Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SWG2023-00125 - SWG Application / Design - 4/3/2023
415 N 6TH STREET,SHELTON,WA 98584 4I1AMASON COUNTY SHELTON:360-427- ,EXT 400 BELFAIR: 360-275-4467,EXT 400 t(�i ELMA: 360-482-5269,EXT 400 Public Health & Human Services FAX:360-427-7787 On-Site Sewage System Permit: SWG2023-00125 APPLICANT LE ET AL HUGH H Phone: Address: 11336 SE 192nd St RENTON, WA 98055 OWNER LE ET AL HUGH H Phone: Address: 11336 SE 192nd St RENTON, WA 98055 PAULA JOHNSON -Arrow Septic Phone: 360 898 2255 SEPTIC DESIGNER Designs Inc. Address: 171 E VUECREST DRIVE UNION, WA 98592 SEPTIC INSTALLER Shane Maples- MAPLES EXCAVATING Phone: 360-463-8474 Address: 911 SE Arcadia Road SHELTON, WA 98584 Site Address: 17721 E State Route 106 Primary Parcel Number: 222125800040 Permit Description: Table 9 repair 2bd OscarXO2 Permit Submitted Date: 04/03120230410612023 Permit Issued Date: Issued By: Rhonda Thompson Current Permit Fees Paid: $780.00 (additional fees may be required upon installation of system). Permit Expiration Date: 04/04/2024 (based on date of inspection) Permit Conditions: 1 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 3 Drain field installation not to exceed designed upslope and downslope depth specified on design form. 4 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 5 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. 6 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND E EASEMENT NT DESIGN THE SITE WAS THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED EOCCUPANCY OF ANY RELATED STRUCTURES. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL For Final Inspection visit: masoncountywa.govlhealth/e 400 tal/onsiteloss-inspection-request.php or call: 360-427-9670, extension OFFICIAL USE ONLY '' `.;->. MASON COUNTY DATE RECEIVED- 9 J I -5 / g.,.7) . D ,IOWCOMMUNITY SERVICES AMOUNT V b0 RECEIVED BY:q o CA Public Health(Community Health..Environmental Health; /� "���� C cn 41;NDth Stc et•51,or i,WA:5 5134 exr..00 S W G ' -N (n O 475 N.tHh Street•$txhon,WA 3°SB< (-/`(UP/` - cc \ Z 05 ON-SITE SEWAGE SYSTEM APPLICATION m APPLICANT I PHONE m Hugh Le & Maily Nguyen (425)420-3168 Z MAILING ADDRESS-STREET CITY.STATE.ZIP CODE0,igum,)17171-547' A— 11336 SE 192nd Street 1,1 Renton WA 98055 CD SITE ADDRESS-STREET,CITY,ZIP CODE (--( APR 0 4 2023 L 8 17721 E State Route 106 Belfair WA 98528 a I N) NAME OF DESIGNER BY ,,BONE -o N) Arrow Septic Designs, Inc (360) 898-2255 NAME OF INSTALLER PHONE o I N Maples Excavating (360) 463-8474 PERMIT TYPE(select one/ DRINKING WATER SOURCE 0 RM tn-J RESIDENTIAL OS ECOMMUNITY OSS E.COMMERCIAL OSS 55 PRIVATE INDIVIDUAL WELL 6 PRIVATE TWO-PARTY WELL Z I N BP_? TYPE OF'WORK(select one) PUBLIC WATER SYSTEM Lakewood Plot IX I ENEW CONSTRUCTION I UPGRADES IX REPAIR I REPLACEMENT OTHER DETAILS;sere:;ail tnat apPV EA TABLE IX REPAIR I (71 SUBMITTALS 0 SURFACING SEWAGE 0 EXISTING FAILURE 21 SHORELINE DESIGN FORM(REQUIRED) O?SEPTIC DESIGN(REQUIRED) BEDROOMS _ SIZE W ( E co EWAIVER(S)(IF APPLICABLE) 2 i .78 Acre t DIRECTIONS TO SITE AND SITE CONDITIONS.(ex poked gate/ I O : Take Highway 3. Turn left onto Highway 106. On the right/water side, #17721 will be on a I o gray garage with a red door. Take gate/stairs on the left side of garage to septic location. b I O I -4' cn SITE MUST BE FLAGGED FROM MAIN ROAD AND TEST HOLES MUST BE FLAGGED WITH TEST HOLE NUMBERS. I Q OFFICIAL USE ONLY BELOW THIS LINE UPGRADE/FAILURE SOURCE(for reporting purposes) 0 VOLUNTARY 0 MAINTENANCE/PUMPING 0 BUILDING PERMIT ['HOME SALE ['COMPLAINT 0 OTHER: INSPECTOR SOIL LOGS COMMENTS/CONDITIONS -9-\-- .1;\-( 0 -3 t v► k- , -g b-r-Posfirwl 2 ' 0 -3 6 cyv S i 36+ bo t%0-J : 0 - ull t/vvv5 i \-1, k 4- N-41-, RECORD DRAWING AND INSTALLATION REPORT SOIL CODES: V=VERY G=GRAVELLY S=SAND L=LOAM Si=SILT C=CLAY E=EXTREMELY R=ROOTS REQUIRED FOR FINAL APPROVAL. INSPECTOR SIGNATURE DATE APPLICATION EXPIRATION DATE APPLICATION APPROVED/ISSUED BY DATE C\AAA/fW �k1/-L5 I (-4 1 VI 41\4th 447- 5 MASON COUNTY WEBSITE REVISED 12/7/2015 THIS FORM MAY BE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON THESO DESIGN FORM—PAGE ONE Assessor's Parcel Number: 2 2 2 1 2 — 5 8 — 0 0 0 4 0 A design will be reviewed when 3 conies of each of the following are submitted: Completed design form that has been signed and dated. ''Scaled layout sketch,including all applicable items on checklist '"Scaled plot plan,including all applicable items on checklist. 