HomeMy WebLinkAboutFIR2010-00025 Final AFA - FIR Permit / Conditions - 8/26/2010 = MASO-N COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262
Mason Lounty Bldg. 3 426 W. Cedar P.O. Box 186 Phone: (360)427-9670,ext.352
Shelton, WA 98584
FIRE PROTECTION PERMIT FIR2010-00025
APPLICANT: SCHOOL DISTRICT#311 RECEIVED: 8/18/2010
CONTRACTOR: LICENSE: EXP: ISSUED: 8/26/2010
SITE ADDRESS: 2987 W MATLOCK-BRADY RD ELMA EXPIRES: 2/26/2011
PARCEL NUMBER: 620223360000
LEGAL DESCRIPTION: SW SW EX &TR 2 SE SE SEC 21; TR 1 NE NE SEC 28; S 18/86
PROJECT DESCRIPTION: AUTOMATIC FIRE ALARM
GENERAL INFORMATION System Information
Type of Use: COMM
Fire District: 12 Sprinkler Heads: Audible Switches: Pull Stations:
Hood& Duct t: N Flow Switches: Visual Devices: Door Releases:
Dry Chemical?: N Pressure Switches:: Smoke Detectors: Duct Detectors:
Zones: Heat Detectors:
Wet Chemical?: N
Spdnkler?: N
Standpipe?: N SQUARE FOOTAGE FEES
Monitoring Company: First Floor: 2,300.00 Type Amount Due Amount Paid
Monitoring Phone No.:0 - Second Floor:
Auto Fire Alarm?:Y I Third Floor;: Auto. Fire Alarm Plan $109.50 $109.50
Auto. Fire Alarm Permit $168.50 $168.50
Total: $278.00 $278.00
FIR2010-00025 Please refer to the following pages for conditions of this permit. 1 of 4
CASE NOTES
FIR2010-00025
CONDITIONS FOR
FIR2010-00025
1.) Owner/A e isi;eWsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
X
2.) Valid Per it Must be on-site.
X
3.) Per seWon 901.2.1 of the 2006 International Fire code, Statement of Compliance.
Before requesting final approval of the installation, the installing contractor shall furnish a written statement to the fire code official that the subject fire
protection system has been installed in accordance with the approved plans and has been tested in accordance with the manufactures specifications and
the appropriate installation standard. Any deviations from the design standards shall be noted and copies of the approvals for such deviations shall be
attache o written statement.
X
4.) The em is4e uq_ired to be fully monitored by a UL listed monitoring company.
X �--
This permit becomes null and void if work orconstruction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is
commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is
by means of a progress inspection.The owner orthe agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above
described property and struc for review and inspection.
OWNER OR AGENT: DATE:
FIR2010-00025 Please refer to the following pages for conditions of this permit. 2 of 4
MASON COUNTY FIRE MARSHAL
Mason County Bldg.III 426 W Cedar St
PO BOX 186 Shelton,WA 98584
i (360)427-9670 Ext.273
Permit#
Mason County Fire Protection System Permit Application
Incomplete application will not be accented
Owner: Sc L c - %S 31 ( Phone#:
Mailing Address: City: State: Zip:
Site Address: N87 1, . M4i Joa 6LA,,t city: EIMA State: L^A Zip: 'FssC I
Parcel #: (07-O Z Z 3,3/o Legal Description: !! 0 Sc, -(-tZ-2 S&-S&S'&C ZI
r s - �g
Lien/Title Holder:
Address: C City: State: Zip:
Contractor: �;0►.1 LsLs1'L 1—+2S x C r� y _11V� Phone#: _U
Address: ?0- G011, rJ" q 7 City: 0,y ,f* State: L 4 A Zip: op5lf 0
Contractor Registration#: P(L)KJEFS 96S LC Expiration Date: 06 /201e-
0
Building Square Footage (existing &proposed): 1st / 2nd / 3rd /
Building Use: _ SC inCz:� Occupancy Classification: Construction Type:
Type of System: Type of Work:
Sprinkler: Wet Dry New System:
Standpipe: Wet Dry Modification: -X-
AFA: �—
Hood& Duct:
Dry Chem:
Wet Chem:
Fire Pump:
UL certified Monitoring company: Phone #:
Contractors Bid Price: $ , S�
Plan Submittal Requirements
Your plan submittal shall include the following;
• Plans shall be on standard 24"x 36"paper, drawn to scale with dimensions and north arrow.
