Loading...
HomeMy WebLinkAboutBLD2021-01661 SFR - BLD Inspections - 1/13/2023 615 W.Alder St.Bldg 8,SHELTON,WA 98684 MASON COUNTY SHELTON:360-427-9670,EXT 352 COMMUNITY SERVICES BELFAIR:360-275-4467,EXT 352 Building,Planning,Environmental Health,Community Health ELMA:360-482-5269,EXT 352 www.co.mason.wa.us INSPECTION CARD AND CERTIFICATE OF OCCUPANCY" To schedule an inspection call or visit http://www.co.mason.wa.us/community-services/bid-inspection.php Permit Number BLD2021-01661 Date Issued 02/25/2022 Issued By Project New SFR Site Address 51 NE GARRICK LN Applicant DEREK&ALIAHNA WATTS Contractor Contractor Phone Primary Code UPC IBC,IRC,IFC,IEC,IMC,& Type Permit Type .NEW SINGLE FAMILY RESIDENCE Occupancy -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS. -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED. -THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION,FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY. -ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION. -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION. "THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED" PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET Public Works Access/Driveway Other Health Septic Well Deptartment Planning Site Inspection Department Fire Marshall Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final Building Building Official: Community Services Designee Department Concrete Setbacks Z,- LV_z-:L&17d Slab Footing Perimeter 1, Point load Footing Footing Interior Footing Decks/Porches Foundation Stem Walls DbC Other Rough-In Groundwork Plumbing Framing Groundwork Mechanical Plumbing Groundwork Gas Pipe Mechanical Gas Piping Shear Wall Nailing Underfloor Other Insulation Slab Ceiling Floor Vaulted Ceiling Walls Vapor Barrier Other Wallboard Interior Wall Brace Panels Fire Walls Nailing Other Final Building Manufactured Setbacks Setup Home Concrete Foot/Runners Final Other . � BUILDING MASON COUNTY d 615`�° F COMMUNITY SERVICES Building,Planning,Environmental He ilth,Community a eolth These requirements apply to all IRC building types, including detached one-and two-family dwellings and multiple S single-family dwellings(townhouses). Contact Information Project Information Owners Name: ite Address: J Derek&Aliahna Watts 51 NE Garrick Ln. Mailing Address: Belfair,WA 98528 PO Box 2666 Belfair WA 98528 Parcel Number: 12321-24-90083 Square Feet(total): 2720 Ventilations Compliance: OWhole House Ventilation system 0 Whole House Ventilation using exhaust fans&window or wall Integrated with a Forced Air fresh air vents(M1507.3.4) System(M1507.3.5) Other, describe: Instructions:This single-family project will use the requirements of the Prescriptive Path below and incorporate the minimum values listed. Based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Provide all information from the following tables as building permit drawings:Table R402.1- Insulation and Fenestration Requirements by Component,Table R406.2- Fuel Normalization Credits and 406.3- Energy Credits. All Climate Zones(Table 11402.1.1) R-Value' U-Factora Fenestration U-Factorb n/a 0.30 Skylight U-Factor b n/a 0.50 Glazed Fenestration SHGC bje n/a n/a Ceiling a 49 i 0.026 Wood Frame Wall g,h 21 int 0.056 Floor 30 0.029 Below Grade Wall`,h 10/15/21 int+TB 0.042 Slab d,f R-Value& Depth 10, 2 ft n/a R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity that is less a than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified irf the table. b The fenestration U-factor column excludes skylights. "10/15/21+5TB" means R-10 continuous insulation on the exterior of the wall,or R-15 continuous insulation on the interior of the wall,or R-21 cavity insulation plus a thermal break between the slab and the basement wall at c the interior of the basement wall. "10/15/21+5TB"shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB" means R-5 thermal break between floor slab and basement wall. d I R-10 continuous insulation is required under heated slab on grade floors.See Section R402.2.9.1. Prescriptive Path—Single Family 2018 Washington State Energy Code-R { r For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38 if the full insulation depth e extends over the top plate of the exterior wall. R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used,it shall meet the requirements for thermal barriers protecting foam plastics. For log structures developed in compliance with Standard [CC 400, log walls shall meet the requirements for g climate zone 5 of ICC 400. Int. (intermediate framing)denotes framing and insulation as described in Section A103.2.2 including standard h framing 16 inches on center,78%of the wall cavity insulated and headers insulated with a minimum of R-10 insulation. Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel normalization credits)and Table 406.3(energy credits) to achieve the following minimum number of credits.To claim this credit,the building permit drawings shall specify the option selected and the maximum tested building air leakage and show the qualifying ventilation system and its control sequence of operation. 1. Small Dwelling Unit: 3 credits Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. 2. Medium Dwelling Unit:6 credits All dwelling units that are not included in#1 or#3 3. Large Dwelling Unit: 7 credits Dwelling units exceeding 5,000 sf of conditioned floor area 4. Additions less than 500 square feet: 1.5 credits All other additions shall meet 1-3 above Before selecting your credits on this Summary table, review the details.in Table 406.3(Single Family),on page 4. Summary of Table R406.2 Heating Credits-select ONE Options Fuel Normalization Descriptions heating option User Notes 1 Combustion heating minimum NAECAb 0.0 ❑ 2 Heat pump` 1.0 ❑✓ 3 Electric resistance heat only-furnace or zonal -1.0 ❑ 4 DHP with zonal electric resistance per option 3.4 0.5 ❑ 5 All other heating systems -1.0 ❑ Energy Credits-select ONE Options Energy Credit Option Descriptions energy option from each p cate or 1.1 Efficient Building Envelope 0.5 ❑ 1.2 Efficient Building Envelope 1.0 ❑ 1.3 Efficient Building Envelope 0.5 1.4 Efficient Building Envelope 1.0 ❑ 1.5 Efficient Building Envelope 2.0 ❑ 1.6 Efficient Building Envelope 3.0 ❑ 1.7 Efficient Building Envelope 0.5 ❑ 2.1 Air Leakage Control and Efficient Ventilation 0.5 ❑✓ 2.2 Air Leakage Control and Efficient Ventilation 1.0 ❑ 2.3 Air Leakage Control and Efficient Ventilation 1.5 ❑ 2.4 Air Leakage Control and Efficient Ventilation 2.0 ❑ 3.1a High Efficiency HVAC 1.0 ❑ 3.2 High Efficiency HVAC 1.0 ❑✓ 3.3a High Efficiency HVAC 1.5 ❑ 3.4 High Efficiency HVAC 1.5 ❑ 3.5 High Efficiencv HVAC 1.5 ❑ 3.6a High Efficiency HVAC 2.0 ❑ Prescriptive Path-Single Family 2018 Washington State Energy Code-R 4.1 High Efficiency HVAC Distribution System 0.5 ❑✓ 4.2 High Efficiency HVAC Distribution System 1 1.0 ❑ 5.1d Efficient Water Heating 0.5 ❑ 5.2 Efficient Water Heating 0.5 ❑ 5.3 Efficient Water Heating 1.0 ❑ 5.4 Efficient Water Heating 1.5 ❑ 5.5 Efficient Water Heating 2.0 ❑✓ 5.6 Efficient Water Heating 2.5 ❑ 6.1e Renewable Electric Energy(3 credits max) 1.0 ❑ 7.1 Appliance Package 0.5 X❑ Total 6 Credits a. An alternative heating source sized at a maximum of 0.5 W/sf(equivalent)of heated floor area or 500 W, whichever is bigger, may be installed in the dwelling unit. b. Equipment listed in Table C403.3.2(4)orC403.3.2(5) c. Equipment listed in Table C403.3.2(1)orC403.3.2(2) d. You cannot select more than one option from any category EXCEPT in category 5.Option 5.1 may be combined with options 5.2 through 5.6.See Table 406.3. e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max. See the complete Table R406.2 for all requirements and option descriptions. Please print only:pages 1 through 3 of this workshdet for submission to your building official:` Prescriptive Path—Single Family 2018 Washington State Energy Code-R I� TE rr t r t(CAL [y KANU r RED HOME its- Gas Kping Irpterioc DEW BY IrYrerior-Dafe BY Dint- By Ext--rbr-Dad:. By- � - l olc2f a lsc�: erl ?CRi31 INSULATION nit= as t SIAM INSULATION BY Dat_ By Dam By FIRE DEPARTMENT r-wrididlon Walls Dzde• By DECK5 FRAMING W41It Date BY Date By Data By PROPANETANKS Data- -- SY