Loading...
HomeMy WebLinkAboutSWG2022-00162 - SWG Application / Design - 3/30/2022 415 N 6TH STREET,SHELTON,WA 98584 MASON COUNTY S SHELTON:360-427-9670,EXT 400 j' COMMUNITY SERVICES BELFAIR:360-275-4467,EXT 400 4. 1 s ELMA:360-482-5269,EXT 400 , Budding,Planning,Envkonuntel lteolth,Community Health atrrR`4 FAX:360-427-7787 On-Site Sewage System Tank Only Permit: SWG2022-00162 APPLICANT CONNOR MARIN Phone: Address: PO BOX 73399 PUYALLUP, WA 98373 OWNER LARSON CREDIT TRUST DOUGLAS C Phone: Address: ROBIN T LARSON TRUSTEE BELFAIR, WA 98528 Site Address: 16631 E STATE ROUTE 106 Primary Parcel Number: 222145000902 Permit Description: Permit Submitted Date: 03/30/2022 Permit Issued Date: 03/31/2022 Issued By: Current Permit Fees Paid: $240.00 (additional fees may be required upon installation of system). Permit Expiration Date: 03/30/2025 (based on date of inspection) Type of Work OSS Repair Components being Replaced: Septic Tank Only Surfacing Sewage? No Existing Failure? Yes Shoreline? Yes Horizontal Setbacks Met? Yes Number of Bedrooms: 2 Drinking Water Source: Private Two-Party Well Additional Details: Permit Conditions: 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 1 Horizontal setbacks per WAC246-272A-0210 must be maintained, unless prior approval is obtained 3 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. 4 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND/OR DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: www.co.mason.wa.us/health/environmental/onsiteloss-inspection-request.php or call: 360-427-9670, extension 400. 4 —• -- OFFICIAL USE ONLY - MASON COUNTY DATE RECEIVED. 3 _ ^ 3 to D l 1. - COMMUNITY SERVICES AMOUNT R LtO n RECEIVED v m Public Health(Community Health/EnvironmentalHealth) ��/� < 0 415 N 6th 70,Street 4Shelton, n, 985467,eM 400 SWG ,ca -C c [(Da O 73 ' 415 N.bth Street-Shehon,WA 98584 Z N 11 ON-SITE SEWAGE TANK ONLY APPLICATION x, APPLICANT PHONE m m r Connor Marin 253-244-1187 pr) z -, c MAILING ADDRESS-STREET.CITY,STATE.ZIP CODE w P.O. Box 73399, Puyallup,WA 98373 O m rn SITE ADDRESS-STREET,CITY.ZIP CODE 0 11631 Washington 106, Belfair,WA 98528 -I I N NAME OF DESIGNER PHONE n _. N/A N/A rn I NAME OF INSTALLER PHONE O Northwest Cascade 253-848-2371 < p (7) co TYPE OF WORK(select one) DRINKING WATER SOURCE p ❑ NEW CONSTRUCTION/UPGRADES ® REPAIR/REPLACEMENT El PRIVATE INDIVIDUAL WELL 0 PRIVATE TWO-PARTY WELL Z N COMPONENT(S)TO BE REPLACED/INSTALLED El PUBLIC WATER SYSTEM Z 1 1 III SEPTIC TANK 0 PUMP TANK 0 RV HOLDING TANK BEDROOMS LOT SIZE D I O OTHER 2 1.35 Acres CO OTHER DETAILS(select all that apply) TANK(S)SETBACK CHECKLIST r O ❑ SURFACING SEWAGE ®EXISTING FAILURE ❑ SHORELINE 0 100FT+PUBLIC/COMMUNITY WELLS n SUBMITTALS 0 50FT+PRIVATE WELLS,SURFACE WATERS,STREAMS,RIVERS O PLOT PLAN(REQUIRED) I l TANK CROSS SECTION(REQUIRED) ❑ 10FT+DRINKING WATER SUPPLY LINES Z ❑ PUMP DETAILS(IF APPLICABLE) 0 WAIVER(S)(IF APPLICABLE) 0 5FT+PROPERTY/EASEMENT LINES,FOUNDATIONS,FOOTINGS PLOT PLAN CHECKLIST r O 4 0 PROPERTY LINES AND EASEMENTS ❑ EXISTING/PROPOSED STRUCTURES 0 EXISTING/PROPOSED OSS COMPONENTS AND LINES —I ❑ WELLS WITHIN 100FT ❑ WATER SUPPLY LINES 0 