• Site and Floor plan with cross sectional and exterior elevations.
• Location of occupancy and/or area separation walls, partitions, stairway enclosures, concealed spaces, etc.
• Cut sheets and/or references for all new devices.
• Location/description of all new and existing devices.
• Battery calculations.
• Wiring diagrams per floor or zone overlaid on an accurate floor plan.
• Electrical riser diagram showing all zones, circuits, devices, and end—of—line resistors.
• Hydraulic calculations.
• Copy of Contractors bid.
Fees
The permit fee will be assessed based on the submitted contractor bid for the project or a minimum of$168.50.
A plan review fee will be calculated at 65%of the permit fee(minimum$109.50)and is due upon submittal of permit application.
Contractor's Affidavit
I certify that I am a currently registered contractor in the State of Washington. I am aware of the ordinance requirements regulating
the work for which the pefnit is issued and certify that all work will be in compliance with this ordinance. No changes will be made
with ut first btaining ap val fftrcAn the Mason County Fire Marshal.
By: Date: 4—f y
-n to
55 CONCRETE MECHANICAL MANUFACTURED HOME n
IN) e
G Date By r
Footings !Setbacks Gas Piping Ribbons O
CIntenor Date By interior-Date By Date By r-
00 Exter+a Date By Exterior-Date_ B 0
Sat-
to
Point Load I Isolated Footings INSULATION Date By —I
Date By
Data SLAB INSULATION By FIRE DEPARTMENT Y n
Foundation Walls Floors Date By
Date By Data By DECKS CA)
FRAMING walls Date By
Date By Data By PROPANE TANKS
PLUMBING vault Date By
Date By OTHER
Groundwork Attic
Type-
Date By Date By Date By
D.w.v DRYWALL Type:
Int.Brace Wall Date By TI
Date By Date By _ _ m._ X
FINAL INSPECTION N
m Water Line Fire Separation 0
Date By Data By Date By C
� O
o Pass or Request Inspect. Co
Type of insp. Fail Date Date Done By Comments hj
0
0
O
CL
to
O
N
K
W
O
.A
Global Project Values:
SILENT Project Name: Mary Knight School Standby Hours: 24
KNIGHT Project ID: Alarm Mins:�
Prepared By: D Stephenson Derating Factor. 1.2
Expander5495 Power . Date: 8/16/201-0-----7 Voltage Drop Warning
Version 02.18.09 Threshold% : 10
Panel ID: 15495 Model: 5495 Power Expander Max NAC Current: 3.0 Amps
Location: I Out Building Volts: 24 VDC Max Panel Current: 6.0 Amps
Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ o
/o
Ckt# Circuit Name StandbyAlarm &Type 1000 Ft. One-WayOhms EOL Drap
5495 5495 Pwr Module 1 0.075 0.205
NAC#1 Exist Ckt Out Bldg 0.000 0.540 #16 Solid 4.02 100 0.80 19.97 2.13%
NAC#2 New Breezeway Horns 0.000 1.350 #16 Solid 4.02 180 1.45 18.45 9.58%
NAC#3 5495 Circuit 3 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00%
NAC#4 5495 Circuit 4 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00%
Aux 15495 Aux Power Out 0.000 0.000 1#12 Solid 1 1.59 0.00 1 20.40 0.00%
Total Standby Current(Amps) 0.075 2.095 Total Alarm Current(Amps)
Standby Time In Hours 24 0 083 Alarm Time In Minutes/60 (5 Mins)
Total Standby AH Required 1.800 0.175 Total Alarm AH Required
Total Combined AH Required 1.97 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of the
Multiply By The Derating Factor 1.20 minimal difference between solid and stranded wire no differential was made.
