Loading...
HomeMy WebLinkAboutSWG2022-00586 TANK ONLY - SWG Application / Design - 11/23/2022 MASON COUNTY 415 N 6TH STREET,SHELTON, 98584 SHELTON:360 427-9679670,EXT 400 BELFAIR: 360-275-4467,EXT 400 Public Health & Human Services ELMA:360-482-5269,EXT 400 FAX:360-427-7787 On-Site Sewage System Tank Only Permit: SWG2022-00586 OWNER HOUSE SHIRLEY J Phone: Address: 33 E DANA DR SHELTON, WA 98584 APPLICANT HOUSE SHIRLEY J Phone: Address: 33 E DANA DR SHELTON, WA 98584 SEPTIC INSTALLER Shane Maples-MAPLES EXCAVATING Phone: 360-463-8474 Address: 911 SE Arcadia Road SHELTON, WA 98584 Site Address: 33 E DANA DR Primary Parcel Number: 219015000020 Permit Description: Replace septic tank Permit Submitted Date: 11/23/2022 Permit Issued Date: 11/30/2022 Issued By: Rhonda Thompson Current Permit Fees Paid: $240.00 (additional fees may be required upon installation of system). Permit Expiration Date: 11/30/2023 (based on date of inspection) Type of Work OSS Repair Components being Replaced: Septic Tank Only Surfacing Sewage? No Existing Failure? Yes Shoreline? Yes Horizontal Setbacks Met? Yes Number of Bedrooms: 2 Drinking Water Source: Public Water System Additional Details: IM-1060 Permit Conditions: 4 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 3 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. 1 Horizontal setbacks per WAC246-272A-0210 must be maintained, unless prior approval is obtained THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND/OR DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsiteloss-inspection-request.php or call: 360-427-9670, extension 400. (9 OFFICIAL USE ONLY DATE RECEIVED. MASON COUNTY 11 l - \ -o-�. y D COMMUNITYSERVICES AMOUNT RECEIVED. ^tk 0 RECEIVED BY (h' 0 m 1 Public Health (Community Health/Environmental Health) "'l� R 360-427-9670,ext.400 or 360-27S�467.eat.400 VV O 415 N.6th Street-Shelton,WA 98584 SWG a ^l� O(D 5,b O 2 vt-j/ Itf Z 6 -13 ON-SITE SEWAGE TANK ONLY APPLICATION 3. 73 APPLICANT PHONE m m ShilrIN hIllicQ, elf el t oLce- 2.'2)-33) -5S)I T MAILING ADDRESS-STREET,CITY,STATE,ZIP CODE p` �,^ A /� q f ^: 3 -?3 E. Dan& Dr. Cr lei ►r VvA -1g5O-1 .. W m SITE ADDRESS-STREET.CITY,ZIP CODE ��. 33 - - DAyla, Dr. chelt't, 1rJA 6185q ' IN NAME OF DESIGNER PHONE i t to I. NAME OF INSTALLER PHONE v' MOM( EXCavatInei I sha.r)e H apitc 33L0- . -- 1y z TYPE OF WORK(select one) DRINKING WATER SOURCE ❑ NEW CONSTRUCTION/UPGRADES REPAIR/REPLACEMENT 0 yRIVATE INDIVIDUAL WELL 0 PRIVATE TWO-PARTY WELL Z COMP NENT(S)TO BE REPLACED/INSTALLED L-7/PUBLIC WATER SYSTEM SEPTIC TANK 0 PUMP TANK 0 RV HOLDING TANK BEDROOMS LOT SIZE ILI\ ❑ OTHER 2 .140 CO OTHER DETAILS(select all that apply) TAN S)SETBACK CHECKLIST I— rst 0 t ❑ SURFACING SEWAGE EXISTING FAILURE 0 SHORELINE 4100FT+PUBLIC/COMMUNITY WELLS id SUBA'NTTALS , SOFT+PRIVATE WELLS,SURFACE WATERS,STREAMS,RIVERS 1 d PLOT PLAN(REQUIRED) EiTANK CROSS SECTION(REQUIRED) 10FT+DRINKING WATER SUPPLY LINES ❑ PUMP DETAILS(IF APPLICABLE) 0 WAIVER(S)(IF APPLICABLE) 5FT+PROPERTY/EASEMENT LINES,FOUNDATIONS,FOOTINGS PLOT PLAN CHECKLIST - 0 0 ❑ PROPERTY LINES AND EASEMENTS ❑ EXISTING/PROPOSED STRUCTURES 0 EXISTING/PROPOSED OSS COMPONENTS AND LINES —I ❑ WELLS WITHIN 100FT 0 WATER SUPPLY LINES 0 