OTHER ei Atbr Y1� L}at�t gar DAM - �} . Date By D-Wv [DRYWALL Type: Int Brace wall Date BY �nate �Y � By N - FINAL INSPECTION CD Fire seper�aton Date By €da By De:e BY m Pass or Request Crtspe-at. 5 TYPO Of FnSP Fat[ Data Data Done ByCD Comments Z 5 -n-Z1-CD CD i 0 f # 57- y SS — 22 -� a I CD Ot; � -1 t o co ° tS 1-13-.231 DE A MASON COUNTY 360-427-9670 Shelton ext.352 COMMUNITY SERVICES 36 60-482-52 Belfair ext.352 ' 360-482-5269 Elma ext.352 Building,Planning,Environmental Health,Community Health 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: 15 L t7 20 Z-1 — 61 U Le/ ADDRESS/LOCATION: 5'1 NE- b, go/o4 I� i FIN PINGS: 11 Veg ty -Ae*w -W_ z 2 I� ?-too v.A�- i 02.E Sp fib mv_c) Jeff /✓O(Jl C G �'N �'f g� Vgc4 40dw l Q tit �C r e A -s ve- a lib ih vc✓N et C%✓e- Q .f lril- Co►-vrr� Zvi spa/lam -(fr!�,_ / /tom c;� GZ�iGY�s t a HW !!/lS e—e a 71k 6 f&L la4_ Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any further work. � � Make corrections, items will be checked on the next inspection. ❑ OK to Date: `T'l�- Z Z ❑ Please contact our office regarding possible Department: structural damage incurred by recent Inspector: J� "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS. TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY SERVICES 360-482-5269 Elma ext.352 Building,Planning,Environmental Health,Community Health 0615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER:_,��A�-01-- �\�tl VQ \ ADDRESS/LOCATION: �\ IV ai AK Y'\C\L DINGS: YV Y Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. ake corrections,items will be checked on the next inspection. ❑ OK too Date: `A�L Z2- ❑ Please contact our office regarding possible Department: LD structural damage incurred by recent Inspector: AU p{of Z-, . "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS. TAG MCC14.12 Mason County Mason County - Division of Community Development 615 W.Alder St. Bldg.8 Hi Shelton,WA 98584 360-427-9670 ext 352 www.co.mason.wa.us B DD2021-01661 NEW SINGLE FAMILY RESIDENCE PROJECT DESCRIPTION: NEW SFR ISSUED: 02/25/2022 SITE ADDRESS: 51 NE GARRICK LN BELFAIR EXPIRES: 08/24/2022 PARCEL: 123212490083 APPLICANT: DEREK&ALIAHNA WATTS OWNER: DEREK&ALIAHNA WATTS PO BOX 2666 PO BOX 2666 BELFAIR,WA98528 BELFAIR,WA98528 360.801.5404 VALUATIONS: FEES: Paid Due R-3 VB Residential, one- 2720.00 $403,457.60 Planning Review Fee $240.00 $0.00 and two-family State Fee-Residential $6.50 $0.00 Covered Deck/Carport 400.00 $8,800.00 Plan Check Fee $2,188.00 $0.00 U VB Utility, miscellaneous 952.00 $57,005.76 Building Plan Review/Change of $125.00 $0.00 Use-Onsite Sewage Mechanical Fees $172.00 $0.00 Plumbing Base Fee $25.00 $0.00 Mechanical Base Fee $30.00 $0.00 Plumbing Fees $167.00 $0.00 Building Permit Fee $3,366.16 $0.00 Technology Surcharge $118.96 $0.00 Total: $469,263.36 Totals : $6,438.62 $0.00 FIXTURES Qty Mechanical Fixtures Qty Plumbing Fixtures 1.0000 Dryer Vent(s) 1.0000 Number of Clothes Washers 1.0000 Kitchen Exhaust Hood(s) 1.0000 Number of Dishwashers 1.0000 Furnace(s) 1.0000 Number of Kitchen Sinks 1.0000 Heat Pump(s) 1.0000 Number of Water Heaters and or Vent 1.0000 Wood/Gas/Pellet Stove(s) 2.0000 Number of Hose Bibs Printed by:Genie Mcfarland on:02/25/2022 08:22 AM Page t of 8 Mason County Mason County - Division of Community Development 615 W.Alder St. Bldg.8 Shelton,WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2021-01661 .City Mechanical Fixtures Qty Plumbing Fixtures 3.0000 Spot Vent Fan(s) 2.0000 Number of Bath Tubs 3.0000 Number of Showers 3.0000 Number of Toilets 5.0000 Bathroom Sink REQUIRED INSPECTIONS Setback Inspection Framing Inspection -----------------------------------------------------. Footing Inspection Rough-Plumbing Inspection -----------------------------------------------------. _. _ _ — — — _ _ _ Foundation Wall-Pre-Pour Inspection Mechanical Inspection ----------------------- --------- ------------------ Underfloor Inspection Insulation Inspection -----------------------------------------------------. Shearwall Inspection BLD-Final Inspection CONDITIONS * When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at(360)427-9670, ext.450 