Minimum Battery AmpHours Required 2.37
Configure Circuits Print Page
1 KNICHT Circuit Configuration
t
Project Information
Project Name: Mary Knight School Project ID: 0
Prepared By: D Stephenson Date: 8/16/2010
Ckt.Number: NAC#1 Panel ID: 5495
Ckt.Name: Exist Ckt Out Bldg Max Circuit Current: 3 Amps
Qty Device Current Draw Each Current Draw Total
Standby Alarm Standby Alarm
2 Centex GCC24 Horn/Strobe 75cd) 0.000 0.270 0.000 0.540
Unused 0.000 0.000 0.000 0.000
Unused 0.000 0.000 0.000 0.000
Unused 0.000 0.000 0.000 0.000
0.000 0.000
Totals 0 000 0 540
Ckt.Number. NAC#2 Panel ID: 5495
Ckt.Name: New Breezeway Horns Max Circuit Current: 3 Amps
Qty Device Current Draw Each Current Draw Total
Standby Alarm Standby Alarm
5 Gentex GCC24 Horn/Strobe 75cd) 0.000 0.270 0.000 1 1.350
Unused 0.000 0.000 0.000 0.000
Unused 0.000 0.000 0.000 0.000
Unused 0.000 0.000 0.000 0.000
0.000 0.000
Totals 0 000 1.350
Ckt.Number: NAC#3 Panel ID: 5495
Ckt.Name: 5495 Circuit 3 Max Circuit Current: 3 Amps
Qty Device Current Draw Each Current Draw Total
Standby Alarm Standby Alarm
Unused 0.000 1 0.000 0.000 0 000
Unused 0.000 0.000 0.000 0.000
Unused 0.000 0.000 0.000 0 000
Unused 0.000 0.000 0.000 0.000
0.000 0.000
Totals 0.000 1 0.000
Ckt.Number. NAC#4 Panel ID: 5495
Ckt.Name. 5495 Circuit 4 Max Circuit Current 3 Amps
Qty Device Current Draw Each Current Draw Total
Standby Alarm Standby Alarm
Unused 0.000 0.000 0.000 0.000
Unused 0.000 0 000 Q000 0.000
Unused 0.000 0.000 0.000 0.000
Unused 0.000 0-000 0.000 0.000
0.000 0.000
Totals 0.000 0.000
Ckt.Number Aux Panel ID: 5495
Ckt.Name: 5495 Aux Power Out Max Circuit Current: 3 Amps
Qty Device Current Draw Each Current Draw Total
Standby Alarm Standby Alarm
Unused 0 000 1 0.000 0.000 0.000
Unused 0.000 0.000 0.000 0.000
Unused 0.000 0.000 0 000 0,000
Unused 0.000 0.000 0.000 0.000
0.000 0.000
Totals 0.000 0 000
df-50673:Rev•F-850
302 Series FIMIITUALarms
Rate-Anticipation Heat Detectors
by Honeywell
Conventional Initiating Devices
General
The Thermotech 302 Series rate-anticipation heat detectors
operate within a controlled range of two to three degrees of
their set points, regardless of the speed or rate of temperature
rise. These detectors are available in either 135°F(57.2°C)or Model302 Model
194°F(90°C)ratings.
The 302 Series are normally-open devices designed espe-
cially for fire detection and alarm systems.
Features
• Immediate response. The 302 Series activate whenever 14
ambient air temperature reaches a detector's setting, elimi-
nating the thermal time lag inherent in conventional heat
detectors. Model 302-EPMModel
• Eliminates false alarms. The 302 Series do not respond
to momentary temperature fluctuations below the selected
temperature.