DRIVEWAYS/PARKING 0 SURFACE WATERS,STREAMS,RIVERS,ETC... ❑ DIRECTION OF SLOPE/CONTOURS ❑ PERIMETER/CURTAIN DRAINS 0 NORTH ARROW 0 SCALE BAR DIRECTIONS TO SITE AND SITE CONDITIONS:(ex.locked gate) 71 ( ./....tlES DeCOYYliTIIY7ltx- cad failed taa1 ,repec1(,c. tubt-vi low i► i Itratu�� Rii 5 ept� c; to.fl .I4 fl1 c i Dub t1 a s vo-li NO C -VtAilttUWillclOW UTat'lfr tflL -RAIf u3iLn dare.. 4 1 OFFICIAL USE ONLY BELOW THIS LINE l l ,.l UPGRADE/FAILURE SOURCE(tor reporting purposes) ❑VOLUNTARY MAINTENANCE/PUMPING ❑BUILDING PERMIT ['HOME SALE ❑COMPLAINT ❑OTHER: COMMENTS/CONDITIONS I_. ' F, PRAA(A-te- Seel C 'VA 11\\L S ilk rk \0Cle)On _ t _ Fri, r SEWAGE TANKS MUST BE LISTED UNDER DOH'LIST OF REGISTERED SEWAGE TANKS'. TANKS MUST MEET CURRENT MINIMUM SIZE REQUIREMENTS,EQUIPPED WI*RISERS C C7-7-3 AND LIDS TO SURFACE,AND INCLUDE AN EFFLUENT FILTER(IF APPLICABLE). RECORD DRAWING AND INSTALLATION REPORT REQUIRED FOR FINAL APPROVAL. C. { I:- 1 INSPECTOR SIGNATURE DATE APPLICATION EXPIRATION DATE APPLICATION APPROVED/ISSUED BY DATE' .� N� THIS FORM MAY BE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEBSITE REVISED 12 7/2015 �V•V 3.5s C' �..----��---� - - Nouse, Fa ited Tar*. dec orrm‘ssion Neu) ►Ouo►,nh� 111'oY c ;G-rark scum& 100tion APPROVED NOV 3 0 2022 MASON COUNTY ENVIRONMENTAL HEAL' RET Fr- (14 E. Dana Dr . APPROVED NOV 3 0 2022 MASON COUNTY ENVIRONMENTAL HEALTH i��l aEr 4 Y.- • • Q 8 11---- IM-1060 INFILTRATOR septic tanks Features&Benefits Strong injection molded polypropylene construction • Lightweight plastic construction and inboard lifting lugs allow for easy j ; % ! 1 delivery and handling • Integral heavy-duty green lids that e Fr . tr .-2. 1 l interconnect with Win" risers and pipe I' riser solutions rrrr[arritifKIffit III iii If Ilt K K StMN0 • NV II Y it • Structurally reinforced access ports eliminate distortion during installation and pump-outs 8 it (� • Reinforced structural ribbing and . C.. fiberglass bulkheads offer additional strength • Can be installed with 6"to 48" of cover The Infiltrator IM-1060 is a lightweight strong and durable septic tank. • Can be pumped dry during This watertight tank design is offered with Infiltrator's line of custom-fit pump-outs risers and heavy-duty lids. Infiltrator injection molded tanks provide a • Suitable for use as a septic tank, pump revolutionary improvement in plastic septic tank design, offering long-term tank, or rainwater(non-potable)tank exceptional strength and watertightness. • No special water filling requirements Inlet Side are necessary • The tank may be backfilled with suitable Infiltrator TANK CUTAWAY native soil. See installation instructions TW Riser for guidance. System - -- --- `'' • Partition baffle wall • HEAVY DUTY LID - CUTAWAY Reinforced 24"structural access port I) . , � P P R O V n Structural { ; ;� bulkheads NOV 3 0 2022 MID-SEAM CUZ�A�(yi�1�Ep,JhnEhVjRON:ME2NTAL HEALTH Reinforced water tight mid-seam RET gasketed connection 01,0_ (--(-- INFILTRATOR' Protecting the Environment with Innovative Wastewater Treatment Solutions water technologies • IM-1060 General Specifications and Illustrations UFTING STRAP LIFTING RUG —RISER CONNECTION ITYPICAL) 14 TOTAL) / (TYPICAL) The IM-1060 is an injection molded two piece mid-seam ', :. 