4#Cross-section sketch.including all applicable items on checklist. This form may be scanned and available for public view on the Mason County Web site.:tfaxinrm paper size: II .>i 17" 4''C "'r',,M ;:74A _;za PARCE1:W ri1 1CATIO ':. M t at Permit Number: SWG 2C ..3—00k.a, Designer's Name: Arrow Septic Designs, Inc Applicant's Name: Hugh Lee&Maily Nguyen _ Designer's Phone Number: (360)898-2255 Mailing Address: 11336 SE 192nd St Designer's Address: 171 E Vuecrest Dr Renton, WA 98055 Union, WA 98592 Ci State Zip City State Zip . g , :. " =DESIGN.rARAMETERS I' , Treatment Device ❑Glendon Biofilter 0 Sand Filter 0 Mound 0 Sand Lined Drainfield 0 Recirculating Filter.Type: Ctil'Aerobic Unit Make Model OSCAR X02 0 Disinfection Unit Make/Model Other: Drainfield Type ❑Gravity RiPressure 0 Trench ❑ Bed ( Sub Surface Drip Septic Tank/Drainfield Specifications Laterals Number of Bedrooms 2 Schedule/Class Netafim.42 gph Daily Flow:Operating Capacity 180 gpd Length 25 ft Daily Flow:Design Flow 240 gpd DP b. C ICII WIC O .66 in Septic Tank Capacity(working) X02- 1,000 gal N+1i ber ��pp 5 Receiving Soil Type(1-6) 3 Separa?tJnR 0 4 2023 .5 ft Receiving Soil Appl. Rate 0,8 gpdlft2 Required Primary Area 300 2 BY'-------------Orifices ft Total Number of Orifices 50 x 5=250 Designed Primary Area 300 ft' Diameter emitter in Designed Reserve Area 300 ft2 Spacing 6 Trench/Bed Width 10 ft in Manifold Trench/Bed Length 30 ft Schedule.Class 40 Elevation Measurements Length ft Original Drainfield Area Slope 0 % 30 Diameter 1 New Slope,If Altered in 0 % Preferred manifold configuration used? gYes 0 No Depth of Excavation Up-slope 12 from Original Grade in Transport Pipe Down-slope 12 in Schedule/Class 40 Designed Vertical Separation 28+ in Length ft Gravelless Chambers Required? 0 Yes 80 q �No CI Diameter 1 Pump Required? in �Y'es 0 No Dosing and Pump Chamber Pump/Siphon Specifications Number of doses/day 411 Diff.in Elevation Between Pump& Uppermost Orifice -20 ft Dose quantity .59 gal Drainfield Squirt Height/Selected Residual(head) — ft Chamber Capacity(flood) 2-comp- 1,000 min gal Uppermost Orifice 0 Higher EtLower than Pump Shutoff Pump controls: Please check those required. Capacity @ Total Pressure Head 7.8 gpm EeTimer IRrElapse Meter 5fEvent Counter Calculated Total Pressure Head -15.80 ft If Timer: Pump30 sec Comments on .Pump off 3 min DESIGN FORM—PAGE TWO Assessor's Parcel Number:2 2 2 1 2 — 5 8 -- 0 0 0 4 Q` Permit Number: SWG DESIGN CHECKLISTS Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch It Test hole locations Gd Drainfield orientation and layout Reference depth from original grade: g Soil logs g Trench/bed dimensions and g Septic tank g Property lines critical distances within layout Cif Drainfield cover 6d D-Box/Valve box locations ❑ Existing and proposed wells Reference depth from original grade within 100 ft of property g Septic tank/pump chamber and restrictive strata: g Measurements to cuts.banks.and locations g Laterals,trench/bed,top and surface water and critical areas g Observation port location bottom ❑ Location and orientation of g Clean-out location 0 Curtain drain collector curtain drain and all absorption g Manifold placement 1 ' Sand augmentation components RI Orifice placement Other cross-section detail: El Location and dimension of Lateral placement with distance gObservation ports/clean-outs primary system and reserve area to edge of bed Other Information Pi Buildings g Audible/visu•.'".trm referenced Yes No 66 Direction of slope indicator g Scale of dr *..•_ .4 •wn on scale g 0 Design staked out ❑ Waterlines bar 0 I�Recorded Notices attached �" .