job done right the first time. programs can be tailored to meet every budget. Option 1 F r Trane M-Series TEM6AOC42H41 SB Air Handler 42,000 BTUs 10 Year Parts Warranty 1 Year Labor Warranty R 10 Year Heat Exchanger Warranty • ;; BAYHTR1510BRKC Electric Heater • 10 kW Accessories Thermostat-Honeywell T6 Pro Thermostat Option 1 Total Investment Total:$4,363 Estimated Payment:$53.23 Payment:/mo.Min Monthly Customer Acceptance: Date: Company Approval: Date: Company Representative: HC Heating&Cooling ., admin@hcservice.com, (360)777-7771 Notes All necessary materials and supplies to complete installation are included. HC retains title to all equipment&materials until outstanding balance is paid in full. 'Proposal excludes sales tax December 13, 2019 9:24:50 AM Page 1 of 2 Terms&Conditions 1.This proposal may be withdrawn if not accepted within 30 days. 2.Financing is subject to approval by financing company. 3.Contractor provides trained,qualified and licensed technicians. 4.All Labor&Warranty work is performed during the contractor's normal business hours. 5.Materials furnished by contractor include a one-year limited warranty unless otherwise noted.Limited warranty does not cover existing filters,coils, line-sets,electrical power lines and connections,drainage,refrigerant loss or contamination. 6.Contractor is not liable for any pre-existing conditions or any work performed by customer or third parties. December 13, 2019 9:24:50 AM Page 2 of 2 } i MWEg FILE COPY Product Data TO BE KEPT IN THE Convertible Air Handlers PARCEL FILE 1-1 /2 — 5 Ton TEM6AOB24H21 SB TEM6AOB3OH21 SB TEM6AOC36H31SB e TEM6AOC42H41 SB TEM6AOC48H41SB TEM6AOD48H41SB D�TEM6AOC6OH51 SB o TEM6AOD6OH51SB Q D The TEM6 series air handler is designed for installation in a closet, utility room,alcove,basement,crawlspace or attic. These versatile units are applicable to air conditioning and heat pump applications.Several models are available to meet the specific requirements of the outdoor equipment.Field installed electric resistance heaters are available. March 2018 22-1907-1 G-EN Ingersoll Rand rJINNE' Table of Contents Featuresand Benefits. . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 OptionalEquipment. . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Product Specifications. . . . . . . . . . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Heater Pressure Drop Table . . . . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Subcooling Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Subcooling Adjustment for TEM6AOC48H41 &TEM6AOC601-151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Performance and Electrical Data . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Minimum Airflow CFM . . . . . . . . . . .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 ElectricalData . . . . . . . . . . . . . . . . . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 FieldWiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 TEM Convertibility. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 TEM6 Air Handler Dimensional Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 OutlineDrawing . . . . . . . . . . . . . . . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 2 22-1907-1 G-EN TRAA/E' Features and Benefits • Painted metal cabinet with captured foil face insulation • 2%or less air leakage • R-4.2 Insulating Value • Multi-Position UP/Down Flow,Horizontal Left/Right • ALL Aluminum Coil with Enhanced Patented Coil Fin • Electric Heaters with polarized plug connections(sold as accessory) • R-410A Thermal Expansion Valve • Variable Speed ECM Motor • Low Voltage Pigtail Connections • Draw Through Design • Horizontal Drain Pan • Single Color • Fused 24V Power • 3 year warranty • 10-year warranty registered • Optional extended warranty available Optional Equipment Accessory Number Description Fits Model BAYHTR1504BRKC Electric Heater,4KW,Breaker,24V Control,1 Ph TEM6AOB24-TEM6AOD60 BAYHTR1504LUGB Electric Heater,4KW,Lug,24V Control,1 Ph TEM6AOB24-TEM6AOD60 BAYHTR1505BRKC Electric Heater,5KW,Breaker,24V Control,1 Ph TEM6AOB24-TEM6AOD60 BAYHTR1505LUGB Electric Heater,5KW,Lug,24V Control,1 Ph TEM6AOB24-TEM6AOD60 BAYHTR1508BRKC Electric Heater,8KW,Breaker,24V Control,1 Ph TEM6AOB24-TEM6AOD60 BAYHTR1508LUGB Electric Heater,8KW,Lug,24V Control,1 Ph TEM6AOB24-TEM6AOD60 BAYHTR1510BRKC Electric Heater,1OKW,Breaker,24V Control,1 Ph TEM6AOB24-TEM6AOD60 BAYHTR1510LUGB Electric Heater,10KW,Lug,24V Control,1 Ph TEWAOB24-TEM6AOD60 BAYHTR1516BRKA Electric Heater,15KW,Breaker,24V Control,1 Ph TEWAOB24-TEM6AOD60 BAYHTR3510LUGC Electric Heater,1OKW,Lug,24V Control,3 Ph TEM6AOB24-TEM6AOD60 BAYHTR3515LUGC Electric Heater,15KW,Lug,24V Control,3Ph TEM6AOB24-TEM6AOD60 BAYHTR1522BRKA Electric Heater,20KW,Breaker,24V Control,1 Ph TEM6AOB36-TEM6AOD60 BAYHTR1523BRKA Electric Heater,20KW,Breaker,24V Control,1 Ph TEM6AOB36-TEM6AOD60 BAYHTR1525BRKA Electric Heater,25KW,Breaker,24V Control,1 Ph TEM6AOB48-TEM6AOD60 BAYTEMSPFGIA/B Supply Duct Flange Kit