Loading...
HomeMy WebLinkAboutFIR2007-00035 - FIR Plot / Site Plans - 9/17/20070 TRUSSES © 24" 1 z LIVING 0 T WO ROOM D ST / 1 OVE 11/4 • 1 • ttx a 0 0 0 c 0 J 0 X KIT CH�N 1 V4 31x9I PARALLAM 1 1/4 MECH. OPEN TO ABOVE 51/4x16 PARALLAM 1 Y4 cc tr UJ 0 rY N. CUSHMAN 6" ELECTRIC BELL ►Q (WIRING BY OTHERS) PUMP CHAMBER DIN ING R OOM ,�. MAIN FLOOR NORTH �/a' = 1 " 0" 16'x11/4" POLY (INSALLED BY OTHERS) %PROPOSED NEW RESIDENCE SYM TYPE HEAD 0 �� SITE PLAN NORTH NTS SPRINKLERS BATH BEDROOM • 1 /0 1 1 1 - 1 1 / / BATT TYPE INSULATION INSTALLED OVER ALL ATTIC PIPE (BY OTHERS) /1/1/111/11111111114 DINING ROOM LOFT BEDROOM 6 0 N i'', 0 VANU. TRUSSES C Z 0 V 0 0 0 e- a-- ,l 1 C / / / Mr OPEN TO BELOW 7,._IIIIIIM' • 1 A UPPER FLOOR NORTH 1/a' = 1" 0" LOFT BEDROOM KITCHEN SECTION CUT "A -A" 1/4" 1" 0" r GENERAL NOTES 1. ALL MATERIAL AND INSTALLATION TO BE PER NFPA 13-D 2. ALL PIPING AND FITTINGS ARE CPVC, EXCEPT RISER PIPING WHICH IS ALLIED "DYNATHREAD" WITH C. I. FITTINGS 3. ALL HANGERS ARE TOLCO FIGURE 22, 23, OR 24 WITH 14" HEX HEAD LAG SCREWS 4. ALL DROPS TO HEADS ARE 1" CPVC WITH HEAD ADAPTER 5. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPING FROM FREEZING 6. INSTALLATION AND TESTING PER THE AUTHORITY HAVING JURISDICTION HANGER SPACING FOR CPVC PIPE Y4" PIPE - MAXIMUM OF 5'-6" 1" PIPE - MAXIMUM OF 6'-0" 11/4" PIPE - MAXIMUM OF 6'-6" SPRINKLER SPACING MAXIMUM SPACING FROM WALL IS TO BE 8 FT. MAXIMUM SPACING BETWEEN SPRINKLERS TO BE 16 FT. MINIMUM SEPERATION BETWEEN SPRINKLERS TO BE 8'-0". WATER PRESSURE GUAGE DRAIN VALVE ELECTRIC W. F. SWITCH (WIRING BY OTHERS) 0— 1 Y4 TO SPRINKLERS 6-HEAD SPARE BOX 1 1" AMES MODEL 2000B BACKFLOW PREVENTER --15c34:25--6DOMESTIC WATER (BY OTHERS) RISER DETAIL NO SCALE FIN. FLR. SUPPLY (BY OTHERS) HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE CPVC SINGLE FASTENER STRAP TYPE HANGER (1) FIGURE 22 — CPVC HANGER TOLt;� HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE CPVC DOUBLE FASTENER STRAP TYPE HANGER FIGURE 23 — CPVC HANGER L_ HANGER DETAIL NTS Fitt �,Q,p V MASON COUNTY t.' FIRE ; . Sj AfL D aT: �_�-0 BY S iR :.,. :..r 7 O i`I3.�.._L INSPECTION I,ifF ALL APSLiCAEL CODES SHALL APPLY. ERRORS AND/OR OMISSIONS ON PLANS ARE SOLE R_- SPO`:SiOLITY OF OW'NEE/CC;NTRAC CIR_ CORREC- TJOdS REOU1RED FlOM FIELD ',?ISPECTSON 2E AT CWNEP./CONTR. CT O '3 TH:S :AP- PROVAL DOES NOT ..-....•sT TO ANY FERSOH Ti-LE n.vrrI TO e.i.._.}.: ANY CITY OR STATE 0 FIRE PROTECTION SYSTEMS, INC. 23220 MAPLE VALLEY/BLACK DIAMOND RD. S.E. — MAPLE VALLEY, WA 98038 SUITE 3—D 425-432-4401 CONTR. UC. ACEFIPS147P1 ACE J UPRIGHT ON UNE MODEL MAKE SIZE TEMP O 0 • • UPRIGHT ON 1" STUB UP PENDENT ON UNE PENDENT ON 1" DROP UPRIGHT & PENDENT ON 1" DROP DRY PENDENT LFII TYCO 155 FINISH BRASS ESCUTCHEON QTY WHITE FLAT CONCEALED 11 1 EARTHQUAKE BRACE FLEXIBLE COUPUNG RIGID COUPUNG REDUCING COUPLING LEGEND —H FLEXIBLE COUPUNG do CAP SCREWED CAP —4 PLUG —e— FLOW RISER —o— FLOW DROP 0-0 t. PIPE TO BOTTOM OF DECK O - WELD PIECE NUMBER HANGER LEGEND #1 - U—HOOK W/2 NO.16x2" DRIVE SCREWS FOR 1"-2" PIPE OR LAG SCREW PER NFPA #13 FOR 2-1/2" AND LARGER PIPE #5 — EYE SOCKET W/3/8" x 2-1/2 LAG SCREW, A.T. ROD do PIPE RING #10 — EYE ROD W/ LAG SCREW PER NFPA #13 & PIPE RING #12 — TOP BEAM CLAMP, A.T. ROD & PIPE RING SYSTEM DESIGN CRITERIA PER NFPA 13—D LIGHT HAZARD WATER INFO: STATIC — 60 PSI RES — 45 PSI PROJECT SPENCE RESIDENCE 2190 W. CUSHMAN RIDGE DR HOODSPORT, WA CONTRACT WITH CHRIS SPENCE 6408 NW 170TH CIRCLE RIDGEFIELD, WA 98642 DRWG. TITLE 4 SIDEWALL TOTAL SPRINKLERS THIS SHEET 11 / HANGER LOCATION O HYDRAULIC REFERENCE POINT Q PIPE TO FINISHED FLOOR GPM — 36 GPM FIRE SPRINKLER PLANS DATE 9-10-07 DRAWN BY TK APPROVALS BY MASON COUNTY REVISED SCALE AS NOTED CONTR. # 07-2855 i OF