DRIVEWAYS/PARKING ❑ SURFACE WATERS,STREAMS,RIVERS,ETC... ❑ DIRECTION OF SLOPE/CONTOURS ❑ PERIMETER/CURTAIN DRAINS 0 NORTH ARROW ❑ SCALE BAR CO DIRECTIONS TO SITE AND SITE CONDITIONS:(ox.locked gate) C*—t O�9 75 7 C OFFICIAL USE ONLY BELOW THIS LINE IV UPGRADE/FAILURE SOURCE(for reporting purposes) Z ❑VOLUNTARY ❑MAINTENANCE/PUMPING 0 BUILDING PERMIT ❑HOME SALE ❑COMPLAINT POTHER: C Z-7.7 COMMENTS/CONDITIONS SEWAGE TANKS MUST BE LISTED UNDER DOH LIST OF REGISTERED SEWAGE TANKS'. TANKS MUST MEET CURRENT MINIMUM SIZE REQUIREMENTS,EQUIPPED WITH RISERS AND LIDS TO SURFACE,AND INCLUDE AN EFFLUENT FILTER(IF APPLICABLE). RECORD DRAWING AND INSTALLATION REPORT REQUIRED FOR FINAL APPROVAL. INSPECTOR SIGNATURE DATE APPLICATION EXPIRATION DATE APPLICATION APPROVED/ISSUED BY DATE /160ILk —3(- THIS FORM MAY BE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEBSITE REVISED 12/7/2015 THURSTON-MASON HEALTH DISTRICT 529 W..4TH'.PHONE 753'8073 ' P.O.BOX 746 110 W. ',K"5T. PHONE 426-4407 OLYMPIA, WA 98501 - - • ' r SHELTON, WA 98584 RECORD OF FINAL INSPECTION OF YOUR SEWAGE DISPOSAL SYSTEM OWNER C • 6.01 It-- TOWNSHIP RANGE SEC. y THIS RECORD IS NOT A GUARANTEE OF PERFORMANCE. NAME QF UOT / � Q NO. A SEPTIC SYSTEM IS NOT A MUNICIPAL SEWER. HOWEVER FLAy,Y�' � > Qf,►CS WITH PROPER MAINTENANCE AND CAREFUL USE OF SOIL Q ,�d,���,/ y /. COMMENTSvt" GlAi^J WATER IT CAN GIVE MANY YEARS OF TROUBLE FREE SER• AERA 104N VICE. MANY PROBLEMS WITH SEPTIC TANKS ARE CAUSED SITE M — �5�3 0... / X // J � SIZEI 3 ��!'�.f UAW BY FLUSHING EXCESSIVE AMOUNTS OF PAPER, CLOTH AND PLASTIC MATERIALS DOWN THE DRAIN, OR BY LARGE WATER TO TABLE MONTH G SRBAGE GE `- YES AMOUNTS OF WATER FROM LEAKY FAUCETS OR FAULTY WATER ER /� NO FIXTURES. INj�,�Ji l ks-i^---- THE SEPTIC TANK ITSELF SHOULD BE CLEANED EVERY SIZE TWO OR THREE YEARS DEPENDING ON THE HABITS OF THE SEPTIC TANK ISI �' p 0 • 2-CNrp FAMILY, THE NUMBER OF FIXTURES IN THE HOUSE, AND TOTAL FEET THE AMOUNT THAT A GARBAGE DISPOSAL IS USED. LENGTH DRAINFIELD A a a0.1Y0 0/ � 05.70!71�� CLEANING AT THE RIGHT TIME WILL AVOID THE RISK OF TRENCH AREA 8 ! TOTAL SQ.FT. INJURING OR DESTROYING THE DRAINFIELD DUE TO D K /J SOLIDS CARRYING OVER INTO THE DRAINFIELD. CALL THE S ssieav, v THURSTON•MASON HEALTH DISTRICT FOR A LIST OF LIC TILE ❑ CORRUGATED ❑ SOLID ❑CEMENT ENSED SEPTIC TANK CLEANERS IN YOUR AREA. THE CLEAN• DEPTH ER CAN SERVE YOU BEST IF YOU SHOW HIM THIS RECORD ROCK CU. YDS. /Q — /I DEPTH INCHES WHEN HE COMES. 4 HEAVY TRUCKS OR EQUIPMENT SHOULD NEVER BE SPACE RESERVED FOR SQ. FT. DRIVEN OVER THE TANK OR DRAINFIELD. CONSULT THIS REPLACEMENT DISTRIBUTION FIELD: RECORD IN CASE ANY BUILDINGS,'DRIVEWAYS, SWIM. i NORTH /.t44•1 GaN Z0 orl -� MING POOLS, OR EXTENSIVE GRADING OR FILLING ARE fav�} LATER CONTEMPLATED. f r SHRUBS OR TREES SHOULD NOT BE PLANTED CLOSE TO �'� ?a te 5 J. M� THE SEPTIC TANK AS THEY WOULD INTERFERE WITH Ft) A 4 CLEANING OF THE TANK. THEY CAN BE PLANTED IN THE DRAINFIELD AREA PROVIDING WILLOWS ARE NOT USED. ,----, !2 �‘ THE YARD GRADE IN THE DISPOSAL AREA SHOULD BE SUCH /� T,S, ,4. THAT SURFACE WATER IS NOT POCKETED ON THE DRAIN 1� ya ''t('.