TEM6AOB24-TEM6AOD60 BAYSPEKT201A Single Point Power Entry Kit TEWAOB24-TEM6AOD60 TAYBASE185 Air Handler Downflow Sub-Bases TEM6AOB24-TEM6AOB30 TAYBASE235(TAYBASE 100) Air Handler Downflow Sub-Bases TEWAOC36-TEM6AOC42 TAYBASE260 Air Handler Downflow Sub-Bases TEM6AOD48-TEWAOD60 BAY6TXV2442A R-22 TXV Conversion Kit TEM6AOB24-TEM6AOC42 BAY6TXV4860A R-22 TXV Conversion Kit TEM6A0048-TEM6AOD60 BAYATXV6161C R-22 TXV Conversion Kit TEM6A0C48-TEM6A0C60 BAYSF1185AAA Slim Fit Filter Box 18.51, BAYSF1235AAA Slim Fit Filter Box 23.5" BAYSF1265AAA Slim Fit Filter Box 26.5" 22-1907-1 G-EN 3 TRWE' Product Specifications MODEL TEM6A0B24H21SB TEM6AOB3OH21SB TEM6AOC36H31SB RATED VOLTS/PH/HZ 208-230/1/60 208-230/1/60 208-230/1/60 RATINGSW See 0.D.Specifications See O.D.Specifications See O.D.Specifications INDOOR COIL—Type Plate Fin Plate Fin Plate Fin Rows—F.P.I. 4-14 4-14 4-14 Face Area(sq.ft.) 3.44 3.44 4.59 Tube Size(in.) 3/8 3/8 3/8 Refrigerant Control TXV TXV TX/ Drain Conn.Size(in.)(b) 3/4 NPT 3/4 NPT 3/4 NPT DUCT CONNECTIONS See Outline Drawing See Outline Drawing See Outline Drawing INDOOR FAN—Type Centrifugal Centrifugal Centrifugal Diameter-Width(In.) 11X 8 1IX 8 11 X 8 No.Used 1 1 1 Drive-No.Speeds Direct-16 Direct-16 Direct-16 CFM vs.in.w.g. See Fan Performance Table See Fan Performance Table See Fan Performance Table No.Motors—H.P. 1-1/3 1-1/2 1-1/2 Motor Speed R.P.M. Variable Variable Variable Volts/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 F.L.Amps 2.5 4.3 4.3 FILTER Filter Furnished?W No No No REFRIGERANT R-410A R-410A R-410A Ref.Line Connections Brazed Brazed Brazed Coupling or Conn.Size—in.Gas 3/4 3/4 7/8 Coupling or Conn.Size—in.Uq. 3/8 3/8 3/8 DIMENSIONS HxWxD HxWxD HxWxD Crated(In.) 48-1/4 x 22-1/2 x 25-1/2 48-1/4 x 22-1/2 x 25-1/2 52-3/4 x 27-1/2 x 25-1/2 Uncrated 46-3/4 x 18-1/2 x 21-1/8 46-3/4 x 18-1/2 x 21-1/8 51-3/8 x 23-1/2 x 21-1/8 WEIGHT Shipping(Lbs.)/Net(Lbs.) 126/117 126/117 155/144 (a) These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps(AHRI STANDARD 210/240).Refer to the Split System Outdoor Unit Product Data Guides for performance data. (b) 3/4"Male Plastic Pipe(Ref:ASTM 1785-76) (0 Remote filter required. 4 22-1907-1 G-EN MANE Product Specifications MODEL TEM6AOC42H41SB TEM6AOC48H41SB TEM6AOC60H51SB RATED VOLTS/PH/HZ 208-230/1/60 208-230/1/60 208-230/1/60 RATINGS(a) See O.D.Specifications See O.D.Specifications See O.D.Specifications INDOOR COIL—Type Plate Fin Plate Fin Plate Fin Rows—F.P.I. 4-14 3-16 3-16 Face Area(sq.ft.) 4.59 7.9 7.9 Tube Size(in.) 3/8 3/8 3/8 Refrigerant Control TXV TXV TXV Drain Conn.Size(in.)(b) 3/4 NPT 3/4 NPT 3/4 NPT DUCT CONNECTIONS See Outline Drawing See Outline Drawing See Outline Drawing INDOOR FAN—Type Centrifugal Centrifugal Centrifugal Diameter-Width(In.) 11 X 8 11 X it 11 X 11 No.Used 1 1 1 Drive-No.Speeds Direct-16 Direct-16 Direct-16 CFM vs.in.w.g. See Fan PerforrnanceTable See Fan Performance Table See Fan Performance Table No.Motors—H.P. 1-1/2 1-3/4 1-3/4 Motor Speed R.P.M. Variable Variable Variable Volts/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 F.L.Amps 4.3 6.8 6.8 FILTER Filter Furnished?W No No No REFRIGERANT R-410A R-410A R-410A Ref.Line Connections Brazed Brazed Brazed Coupling or Conn.Size—in.Gas 7/8 7/8 7/8 Coupling or Conn.Size—in.Liq. 3/8 3/8 3/8 DIMENSIONS HxWxD HxWxD HxWxD Crated(In.) 52-3/4 x 27-1/2 x 25-1/2 57-1/8 x 27-1/2 x 25-1/2 57-1/8 x 27-1/2 x 25-1/2 Uncrated 51-3/8 x 23-1/2 x 21-1/8 55-3/4 x 23-1/2 x 21-1/8 55-3/4 x 23-1/2 x 21-1/8 WEIGHT Shipping(Lbs.)/Net(Lbs.) 155/144 185/174 185/174 (_) These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps(AHRI STANDARD 210/240).Refer to the Split System Outdoor Unit Product Data Guides for performance data. (b) 3/4"Male Plastic Pipe(Ref:ASTM 1785-76) W Remote filter required. 22-1907-1 G-EN 5 Product Specifications MODEL TEM6AOD48H41SB TEM6AOD60H51SB RATED VOLTS/PH/HZ 208-230/1/60 208-230/1/60 RATINGSW See O.D.Specifications See O.D.Specifications INDOOR COIL—Type Plate Fin Plate Fin Rows—F.P.I. 4-16 4-16 Face Area(sq.ft.) 6.47 6.47 Tube Size(in.) 3/8 3/8 Refrigerant Control TXV TX/ Drain Conn.Size(in.)(b) 3/4 NPT 3/4 NPT DUCT CONNECTIONS See Outline Drawing See Outline Drawing INDOOR FAN—Type Centrifugal Centrifugal Diameter-Width(In.) 11 X 11 i1 X 11 No.Used 1 1 Drive-No.Speeds Direct-16 Direct-16 CFM vs.in.w.g. See Fan Performance Table See Fan Performance Table No.Motors—H.P. 1-3/4 1-3/4 Motor Speed R.P.M. Variable Variable Volts/Ph/Hz 208-230/1/60 208-230/1/60 F.L.Amps 6.8 6.8 FILTER Filter Furnished?W No No REFRIGERANT R-410A R-410A Ref.Line Connections Brazed Brazed Coupling or Conn.Size—in.Gas 7/8 7/8 Coupling or Conn.Size—in.Uq. 3/8 3/8 DIMENSIONS HxWxD HxWxD Crated(In.) 55-3/8 x 30-1/2 x 25-1/2 55-3/8 x 30-1/2 x 25-1/2 Uncrated 53-7/8 x 26-1/2 x 21-1/8 53-7/8 x 26-1/2 x 21-1/8 WEIGHT Shipping(Lbs.)/Net(Lbs.) 181/168 181/168 (a) These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps(AHRI STANDARD 210/240).Refer to the Split System Outdoor Unit Product Data Guides for performance data. (b) 3/4"Male Plastic Pipe(Ref:ASTM 1785-76) W Remote filter required. 