� ❑ g Waiver(s)attached Roads,easements,driveways, Itir 'o• "4•4,parking �t� �� ,..4;4 II ❑ Pump curve attached ��i• �!� '.s'�;' l 0 Evaluation of failure g North arrow and scale drawing !!,q ,04 shown on scale bar %••• 5104349 Non-residential justification N.or PAULA JOY JOHNSON 1' S b ❑ E1 Waste strength L'iCIS b iGN 0 It Flow c1[viREs 1 DESIGN APPROVAL The undersigned designer must be n • ied by in Ilex time of installation g Yes 0 No `\ 4-3- z,3 Signature of Designer Date The undersigned has reviewed this design on behalf of Mason County Public Health and determined it to be in compliance with state and local on-site regulations: 1416 1 I i 6 /V2) Environmental Healt Specialist 6 Date CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDITION: ✓ The design is stamped"Approved" by Mason County Public Health. tdtlk 171L1 ✓ The Onsite Sewage Permit has not expired,the Permit Expiration Date is: ✓ Drainfield site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. This form may be scanned and available for public view on the Mason County Web site. Updated Date: 12/7/2015 Arrow Septic Designs 171 E.Vuecrest Dr. Union, WA 98592 March 30,2023 Mason County Department of Health Services 415N6thSt Shelton,WA 98584 RE: Hugh Le&Maily Nguyen Property(Parcel#22212-58-00040)Septic Replacement/Upgrade Dear Inspector: Belfair,WA ade septic design for a property located at 17721 E State Rte 106, Attach 98528. is a replace existing 2 p locatedn 1 the The Muse has anide isthe ' tin 2-bedroom home built in 1979 and remodeled in 2018. house has existing gravity There isy an exis g septic system ivnstall;ift pump for the basementplumbingarea house,so there is a sewage water. The At a e of its age, a full upgrade is needed. Thea ere must be owner service visit in March-2023 it was found that one of the two grainfield legs was not taking owner has been having issues with a t eepstaiic rcased ecau accessed from Hwy 106 above by P o be The 2-bedroom tank is o be de commissioned or removed and the old drainfield is t1,be0 gal o 2do The proposed allon minimum 2-compartment discharge tank. It is recommended to use a 2-bedroom replacement system will be an OSCAR X02 and will include a new treatment tank,followed by a 1,000-gallon tank for excess surge capacity on this project. 1,200 to 1,500 gallon oversized discharge replacement drainfield is 300 s.f. of OSCAR at-grade drip teldhe OSCARsing an dapplication dug The ofop8sed rate of 0.8 in a Type 3 loamy sand soil. Because of excess vertical separation, flush with the original grade. This will protect it from foot traffic and erosion as it into the ground and installed To be conservative,weproposing 5 OS-50 coils in the drainfield at isright and not the existing full 62.5 bulkhead. allowed with the OSCAR X02 system.There will also be a new control a gad and using the ineter gp panel with a timer,elapse meter and event counter to facilitate future operation and maintenance. aint than25' to the less in meets Table IX repair level Ads with the new proposed withou disinfection, and over 24"d vertical separation. We have also bulkhead in Type 3 soil,treatmente is on a water system and there are no wells nearby. designated a reserve drainfield area. The pro p rh' The property owner's contact information is as follows: Hugh Le&Maily Nguyen 11336 SE 192"d St Renton,WA 98055 (425)420-3168 If you need further information,please contact my office at(360) 898-2255. Sincerely APPROVED • to APR 0 6 2023 P, ��, . , MASON COUNTY ENVIRONMENTAL HEALTH Xi! erase 'te water Treatment System Designer RET 5100349 �Y) � P.AULA JOY JOHNSON'•. Vi I'G1dE'fi( 1�155/,' _ • , . • a -\\ • 4 `; ~ . .,aocnTv r Ciar..Y. ��y�nn/��jj��'�9'' // • - �i , . K •OPLRT 4 5OP/3C' wuaeorra 7M/J P/Y / !I!..* t G')PY/Yi"ILL o•�•ovvrnemr CS e. erwnareO*WO :Ix • LwKCNoeD PLOT"L'C R N.,Vn ,,•- /r.".r..iorrrrr ,:1�'V/f A +. • , •�7/ar/2,?boa gm,M..N. en(:•/ t ' 4LDiCfJT/O�Y a, �f ,rtI • rNe ImSO NH'LA rr,,P qnU.WAQOrto 7N.J .Y/feV Pte ACM ar TNCJr A•LJM•Ti TNNT Ve• Y]7 `.