or 100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. --------------- ------. ---------------------------------- ---------------------------------- -------------. --- " Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor &Industries (L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415- 4000. The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. Printed by:Genie Mcfarland on:02/25/2022 08:22 AM Page 2 of 8 Mason County Mason County - Division of Community Development 615 W.Alder St. Bldg.8 Shelton,WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCEBLD2021-01661 Adopted IECC/Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window(Max U- Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less,Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49,Vault Insulation R-38, and Slab Insulation R-10. Fuel Normalization Credits:Table 406.2 2 Heat pump Table 406.3—Energy Credits(Single Family) 1.3 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U =0.28, Floor R-38, Slab on grade R-10 perimeter and under entire slab below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by 5% 2.1 Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per hour. maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested air leakage to 0.3 cfm/sf maximum at 50 Pascals and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a high efficiency fan(s)(maximum 0.35 watts/cfm), not interlocked with the furnace fan (if present).Ventilation systems using a furnace including an ECM motor are allowed if they are controlled to operate at low speed in ventilation only mode. 3.2 Air-source centrally ducted heat pump with minimum HSPF of 9.5. 3 4.1 All supply and return ducts located in an unconditioned attic shall be deeply buried in ceiling insulation in accordance with Section R403.3.7. For mechanical equipment located outside the conditioned space, a maximum of 10 linear feet of return duct and 5 linear feet of supply duct connections to the equipment may be outside the deeply buried insulation. All metallic ducts located outside the conditioned space must have both transverse and longitudinal joints sealed with mastic. If flex ducts are used, they cannot contain splices. Duct leakage shall be limited to 3 cfm per 100 square feet of conditioned floor area.Air handler(s)shall be located within the conditioned space. 5.1 A drain water heat recovery unit(s)shall be installed,which captures wastewater heat from all and only the showers and has a minimum efficiency of 40% if installed for equal flow or a minimum efficiency of 54% if installed for unequal flow. Such units shall be rated in accordance with CSA B55.1 or IAPMO IGC 346-2017 and be so labeled. To qualify to claim this credit, the building permit drawings shall include a plumbing diagram that specifies the drain water heat recovery units and the plumbing layout needed to install it. Labels or other documentation shall be provided that demonstrates that the unit complies with the standard. 5.4 Water heating system shall include one of the following: Electric heat pump water heater meeting the standards for Tier I of NEEA's advanced water heating specification or for R-2 Occupancy,electric heat pump water heater(s), meeting the standards for Tier I of NEEA's advanced water heating specification, shall supply domestic hot water to all units. If one water heater is serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with R-8 minimum pipe insulation. 5 7.1 All of the following appliances shall be new and installed in the dwelling unit and shall meet the following standards: Dishwasher—Energy Star rated Refrigerator(if provided)—Energy Star rated washing machine—Energy Star rated Dryer—Energy Star rated,ventless dryer with minimum CEF rating of 5.2, all appliances shall be installed and connected to utilities. Dryer ducts and exterior dryer vent caps are not permitted to be installed in the dwelling unit. Printed by:Genie Mcfarland on:02/25/2022 08:22 AM Page 3 of 8 1 Mason County Mason County - Division of Community Development 615 W.Alder St. Bldg.8 