HomeMy WebLinkAboutBLD2023-00493 - BLD CD Environmental Health Review - 3/5/2023 •
•
,,`. art:
MASON COUNTY COMMUNITY SERVICES Permit No: l ISOOS
i" c' PERMIT ASSISTANCE CENTER: d ZDZ3—�4f�l°J
1� •BUILDING•PLANNING•PUBLIC HEALTH•FIRE MARSHAL
19 III •£ 615 W.Alder Street,Shelton,WA 98584
j`:. :r Phone Shelton:(360)427-9670 ext.352•Fdx:(360)427-7798 Phone
r,�,,Y) Be/fair:(360)275-4467•Phone Elma:(360)482-5269
BUILDING PERMIT APPLICATION 5
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION:
rr1 g
NAME: Lennar Northwest,Inc. NAME: Lennar Northwest,Inc. m an
MAILING ADDRESS: 33455 6th ave S,Unit 1-B MAILING ADDRESS: 33455 6th Ave S.Unit 1-B < LT, 21
CITY: Federal Way STATE: WA ZIP: 98003 CITY: Federal Way STATE: WA ZIP: 98003 rt o
O PHONE#1: (253)294-1322 PHONE:(253)294-1322 CELL: (253)294-1322 '� w
,,/� PHONE#2: EMAIL: Sam.Martin@Lennar.com
1�1 EMAIL: Sam.MartinALennar.com L&I REG# LENNANL783JO EXP. 03/18/24
8 PRIMARY CONTACT: OWNER❑ CONTRACTOR❑ OTHER
NAME Sam Martin EMAIL Sam.Martin@Lennar.com
t MAILING ADDRESS 33455 6th Ave S.Unit 1-B CITY Federal Way STATE WA ZIP 98003
c0 PHONE (253)294-1322 CELL (253)294-1322
Q J PARCEL INFORMATION:
`V kg.
PARCEL NUMBER(I2 Digit Number)12328-21-00000; Is ZONING
v LEGAL DESCRIPTION(Abbreviated) Olympic Ridge Lo+C, FIRE DISTRICT
SITE ADDRESS 100 NE Belfair Station*Address subject to change* CITY
DIRECTIONS TO SITE ADDRESS
IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES!: NO M SNOW LOAD:25.00psf
4' IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply):
SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑
TYPE OF WORK: NEW M ADDITION❑ ALTERATION❑ REPAIR❑ OTHER M
USE OF STRUCTURE(Residence,Garage,Commercial Bldg,Etc.)New SFR using approved stock#2018-0030 Plan 2439 Elevation A GL
NIS USE: PRIMARY❑ SEASONAL❑ NUMBER IOF BEDROOMS 4 NUMBER OF BATHROOMS 2.5
[[t( (1 HEATED STRUCTURE? YES(Whole Bldg)❑ YES(PartlsjofBldg)® NO❑
\VI DESCRIBE WORK New Single Family Residence heated and garage unheated
SQUARE FOOTAGE: (proposed)
1ST FLOOR 989 sq.ft. 2ND FLOOR 1351 sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft.
DECK sq.ft. COVERED DECK sq.ft. STORAGE sq.ft. OTHER so sq.ft.
GARAGE 59l sq.ft. Attached❑ Detached❑ CARPORT sq.ft. Attached❑ Detached❑
MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED*
MAKE MODEL YEAR . LENGTH
WIDTH BEDROOMS BATHS_ SERIAL NUMBER
ENVIRONMENTAL HEALTH:
SEWAGE/SEWER SOURCE: SEPTIC❑ SEWER M / NEW M EXISTING❑
PLUMBING IN STRUCTURE? YES® NO❑ If yes,attach completed Water Adequacy Form
PERIMETER/FOUNDATION DRAINS PROPOSED? YES M NO❑ EXISTING SQ.FT. 1630 sqft
EXISTING BEDROOMS PROPOSED BEDROOMS (—;` TOTAL BEDROOMS �I
OWNER acknowledges that submission of inaccurate information may result in a stop worl order or permit revocation.Acknowledgement of such is by
signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have
obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal
representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permit/application becomes null 8 void if work or authorized construction is not commenced within 180
days or if construction work is suspended for a period of 180 days.
PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON
COUNTY CODE 14.08.42)
x 'ayrL 711 2-9-2023
Signature of OWNER(Must be signed by the OWNER) Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
' PLANNING DEPARTMENT
FIRE MARSHAL
PUBLIC HEALTH .VA l -We) Cj*A/S G
"R•5"Median density residential district BUILDING SETBACKS:
TCE =INSTALL TEMP. CONST. ENTRANCE FRONT: 10' SIDE: 5' REAR: 10'
Front yard:10 feet.
Side yard:5 feet for accessory structures and 5 feet for the TSS =INSTALL TEMP. SOIL STOCKPILE
dwellingunit.
Street sidea yard. 10 feet.
Rear yard:5 feet for accessory structures and 10 feet for the
dwelling unit. Z
Street rear yard:10 feet. TRACT F PROPOSED
CONTOURS
S15'12'45'E 53.00'
- - _ 05/04/2023
APPROVED
- - - - MASON COUNTY DCD PLANNING
v v SCOTT IZUEDYAICP
TSS
Lri
N BSBL � N Digitally
(NP) ed
PATIO s°°°""�by Scott
Ruedy
--O..- 15 .� — — --- __.• ._•. _ 8' -0 L
} 40'
Y
HS5 1..._______....--EAVE
•
BUILDING
N PROPOSED ENVELOPE
SFR
5' ! — __I6`�
2439A
0
" flu 0 rn I GARAGE L I „.
r`
Z
127' z
O. CONCRETE DRIVEWAY
ppRC $, In
SS STUB • L — --: O -
_ _ _ • STORM
`co
O 2 STUB
NTnjv) WALK ---
T — -' 1 -�- — — — \ TRANSFORMER u"
O D Ni
TCE
1 O 4 1—.) I---.---‘
i-NWM' N15'12'45"W 53.00'
i d SIDEWALK
i • to
--- --- --- --SDMH Public sewer and water
INSTALL SILT FENCE,
BELFAIR STATION STRAW WATTLE, OR EH APPROVED
FUNCTIONALLY EQUIVALENT
Rhonda Thompson 05/08/2023
LOT SIZE = 5,035 SF SOIL AMENDMENT NOTE:
SEE BMP T5.13 "POST CONSTRUCTION
IMPERVIOUS SOIL QUALITY AND DEPTH", WSDOE
TOTAL IMPERVIOUS: 2,592 SF (51.5%) STORMWATER MANAGEMENT MANUAL
ROOF: 1,848 SF FOR WESTERN WASHINGTON.
DRIVEWAY: 596 SF FLAT WORK NOTE:
WALK: 40 SF LOT COVERAGE = 1,848 SF (36.7%) FLAT WORK IS SHOWN FOR ILLUSTRATIVE
PATIO: 108 SF (INCLUDES EAVES) PURPOSES ONLY. FINAL CONDITIONS MAY VARY.
Job Number 0 10 20 40
21885 Scole 1.=20'
�� ���� LENNAR NORTHWEST INC.
Barghausen OLYMPIC RIDGE
Sheet Drown
Dbriggs Consulting Engineers, Inc. HOMESITE 5
18215 72nd Avenue South PARCEL NO. TBD
Kent,W 98032
1 of 1 Dote 2/5/23 425.251.6222 barghausen.com TBD, BELFAIR, WA
Ile:=:\21000s\21885\lot\21885-Olympic Ridge-Plot Plons.dwg Plot Dote/Time:2/5/2023 12:56 PM OBRIGGS