� Q / .wnM ✓eMT[lTf..ne"worry,*�:NG cLo w�tieeYivcisreo,rimer / // C k ! ywGSRI fee SISAL* L So rat PT o^Re CNI/RM.Ifr.eylt0 01 ,y GCctwRL 7N/J PLOT"ILL'T tt Y l/t'.PLACES afO c0!�'T/<>�7ePi< ,' / '�" Peae* LASE4•e.ILL iTRIRTJ.N eM f��L[ /f/ iGV.0.7 On r fl TJ C•W>w g, IWGVZit&De TNCNCORroe Oefr - f rNA RLAlFJT O^ C�/� ,, �� � .".,D iwvM On a ce,•03 N•TTWA r/ TN/ aYO^ V�4 /J a•..I::: . Act PVDIJC PDRPOJGJ,ILJO IL, PWeer Tire LVS LL / wrJJ J/Ml/'TCe / ' "r NLCe",,TA cri•e /Ot••••cvr OR//LLJ�roe i ,•' Ct ..zjMDRCb'OR ,�[[ 5.3a.e O IRowa.er 13WW )'Y M SNAG PL.7'rr I 4Z ,pfwLL OTRGLTa•wYt.,'(/GJ•P( G.x N.aT y/UAW*,, ✓wJNM'•TO+rROLr pQ/•N1NL GRROr>Q ALCoR _; e7c,DNeM'>.eweaT. aecoaoJ o•-nwJOM cptNYrr. _ /P, a� a ' _.. /n✓/r ✓•veR v^ier eua Nlnna /•'r .a)o.xwca SNAG r ../ ..e. a+;® : . li; 'I ''''Ii- '''' . O rTNL MNo.'uer P^ � . G cw+..TY �/6 /� a``I + f x t ,� � 1.� !' ._ _ fNe urTd�•eiMo•= V /S`�V' TTT r f : • c •nrr e..nwiw /I"�"C.r of Ie+cev Gdor/vGe s+wf c1 a/ / � „ x �P'a • air, 'I 7..• :roee4rr:rNlr _.'Z/6n M7o•• - Iu"4:gt• LGri 42 f /1' 'p. i /A7Y" /MC'J^e(r wct�owq� rwc viT:vwvar T4.4‘..(2) J �ly _ o SMORee T�Ad Anor-Aa<o✓e D.oTLerr "ae/L-'OnrrC.wlCtU0' / ._. n/� ,veciwlkt/ fuLLV A a eeaT :/� Y .i rr e •J` •]wo nRfteTT.NOJer.10 w.r0✓/fe 7C.Te••N rt R/DJ7...I / /N ee rA•2 //NLC VNo efeGKeo 272 , „rrorust r Pw/o /CAI of lwo wc.rro✓crouo Tv/r Trwr rw �� i !t • +••••••w iyrJew[ro swc SA••r IJ rw•eid face I n exyvr'•ado f/ •J (� _ �.- . Rwo oeeo row>we(/iti w/rC wvPox yI...1• •ir' ✓nMC.ea/.YN..W/ free C/r/c AL JUL N<o, rye...~sew.J!/cq . a$/J ,/`•+ ;``.1 I± .� ^!(�'- �• .•l, s •: .. .(.. RMe YCIR I/RJr.,COVC kW/freer.TYM. ' "✓IJNMI Rw. `�^/ 11 re%I l\ ")- ` +4 r 'err M ar.iaT1s,• `C`\_ 4 f�r = J�/,r' j i• �F •.''(. , 11M idE((i12t' r. q .,w �)_j / <t !! h� K '^<• v` •' s . ' •UY6/!f'Ll' 0 SF/r/GA?'IG m ar�..•r �3 • J"f',�/ ®At :IF . r \ i h:..,<I '• ! , .... y `, /nt. u GOYT/M'TNw7 7i7L PLN7of LIKE o/• Gl ,. ti/, / • , DIJf1!uNW.wN.ner M, a lrer.rnp r veer.✓n•.f-.4r �t'�f •. J,! l'-f .�•J' ' _ iecnew.e,r.wiN/P 2r rrorT+r, °, o® �'� /tt 4•i.•+ t )• I ,nse airw.reei.7M Rcer,TART OW i Yea O t� /t��' ! � • .. "'! 4 /' .•. ,,!y 1. l�� ,MD CLOCK CogneRi iTNK00 on rne'e , 1 �C x,r :C./L L.MN/eeK ff ` N. a•'/ 1 I .. • - s,.� + I.. .• `; Off. o'/ , O 4 I 1 • /YOTG' �c ..ase..a f '44Y� " a' 4 ' { at,.<osa..a Jwr+rrren�+•oeR Lowe 7e .f i�' `�p "4,, �/ } TROIT OOY�R rrf ONR✓OI` Sibh. . i 3 Y rve uorev>w'"-rtcvr 4,,,c'J, 7R• 00 i• .. /'` „d i JNiD sett GO S.�" �,t ny s .r1. . t • . 5\ ' „a•® ". . -,,, Ne „- , ,...v. % i ' 4ng,...,... ,IPT . ...., ..31 k ' e: % .., - ,'' .. t \',140 i \ . f-a-.... - .0„- ,or!-- 4rt" .. „,e-- , It le e i. r . NQl y'� tR \\-r 7 i • • • • `,�• ,...+,. t .."..e;104, A4 1 ► • .... ...• a I. •. Na... .rar.ava= .v.+7 i../+Y...7 " • APPROVED APR 0 6 2023 MASON COUNT`(ENVIRONMENTAL HEALTH RET 1\400 N k1.._. q....--"I'df aa, _ V to'X 30' 1 c X 30. 1 occARv 1 G S G{a ORAtrIf lE' I_ _ _ _ — —4V7-----------------------N vow -■ 2gg �{6t,�s� z2g'a ti•• s_ © ri �C �J f kosm tz Ink °© 0 K; ti ts St�E° —� w O � _ — Q ; L ti t I IS 'am N OS11. wow `t WOO" z 9 4 5-Lbt - s p Q1v E vs`A`J d' Sit`' MININIm ci � A�e Rpul. l 0 tW^ Cantrol Panel with Audio-visual Alarm 10��� r s� O O2 Cleanout T 1 {OL-E 1,000 Gallon Septic/Aeration Tank 1�s t'S 2-Compartment with air diffuser tits. a 1—-4-Z v o-�o. O 1,500 GallonanClarifier/l PpTan t JJ G t C 2p 3p q0 C �J N��I OS Headworks AN O OSCAR X02 Mound Drainfield tk WIS C 221.t2- "c04 0 ® A SS 7 t,,,.( �,b ,a , t- 5 � �Y to co 0 �� � ' 0/5. t, 7. •.1 MAe ••44;1 APPROVED 4 - ' APR 0 6 2023 +,0: PAULA JO•Y JOHNSON MASON COUNTY ENVIRONMENTAL HEAL TH ro .. RET • • LsCNS {�ESft3?it_ 4(9-fol a?..i,-6- T1--,s----s2,k.