1 r;,i `, r plastic tank. The IM-1060 injection molded plastic design 'ii n= 1 ��A01I ik allows for a mid-seam joint that has precise dimensions A ;ram-�►' ��� �I� ' R;1 A INT% 0 1 t 1 i t r�o •ice"� for accepting an engineered EPDM gasket. Infiltrators t ,. o o —• t Et gasket design utilizes technology from the water industry �_I d °o�: .;. °o���,;, 62� r� IIS801 to deliver proven means of maintaining a watertight seal. kb.!!=5 °.� u t t t L. ° "ilt`; EXTERIOR TH The two-piece design is permanently fastened using a ` '—vvida I I I I aL�� ` WIDTH series of non corrosive plastic alignment dowels and �. .lJ . I,.„ locking seam clips. The IM-1060 is assembled and sold through a network of certified Infiltrator distributors. 1270132261EXTEAKA LENGTH Must be backfilled and installed in accordance with TOP VIEW Infiltrator Water Technologies, Infiltrator IM-Series Septic Tank General Installation Instructions and for shallow ) ground water conditions reference the Infiltrator IM- // Series Tank Buoyancy Control Guidance. c 54.7 Please visit www.infiltratorwater.com/images/pdf/ 113891 EXTERIOR ManualsGuides/TANK01.pdf for the latest information. HEIGHT SEAM CLIP—f (TYPICAL) IM-1060 LIFTING STRAP Working Capacity 1094 gal(4141 L) (TYPICAL) Total Capacity 1287 gal(4872 L) END VIEW Airspace 16.5% Length 127"(3226 mm) 04[1021 0 24[610)ACCESS OPENINGS WITH LOCKING LIDS(2) u 62.2"(1580 mm) PVC OR ABS 0 4 1102)PVC OR INLET TEE f0212601 FREEBOARD Width ABS OUTLET TEE Length-to-Width Ratio 2.3 to 1 ? INLET I 16.5% AIRSPACE OUTLET S Height 54.7"(1389 mm) L a CO_ff OPER L 1 -1 Liquid Level 44"(1118 mm) 44.0 FIBERGLASS 11118] FIBERGLASS 11111 Invert Drop 3"(76 mm) SUPPORT LIQUID _—SUPPORT 1TYPICAL) DEPTH (TYPICAL) 1 LiWRH BAFFLE -1Fiberglass Supports 2 WALL WHERE REQUIRED Compartments 1 or 2 1� '�T 1 T I!r`TI )..e4 Maximum Burial Depth 48"(1219 mm) SIDE VIEW Minimum Burial Depth 6"(152 mm) Maximum Pipe Diameter 6"(152 mm) TANK TOP CONTINUOUS Weight 320 lbs(145 kg) HALF GASKET TANK II APPROVED INTERIOR pity"' +j SEAM CLIP ALIGNMENT a�aaa//// NOV 3 0 2022 DOWEL gTANK BOTTOM s, HALF P.O.Box? Road MASON COUNTY ENVIRONMENTAL HEALTF, I Old68 Saybrook,CT 06475 N F I LT R AT O R� 860-577-7000•Fax 860-577-7001 RET MID-HEIGHT SEAM SECTION I 1-e00-221-4436 water technologies www.InflItratorswater.com U.S.Patents:4,759,681;5,017,041;5,156,488;5,336,017;5.401,116;5,401,459:5,511,903;5,716,163;5,588,778;5,839,844 Canadian Patents:1,329,959;2,004,564 Other patents pending.Infiltrator,Equalizer, Quick4,and Sidewinder are registered trademarks of Infiltrator Water Technologies,Infiltrator is a registered trademark in France.Infiltrator Water Technologies is a registered trademark in Mexico. Contour,Microleaching,PotyTuff,ChamberSpacer,MultiPort,PosiLodt,QuickCut,QutckPlay,SnapLock and StraightLock are trademarks of Infiltrator Water Technologies. PolyLok Is a trademark of Polyl.ok,Inc.TUF-TITE Is a registered trademark of TUF-TITE,INC.Ultra-RID Is a trademark of IPS(Inc. Cn 2016 Infiltrator Water Technologies,LLC.All rights reserved.Printed In U.S.A. 1M021116 Contact Infiltrator Water Technologies' Technical Services Department for assistance at 1-800-221-4436