6 22-1907-1 G-EN TRAIVE° Heater Pressure Drop Table Number of Racks Heater Racks Airflow 1 2 3 4 Heater Model No.of Racks CFM Air Pressure Drop-Inches W.G. BAYHTRI504 1 1800 0.02 0.04 0.06 0.14 BAYHTR1505 1 1700 0.02 0.04 0.06 0.14 BAYHTR1508 2 1600 0.02 0.04 0.06 0.13 BAYHTR1510 2 1500 0.02 0.04 0.06 0.12 BAYHTR1516 3 1400 0.02 0.04 0.06 0.12 BAYHTR1517 3 1300 0.02 0.04 0.05 0.11 BAYHTR3510 3 1200 0.01 0.04 0.05 0.10 BAYHTR3517 3 1100 0.01 0.03 0.05 0.09 BAYHTR3515 3 1000 0.01 0.03 0.04 0.09 BAYHTR1522 4 900 0.01 0.03 0.04 0.08 BAYHTRIS23 4 800 0.01 0.03 BAYHTRI525 4 700 0.01 0.02 600 0.01 0.02 Subcooling Adjustment System Matched with: Indoor Unit Model No. Outdoor Model No. Subcooling 16 SEER HP-2 ton TEM6AOC36H31 4TWR6024H1000A 13 Degrees 4TWX602411 1000A 4A61-160241-11000A 15 SEER HP-2 ton TEM6AOB24H21 4TWR5024G1000A 14 Degrees TEM6A013301-121 4A6H5024G1000A 15 SEER HP-3 ton TE1V16A0B30H21 4TWR5036G1000A 14 Degrees TEM6AOC36H31 4A6H5036G1000A TEM6AOC42H41 All other matches must be charged per the nameplate charging instructions Subcooling Adjustment for TEM6AOC48H41 & TEM6AOC6OH51 Sub-Cooling Charge Specification For AHRI Rated Performance OD Equipment Up Flow/Horizontal Down Flow AC UNIT OD Name Plate OD Name Plate HP UNIT<_3.5 Tons OD Name Plate OD Name Plate +4 Degrees HP UNIT=4 and 5 Tons OD Name Plate OD Name Plate 22-1907-1 G-EN 7 d �i•' V C O v c o 0)T Z c iT T N N ! O t4 O CD 0 W N N �-' O 1'� CD v o u n V�p A (n in Z�� (N m0 vmv D (D V'mA D Z c c Z Z Z Z In -n •* Z Z Z Z L, T v) O r 2 O r 2 O r 2 O r mm p O r m O r 2 O r 2 O r W3 p 3 O 3 O 3 O m ° 3 p 3 O 3 O Ll 3 O m m D = D = D = D z O D = D = D = D Z p 3 r r r r Gl m r r r r C) Ot W W A W W A A W A A W VI D m 0 W W W W W A W W A A W (n D O O A N W tD to t0 A tD to A t0 m" W �+ CO A O W tD A In O to W O Vl V 07 O W W N A .� O O W O O lD 0 W I•+ �.+ W m,'L7 o n o n o n o n o n o n o n o n o n o non n a m o n o n o n o n o n o n o n o n o n o n o n T o -n T -n T T T T T T T T Z p O 3 T T T m T T T -n T n T r = 0 3 3 3 3 3 3 3 3 3 3 3 W n 3 3 3 3 3 3 3 3 3 3 3 Z O N 0 W CD G7:E N O O (A 2 � O O zzzO O O zzz NW n -nO zzzO O O zzz C O r v m o Z v a c 0 O O O O O O O o O O O cn 1 O O O O O O O O O O O Ln VC) -n -n -n -nZ Z Z Z Z Z N Z -n -n -nT T Z Z Z Z Z Z N G = a n " = r Ln O O p O O p o O p O O C�C m n O O Ln p O O p O O p O O C�C m �l -nZ -n -n Z T -nZ -n T G A r -n -nZ -nT Z T -nZ -nT G �l n -n -n -n -n -nT W O -n -n -nT -n -n -nT w m C C T O O p O O p O O p O O p w m O p O O p O O p O O p U mm -nZ -n -nZ -n -nZ -n -nZ A T -n X -nZ -n -nZ T T Z T T Z A 3 O a 3 n �n �n �n �n n n n n n �n n 0CX Z �n �n �n �n �n �n �n �nZEn �n �n 0C� T T QJ T n m °+T 0) m °+m °:T w,T w,T w,T °+T G r n U T W M K T W T T T w T w T °;T O) -n of T O) m G T 3 3 3 3 3 3 3 3 3 3 3 m m 3 3 3 3 3 3 3 3 3 3 3 m r m N )n in m in in )n in in )n p Z N u+ in )n in N )n v, )n N � n O 0 �+-O �+O N �+tD Co �+ID �+ V O V V O to p �+t0 r t0 �+O r 07 V �+W �+V 0+ O+ to r CD Ln F, W to N 0 V tD N m O w W O V p7 A N 00 07 l0 r W t+f+ V Ot N In In W O O D O OD M W F+ W Z 1 A O W W 0� F+to In 0l V O r A In m O tD )-'' m w ID W N W O 10 N N to 4 A tD N V ~A � N xx M N r tD N N tD �+W N t0 tO V f+V -0+ D7 In p •� 0 r f+tD N t0 Co �+V r O V r Ot �-Ot to d - 07 l0 V N O T J �V V O N tD C+A O 0+ V - m tD 0 V A N V V Q\ N A V m A tD �V H m �O V tp � m m M.4 07 O A w N O N O m N tD N m O W O tD to O— w Z = 40 N V W w N r w tD V V In CO Ln N In W O p V W A D D ZO CD Vt0 lD N p N W N 00 .1 ON Ln c N N ID N ID MOD m - r T In ApO Ln ON V -0) OtDr w NWtt DWWAAAAO p D mO O -O to O O O tD N nWWNtor V tD WN Wn rW 01 00 lfl 0 Arn a a v m m m z O m W O W t0 W p W tD N Co W t0 NOD N V N lP Ot f+to p (n W p N t0 N tD NCO N O N 07 N V r 0+ Ot F+In �+A p In (fi A r 0 Ot O O W O W O V UI tD N W O A V r A 0 - (n N tD W tD C, A W -0 V A r W W r CO r to t+ W N (n '+ O V 07 to NUl to 0+ W W O A W A W In 00 In 00 O Ot N V C T O V m r V N O 1-+t+ A(n O tr N A N r lJ7 V O In V C 1 � m � m A 0 W to W t0 W W N V w O N m N m N W N In r A p W tD W O W W N V N 01 IM V N Cl, N Ln N to �+A �+W N O w W In F-` N V 00 Ln N Ot CO O N V A N O V V O l0 A O O O A O)N A W lD U1 A 01 t+V r'V 00 CO N tD O 0 OtO ID�+ W O InN OO A W F+lD W A OOt tDN Ln V V A W WA W V -M Or Ow (n�+ too tr 01 V O Q� O TRINE' Performance and Electrical Data Table 5. Air Flow Performance TEM6AOC36H31SB,TEM6AOC42H41SB COOLING AIRFLOW PERFORMANCE,WET COIL,NO FILTER,NO HEATER OUTDOOR SPEED AIRFLOW DIP SWITCH SETTING AIRFLOW EXTERNAL STATIC PRESSURE U(TONS)E SETTING SETTING POWER (TONS) SWl SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 300 CFM/ CFM 761 755 719 654 560 LOW ton ON ON OFF ON Watts 63 98 131 163 193 2.5 NORMAL 341CFM/ ON ON OFF OFF CFM 862 861 834 781 700 ton Watts 82 120 158 196 235 HIGH 384 CFM/ ON ON ON OFF CFM 962 963 948 915 863 ton Watts 106 147 190 234 279 LOW 319 CFM/ OFF ON OFF ON CFM 961 962 947 914 862 ton Watts 106 147 189 