- -• OSCAR-X02 at- d rade ri C n calculations Friction Loss Calculations: F = L(Q/K)1.85 F=friction loss through pipe in feet of head L= length of supply line in feet Q= Flush GPM K=47.8 (1" sch 40 PVC pipe) Hydraulic Layout*OS 50 coils* (Table 2) Hy --- Flush GPM Excess TDH Design Flow Total Coils #of lats Coils per tat Dose GPM 50' 240 4 4 1 1.4 7.8 300 5 5 1 1.75 9.75 50; 2 2.1 6.2 50 360 6 3 2 2.8 9.2 50� 450 8 4 2 2.8 9.2 50 480 8 4 2 3.5 11.5 50' 600 10 5 Coils must be arranged in a single line APPROVED F = 80 (9.75/47.8)1.8s APR 0 6 2023 F=4.2 MASON COUNTY ENVIRONMENTAL HEALTH RET Total Design GPM=Flush GPM =7.8(from chart) Total Head = Friction Loss+ Elevation from Pump Tank to OSCAR Coil Drainfield Total Head =4.2-20=-15.8 (-15.8< 50' excess TDH—OK) Factory Timer Settings: 1,440 minutes per day/411 doses per day=3.5 min per dose cycle (incl. on &off) From Factory: 30 seconds On &3 minutes Off ,A, "47-.41) __A:. .'•?' _'-i't. ...thtiti • 1 r. 5,,cs49 .• Ye' PAULA JOY JOHNSON •. ExPIREs Tip 51 OSCAR at- rade dri drainfield desi n calculations Basal Area Calculations: Base Design Criteria: 240 gpd design flow, soil type 3 (0.8 gpd/ft2),flat site(<5%slope) Basal area required=daily design flow_soil loading rate 240 gpd+0.8 gpd/ft2= 300 sq.ft. Coil length=5 coils @ 5' diameter (5 x 5' =25')with 6" coil spacing 4 x 6" =2' Minimum shoulder width @ 6" (2 x 6" = 1') = 1' � 1' Minimum side slopes at 1 : 1 slope @ 6" (2 x 6" = 1 ) _ Minimu m basal area length= coil length+shoulder widths+ side slopes = 27' + 1' + 1' = 29' ...use 30' Basal area width= required basal area+minimum basal length =300 sq.ft._30' = 10' Basal area dimensions=30' x 10' (300 s.f.) Media: OSCAR drainfield: ASTM C-33 sand media: as per Washington Department of Health's Recommended Standards and Guidance for Intermittent Sand Filters. Supplies/Control Panel: • OSCAR X02 Control Panel: The LF1P-RF-AR or ARA control ps anel r the OSCARSX02 are operate veryshort and the The supply timed dosing sequencing of the OSCAR-X02. Timer very frequent(3 minutes off and 30 seconds on). ppI Y line needs to drain between doses,I line prior to each so the "on time" may need to be increased to compensate for filling the supply dose. APPROVED Each OSCAR-X02 unit will include: 6 2023 • LF1P-RF-AR or LF1P-RF-ARA control panel APR 0 �� • LOT-30, 1/2 hp, 120 volt pump MASON COUNTY ENVIRONMENTAL RET H^ `0 ' `' 'jh ' ` • Hi Blow Aerator, HB-80 (80 liter/minute) 'AP 'r.�� • Hi-Blow diffusers • OS-50 or OS-100 Coils rZ pAUTA51 JOg 359• Y,IOHNSON ' i PVC fittings and drip tubing adapters WIRES TL'ST- • HWN-.7-RF automatic headworks • Solid 1/2 inches poly tubing for connections • 2 float switches Headworks:HWN-.7-RF • 3/4 inches Arkal disc filter, mesh, 130 micron • 3/4 inches Arad flow meter • Three oil filled pressure gauges (0-100 psi) • 5 Netafim normally closed solenoid valves (Model 80) OSCAR Cover Options: he ed There may be a desire to cover the OSCAR with something additional to tspecifie dung too much C-33 sand. The intent is not to have too much additional cover over the final C-33 sand and other cover will inhibit plant root growth. Because the C-33 sa cover over the OSCAR d irrigated, At grasshe end of the first ground cover will grow rapidly,forming a firm protective growing season the C-33 sand layer will be as firm as native soil to walk on. Cover Options include: • Landscaping jute mat with grass seed or ground cover plantings • Thin layer of mineral soil low in organic content(<10%organics) • Thin layer of crushed or washed rock for wind erosion protection • Thin layer of bark or wood chips Do Not Cover C-33 Sand drainfield with: • Organic mix (manufactured top soil from compost) • Filter fabric OSCAR authorized dealer supply kit contact info: • H.D. Fowler, contact Jacob Gober or Dennis Groff, phone: (360)459-7300 • Ferguson Waterworks (Silverdale) contact Zach 7r Daryl 60-697-1510. • Iconix Waterworks, contact Kris Swanson APPROVED APR 0 6 2023 MASON COUNTY ENVIRONMENTAL HEALTH RET 4 N �i4' N Q I yz w 1 Si i F ■�! @0 ■ N I 0 0 6 J - au zc twig d -- M M XI ,I,_ C 0 Ir_r a .:'i':.::::::.:1'::::::• 'it.i:::.::::'::...:::::. . „, _ • I. z 1 _-1 Ii. ` J srR 1 C t F 1 1[ • H141M 1d5`09 APPROVED i APR 06 2023 - 0 c MASON COUNTY ENVIRONMENTAL HEALTH RET i- .. 11 M N O N N N N N O Z b W / W .. u i C4 t t.:,.z4.1-16Kigieti -15eTZ � �rr-K-,ice"'0 if,- - � t ' � ernes .i 'l r. d 1. ; \i _. -' r cl —.1114 t h � 'co oar ' ‘. 