� '0 4", FIELD. ANY SETTLING OF THE GROUND OVER THE TREN• •-s'►�.,py-.2 , CHES SHOULD BE FILLED IN WITH SOIL. DO NOT EXCES• -,,�.� G SIVELY WATER THE LAWN IN THE DRAINFIELD AREA. • �,o� WATER EVAPORATION FROM THE DRAINFIELD IS ABOUT EQUAL TO ONE HALF INCH OF RAIN PER DAY. FOOTING DRAINAGE, DOWNSPOUTS AND WATER SOFTENER RECHARGE WATER SHOULD NOT BE CONNECTED . INTO THE SEPTIC SYSTEM OR DISCHARGED INTO THE DRAIN, • — '��i140- 1 iJ FIELD AREA. f THE TYPES OF BACTERIA NEEDED IN A SEPTIC TANK ARE � 1�e ^` ALWAYS FOUND IN SEWAGE. THERE IS NO NEED TO ADD YEAST OR OTHER STARTERS TO A SYSTEM. THE USE OF RE- JUVENATORS OR CHEMICALS TO CLEAN A SEPTIC TANK -N , T�"'l HAVE NOT BEEN PROVEN TO BE BENEFICIAL AND MAY o BE HARMFUL BY FLUSHING SOLIDS OUT OF THE TANK OR tca ,y 3, BY CHANGING THE CHARACTERISTICS OF THE SOIL. THEet N.: SOUTH NORMAL USE OF BOWL CLEANERS OR CLEANING COM• POUNDS WILL NOT KILL THE BACTERIAL ACTION OR SLOW DOWN THE OPERATION OF THE SEPTIC TANK. 20 _2I j')') < _ ��(( ~ APPP`ROOVED BY DATE \ 'n _ — THIS IS AN IMPORTANT DOCUMENT y - 2'1 - f�""'' JI,Wip-I DEW R O'HER- ;; ;; '' rt,rk PATE CERTIFIED BY �: . „�1«fi. 1SSENTIALIkLE1�S! 4 ,''A.rt4S Limo ©r .;.¢'I(t=::;:i )!iiii'• ii.b;-.- .:'.?'it:i.ti ,..,MS y., 1 . • k.4001) . 7.qn/ AL • i v14,71 4 Pwi lo I It 5r Fia 6- L- ; '$1Z-, I 4) 4' „-- Ce Printed From Mason County DMS Printed from Mason Courty DMS INFILTRATOR septic tar:Ks Features&Benefits • Strong injection molded polypropylene construction I + • Lightweight plastic construction and -..- inboard lifting lugs allow for easy delivery and handling ( 7 �j , ` Integral heavy-duty green lids that rT�� (/(, g vy- uty PP f' 1 interconnect with TWTM risers and pipe riser solutions KKritcrtrrtIttttlit at It K K W al NUM r r 0 •t r • Structurally reinforced access ports eliminate distortion during installation . and pump-outs • Reinforced structural ribbing and fi fiberglass bulkheads offer additional strength • Can be installed with 6"to 48" of cover The Infiltrator IM-1060 is a lightweight strong and durable septic tank. • Can be pumped dry during This watertight tank design is offered with Infiltrator's line of custom-fit pump-outs risers and heavy-duty lids. Infiltrator injection molded tanks provide a • Suitable for use as a septic tank, pump revolutionary improvement in plastic septic tank design, offering long-term tank, or rainwater(non-potable)tank exceptional strength and watertightness. • No special water filling requirements Inlet Side are necessary - • The tank may be backfilled with suitable TANK CUTAWAY Infiltrator _ native soil. See installation instructions _ TW Riser - System---------.__ ? tti for guidance. Partition • baffle wall • r HEAVY DUTY LID ` CUTAWAY Reinforced . !. - 24" structural access port • I I ..;> \ Structural p�+= I ----" bulkheads MID-SEAM CUTAWAY / Reinforced water tight mid-seam M � gasketed connection ,.f 11 a fi, ddiL.l- t. . ir Protecting the Environment with Innovative Wastewater Treatment Solutions INFILTRATOR" es -__ 9 water technologies • IM-1060 General Specifications and Illustrations -LIFTING STRAP LIFTING LUG RISER CONNECTION (TYPICAL) (4 TOTAL) / (TYPICAL) The IM-1060 is an injection molded two piece mid-seam N 1►JV ��, plastic tank. The IM-1060 injection molded plastic design itil l I I � k allows for a mid seam joint that has precise dimensions A i for accepting an engineered EPDM gasket. Infiltrator's t are, °o �'t t �r�°o ,�11 } gasket design utilizes technology from the water industry , , 1�a Q:' . ° b ii. 1662 21, to deliver proven means of maintaining a watertight seal. ` a1:C o°,�� i r i i iL.. o° ;E ; E`, PoOR ' .