233 279 3 NORMAL 363 CFM/ OFF ON OFF OFF CFM 1092 1093 1082 1060 1026 ton Watts 146 192 240 288 337 HIGH 408 CFM/ OFF ON ON OFF CFM 1231 1231 1221 1203 1175 ton Watts 196 249 301 353 404 LOW 315 CFM/ ON OFF OFF ON CFM 1104 1105 1094 1072 1039 ton Watts 150 197 245 293 343 3.5 NORMAL 357 CFM/ ON OFF OFF OFF CFM 1258 1258 1248 1229 1201 ton Watts 209 263 317 369 421 HIGH 402 CFM/ ON OFF ON OFF CFM 1418 1415 1401 1379 1348 ton Watts 286 347 406 462 516 LOW 308 CFM/ OFF OFF OFF ON CFM 1238 1238 1229 1210 1182 ton Watts 199 253 306 357 408 4 NORMAL 350 CFM/ OFF OFF OFF OFF CFM 1412 1410 1398 1378 1349 ton Watts 282 344 404 462 517 HIGH 394 CFM/ OFF OFF ON OFF CFM 1570 1528 1473 1406 1326 ton Watts 1 393 1 436 466 483 488 (a) Factory Default Setting Table 6. Air Flow Performance TEM6AOC36H31SB,TEM6AOC42H41SB HEATING AIRFLOW PERFORMANCE,NO FILTER,NO HEATER OUTDOOR SPEED AIRFLOW DIP SWITCH SETTING AIRFLOW EXTERNAL STATIC PRESSURE UNIT SIZESETTING SETTING POWER (TONS) SWl SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 LOW 341CFM/ ON ON OFF ON CFM 860 863 838 788 707 ton Watts 77 115 154 193 232 2.5 NORMAL 379 CFM/ ON ON OFF OFF CFM 949 953 937 906 852 ton Watts 98 1 138 180 224 1 269 HIGH 417 CFM/ ON ON ON OFF CFM 1042 1046 1036 1015 980 ton I Watts 122 166 212 259 308 LOW 381CFM/ OFF ON OFF ON CFM 1147 1149 1141 1123 1094 ton Watts 154 203 253 303 353 3 NORMAL 424 CFM/ OFF ON OFF OFF CFM 1277 1279 1272 1255 1228 ton Watts 204 259 314 1 368 421 HIGH 466 CFM/ OFF ON ON OFF CFM 1409 1409 1401 1384 1357 ton Watts 260 323 383 442 500 LOW 348 CFM/ ON OFF OFF ON CFM 1222 1224 1216 1200 1174 ton Watts 180 232 285 336 388 3.5 NORMAL 386 CFM/ ON OFF OFF OFF CFM 1361 1362 1354 1337 1310 ton Watts 240 300 358 415 471 HIGH 425CFM/ ON OFF ON OFF CFM 1497 1478 1449 1408 1356 ton Watts 316 372 420 461 494 LOW 338 CFM/ OFF OFF OFF ON CFM 1360 1361 1353 1336 1309 ton Watts 239 299 358 415 470 4 NORMAL 375CFM/ OFF OFF OFF OFF CFM 1511 1489 1456 1412 1355 ton Watts 1 325 1 380 426 464 493 HIGH 413 CFM/ OFF OFF ON OFF CFM 1 1659 1 160-9 1535 1450 1349 ton Watts 420 463 488 494 483 (a) Factory Default Setting 10 22-1907-1 G-EN TRANE Performance and Electrical Data Table 7. Air Flow Performance TEM6AOC48H41SB,TEM6AOC60HS1SB COOLING AIRFLOW PERFORMANCE,WET COIL,NO FILTER,NO HEATER OUTDOOR SPEED AIRFLOW DIP SWITCH SETTING AIRFLOW EXTERNAL STATIC PRESSURE UNITSIZE SETTING SETTING (TONS) SW1 SW2 SW3 SW4 POWER 0.1 0.3 0.5 0.7 0.9 LOW 324 CFM/ ON ON OFF ON CFM 991 985 974 984 994 ton Watts 89 133 186 237 303 3 NORMAL 368 CFM/ ON ON OFF OFF CFM 1120 1119 1110 1116 1122 ton Watts 118 167 224 279 333 HIGH 423 CFM/ ON ON ON OFF CFM 1282 1286 1281 1280 1282 ton I Watts 162 219 280 343 402 LOW 314 CFM/ OFF ON OFF ON CFM 1116 1114 1105 1111 1117 ton I Watts 117 165 222 277 331 3.5 NORMAL 357 CFM/ OFF ON OFF OFF CFM 1263 1266 1261 1261 1263 ton Watts 156 212 273 334 392 HIGH 411CFM/ OFF ON ON OFF CFM 1449 1458 1456 1449 1447 ton Watts 218 287 352 421 496 LOW 298 CFM/ ON OFF OFF ON CFM 1207 1208 1201 1203 1207 ton Watts 140 193 252 311 366 4 NORMAL 339 CFM/ ON OFF OFF OFF CFM 1368 1374 1370 1367 1367 ton Watts 190 252 315 1 381 448 HIGH 389 CFM/ ON OFF ON OFF CFM 1564 1577 1577 1 1567 1561 ton Watts 264 343 411 484 570 LOW 305CFM/ OFF OFF OFF ON CFM 1534 1545 1545 1536 1531 ton Watts 1 251 328 394 467 550 5 NORMAL 347 CFM/ OFF OFF OFF OFF CFM 1740 1758 1762 1745 1734 ton Watts 344 444 518 594 684 rHIHce> 399 CFM/ OFF OFF ON OFF CFM 1995 2022 2030 2005 1987 ton Watts 484 629 1 717 783 828 0) Factory Default Setting N Airflow must not exceed 1800 cfm in horizontal right,horizontal left,and downflow applications due to condensate blowoff.The 5 ton high tap shall not be used in these applications. Table 8. Air Flow Performance TEM6AOC48H41SB,TEM6AOC60HS1SB HEATING AIRFLOW PERFORMANCE,NO FILTER,NO HEATER OUTDOOR SPEED AIRFLOW DIP SWITCH SETTING AIRFLOW EXTERNAL STATIC PRESSURE UNITSIZE SETTING SETTING POWER (TONS) SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 LOW 360 CFM/ ON ON OFF ON CFM 1097 1094 1086 1092 1099 ton Watts 112 160 216 271 326 3 NORMAL 400 CFM/ ON ON OFF OFF CFM 1215 1216 1210 1211 1215 ton Watts 142 196 255 314 369 HIGH 440 CFM/ ON ON ON OFF CFM 1333 1338 1333 1331 1332 ton Watts 178 238 300 365 428 LOW 348 CFM/ OFF ON OFF ON CFM 1232 1234 1228 1229 1233 ton Watts 147 202 261 322 377 3.5 NORMAL 387 CFM/ OFF ON OFF OFF CFM 1366 1373 1369 1366 1365 ton Watts 189 252 314 381 447 HIGH 426 CFM/ OFF ON ON OFF CFM 1500 1511 1510 1502 1498 ton Watts 238 1 311 377 1 449 529 LOW 338 CFM/ ON OFF OFF ON CFM 1364 1370 1366 1363 1363 ton Watts 188 251 313 379 446 4 NORMAL 375CFM/ ON OFF OFF OFF CFM 1509 1520 1519 1511 1506 ton Watts 241 315 382 453 535 HIGH 413 CFM/ ON OFF ON OFF CFM 1659 1674 1676 1662 1654 ton Watts 305 395 466 541 632 LOW 326 CFM/ OFF OFF OFF ON CFM 1637 1652 1653 1641 1632 ton Watts 295 1 383 453 528 618 5 NORMAL 362 CFM/ OFF OFF OFF OFF CFM 1814 1834 1839 1820 1807 ton Watts 381 493 570 645 730 HIGH 398 CFM/ OFF OFF ON OFF