1 .i,f, fAa. �. I i ' `` It, p O Illj to, . .. .,2,.. t !t .. ,w1,. ..4 .1L:), \\ .. 1 , . ,... ,: !1,0: 1! res ••-,. ' .__•------.-,____ V;i ..----givi—i-7, ....2:ft• ____2____ _ .: -§" \ $.1 V C 7. i' U u II .,0- ` o VIo _• • z 't fTs i, 6.--. El-L. i \ / ' . t , .,\\\ 1 . \ \ , 9; Lo APPROVED • APR 0 6 2023 a MASON COUNTY ENVIRONMENTAL HEALTH o RET X02 TOttks immini ' t ___L.....__._._____-----_ _....._.___. _______„_. _ 11._ -1. I ,,,,----\\ (-----,,, a , .titt. 1 (7--,,,,, . ......!: it,in ii:i• ..-!-•. •1 L. =7...g::,• .(16...„:....). ; It j ....!....../ a - „.-- '\-.. t © i low Galion l000 Gallon: .. ______. 11-1W-7 '17-_- •.- -_ -:---7— . 11111..- ' . tie'', . . Ill Treatment tank Discharge tank Introduction: a tic The OSCAR-X02 treatment system is comprisedtwo systems: the and the OSCAR: coils,(C-33psand, chamber, aeration chamber, clarifier, and pump chamber) reverse flush headworks, and control equipment. Wastewater is collected in the septic chamber rated effl where oss solids are uent passes though the.The waste stream is aerated in the aeration chambers. I CBOD5 clarifier then into the pump chamber. The expected waste strength will be 30 mg/I 5 mg/I TSS. Effluent is dosed through a 120 mesh disc filter OCA toils, s ailed in infiltrating ASTM C-33 sand. Effluent discharged from the coils is treated by I the sand 1 priormg/ TSS, and 36 o reach 2 into the receiving soil. Final discharge Treatment Level Aected.The X02 tanks can only be used with FC/100 ml of effluent, meeting OSCAR coils. APPROVED APR 0 6 2023 MASON COUNTY ENYIRONMENIAL HEALTH RET 10g.k__.11 Design: The single family residence packages are designated as: OSXO2-240, OSXO Z-300, OSXO2-360, OSXOZ-450, 05X02 480, an4805X600 and and 600 gallons have t eay. corresponding design flows of 240, 300, 360, 450, ' Design flows The OSXO2-240, 300, 360, 450, and 480, are standard packages. greater than 480 gallons per day are considered custom and will require design from Lowridge Onsite Technologies, Inc. For the standard X02d single Can only be family assistance list see the append residence OSCAR-X02 package parts by Washington Department used with OSCAR coils. All tanks must be approved of Health. bined together as one. The system An OSCAR-X02 is two technologies 3500 gallons per day. The OSCAR has can be designed in increments of flow up to sizing criteria than the XOz. The XO2 is designed day (see Tablets ranging The differentrgallonsperdepending from 500, 750, 1125, 2250, 3,000, to 3,500 coilper day, OSCAR is designed in increments of 62.5 or 125 gallons per on coil model (see Tables 2 and 3). Consequently, a design for OS bedroom room system coils (840 gpd) would incorporate a 1125 gallon per day X02 plus (875 gpd). X02: Treatment Tank: The partition wash have a e4 inchn the f bytpasa hole oa second the bottom compartment of the treatment tank mu of the tee baffle located between n betwee0n the the firstliquid and second compartment of Discharge Tank: The Patricia the discharge tank must have a 4 inch by-pass hole located at least 18 inches abo ve the floor of the tank and no more than 27 inches between the bottom of the by-pass hole and floor of the tank. Recommendedhight Table 1-2 . Clarifier " - 1 660-670 3____ ___ __ 330-34080 Vm �- 660-670 -- r,�0 gpd -—-- -- 5001120 Um or more 1,000 750 180 Um or more 750 gpd 1 -.- -_ 750 1500 ' _ _ ------ - __- 1 1,500 I 360 Vm or more 1125 gpd 1,500 ; 3,000 __. 3,0001 1 �� ..-........__._. ..........1...... 4,000 i 2,000 � 480 Um or more 3,000 _ 3,000 gpd 4,0001_ —___'---�- � r 3,000 560 Um or more 3,000 4,500 - Spa APPROVED APR 0 6 2023 MASON COUNTY ENVIRONMENTAL HEWN R..T . . . _______________ ______________ .. 