`.0, WIDTH The two-piece design is permanently fastened using a ,ci= _ ��, series of non-corrosive plastic alignment dowels and �a�I� P!"� RAW I � locking seam clips. The IM-1060 is assembled and sold 110. ��_ "' through a network of certified Infiltrator distributors. 1 270(32261 EXTERIOR LENGTH Must be backfilled and installed in accordance with TOP VIEW Infiltrator Water Technologies, Infiltrator IM-Series Septic Tank General Installation Instructions and for shallow ,_ ground water conditions reference the Infiltrator IM- Series Tank Buoyancy Control Guidance. iii!AJ! 11IA1ifcc — — c Please visit www.infiltratorwater.com/images/pdf/ --- - - -- --�-" (13891 ManualsGuideslTANK01.pdf for the latest information. WWII �1Y n hI �"—IlrrGHR SEAM CLIP (TYPICAL) �/ IM-,moo 41JLIFTING STRAP Working Capacity 1094 gal(4141 L) (TYPICAL) Total Capacity 1287 gal(4872 L) END VIEW Airspace 16.5% Length 127"(3226 mm) 04[102) 02416101 ACCESS OPENINGS WITH LOCKING LIDS(2) PVC OR ABS 04[102)PVC OR Width 62.2"(1580 mm) INLET TEE -10.2[260)FREEBOARD ABS OUTLET TEE Length-to-Width Ratio 2.3 to 1 ( INLET i y AIRSPACE 1 ounET S Height 54.7"(1389 mm) rIPER 1 [7fi i PER COpE CODE Liquid Level 44"(1118 mm) 1/11 ,,.o[1118 I Invert Drop 3"(76 mm) SUPPORT SSJ• LIQUI SIBPPOLTSS LIQUID ..-SUPPORT '--_ - -_--__- - - - (TYPICAL) DEPTH (TYPICAL) WITH BAFF LE -I Fiberglass Supports 2 WALL WHERE REQUIRED Compartments 1 or 2 Maximum Burial Depth 48"(1219 mm) SIDE VIEW Minimum Burial Depth 6"(152 mm) Maximum Pipe Diameter 6"(152 mm) TANK TOP CONTINUOUS Weight 320 lbs(145 kg) HALFI -- GASKET TANK eat INTERIOR F` SEAM CLIP �4 ALIGNMENT Cr (/EEII/�// TANK BOTTOM 4 Business Park Road HALF P.O.Box 768 DOWEL Old Saybrook,CT 06475 INFILTRATOR. 860-577-7000•Fax 860-577-7001 1-800-221-4436 MID-HEIGHT SEAM SECTION water technologies www.inilltratorswater.com U.S.Patents:4,759,661;5,017,041;5,156,488;5,336,017;5,401,116;5.401.459;5.511.903:5.716,163;5,588.778:5.839,844 Canadian Patents:1.329,959;2.004.564 Other patents pending.Infiltrator,Equalizer. Quick4.and SideWinder are registered trademarks of Infiltrator Water Technologies.Infiltrator is a registered trademark in France.Infiltrator Water Technologies is a registered trademark in Mexico. Contour,MicroLeaching.PoyTuff,ChamberSpacer,Mult(Port.PosiLock.OuickCut,QuickPlay.SnapLock and StraightLock are trademarks of Infiltrator Water Technologies. PolyLok is a trademark of PoyLok,Inc.TUF-TITE is a registered trademark of TUF-TITE,INC.Ultra-Rib is a trademark of)PEX Inc. ®2016 Infiltrator Water Technologies.LLC.All rights reserved.Printed in U.SA. IM02 1116 Contact Infiltrator Water Technologies' Technical Services Department for assistance at 1-800-221-4436