• Universal application. The 302 Series can be used in all
areas for any type of occupancy.
• Self-restoring.
• Hermetically sealed. Shock resistant, corrosion resistant,
and tamper-proof. 1271wro1.og
Principles Of Operation Agency Listings and Approvals
The 302 Series rate-anticipation heat detectors respond and These listings and approvals apply to the modules specified in
activate the fire alarm immediately whenever the ambient tem- this document.In some cases,certain modules or applications
perature reaches the preset temperature setting. Under rapid may not be listed by certain approval agencies, or listing may
heat rise conditions, the rate-anticipation feature enables the be in process.Consult factory for latest listing status.
detector to respond one to three degrees ahead of the setting.
At the same time, however, it does not respond to momentary • UL Listed: S539 (302-AW-135/-194; 302-ET-135/-194;
temperature fluctuations below the selected protection level, 302-135-194)
thus eliminating false alarms. When temperature drops back • FM Approved: (302-AW-135/-194; 302-ET-135/-194;
down below the protection level, the detector automatically 302-135/-194)
resets itself. • CSFM:7270-0021:001
Dimensions (Model 302)
Total overall length: 4-1/8'(10.48 cm).
Base diameter: 2'(5.08 cm).
Electrical Ratings t271°a1Of
Vokaae Current
6-125 VDC 5 amps FINE CON AICTEPOINTS
6-25 VDC lamp EXPANSION STRUTS
HIGH EXPANSN
125 VDC 0.5 amp ..SIN.SHELL EN 0 0.
ANODIZED ALUMINUM
Application Information NEATROLS EEVE
CEATROLSLEEVE
302 Series detector have a smooth ceiling UL rating of 50' x SETTING SCREW
ON
50'(15.24 x 15.24 meters)and are the only type of heat detec- HER HERMETIC SEAL
tors having such a rating on both fixed temperature and rate
anticipation.
Cut-Away View
df-50673:Rev•02/03/09—Page 1 of 2
4
Thermotech Model 302 Series Rate-Anticipation Heat Detectors
Model Number Description Refer To
302-135 135°F Interior Vertical Mounting
Note 1 below
302-194 194°F Interior Vertical Mounting
302-AW-135 135°F All-Weather Vertical Mounting
Note 2 below
302-AW-194 194•F All-Weather Vertical Mounting
302-ET-135 135•F All-Weather Vertical Mounting
Note 3 below
302-ET-194 194°F All-Weather Vertical Mounting
302-EPM-135 135°F Explosion Proof Mounting
Note 4 below
302-EPM-194 194•F Explosion Proof Mounting
AP-P Decorative white plastic adaptor plate for mounting 302 and 302-AW to 4"outlet box.
.,
NOTE 1:For interior mounting in any atmosphere that is compatible with terminal-screw-type connections. UL rating 50'x 50'(15.24 x
15.24 meters).
NOTE 2.Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox when the all-weather leads are
properly spliced to"THW"or equivalent type wire.
NOTE 3:Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox. Has plastic hexagonal wrench
grip bushing with 112"(1.27 cm)conduit threads for attachment to threaded hub cover,or any outlet box.
NOTE 4:Explosion-proof for installation in hazardous locations. Has hexagonal wrench-grip bushing with 112"(1.27 cm)conduit threads
for attachment to threaded hub cover of Series JL fixture fitting as manufactured by Killark Electric Co.,or equal.
C2009 by Honeywell International Inc.All rights reserved.Unauthorized use
of this document is strictly prohibited.
This document is not intended to be used for installation purposes.
ISO 9001
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
9ICINEBIN9 MAMIFACi1AINC All specifications are subject to change without notice. s
QUALITY SYSTEMS Made in the U.S.A.