CFM 1990 2017 2025 2000 1982 ton Watts 481 625 713 779 1 826 (a) Factory Default Setting 22-1907-1 G-EN 11 TRANE' Performance and Electrical Data Table 9. Air Flow Performance TEM6AOD48H41SB,TEM6AOD6OH51SB COOLING AIRFLOW PERFORMANCE,WET COIL,NO FILTER,NO HEATER OUTDOOR SPEED AIRFLOW DIP SWITCH SETTING AIRFLOW EXTERNAL STATIC PRESSURE UNIT SIZE SETTING SETTING (TONS) SWl SW2 SW3 SW4 POWER 0.1 0.3 0.5 0.7 0.9 LOW 323 CFM/ ON ON OFF ON CFM 979 978 959 922 867 ton Watts 87 126 170 217 269 3 NORMAL 367 CFM/ ON ON OFF OFF CFM 1111 1113 1101 1075 1036 ton Watts 124 168 215 265 317 HIGH 415Cf. ON ON ON OFF CFM 1252 1259 1254 1239 1212 ton Watts 165 214 264 314 364 LOW 315CFM/ OFF ON OFF ON CFM 1111 1113 1101 1075 1036 ton Watts 124 168 215 265 317 3.5 NORMAL 358 CFM/ OFF ON OFF OFF CFM 1259 1266 1261 1246 1220 ton Watts 167 217 267 317 368 HIGH 404 CFM/ OFF ON ON OFF CFM 1419 1428 1425 1411 1386 ton Watts 223 279 334 389 444 LOW 309 CFM/ ON OFF OFF ON CFM 1241 1248 1243 1227 1201 ton Watts 161 210 1 259 309 359 4 NORMAL 351CFM/ ON OFF OFF OFF CFM 1407 1416 1413 1399 1373 ton Watts 218 273 328 383 437 HIGH 396 CFM/ ON OFF ON OFF CFM 1583 1593 1594 1586 1570 ton Watts 296 359 422 485 547 LOW 295CFM/ OFF OFF OFF ON CFM 1478 1487 1486 1474 1452 ton Watts 249 1 307 365 1 423 481 NORMAL 335 CFM/ CFM 1671 1681 1684 1678 1635 5 (a) ton OFF OFF OFF OFF Watts 344 412 479 545 565 HIGH 379 CFM/ OFF OFF ON OFF CFM 1880 1892 1900 1902 1760 ton Watts 476 556 635 714 650 cal Factory Default Setting Table 10. Air Flow Performance TEM6AOD48H41SB,TEM6A0D60H51SB HEATING AIRFLOW PERFORMANCE,NO FILTER,NO HEATER OUTDOOR SPEED AIRFLOW DIP SWITCH SETTING AIRFLOW EXTERNAL STATIC PRESSURE UNIT SIZE SETTING SETTING POWER (TONS) SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 LOW 360 CFM/ ON ON OFF ON CFM 1087 1091 1081 1055 1015 ton Watts 111 153 199 249 301 3 NORMAL 400 CFM/ ON ON OFF OFF CFM 1205 1213 1211 1198 1173 ton Watts 139 186 234 283 333 HIGH 440 CFM/ ON ON ON OFF CFM 1322 1333 1332 1321 1297 ton Watts 175 227 279 332 384 LOW 347 CFM/ OFF ON OFF ON CFM 1219 1228 1226 1213 1189 ton Watts 143 191 240 289 339 3.5 NORMAL 386 CFM/ OFF ON OFF OFF CFM 1351 1363 1363 1351 1328 ton Watts 184 237 290 344 397 HIGH 424 CFM/ OFF ON ON OFF CFM 1482 1495 1497 1489 1471 ton Watts 232 291 349 408 466 LOW 351CFM/ ON OFF OFF ON CFM 1405 1417 1418 1408 1385 ton Watts 201 256 311 367 422 4 NORMAL 390 CFM/ ON OFF OFF OFF CFM 1555 1568 1572 1567 1553 ton Watts 262 323 385 447 509 HIGH 429 CFM/ ON OFF ON OFF CFM 1703 1717 1723 1722 1665 ton Watts 334 403 472 540 560 LOW 327 CFM/ OFF OFF OFF ON CFM 1625 1639 1644 1641 1630 ton Watts 294 359 424 489 554 5 NORMAL 363 CFM/ OFF OFF OFF OFF CFM 1797 1812 1820 1822 1750 ton Watts 384 459 533 606 615 HIGH 400 CFM/ OFF OFF ON OFF CFM 1970 1986 1999 2010 1910 ton Watts 495 581 667 740 680 0) Factory Default Setting 12 22-1907-1G-EN TRANS" Performance and Electrical Data Table 11. Electrical Data TEM6AOB24H21SB HEATER DATA No.of 240 Volt 208 Volt Heater Model No. Circuits/ Capacity Heater Minimum MaximumM2.889800 Heater Minimum Maximum Phases Amps per Circuit OverloadAmps per Circuit Overload kW BTUH Circuit Ampacity Protection Circuit Ampacity Protection No Heater 2.5* 3 152.5* 3 15 BAYHTR1504BRK 1/1 3.84 13100 16.0 23 25 13.8 20 20 BAYHTR1504LUG BAYHTR1505BRK 1/1 4.80 16400 20.0 28 30 3.60 12300 17.3 25 25 BAYHTR1505LUG BAYHTR1508BRK 1/1 7.68 26200 32.0 43 45 5.76 19700 27.7 38 40 BAYHTR1508LUG BAYHTR1510BRK 1/1 9.60 32800 40.0 53 60 7.20 24600 34.6 46 50 BAYHTR1510LUG BAYHTR15178RK CIfGUIt 1(a) 9.60 32800 40.0 53 60 7.20 24600 34.6 46 50 2/1 BA 17BRK Circuitcuit 2 4.80 16400 20.0 25 25 3.60 12300 17.3 22 25 2 BAYHTR351OLUG 1/3 9.60 32800 23.1 32 35 7.20 1 24600 20.0 28 30 BAYHTR3517LUG 1/3 14.40 49100 34.6 46 50 10.80 36900 30.0 40 45 *=Motor Amps al MCA and MOP for circuit 1 contains the motor amps Table 12. Electrical Data TEM6AOB3OH21SB HEATER DATA No.of 240 Volt 1208 Volt Heater Model No. Circuits/ Capacity Heater Minimum Maximum Capacity Heater Minimum Maximum Phases Amps per Circuit Overload Amps per Circuit Overload kW BTUH Circuit Ampacity Protection kW BTUH Circuit Ampacity Protection No Heater 4.3* 5 15 4.3* 5 15 BAYHTR1504BRK 1/1 3.84 13100 16.0 25 25 2.88 9800 13.8 23 25 BAYHTR1504LUG BAYHTR1505BRK 1/1 4.80 16400 20.0 30 30 3.60 12300 17.3 27 30 BAYHTR1505LUG BAYHTR1508BRK 1/1 7.68 26200 32.0 45 45 5.76 19700 27.7 40 40 BAYHTR1508LUG BAYHTR1510BRK 1/1 9.60 32800 40.0 55 60 7.20 24600 34.6 49 50 BAYHTR1510LUG BAYHTR1517BRK Circuit 1(a) 9.60 32800 40.0 55 60 7.20 24600 34.6 49 50 2/1 Circuit 2 BAcuit2 17BRK 4.80 16400 20.0 25 25 3.60 12300 17.3 22 25 BAYHTR351OLUG 1/3 9.60 32800 23.1 34 35 7.20 24600 1 20.0 30 30 BAYHTR3517LUG 1/3 14.40 49100 34.6 48 50 110.801 36900 1 30.0 1 42 45 *=Motor Amps W MCA and MOP for circuit 1 contains the motor amps 22-1907-1 G-EN 13 TRANS" Performance and Electrical Data Table 13. Electrical Data TEM16A0C36H31SB,TEM6A0C42H41SB HEATER DATA No.of 240 Volt 208 Volt Heater