tea, Shelton,WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCEBLD2O21-01661 * A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design,sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. "NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan"constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. ------- -------- --------------------- --------_. -- - -------- Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations(including addition or alteration of fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or -created. Printed by:Genie Mcfarland on:02/25/2022 08:22 AM Page 4 of 8 u � Mason County Mason County - Division of Community Development 'l. 615 W.Alder St. Bldg.8 eec '''y Shelton,WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCEBLD2021-01661 Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC R403, applicable sections of the IRC, and IMC. Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers,filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants,gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure- sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts.When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. ..................... ....................__.-............._--------.__.__................ __.__..._.___.__._ The foundation/footing must b ........................................................ * Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. * All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way. ------ ---------- .__-------------------------------------------------------------- * REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. -------------..__--_-_____-.._____---------------------------- _..___.. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. -------------._.__-_--_ -_--_--.----_---__-__-__..-_----_._.----------_---------- .__. * Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. Printed by:Genie Mdadand on:02/25/2022 08:22 AM Page 5 of 8 Mason County h� Mason County - Division of Community Development ,l y 615 W.Alder St. Bldg.8 r�w Shelton,WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCEBLD2021-01661 * A permanent certificate, completed by the builder or registered design professional, shall be posted on a wall in the space where the furnace is located, a utility room,or an approved location inside the building.When located on the elctrical panel, the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect labek,or toher reqyired Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof,walls,foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC)of fenestration.Where'there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section R401.3& R402.4.1.2, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with IECC/.WSEC Section R402.4.1.2. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution - panel. Air leakage testing is not required for additions less than 500 square feet. Reference IECC/WSEC R402.4.1.2. Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2015 Certificate"and are available in '/<or'/2 sheet_s. The Mason County Permit Center will also have some available. ----.. --------------------------- .... ----- ...... * The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked "APPROVED",they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspectio -------- ----------------------- * All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. -------- ----- ----- ._--.. --_--.-------------- ----..------- ---------------------------- * WIND LOADS-Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. - ------------------------------ ---------------- ------ ---------------__-_.__------ * Concrete used for basement walls,foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). ------------------------------------------- * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. -------------------- ---------.. .------- ----------------------------------------------------------- ---------- * All-property lines shall be clearly identified at the time of foundation inspection. .......................... .... ..............................----------.........................- ....... * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site,approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. ------------------------------------------ ----------------------------------------------. ._ * The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. -------------------------------..-____.__---------------------------------------------_------------------------- * A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section R404.1. Printed by:Genie Mcfarland on:02/25/2022 08:22 AM Page 6 of 8 Mason County Mason County - Division of Community Development 615 W.Alder St. Bldg.8 Shelton,WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCEBLD2O21-01661 * Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. ---------------------------------v_..-.------_._-._... -.._-....---.....---._.--..----------------------- ----- --. * By definition, propane tanks and heatpumps are structures,which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed. ................................... ........_...._.---._..----.------- --------_-_-.-.-------------.. .. ._.. . * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. _________________ ________________-_..____--_---------.-----_._--_---_--_---_---__._____..___ ._.._.. * Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. * OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. _.____......,___.----------------------------------------------------.-___-_-_- --. .--- ___. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration.The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. ------------------------------------- -------------------------------------------------------------- ---------- * When parcel development requires direct access to state road(s), a Road Access Permit or Approval must be granted and approved by the Washington State Department of Transportation. For more information contact Washington State Department of Transportation, at(206)357-2620, ext. 630. ----------------- - ----------- -------------------------------- --- -------------------- -------------------- - ------ * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. ----------------------------- - ------------ -------- ----_--_-------..-.-------------------------- .-. .. .... * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982.The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. - ----------------- -- .__- _------------- _-------------------------------- ------------------ * All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site,then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. * Application acknowledges that the structure is only permitted for a use consistent with the current zoning of the parcel. - ----------------------- ----------- ----------- -------------------- --------------------------- --. * On-site Septic System final installation approval required prior to temporary/final occupancy of the residence. ------ --------------------------------------- ----------- -------------------------------- * Horizontal setbacks per WAC246-272A-0210 must be maintained, unless prior approval is obtained Printed by:Genie Mofarland on:02/25/2022 08:22 AM Page 7 of 8 Mason County Mason County - Division of Community Development 615 W.Alder St. Bldg.8 Shelton,WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCEBLD2021-01661 * Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered. A.) Drainfield/Reserve requires a 10ft setback from all footing/foundations. B.)Septic tank(s)requires 5ft setback from all footing/foundations. C.) No foundation/Perimeter Drains within 30ft, down gradient of Drainfield/Reserve area. D.) No Cut Bank(s) (greater than 5ft and over 45 degrees)within 50ft,down gradient of Drainfield/Reserve area. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: Contractor or Auth ized Agent: Date: 2 S 2Z Printed by:Genie Mcfarland on:02/25/2022 08:22 AM Page 8 of 8 51 NE Garrick Ln. Belfair, WA 98528 You cannot access our property from-Old Belfair HWY or Newkirk Rd - You must come'frog Hwy 3, and Log Yard Rd 51 NE Garrick Ln. . a - w:GaacickLn- -- .. Lind m a% �. aP A. railroad crossing ® Got Alle iearer Trucking .. &L scape supply,Inc Lit �p ' d y Driving toward Gorst on Hwy 3 s'ast right in Roundabout onto Log Yard Rd Left on Katchemak Ln s Goo le Go over railroad tracks, immediate right onto Katchemak Ln r 1 Map data ........... _..:. .. ...__. .. . .._.. _ ......... Left onto Garrick Ln. Bottom of hill, property on left side where 51 is marked on railroad tie Aim BMW", NOV 12 2021 616 W. AI , vt=�v PROPERTY LINE 317.16' Proposed 40'Private ET a0 Ebdriral Egress/Easement Trarmromrer Exisitng Retaining Wall Existing Retaining Wall (1 'i x`}fit T/� NE Ga rick Ln ?tj t li /'1 30'Private Easement Primary Drain Field _—A LT H 6'x 50' Primary Dram Field 15' 15' 6'x 50 � 9-3 2 1 -7 q -'1' oa 1 3 in W 20'x Heal Pump 1 / O Z Septic Tank " J v a m o CI LL IL M c c� uj n W M O x x p � 20'5 a House Site Proposed Well Location 40' x 68' Garage I WellRadus 26'x 34 197 O s � w m AY " X r z 79 68' 28' 1361 m Proposed Driveway APPROVE �ercr J AN 3 1 L��2 Proposed Walkway Stormwater Run Off Path AA50N COUNTY E LYL NM Existing Drivew y Existing Retammp Wall PROPERTY LINE 317.16' Site Plan N 1 20' 0 5 10 20 31 40 50 f Name Derek &Aliahna Watts Parcel# 12321-24-90083 BLD# Mason County Department of Community Development l -_ Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to"Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details*are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) AW a relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at: Phone:(360)-427-9670 EXT.450 Mail:P 0 Box 1850,Shelton WA 98584 Physical:415 N 6th St, Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason County Division of Environmental Health can be reached at: Phone:(360)-427-9670 EXT. 352 Mail:P 0 Box 1666, Shelton WA 98584 Physical:426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further Nmowledge that the information provided is accurate and employees of Mason County are granted access to the above- descriprortyr review and inspection as may be required. X Owner/ gent/Contractor(circle one)Date: 11/12/2021 Page 2 � s Name Derek&Aliahna Watts Parcel# 12321-24-90083 BLD# I Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14, Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment', with more than 2,000 square feet of impervious surface'. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction, installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area "All dimensions in feet Buildings X = = Measurements for buildings are taken at the 68 X 40 2720 68 X 28 = 72 perimeter of the farthest projections(example: eaves/gutters) X = Driveways X X = Length of drive begins at the right of way X = Parking Areas X X = Any paved, gravel or packed area per definition above table X = Patios/Walks X 10 X 20 = 200 Any paved, gravel or packed area per definition above table 10 X 20 = 200 Others X X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) 4072 If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read, acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor. I further acknow dge that the information provided is accurate and employees of Mason County are granted access to the above- described proTIperrvious review and inspection as may be required. X Owne Agent/Contractor(circle one)Date: 11/12/2021 If the Total Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 MASON COUNTY COMMUNITY SERVICES _Permit No: PERMIT ASSISTANCE CENTER: .BUILDING•PLANNING•PUBLIC HEALTH•FIRE MARSHAL J"` 615 W.Alder Street,Shelton,WA 98584 t � ['""'� ] n Phone Shelton:(360)427-9670 ext 352•Fax:(360)427-7798 Phone ��Y I y f�`f.= ` ° -• Belfair.(360)275-4467•Phone Elma:(360)482-5269 _.1:-' S'li Fri•, . BUILDING PERMIT APPUdATION PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: NAME:Derek&Aliahna Watts NAME:same as owner MAILING ADDRESS:Po emk 2W MAILING ADDRESS: CITY:Belfair STATE:WA ZIP:98528 CITY: STATE: ZIP: PHONE#1:360-801-"" PHONE: CELL: PHONE#2:775.822-2197 EMAIL: EMAIL:allahnamariez@gmafl.com L&I REG# EXP. PRIMARY CONTACT: OWNER 0 CONTRACTOR❑ OTHER❑ NAME Niahnawatta EMAIL aliahnamarie2fgmall.mrn MAILING ADDRESS PO Box 26W CITY Betfalr STATE WA ZIp 98528 PHONE 3848e154" CELL 360-s01-5404 PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number) 12321-24-MM ZONING R4 LEGAL DESCRIPTION(Abbreviated) Lot 3 of SP#3139 AF#216630 PTN of SE NW FIRE DISTRICT North Mason Rre SITE ADDRESS 51 NE Garrick Ln. CITY Belfair DIRECTIONS TO SITE ADDRESS t"3 to Gorst,Left on Log Yard Rd,Left on Katchemak Ln,over rail road tracks take immediate right turn(still Katchemak Ln),left on Garrick,access to 51 Garrick Ln at bottom of hill on left side IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES❑ NO❑� SNOW LOAD:_psf IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (irhea aadwapply): SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ TYPE OF WORK: NEW EI ADDITION❑ ALTERATION❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(Residence,Garage.Commercial Bldg,Etc.)Residence wM attached garage IS USE: PRIMARY❑+ SEASONAL❑ NUMBER OF BEDROOMS 4 NUMBER OF BATHROOMS 2.5 HEATED STRUCTURE? YES(Whole Bug)❑ YES(Part[s]of Bldg) i❑ NO❑ DESCRIBE WORK New single family dwelling with attached unheated garage SOUARE FOOTAGE:proposed) 1 ST FLOOR 27Yo sq.& 2ND FLOOR sq.& 3RD FLOOR sq.& BASEMENT sq.& DECK sq.& COVERED DECK 400 sq.& STORAGE sq.& OTHER sq.ft. GARAGE 962 sq.& Attached❑+ Detached❑ CARPORT sq.ft Attached❑ Detached❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE MODEL YEAR LENGTH WIDTH BEDROOMS BATHS SERIAL NUMBER ENVIRONMENTAL HEALTH: SEWAGEISEWER SOURCE: SEPTIC❑+ SEWER❑ / NEW[a EXISTING❑ PLUMBING IN STRUCTURE? YES❑+ NO❑ If yes,attach completed Water Adequacy Form PERIMETERIFOUNDATION DRAINS PROPOSED? YES❑ NOD EXISTING SQ.Fr. EXISTING BEDROOMS PROPOSED BEDROOMS 4 TOTAL BEDROOMS 4 OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PER41UCATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON COUNTY CODE 14.08.42) X 11/12/21 Siriature aFOVIINER(Must be signed by the OWNER) Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT /-3/XZ PLANNING DEPARTMENT FIRE MARSHAL PUBLIC HEALTH 10 MASON COUNTY COMMUNITY SERVICES_ _ Permit No: - 1 PERMIT ASSISTANCE CENTER: r •BUILDING •PLANNING •FIRE MARSHAL 615 W.Alder St-Shelton, WA 98584 I "� � g www.co.mason.wa.us NOV4 V I LD I �3 Phone Shelton:(360)427-9670 ext. 352- Fax:(360)427-7.798. V/. Phone Belfair.-(360)275-4467- Phone Elma:(360)482-5269 PLUMBING & MECHANICAL PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFORMATION: NAME:Derek&Aliahna Watts NAME:same as owner MAILING ADDRESS:Po Box 2666 MAILING ADDRESS: CITY:Belfair STATE:WA ZIP:98528 CITY: STATE: ZIP: Ist PHONE:36o-aot-54o4 PHONE: CELL: 2°d PHONE:775-622-2197 EMAIL : EMAIL:aliahnamarie2@gmail.com L&I REG# EXP. PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number):12321-24-90083 Zoning:R4 LEGAL DESCRIPTION(Abbreviated):Lot 3 of SP#3139 AF#216630 PTN of SE NW SITE ADDRESS:51 NE Garrick Ln.Belfair WA 98528 CITY:Belfair DIRECTIONS TO SITE ADDRESS: Hwy 3 to Gorst, Left on Log Yard Rd, Left on Katchemak Ln,over rail road tracks take immediate right turn (still on Katchemak Ln), left on Garrick Ln,access to 51 NE Garrick at bottom of hill on left side TYPE OF JOB: NEW 0✓ ADD=ALT=REPAIR=OTHER USE OF BUILDING residence LOCATION OF FIXTURES/UNITS—1ST FLOOR✓]2ND FLOOR=BASEMENT=GARAGE=OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No.of Fixtures Fees Fuel Type:Electric LPCJ:: Vatural GasE�Ductless0 Toilets 3 27 Type of Unit No.of Units Fees Bathroom Sink 5 45 Furnace Bath Tubs 2 18 Heat Pump 1 19 Showers 3 27 Spot Vent Fan 3 30 Water Heater 1 9 Propane Tank Clothes Washer 1 9 Gas Outlets Kitchen Sinks 1 9 Wood/Gas/Pellet Stove 1 Dishwasher 1 9 Kitchen Exhaust Hood 1 14 Hose bibs 2 18 Dryer Vent Other Solar Panel Other Air Handler-1 14 Base Fee 25 Base Fee 30 TOTAL PLUMBING 178 TOTAL MECHANICAL OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that 1 am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permitlapplication becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL TE THE APPLICATION. X I LI A 11/12/21 gna re f Owner Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL Rev:1/27/2016 1BN