Loading...
HomeMy WebLinkAboutSchaefer State RV Park Relocate - MEP Plot / Site Plans - 3/25/1999100' WELL PROTECTION RADIUS / X �-.-� 1 /2A EX UTILITY ABANDON EX SERVICE UNE. SEX GAIWE 1,890 LF X Y 06 g -PRO WELL-- Si Tii J DATE REVISIONS UT 3 SPHAL .c WIDE,. INSTALL 4 .•;:3� 2" ;WATER PIPE AND RESTORE: ASPHALT III KIND.,' 'SEE . . • DETAIL 3, SHEET 5 CAMPV.5-1�'�'' -\K TCHEN CONTRACT NO. • DWGt: D9020ALdwq . = • Xref 2-24X36B, Z9020BN1, " 09/21 /99 09: 40 lane rW1.1SE1)7; PER .:101{``: REVIEW: CAMPSITE 7, CAMPSITE #6 • FXPIRES 0/29/011 CAMPSITE #5 CAMPSITE #4 { o it � 20' e ,'r . O�. rr 'Hem CAMPSITE #3 / t i CAMPSITE #1 Ir /�. � / ' y i/ � ' • y r>,5" EX MM #11 A L L r.>') v S.2 c1 <' v Q °,feed GENERAL NOTE A. DOUBLE SLEEVE WATERLINES 10' ON EITHER SIDE OF SEWER LINE CROSSINGS. ROUTE SEWER LINE TO MAINTAIN 18" VERTICAL SEPARATION W/WATER LINE ABOVE SEWER LINE. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION BY CALLING THE UNDERGROUND LOCATE LINE AT 1-800-424-5555 A MINIMUM OF 48 HOURS PRIOR TO ANY EXCAVATION. THE CONTRACTOR WILL ALSO BE RESPONSIBLE FOR MAINTAINING ALL LOCATE MARKS ONCE THE UTILITIES HAVE BEEN LOCATED. S�CI�IIN.C�S � CoNNolly INC. CONSUITINC{ EIVqi.NEERS CIVIL; TRANSPORTATION - -ENVIRONMENTAL taros am mom. tr.. AACIV WJA !Cr 5114M49141999 FAX -.7i404111Ji!7 VERTICAL DATU ASSUMED = . BASIS OF BEARINGS .` SURVEY OF'SCHAFER. STATE PARK :194 — EXISTING- DITCH EXISTING-- WATER LINE EXISTING STORM DRAINAG - EXISTING SEWER. LINE- E.ISTING FENCE', 'EXISTING STING EXISTING EXISTING EXISTING EXISTING EXISTING HOSE BIB HYDRANT WATT ERMETER WATER MANHOLE: POWER POLE GP POLE CONIFEROUS. TR 0 NEW WELL HEAD''WITH PITLESS ADAPTER. SEE DETAIL 1 ON SHEET 5. INSTALL WOODEN -WELL HEAD PROTECTION STRUCTURE. STRUCTURE BASE TO HAVE 3'Wx3'Lx4" CONCRETE .PAD FLOOR. STRUCTURE SHALL HAVE A SLOPED ROOF 0 AND LOCK. INSTALL 140 LF .OF 1.5" CL -160 PVC WATER LINE BETWEEN STORAGE TANK AND WELL HEAD PITLESS ADAPTER. - • INSTALL BURIED 1" RIDGED CONDUIT BETWEEN PANEL AND WELL HEAD. 24" COVER OVER TOP OF CONDUIT. . INSTALL 1,500 GALLON STORAGE TANK. PROVIDE 10'Wx10'Lx6"D CONCRETE PAD. MOUNT ANCHOR BOLTS IN ACCORDANCE WITH TANK MANUFACTURER. REQUIREMENTS. TANK SHALL HAVE ACCESS LADDER, 24"0 MANHOLE ACCESS LID, VENT W/PROTECTIVE SCREENING, LEVEL INDICATING SIGHT TUBE, AND FULL DRAIN OPTION. THIS DESIGN USES A CENTRAL CALIFORNIA CONTAINER TANK MODEL #05VCTOIE. SEE SHEET 4 FOR WATER SYSTEM DISTRIBUTION SYSTE, LAYOUT. MAINTAIN INSTALL="2'1/2" --CL 7:160- PVC- WATERUNE. Z. SEE DETAIL -.3,-SHEET 5 FOR RESTORATION; -AND- TRENCH DETAIL: TYl' ALL --PIPE). CONNECT N W 2" WATER LINE TO EXIST WATER SERVICE LINE. FIELD VERIFY EX LINE LOCATION. INSTALL 2" GATE VALVE AND VALVE BOX. AFTER INSTALLATION TESTING AND ACCEPTANCE OF NEW WELL, DISCONNECT AND ABANDON EXISTING WELL IN ACCORDANCE W/DOE REQUIREMENTS. - ; INSTALL DOUBLE CHECK VALVE ASSEMBLY WITH BOX. 24"x24" HANDHOLE IN CONC. EXTEND FUTURE 2" LOOP LINE. CAP AND MARK END OF THE FUTURE LINE. GROUP. CAMP WATER SERVICE. SEE DETAIL 2, SHEET 5. INSTALL 2" •90' BEND WITH THRUST BLOCKS 13 INSTALL 2" 45' BEND 14 RECONNECT SERVICE - - - 15 INSTALL DOUBLE CHECK VALVE ASSEMBLY WITH BOX. 24"X24" HANDHOLE. IN - CONCRETE BOX. _ SCHAFER STATE V.vL 29 SHEET -3" OF 5 SHEETS SEP:2 1 1999