Model No. Circuits/ Capacity Heater Minimum Maximum Capacity Heater Minimum Maximum Phases Amps per Circuit Overload Amps per Circuit Overload kW BTUH Circuit Ampacity Protection kW BTUH Circuit Ampacity Protection No Heater 4.3* 5 15 4.3* 5 15 BAYHTR1504BRK 1/1 3.84 13100 16.0 25 25 2.88 9800 13.8 23 25 BAYHTR1504LUG BAYHTR1505BRK 1/1 4.80 16400 20.0 30 30 3.60 12300 17.3 27 30 BAYHTR1505LUG BAYHTR1508BRK 1/1 7.68 26200 32.0 45 45 5.76 19700 27.7 40 40 BAYHTR1508LUG BAYHTR1510BRK 1/1 9.60 32800 40.0 55 60 7.20 24600 34.6 49 50 BAYHTR1510LUG BAYHTR1517BRK Circuit 1 9.60 32800 40.0 55 60 7.20 24600 34.6 49 50 2/1 BA 17BRK Circuitcuit 2 4.80 16400 20.0 25 25 3.60 12300 17.3 22 25 2 BA 23BRK Circuit 1 9.60 32800 40.0 55 60 7.20 24600 34.6 49 50 1(ai 2/1 BA 23BRK Circuitcuit 2 9.60 32800 40.0 50 50 7.20 24600 34.6 43 45 2 BAYHTR3510LUG 1/3 9.60 32800 23.1 34 35 7.20 24600 20.0 30 30 BAYHTR3517LUG 1/3 14.40 49100 34.6 1 48 50 10.80 36900 30.0 42 45 *=Motor Amps (a) MCA and MOP for circuit I contains the motor amps 14 22-1907-1 G-EN TRANE Performance and Electrical Data Table 14. Electrical Data TEM16A0C48H41SB,TEM6AOC60HS1SB HEATER DATA 240 Volt 208 Volt No.of Heater Model No. Circuits/ Capacity Heater Minimum Maximum Capacity Heater Minimum Maximum Phases Amps per Circuit Overload Amps per Circuit Overload kW BTUH Circuit Ampacity Protection kW BTUH Circuit Ampacity Protection No Heater 6.8* 9 15 6.8* 9 15 BAYHTR1504BRK 1/1 3.84 13100 16.0 29 30 2.88 9800 13.8 26 30 BAYHTR1504LUG BAYHTR1505BRK 1/1 4.80 16400 20.0 34 35 3.60 12300 17.3 30 30 BAYHTR1505LUG BAYHTR1508BRK 1/1 7.68 26200 32.0 49 50 5.76 19700 27.7 43 45 BAYHTR1508LUG BAYHTR1510BRK 1/1 9.60 32800 40.0 59 60 7.20 24600 34.6 52 60 BAYHTR1510LUG BAYH 8RK Circuit it 1 9.60 32800 40.0 59 60 7.20 24600 34.6 52 60 1((-a)) 2/1 BAYHTR1517BRK 4.80 16400 20.0 25 25 3.60 12300 17.3 22 25 Circuit 2 BA 23BRK Circuit 1 9.60 32800 40.0 59 60 7.20 24600 34.6 52 60 1(a) 2/1 BAYHTR1523BRK 9.60 32800 40.0 50 50 7.20 24600 34.6 43 45 Circuit 2 BAYHTR1525BRK 6.00 20500 25.0 40 40 4.50 15400 21.6 36 40 Circuit 1(a) BAYHTR1525BRK 6.00 20500 25.0 31 35 4.50 15400 21.6 27 30 Circuit 2 4/1 BAYHTR1525BRK 6.00 20500 25.0 31 35 4.50 15400 21.6 27 30 Circuit 3 BAYHTR1525BRK 6.00 20500 25.0 31 35 4.50 15400 21.6 27 30 Circuit 4 BAYHTR351OLUG 1/3 9.60 32800 23.1 36 40 7.20 24600 20.0 33 35 BAYHTR3517LUG 1/3 14.40 49100 34.6 51 60 10.80 36900 30.0 45 45 *=Motor Amps (a) MCA and MOP for circuit 1 contains the motor amps 22-1907-1 G-EN 15 TRAAFF Performance and Electrical Data Table 15. Electrical Data TEM6AOD48H41SB,TEM6A0D60H51SB HEATER DATA 240 Volt 208 Volt No.of Heater Model No. Circuits/ Capacity Heater Minimum Maximum Capacity Heater Minimum Maximum Phases Amps per Circuit Overload Amps per Circuit Overload kW BTUH Circuit Ampacity, Protection kW BTUH Circuit Ampacity Protection No Heater 6.8* 9 15 6.8* 9 15 BAYHTR1504BRK 1/1 3.84 13100 16.0 29 30 2.88 9800 13.8 26 30 BAYHTR1504LUG BAYHTR1505BRK 1/1 4.80 16400 20.0 34 35 3.60 12300 17.3 30 30 BAYHTR1505LUG BAYHTR1508BRK 1/1 7.68 26200 32.0 49 50 5.76 19700 27.7 43 45 BAYHTR1508LUG BAYHTR1510BRK 1/1 9.60 32800 40.0 59 60 7.20 24600 34.6 52 60 BAYHTR1510LUG BAYH BRK Circuit 1 1((-a) 2/1 9.60 32800 40.0 59 60 7.20 24600 34.6 52 60 ) BAYHTR1517BRK 4.80 16400 20.0 25 25 3.60 12300 17.3 22 25 Circuit 2 BA 23BRK Circuitcuit 1 9.60 32800 40.0 59 60 7.20 24600 34.6 52 60 1(a) 2/1 BAYHTR1523BRK 9.60 32800 40.0 50 50 7.20 24600 34.6 43 45 Circuit 2 BAYHTR1525BRK Circuit it1 1((aa) 6.00 20500 25.0 40 40 4.50 15400 21.6 36 40 ) BAYHTR1525BRK 6.00 20500 25.0 31 35 4.50 15400 21.6 27 30 Circuit 2 4/1 BAYHTR1525BRK 6.00 20500 25.0 31 35 4.50 15400 21.6 27 30 Circuit 3 BAYHTR1525BRK 6.00 20500 25.0 31 35 4.50 15400 21.6 27 30 Circuit 4 BAYHTR351OLUG 1/3 9.60 32800 23.1 36 40 7.20 24600 20.0 33 35 BAYHTR3517LUG 1/3 1 14.40 1491001 34.6 1 51 60 10.80 36900 1 30.0 45 145 *=Motor Amps W MCA and MOP for circuit 1 contains the motor amps 16 22-1907-1 G-EN TRZ4/VE° Minimum Airflow CFM TEM6AOB24H21SB,TEM6AOB3OH21SB Heater Minimum Heater Airflow CFM With Heat Pump Without Heat Pump BAYHTR1504BRK,BAYHTR1504LUG 660 600 BAYHTR1505BRK,BAYHTR1505LUG BAYHTR1508BRK,BAYHTR1508LUG 780 600 BAYHTR1510BRK,BAYHTR1510LUG 780 600 BAYHTR1517BRK 1050 850 BAYHTR351OLUG 780 600 BAYHTR3517LUG 900 850 TEM6AOC36H31SB,TEM6AOC42H41SB Heater Minimum Heater Airflow CFM With Heat Pump Without Heat Pump BAYHTR1504BRK,BAYHTR1504LUG 875 675 BAYHTR1505BRK,BAYHTR1505LUG BAYHTR1508BRK,BAYHTR1508LUG 950 820 BAYHTR1510BRK,BAYHTRi51OLUG 1000 820 BAYHTR1517BRK 1000 820 BAYHTR351OLUG 875 820 BAYHTR3517LUG 1000 950 BAYHTR1523BRK 1300 1140 TEM6AOC48H41SB,TEM6AOC60HSiSB Heater Minimum Heater Airflow CFM With Heat Pump Without Heat Pump BAYHTR1504BRK,BAYHTR1504LUG 1200 975 BAYHTR1505BRK,BAYHTR1505LUG BAYHTR1508BRK,BAYHTR1508LUG 1350 975 BAYHTR1510BRK,BAYHTR1510LUG 1350 975 BAYHTR1517BRK 1365 975 BAYHTR351OLUG 1300 975 BAYHTR3517WG 1365 1120 BAYHTR1523BRK 1365 1300 BAYHTR1525BRK 1810 1505 TEM6AOD48H41SB,TEM6AOD60H51SB