HomeMy WebLinkAboutSWG Pumpers Report / Maintenance - 2/3/2023 ENVIRONMENTAL 'ejL02a -f01Z` H EALT H AAA Septic LLC Septic Service Report '�1 -Satisfactory ❑ Unsatisfactory Property Owner 1 �[�'V\ Q Son Phone# I 786 .7C (46 Site Address ,1) ei\ o1 e C.:A- City Qcruci Tax Parcel# )- )- I 1 1Q -- 7 1 -- Q l 1 For Sale? ❑ Yes9Vo Septic Inspection Tank Size o 500❑750 o 1000,01200 o 1500 Effluent Level o Highei Normal o Low #of Compartments ❑OnegTwo o Three Tank Condition Satisfactory❑ Unsatisfactory Tank Material Concrete o Metal o Fiberglass o Poly Tank Pumped o Yes /No Inlet Baffle ,'Satisfactory o Needs Repair Outlet Baffle Satisfactory❑ Needs Repair Center Baffle Satisfactory❑ Needs Repair o N/A Baffle Repairs Fee Effluent Filter ip.Cleaned ❑ Not Cleaned❑ N/A Risers es❑ No Tank Depth Risers To Grade ( Yes o No Pump Chamber .Yes ❑ No P/C Gallons„ 4-%...,tn v — Operations&Maintenance Inspection i a; 1 2023 Is the pump functioning? (i Yes❑ No . Type/Model of pump i Q6t237 -615 W. Alder Street Tested gallons per minute flaw r Is alarm functioning as intended? Si Yes o No Were the lateral lines flushed? je Yes o No Average squirt height(in feet) ❑ &Jot Performed Ponding present? ❑Yes'No l Components accessible •r service? ter Yes❑ No All required service perform-• Q3-Yes ❑ No Surfacing effluent from any component (including mound) o Yes elNo 1 Components appear to be watertight 0 Yes o No Improper encroachment, cover,or settling problems o Yes Olo All riser lids securely fastened upon departure (Yes o No Electrical repairs needed(if yes,describe in comments) o Yes0No Root intrusion (if yes,describe in comments) ❑YesgNo Settling problems observed(if yes,describe in comments) o Yes 0 No House was vacant or used infrequently,assessment of o Yes p(No drainfield was not possible Septage Measurements /� l' f 15`Comp.Scum t? 2n°Comp. Scum 3rd Comp.Scum P/C Scum _ 1S`Comp.Sludge V ( 2n°Comp.Sludge �' 'Z 1`. 3rd Comp. Sludge P/C Sludge Total Gallons Pumped 4 Disposal Facility 0 Biorecycling ❑ Other Required Repair S L J Y (.xic PAtEr . ''vi`p • Suggested Service Maintena Serviceman Signature Date of Service 1.0 3 ' 23 2D3-CZDI I AAA Septic LLC _ PO Box 1460 �'EC L t�{ 360-427-6110 Shelton, WA 98584 ` 1 4 2023 PROPERTY INFORMATION 615W. Alder Street Location:10 E KEYHOLE CT O NMEN-TPki.- Shelton (�� Tax ID:221167790041 Man TO 5620 CRUZAT WAYKEITH ,1'�`•'IR �� Use: PENSACOLA,FL �EN- 32507 GENERAL SYSTEM TYPE:Conventional (Pressurized) ON ID:221167790041 County Area: Oakland Bay MRA Fold ON SITE WASTEWATER TREATMENT SYSTEM INSPECTION REPORT ` Fold Here Here Inspected:02/03/2023 - Inspection Type:ROUTINE - Correction Status:No corrections needed Company: Work Performed By Submitted 02/06/2023 by: AAA Septic LLC Alisha Wulf Alisha Wulf COMMENTS&GENERAL INSPECTION NOTES No Deficiencies Noted GENERAL SITE&SYSTEM CONDITIONS The General Site and System Conditions were: Fully Inspected Components accessible for service: YES All required service performed(if no-specify omitted inspection items in notes): YES Surfacing effluent from any component(including mound seepage): NO Components appear to be watertight-no visual leaks: YES Improper encroachment(structures/impervious surfaces) NO All riser lids securely fastened upon departure: YES Electrical repairs needed. If YES describe in comments: NO Root intrusion on any components. If YES describe in comments: NO Settling problems observed. If YES describe in comments: NO The house/structure was vacant or used infrequently,assessment of the drainfield was not possible. NO ONSITE SEWAGE SYSTEM INSPECTION DETAIL TANK:Septic Tank-2 Compartment This component was: Fully Inspected Effluent level within operational limits(if NO explain in comments): "ES All required baffles in place(N/A=No baffles required): YES Compartment 1 Scum accumulation(Inches.if other specify): 0 Compartment 1 Sludge accumulation(Inches,if other specify): 4 Compartment 2 Scum accumulation(Inches,if other specify): 0 Compartment 2 Sludge accumulation(Inches,if other specify): 2 Pumping recommended: NO TANK:Pump Tank This component was: Fully Inspected Compartment 1 Scum accumulation(Inches,if other specify) 0 Compartment 1 Sludge accumulation(Inches,if other specify) 0 Pumping recommended: NO Pump:Effluent Pump This component was: Fully Inspected Controls functioning: , YES Tested gallons per minute flow: •anel:Alarm-High Water This component was: Fully nspected Alarm mechanism functioning as intended: YES ReportlD:1151269 View inspection reports online at www.onlinemie.com Page 1 of 2 •rainfield(disposal):Pressure This component was: Fully Inspected Lateral lines flushed: YES Average squirt height(if performed)(feet,if other specify): Ponding present?If YES explain in comments: NO This report indicates census charactonstics o/rho ensile sewago system at the time o/visit.In no way is this report a guarantee or operation or future performance. ReportiD:1151269 View inspection reports online at www.onlinerme.com Page 2 of 2