0 O J el e O 0 O 0-17-r-os-0-- . I E. 7 0 c6 1 2Di „poi o011 , < cildiii L•)-o Z 1-- Ir�,�I .',� O ± ± 0 imi* a to kt)) c6 ,,,,. c.1 i•lail * u._ vi:l tow iip.:D: (.1)1 .1 ail , 0 - - ii_iii :IL voin-L--ir 'mom" 0 ce o �- 0 APPROVED APR 0 6 2023 MASON COUNTY ENVIRONMENSAL HEALni RET SUBMITTAL DATA SHEET Thermoplasticli_ I 1 Reinforced Thermoplastic motor bracket and discharge with built-in with ourgA.Y.McDonald stainless bearing.This 1/2 HPsteel motors.Two wire ump has a stainless ;--1- , steel top bearing and motor coupling.These are assembled single phase models include pump, motor,and 10' lead. A This four inch submersible is supplied with grounded leads meeting the National Electrically Code(N.E.C.)specifications. • The performance curve below will assist you in choosing the pump that meets your nee MODEL S E-30GPM APPROVED \ • APR 0 6 2023 00 \ E - 30 GPM MASON COUNTY ENVIRONMENTAL HEALTH B RET 300 :- _ ttI wermS HA I - 1 I - - 1 _ —I—...� i-r T I.... 200 is, ' • 1 _.i I I t _ 1 I i----1-1-1-4- li--.7 - _ r I i _ �. e a j.... 0 100 1/2 HP•4 SWAG I--_l..� -�•Nll� . - ' l ......_... Dose 20 25 30 35 40 4 Sim lex 0 5 10 305 40 50 60 70 0 Duplex. --__0 __ O. __....__._._ 60 80 100 120 140 160 Fourplex 010 FLOW GPM Specifications B Wt. Model HP Material Volts Phase A 10 94 9.53 23 LOT-30 1/2 , Plastic 115 1 EST.1154 McDonald -, SUBMITTAL INFORMATION - Stainless steel pump shell and pump shaft - Powered by A.Y.McDonald submersible motors 1/2 HP. ____j - Reinforced Thermoplastic diffusers and impellers - 1 1/4"FNPT Discharge - Thermoplastic intake screen and cable guard NO-LEAD:The weighted average of the wetted surface of this no-lead product contacted by consumable water contains less than one quarter of one percent(0.25%)lead. Lowridge Unite Technologies,Inc. Toll Free: 87 -476 8823 daveQlowridgetech.com oscaronsite.com P.O.Box 1179 Lake Stevens,WA 98258 A.Y.McDonald considers the information on this assembly drawing correct when published.Item and option availability.including specifications,are subject to change without notice. 1/2022 Submitted by: V3 Ci ,X-1 . . Panel Wiring Diagram — =Feetorywire .... =Field Wire Model LF1 P-RF-ARA Quote#013023DC3 From Main Power Panel 120VAC,10.60 Hz. Main disconnect • 1.1 provided by others. PUMP SMC1 co 240VAC 10 GND ................L r 314Hp i 1.2 L1 3CB 20A SI N ® s--- ----' 1.3 1.4 From Main Power Panel 120VAC,10,60 Hz. Main disconnect provided by others. 1.50 BLOWER GND -........•..•..- 120VAC 10 r m ....._ ,/4Hp 1.8 L1 C:1 CB.10A CO T-...-....... © � 1 N 1.7 S BLOWER 120VAC 10 "" 1/4Hp 1.8 r 1.9 -,. BLOWER 120VAC 10 1/4Hp 1.10 1.11 1.12 OND ]_ L1 m — 1.13 N 13 CONTROLS __ 1.14 CB 10A LOGO BASE , LOGO S m CISIEMENIEMEN2-1F808-0BAt 1.15 1.16 High Level '0 ---.1.:- El 8 Alarm Timer/ 0 . •- El1.17 Redundant OP( al 1.18 1.19 APPROVE * o----4 1----•© ® APR 0 6 2023 1.20 MASON COUNTY ENVIRONMENTAL H; •LTH Push to Sience ElRET 1.21 1.22 HAND PUMP 1 SEMICONDUCTOR MOTOR CONTROLLER 1.23 oFF s� ® SIEMENS 01 3RF2150-1 BA22 �—nu�o 1.24 5 EDW-WD-OEM, , 1..26 Rev.1.0©02/09/7 Page 1 \4�l 2.1 HAND 2.2 • VALVE V1(S1,S2) •02 OFF A2 RELAY 2.3 • IDEC I —. RJ2S-CL-A120 2.4 a HAND• ® VALVE V2(S3.S4) OFF s3 03 • RELAY IDEC I I—"" � 25 • 'A�O RJ2S-CL-A120 2.6 D • VALVE V3(S5) RELAY OFF 54 0 A2 • IDEC "1""oa 717. RJ2S-CL-A120 2.7 UTO 2.8 29 1 LOGO EXPANSION LOGO EXPANSION DM8 2.10 • m 1 i SIEMENS 6E01055-1 FB00-0BA2 211 Q1 ALARM LIGHT (Q5) Ail IDEC 2.12 • I� © ` HW SERIES (06) ; AUDIBLE ALARM 2.13 • I---; • FLOYD BELL t SP-1081 """ .� REMOTE ALARM 2.14 0---C.c. O ® .-. (AHW OR EQUIV. 120 VAC ALARM) plll uann 2.15 j2,6 1,5 _ _ _ TRANSFORMER 2.16 Signal CL2-40-24 120V-24V 7 12 40VA 2.17 FUSE - _ 2A — 2.18 20mm CR1 � N/C 1 Common SOLENOID VALVE Si 2.19 114 6:J't 1.1 W 24VAC VALVE PROVIDED BY OTHERS 2.20 11111111 N/C 1.1 Common SOLENOID VALVE S2 2 21 . I•I { 24VAC VALVE PROVIDED BY OTHERS 222 Ii 1111 CR2 223 114 B.. N/C i 1 Common } SOLENOID VALVE S3 I I•I 24VAC VALVE PROVIDED BY OTHERS 2.24 APPROVED li lIl it APR 06 2023SOLENOID VALVE S4 N/C 1 1 Common 2 25 I I 4 24VAC VALVE PROVIDED BY OTHERS MASON COUNTY ENVIRONMENTAL HEALTH I� "I it 2.26 RET CR3 N/C 1 Common SOLENOID VALVE S5 24VAC VALVE 2 27 '14 • 1 1 PROVIDED BY OTHERS 2.28 11111111 EDWWD OE64121 Rim 1.0 0 0210912023 Irec.A7 Page 2oT3 3.1 3.2 Control Panel Connections 3.3 17] 1Y Y Y Y Y Y Vt C3 Y 3.4 _.I I.. 00C)0() 3.5 Pressure Switch 3.6 High Level i : { s Timed Alarm Redundant Off 3.7 3.8 Y NP l6 NB T 3.9 �- • •- • 3.10 0 ® 0 3.11 Discharge 3.12 3.13 3.14 3.15 3.16 3.17 3.18 3.19 3.20 3.21 3.22 3.23 3.24 3.25 APPROVED 3.26 APR 0 6 2023 3.27 MASON COUNTY ENVIRONMENTAL HEALTH RET 64dI �1 EDW.WD.OE1.121 / Rev.1.0®02/09/2023 Page 3of3 1 "fk auow Septic 1�e�stgfvs `' %iv), Y-a'- •'•.sue r OSCAR X02 Pretreatment 51.0 349 INSTALLATION& MAINTENANCE • PAULA nor ►OHNSONIC Mgr '. OSCAR At-Grade Drip Distribution Systems EXPIRES t 1. Installers must attend OSCAR X02 training and be certified by Dave Lowe at Low Ridge Technologies(www.lowridgetech.com)prior to installing this system. 2. Installer must review OSCAR X02 installer manual prior to system installation. 3. OSCAR XO2 supply kits are available through LowRidge Technologies approved suppliers only. 4. The Treatment Tank and Discharge Tank must both be 2-compartment, State approved and sized per the OSCAR X02 manual and the onsite wastewater treatment system designer. 5. OSCAR Sand media must meet or exceed ASTM C-33 standards. 6. Install drainfield level with contour of the ground. 7. Install drainfield during dry weather and soil conditions;any soil smearing must be eliminated by hand raking. 8. Tanks must have risers to the surface as required by Mason County to ensure easy access for future operation and maintenance. 9. Headworks must be in boxes accessible from the surface for future operation and maintenance. 10. Ensure any trees and shrubs are removed,grass is cut short and then scarify surface of ground in drainfield area to prep for drainfield. 11. Ensure 6"minimum cover sand media over the drip irrigation tubing. 12. Install audio/visual high-water level alarm. Redundant off switch not required. 13. Flow inducer tube or block are not required for the pump, it can sit on bottom of tank. 14. Install return line from headworks back into the tee outside the inlet of the treatment tank. 15. Encase all water lines within 10' of drainfield and under any driveway/parking areas. 16. Divert all storm water runoff and house downspouts away from on-site sewage system. 17. No curtain drains allowed within 10' of the up-slope edge or 30' of the down-slope edge of the drainfield and reserve area. 18. Inspect floats, clean filters,and test high water level alarm every 6-12 months as needed. 19. All materials and workmanship must meet County and State regulations. 20. Deviation from this design without prior approval from the Designer and Mason County Environmental Health Department will make this design null and void. 21. All manhole lids and access, sampling or inspection ports must have locking covers and be located at ground level. 22. All transport lines under driveways or parking areas must be encased to prevent crushing. 23. The tanks are to be protected from vehicle traffic or traffic-rated tanks may be used. 24. The drainfield is to be protected from all vehicle traffic or other damaging factors that could compact or disturb the soils. 25. The preferable cover planting for subsurface drip is turf or grass, or non-invasive groundcover plants. It is recommended to install an optional jute mat upon completion of the drainfield to prevent erosion and then seed with grass immediately. Other options include a thin layer of mineral soil low in organic content(<10%organics)and grass,a thin layer of crushed or washed rock for wind erosion protection,or a thin layer of bark or wood chips. 26. Do not cover the drainfield with organic mix(manufactured topsoil from compost)or filter fabric. 27. The homeowner should ensure no vehicle traffic,roto-tilling or digging in the area of the drip field to prevent damage to the drip tubing. Also, invasive plant species should not be allowed. 28. Home/property owner is responsible for all property lines, corners, surveys,encroachments,etc. 29. Owner Please Note: When you begin using your septic system, contact your septic installer to discuss setting up a schedule for your required Operation& Maintenance. APPROVED APR 0 6 2023 .7 _n �-1 MASON COUNTY ENVIRONMENTAL HEALTH `�`� RET