Heater Minimum Heater Airflow CFM With Heat Pump Without Heat Pump BAYHTR1504BRK,BAYHTR1504LUG BAYHTR1505BRK,BAYHTR1505LUG 1150 975 BAYHTR1508BRK,BAYHTR1508LUG 1150 975 BAYHTR1510BRK,BAYHTR151OLUG 1150 975 BAYHTR1517BRK 1300 1125 BAYHTR351OWG 1150 975 BAYHTR3517LUG 1300 1125 BAYHTR1523BRK 1380 1125 BAYHTR1525BRK 1550 1345 22-1907-1 G-EN 17 TRANS' Minimum Airflow CFM TEM6AOB24H21SB,TEM6AOB3OH21SB Airflow Performance with Auxiliary Heat Dip Switch Settings Airflow Settings Nominal Airflow Switch 7 Switch 8 See following tables for heater application: Low ON ON 601 Pressure Drop for Electrical Heaters Med-Lo OFF ON 661 Minimum Heating Med Hi ON OFF 781 Aidlow Matrix(on unit nameplates) High OFF OFF 973 TEM6AOC36H31SB,TEM6AOC42H41SB Airflow Performance with Auxiliary Heat Dip Switch Settings Airflow Settings Nominal Airflow Switch 7 Switch 8 See following tables for heater application: Low ON ON 696 Pressure Drop for Electrical Heaters Med-Lo OFF ON 825 Minimum Heating Med Hi ON OFF I150 Airflow Matrix(on unit nameplates) High OFF OFF 1298 TEM6AOC48H41SB,TEM6AOC60HS1SB Airflow Performance with Auxiliary Heat Dip Switch Settings Airflow Settings Nominal Airflow Switch 7 Switch 8 See following tables for heater application: Low ON ON 1000 Pressure Drop for Electrical Heaters Med-Lo OFF ON 1130 Minimum Heating Med Hi ON OFF 1354 Airflow Matrix(on unit nameplates) High OFF OFF 1596 TEM6AOD48H41SB,TEM6AOD60HS1SB Airflow Performance with Auxiliary Heat Dip Switch Settings Airflow Settings Nominal Airflow Switch 7 Switch 8 See following tables for heater application: Low ON ON 997 Pressure Drop for Electrical Heaters Med-Lo OFF ON 1129 Minimum Heating Med Hi ON OFF 1350 Airflow Matrix(on unit nameplates) High OFF OFF 1597 18 22-1907-1 G-EN N N N� CD /� O \Y rn � Z WINNI■ WINNERS — -® WARNING ® CAUTION - _ - . . A -G— �— I r+ HAZARDOUS VOLTAGE! USE COPPER CONDUCTORS ONLY! TL Y1— A` DISCONNECT ALL ELECTRICAL POWER INCLUDING REMOTE UNIT TERNINALS ARE N07 DESIGNED TO ACCEPT OTHER YL/RD—Y2- 01 SCgINECTS OEFORE SERVICING, TYPES Or CONDUCTORS. X�Vh n I•n I.el.,...aI P...,N.1..... ........ F6L,.1.A.1..NY I...<e...D.I.In..a•o..•I. X AY2- LEGEND A HIBN� I 2N V' }FACTORY WIRING L LINE V, ...pK�_ IMOT[71 - 2A V LINE.V. }FIELD WIRING —BK U ■ t R BK MAGNETIC COIL BK I GROUND AD K I - II�R/Y L—GR/Yl ; • JUNCTION RD _�] I L R Q WIRE NUT OR CONNECTOR • wx/BK I 0 TERMINAL I • TRANSFORMER �'YW1 TTTT Jk! FUSE _ TERMINAL BLOCK/BOARD I - - -ONTROL BOARD e a� M RELAY CONTACT RN.O.) on • C a I I I W POL. PLUG FEMALE MOUSING p (MALE TERM,) POI. PLUG MALE HOUSING _ (FEMALE TERM.) �—COLOR OF WIRE BK/BL BUCK WIRE WITH BLUE MARKER CONTROL BOX t--COLOR of MARKER BK BLACK OR ORANGE YL YELLOW IL BLUE RD RED OR GREEN BLOWER SECTION OR BROWN ■M WMITE PR PURPLE • I GR"L GREEN YELLOW NOTES: I-LOA 2OBV OPERATION MOVE TER THE BLACK CAM TRANSFORMER LEAD TO THE 208V CENTER T RAN SFOAMEA TERMINAL. ® 2.SPEED TAPS SHOWN ARE FOR REFERENCE ONLY. SEE INSTALLERS GUI BE FOR RECOMMENDED I SPEED SETTINGS IN YOUR APPLICATION. ICM FAN MOTOR m ; 3.WHI TE/BL ACK LEAD REMAINS CAPPED AND UNUSED, A UNLESS HUNIDISTAT ACCESSARY KIT IS INSTALLED. WITH KIT INSTALLED; AEO/WHITE IT ON CONTROL BOARD WOULD BE CUT, '0' LEAD WOULD BE TIED TO'R' LEAD ON AC [NON-HEAT4 PUMP) SYSTEMS. SEE INSTALLATION GUIDE FOR COMPLETE HOOK UP INSTRUCTIONS. - - - - - - - - - - —II-�- <.L INE CHOKE NOT USED ON ALL MODELS.. . . . . . . . . TRME` Field Wiring Single Stage, Cooling Only Thermostat Air Handler Outdoor Unit 24 VAC HOT u u I I - - - -❑ I FAN I 1 I I 24 VAC B I Common Blue I u 1 I SOV Q J 1t STAGET Fy 1 r - Ty I 1 I I I � I HEATING 2nd STAGE W 1 White HEATGENCY W _ - - Ja BK 1. * Units with pigtails require wirenuts for connections. 2. Cap all unused wires. 3. For BK enabled comfort control, do not connect Y1 or Y2 at the air handler 4. For BK enabled comfort control, cut the jumper wire between R and BK on the control board. See wiring schematic for details. 5. In AC systems for multiple stages of electric heat,jumper W1 and W2 together if comfort control has only one stage of heat. 20 22-1907-1 G-EN TRWE" Field Wiring Single Stage, HP Thermostat Air Handler Outdoor Unit 24 VAC HOT FAN � - - - -❑ 24 VAC Common B - - - BIBe SOV I Q - - - -I O - - - E 15SAGETI T T ry-11 r - Ty Y2 HEATING 2nd STAGE V V 1 V�hite Black EMERGENCY WW2 HEAT Optional DRUK 1. * Units with pigtails require wirenuts for connections. 2. Cap all unused wires. 3. For BK enabled comfort control, do not connect Y1 or Y2 at the air handler 4. For BK enabled comfort control, cut the jumper wire between R and BK on the control board. See wiring schematic for details. 5. In systems for multiple stages of electric heat,jumper W1 and W2 together if comfort control has only one stage of heat. 22-1907-1 G-EN 21 TRANE' Field Wiring 2 Stage, 2 Step, Cooling Only Thermostat Air Handler Outdoor Unit 24 VAC HOT I I FAN flj - - - -FG] I 1 I I 24VACm Common , - I El I O J 15 STAGET Y1 Y2 - - - -El - - - 9 HEATING N 2nd STAGE W 1 EMERGENCY HEAT White M/�LK 1. * Units with pigtails require wirenuts for connections. 