For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105.
www.firelite.com
Page 2 of 2—df-50673:Rev•02/03/09
GENTEX
CORPORATION
imarter I
Outdoor Commander Series WGEC24/
Evacuation Signals WGES24
Applications
The Outdoor Commander Series offers dependable visible and/or audible S E R I E S
alarms for all outdoor needs.
Included with the WGE Series is the GqE or GOELP outdoor enclosure. The
enclosure is made of high quality Lexan material, providing protection from .
weather related conditions and allowing the necessary full candela
output. This highly constructed enclosure meets various installation m
requirements including deterring moisture from entering the enclosures.
r
The Outdoor Series is equipped with the 4" mounting plate which incorporates
the Super-Slide'feature that allowes the installer to easily test for
supervision. The product also features a locking mechanism which
secures the product to the bracket without any screws showing.
The WGE Series also features the Checkmate-- Instant Voltage Verification �
feature which allows the installer to check the voltage without removing the
signal.
F
r � � d
The WGE Series strobe has a minimal operation current and has a minimum
flash rate of 1 Hz and can vary up to 2Hz regardless of input voltage.
The WGE Series appliances are UL 464 and UL 1638 listed for use with fire +
protective systems and are warranted for three years from date of purchase.
Standard Features GOELP GOE
• Nominal Voltage 24VDC
• Unit is Shipped with UL1638 listed WGES24-75 Candela Strobe WGES24 and WGEC24 Shipped
or WGEC24-75 Candela Horn/Strobe with the GOE or GOELP
• Unit Dimensions: GOE 5.75" High x 4.75" Wide x 4.18" Deep Outdoor Enclosure
GOELP 5.75" High x 4.75" Wide x 3.25" Deep
• To Obtain Outdoor Horn, Must Order GEH24 and GOE/GOELP Product Listings
Separately
• Super-Slide" - Ease of Supervision Testing
• Checkmate"- Instant Voltage Verification
• Lower Installation and Operating Costs
• Switch Selection for High dBA IMbiU"'""°'°'"R5LM FUTWO WC,ura a uoemriarens ueowranEs,mac.
• Switch for Mechanical and 2400Hz Tone • BFP(City of Chicago)
• Switch for Continuous Tone • BS+ANEA#285-91E-XVI
• Tamperproof Re-entrant Grill • CSFM 7135-0569:122(WGES)
• Wide Voltage Range 16-33 VDC or FWR 7300-0569:124(ENCLOSURE)
• Separate Horn and Strobe Functions • UL 464 &UL 1638 Listed
• Synchronize Strobe and/or Horn by Using Gentex
Synchronization Control Module Product Compliance
• Listed for UL1638 when used with the GOE or GOELP enclosure • Americans with Disabilities Act(ADA 4.28.3)
• GOE/GOELP Made of Clear Lexa® Provides Maximum Visibility and NFPA 72
Reliability for effective Visible Signaling -Allowing Full 75cd Output
• Input Terminals 12 to 18 AWG
• Faceplate Available in Red or Off-White " " A94EM ID
THE USA
GEH24 - 24 Volt Low Profile Evacuation Horn
Model um er art um er orninal ever erant dBA @ In Anechoic Room
Voltage 1Oft. Per UL 4641 dBA @1Oft.
90 07-002 2 0-82 100
NOTE: Must order the GOE or GOELP separately when using the GEH24 in an outdoor application.
WGES24 - 24 Volt Low Profile Evacuation Outdoor Strobe Model designations:
"W" = Wall Mount
Model um er art Number Nominal Candela "R" = Red Faceplate
Voltage (UL 1638) "W" = Off-White Faceplate
WGES24-75W7- 90 2 02 24 VDC 75
2 _ "P" = Plain (no lettering)
Plain units are non-returnable.
WGES24-75PWVT—. 0 8-00 LP"=Low Profile (GOELP Enclosure)
WGES24-75W 904 24 VDC 5
24-75WWLP 904-1263-002 24 VDC 75 WGES24 and WGEC24
6 _ shipped with the GOE or
WGES24-75PWWCTI-- 9 2 2 24 VDC 75 GOELP Outdoor Enclosure
WGEC24 - 24 Volt Low Profile Evacuation Outdoor Horn/Strobe
Model um er Part Number Nominal Candela Reverberant dBA @ In Anechoic Room
Voltage (UL 1638) 1 Oft Per UL 464 dBA @ 1 Oft.
0
VT7=2T_ 5 9 2 2 7
0 6 5 00
75 2 24 VUU j 7S 70-82 100
WGEC24-75PVVRrF5--- -0
Notes:
•The WGE Series is listed for outdoor use. Indoor Operating Temperature: 32°to 120°F (0'to 49°C).
Outdoor Operating Temperature: -31°to 150°F (-35' to 66°C).
• For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered
(FWR [Full Wave Rectified]) power, see installation manual.
• Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products
WGE Series Product Strobe Current Ratings
Candela c
m
UL Max 180m
SeriesWGE
ro uct Horn Current Ratings
Horn Mode MinimumMinimum Regulated 2 ax.
per UL464(HIGH) per UL464 (LOW) Operating @ High Setting (mA)
emp 3 240OHz 8
emp 3 Mechanical
emp Ime
Continuous 240OHz
Continuous Mechanical
Continuous me
V7150-0—p
Operating the horn in this mode at this voltage will result in not meeting the minimum UL reverberant sound level required for public mode fire protection service. These set-
tings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is
always private mode).
Notes:The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in
the temporal 3 mode its sound pressure is the same as the continuous mode.
To obtain the horn/strobe current draw,add the strobe current draw and the horn current draw.
I RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units)(8-17VDC for
12VDC units). For strobes the UL max current is usually at the minimum listed voltage(16VDC for 24VDC units)(8VDC for 12VDC units). For audibles the max current is usually at the
maximum listed voltage. For unfiltered FWR ratings,see installation manual.
Mounting Super-Slide"
azm
j�
Y cw.
GASKET
Super-Slide's Mounting Plate: Super-Slide" Mounting Plate:
Mounts to GOE outdoor box. Mounts to GOELP outdoor box.
Checkmate- - Instant Voltage Verification Switch Locations
SWITCH POSITION
i Nticharica4Tanp. ON ON ON
p V. Ma hanla4CvR OF, ON ON
\/ HiTamp. ON OFF ON
HrCaM. OFF OFF ON
\ S+ Chi—T" ON ON OFF
\ chii—Cont OFF ON OFF
S+ `Ahoop ON OFF OFF
1! vMoop OFF OFF OFF
I O
Switch positions 1 and 2
yll,, i
In the Off position to select
powe horn and strobe
power inputs.
L " ,
The access holes are provided in the back of the terminal ON
block to allow the voltage to be measured directly without
removing the device.Typically this would be done at the "
end of the line to confirm design criteria. Most measure-
ments will be taken using the S+and S-locations
although access is provided to other locations. NOTE: 1 2 3 4 5 6
Care should be taken to not short the test probes.
Conventional WGE Series Wiring Diagrams
UL Listed ULListed
Control Control
Signal Signal Panel Signal Signal
Panel s+ s+ S. H. H. s+ S+ S_ H+ I+
S+ S+ S- H+ H- S+ S+ S- H+ H-
Supervised 0 0 B 0 Supervised
Signal Circuit
Signal Circuit +
END OF LINE
\ + RESISTOR
END OF LINE
RESISTOR
\ +
END OF LINE
RESISTOR
- - - - - - - ---- - - - -----
Wiring Diagram WGE Series with Gentex Synchronization Module y
F A.C.P.
RE4sTOR FOR i I TO NET SIGNAL TO NOTIFICATION ALARM CIRCUIT
CU59 A
TO NEXT SIGNAL TO NOTIFICATION ALARM CIRCUIT
REMOVE JUMPER
FORINDEPENOENT
SYNCHRONIZED STROBE __
AUDIBLE SIGNAL END OF LWE AND MORN OPERATION HR '
CIRCUIT REacus�.a eon SYNCONIZATION
vnR„p ONLr LEAVE JUMPERIN PLACE
Fz
TO ELIMINATE NEED FOR MODULE LEAVE JUMPER IN PLACE ON
HORN INPUT ON AVSM SLAVE UNITS UNLESS SEPARATE
4WD OPERATE SIGNAL " I` CONTROL OVER HORN CKT
alas. IN UNISON MODE B m(0 IS REQUIRED.
SYNCHRONIZATION
MODULE Signal signal
S- S- S- H. H- S+ S. S- H. H-
B B B B
VISIBLE SIGNAL � I I I
END 6 LINE
RESISTOR FOR
CIRCUIT CUSS B
Y,1aNO ONLY
I 1
I I 1 I
, I
i
ENOaF LINE _______________________a _t_t_______________.___________________________________-____________-____._-__—_______._____--________� i
RESISTOR FOR I
CLASS A
I I
WWWO ONLY. ,
Note: See Technical Bulletin 015 for proper synchronization module for application.
Architect & Engineering Specifications:
The audible and/or visible signal shall be Gentex WISE Series or approved equal and shall be listed by Underwriters Laboratories Inc.per UL 1638
and/or UL 464.The notification appliance shall also be listed with the California State Fire Marshal(CSFM)and the Bureau of Standards and Appeals
(NYC).
The notification appliance(combination audible/visible)shall produce a peak sound output of 100dBA or greater at as measured in an anechoic
chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a
single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability
to be synchronized.
The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 2 Hz regardless of power input voltage.
The appliance shall have an operating current of 112mA or less for the 75Cd strobe circuit. The appliance shall also be capable of meeting the candela
requirements of the ADA(75cd),
The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with
terminals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter
plate.The unit shall have an input voltage range of 16-33 volts with either direct current of full wave rectified power for 24 volt models.
The appliance shall be capable of testing supervision without disconnecting wires.Also the appliance shall be capable of mounting to a surface back
box. The unit shall also be able to verify voltage at the unit without removing unit.
The appliance has extended temperature range of-31'to 150OF(-35D to 66D C). The appliance shall satisfy virtually all outdoor and severe
environment applications. The GOE Enclosure is includes a gasket that must be inserted between the box and mounting bracket. There are drain holes
in the back box to allow for drainage,the seal on the GOE Enclosure is not water tight. The GOELP Enclosure includes a weather seal for mounting to `
wall and intended for use with universal electrical box. To allow for drainage,bottom edge of enclosure is not water tight.
1 unit per carton
3 pounds per carton
Important Notice.
G E N T E X These s materials have been prepared by Gentex me as leg ('Gentexa for informational purposes only,are 551-0047-02
necessarily summary,and are not purported to sane as legal advice and should not be used as such.
Gentex makes no representations and warranties,express or implied,that these materials are complete
G O R P'0,F2 A T 10 N and accI ate,up-to-date,or in compliance with all relevant local,state and federal laws,regulations and
rules.The materials do not address all legal considerations as there is inevitable uncertainty regarding
interpretation of laws,regulations and rules and the application of such laws,regulations and rules to partic-
Fire Protection Products:wvvw. entex.com ular fact patterns. Each persons activities can differently affect the obligations that exist under applicable
g laws,regulations or rules.Therefore,these materials should be used only for informational purposes and
10985 Chicago Drive Box 310•Zeeland, Michigan 49464 should not be used as a substitute for seeking professional legal advice.Gentex will not be responsible for
616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax any action or failure to act in reliance upon the information contained in this material.
Gentex corporation reserves the right to make changes to the product data sheets at their discretion. 0 Printed on Regc!ed Paper