2. Cap all unused wires. 3. For BK enabled comfort control, do not connect Y1 or Y2 at the air handler 4. For BK enabled comfort control, cut the jumper wire between R and BK on the control board. See wiring schematic for details. 5. In AC systems for multiple stages of electric heat,jumper W1 and W2 together if comfort control has only one stage of heat. 22 22-1907-1 G-EN TRANE' Field Wiring 2 Stage, 2 Step, HP Thermostat Air Handler Outdoor Unit 24 VAC HOT FAN - - - -❑ 24 VAC p Common - - - - BIBe - - - 1 " soV COOL/HEAT 1st STAGE HEATING ^� 2nd STAGE W' - - - V hi - - B L EMERGENCY HEAT VV W 2 White Optional H 1. * Units with pigtails require wirenuts for connections. 2. Cap all unused wires. 3. For BK enabled comfort control, do not connect Y1 or Y2 at the air handler 4. For BK enabled comfort control, cut the jumper wire between R and BK on the control board. See wiring schematic for details. 5. In systems for multiple stages of electric heat,jumper W1 and W2 together if comfort control has only one stage of heat. 22-1907-1 G-EN 23 TRANE' TEM Convertibility Figure 1. Multi-Position Air Handler ' =No Internal Modifications Required. 0 71 D O o O 0 O O O Refrigerant Connections Downflow ® Condensate Drains O O o Upflow Q Condensate ED 0 `a Drains 0 Vertical Upflow* Vertical Downflow O O CDD AirflowQQ ❑Qo ® =00 QQ Airflow � U O O Horizontal Left Refrigerant Horizontal Right Condensate Connections Condensate Drains Drains Horizontal Left* Horizontal Right 24 22-1907-1 G-EN TRAAFE® TEM6 Air Handler Dimensional Data vv 0 0 o \ ® o � d 0 H ® O ® 0 a Model No. H W D TEM6AOB24H21SB 45.02 18.50 21.13 TEM6AOB3OH21SB 45.02 18.50 21.13 TEM6AOC36H31SB 51.27 23.50 21.13 TEM6AOC42H41SB 51.27 23.50 21.13 TEM6AOC48H41SB 55.87 23.50 21.13 TEM6AOD48H41SB 53.87 26.50 21.13 TEM6AOC60HS1SB 55.87 23.50 21.13 TEM6AOD6OH51SB 53.87 26.50 21.13 22-1907-1 G-EN 25 TRANE® Outline Drawing 21.12 I H I MITI IINRI UNIT CLEARANCE TABLE SERVICE CLEARANCE (RECOMMENDED) SIDES 2' FRONT 21, O..IT BACK 0• B c INLET DUCT 1• OUTLET DUCT N/A AA I NOTE-THIS UNIT LS APPROVED FOR INSTALLATION S.BJ ClEARANCESTOCOMBUSTIBIE MATERM AS 2 Sf STATED ON THE UNIT RATING NAMEPLATE 00 l.II � 9f I.N 2.12 I I m" 2.11 e J.IJ aO El e A.KN :..N 0 A 0, iii I.n -` H N.is 1.JJ .0 IN.s Lu s.n .a i ncs JN 0i� �2.13 E F D LoE I PRODUCT DIMENSIONS Air Handler Model A B C D E F H Flow Gas Line Control Braze TEM6AOB24,30 46.77 18.50 16.50 16.75 4.68 7.33 20.09 TXV 3/4 TEM6AOC36,42 51.27 23.50 21.50 21.75 7.01 9.66 24.59 TXV 7/8 TEM6AOC48,60 55.87 23.50 21.50 21.75 4.68 9.66 27.19 TXV 7/8 TEM6AOD48,60 53.87 26.50 24.50 24.75 7.01 9.66 27.19 TXV 7/8 All dimensions are in inches 26 22-1907-1 G-EN Notes 22-1907-1 G-EN 27 qfni)Ingersoll Rand Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club Car®, Ingersoll Rando, Thermo King®and Trane@—work together to enhance the quality and comfort of air in homes and buildings;transport and protect food and perishables;and increase industrial productivity and efficiency.We are a global business committed to a world of sustainable progre ss and enduring results. �® Rand, T'' THERMO KING TRINE' ingersollrand.com Eta Us Intertek Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 22-1907-1 G-EN 19 Mar 2018 Supersedes 22-1907-1F-EN (January 2018) ©2016Ingersoll Rand MASON COUNTY COMMUNITY SERVICES Permit No. PERMIT ASSISTANCE CENTER: \' -BUILDING -PLANNING -FIRE MARSHAL • (DO 2o 615 W.Alder St-Shelton, WA 98584 www.co.mason.wa.us \� Phone Shelton:(360)427-9670 ext. 352- Fax:(360)427-7798 • �� Phone Belfair:(360)275-4467- Phone Elma:(360)482-5269 PLUMBING & MECHANICAL PERMIT APPLICATION PdM I*k OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: t9J' T-1 FST 56WI)N CArrp. NAME: a iJC. MAILING ADDRESS:Fo 5Q� 21(DCi MAILING ADDRESS: Pp �,� a1140 CITY:' U'y-A1R, STATE: WA ZIP:g85Zr, CITY: Bek�k;,, STATE: 'UJA ZIP: I PHONE:3 t00- 2.9,5- 35�5 PHONE:31oo- -7Tl--777 l CELL: 2nd PHONE: EMAIL : f car 0 P V\CSerV ice . cym EMAIL:SQA- 15 @PNIVSALM QWfN-U•0 Ca L&I REG# 1A orx�cc I j S a I D I EXP.q/a l/ Qa� PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number):i 1355E - 5m"q"89 Zoning: LEGAL DESCRIPTION(Abbreviated): }ICI THI=LX1<5 I-(OM 65 &f)-2 TIeS SITE ADDRESS: (Q0 0 AT KQ ESS&(- , 5-F- I P— CITY: DIRECTIONS TO SITE ADDRESS:C�FF OF WA- 3. TURN O/V AIF TYPE OF JOB: NEW ADD ALT )( REPAIR OTHER USE OF BUILDING LOCATION OF FIXTURES/UNITS- I ST FLOOR 2ND FLOOR BASEMENT GARAGE OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No.of Fixtures Fees Fuel Type:Electric_)( LPG Natural Gas Ductless_ Toilets Type of Unit No.of Units Fees Bathroom Sink Furnace Bath Tubs Heat Pump Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer Gas Outlets Kitchen Sinks Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hose bibs Dryer Vent Other Solar Panel Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. Signature of Owner Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL