HomeMy WebLinkAboutBLD2021-01661 SFR - BLD Inspections - 1/13/2023 615 W.Alder St.Bldg 8,SHELTON,WA 98684
MASON COUNTY SHELTON:360-427-9670,EXT 352
COMMUNITY SERVICES BELFAIR:360-275-4467,EXT 352
Building,Planning,Environmental Health,Community Health ELMA:360-482-5269,EXT 352
www.co.mason.wa.us
INSPECTION CARD AND CERTIFICATE OF OCCUPANCY"
To schedule an inspection call or visit http://www.co.mason.wa.us/community-services/bid-inspection.php
Permit Number BLD2021-01661 Date Issued 02/25/2022 Issued By
Project New SFR
Site Address 51 NE GARRICK LN
Applicant DEREK&ALIAHNA WATTS
Contractor
Contractor Phone
Primary Code UPC IBC,IRC,IFC,IEC,IMC,& Type
Permit Type .NEW SINGLE FAMILY RESIDENCE Occupancy
-APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS.
-DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED.
-THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION,FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY.
-ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION.
-OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION.
"THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED"
PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET
Public Works Access/Driveway Other
Health Septic Well
Deptartment
Planning Site Inspection
Department
Fire Marshall Fire Apparatus Access Fire Sprinkler
Auto Fire Alarm Hood and Duct
Other Final
Building Building Official: Community Services Designee
Department
Concrete Setbacks Z,- LV_z-:L&17d Slab
Footing Perimeter 1, Point load Footing
Footing Interior Footing Decks/Porches
Foundation Stem Walls DbC Other
Rough-In Groundwork Plumbing Framing
Groundwork Mechanical Plumbing
Groundwork Gas Pipe Mechanical
Gas Piping Shear Wall Nailing
Underfloor
Other
Insulation Slab Ceiling
Floor Vaulted Ceiling
Walls Vapor Barrier
Other
Wallboard Interior Wall Brace Panels Fire Walls
Nailing
Other
Final Building
Manufactured Setbacks Setup
Home
Concrete Foot/Runners Final
Other
. � BUILDING
MASON COUNTY
d
615`�° F COMMUNITY SERVICES
Building,Planning,Environmental He ilth,Community a eolth
These requirements apply to all IRC building types, including detached one-and two-family dwellings and multiple
S single-family dwellings(townhouses).
Contact Information Project Information
Owners Name: ite Address:
J Derek&Aliahna Watts 51 NE Garrick Ln.
Mailing Address: Belfair,WA 98528
PO Box 2666
Belfair WA 98528 Parcel Number:
12321-24-90083
Square Feet(total):
2720
Ventilations Compliance:
OWhole House Ventilation system 0 Whole House Ventilation
using exhaust fans&window or wall Integrated with a Forced Air
fresh air vents(M1507.3.4) System(M1507.3.5)
Other, describe:
Instructions:This single-family project will use the requirements of the Prescriptive Path below and
incorporate the minimum values listed. Based on the size of the structure, the appropriate number of
additional credits are checked as chosen by the permit applicant.
Provide all information from the following tables as building permit drawings:Table R402.1- Insulation and
Fenestration Requirements by Component,Table R406.2- Fuel Normalization Credits and 406.3- Energy Credits.
All Climate Zones(Table 11402.1.1)
R-Value' U-Factora
Fenestration U-Factorb n/a 0.30
Skylight U-Factor b n/a 0.50
Glazed Fenestration SHGC bje n/a n/a
Ceiling a 49 i 0.026
Wood Frame Wall g,h 21 int 0.056
Floor 30 0.029
Below Grade Wall`,h 10/15/21 int+TB 0.042
Slab d,f R-Value& Depth 10, 2 ft n/a
R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity that is less
a than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix
Table A101.4 shall not be less than the R-value specified irf the table.
b The fenestration U-factor column excludes skylights.
"10/15/21+5TB" means R-10 continuous insulation on the exterior of the wall,or R-15 continuous insulation on
the interior of the wall,or R-21 cavity insulation plus a thermal break between the slab and the basement wall at
c the interior of the basement wall. "10/15/21+5TB"shall be permitted to be met with R-13 cavity insulation on
the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB"
means R-5 thermal break between floor slab and basement wall.
d I R-10 continuous insulation is required under heated slab on grade floors.See Section R402.2.9.1.
Prescriptive Path—Single Family 2018 Washington State Energy Code-R
{
r
For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38 if the full insulation depth
e extends over the top plate of the exterior wall.
R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter
f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used,it shall
meet the requirements for thermal barriers protecting foam plastics.
For log structures developed in compliance with Standard [CC 400, log walls shall meet the requirements for
g climate zone 5 of ICC 400.
Int. (intermediate framing)denotes framing and insulation as described in Section A103.2.2 including standard
h framing 16 inches on center,78%of the wall cavity insulated and headers insulated with a minimum of R-10
insulation.
Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel
normalization credits)and Table 406.3(energy credits) to achieve the following minimum number of
credits.To claim this credit,the building permit drawings shall specify the option selected and the
maximum tested building air leakage and show the qualifying ventilation system and its control sequence
of operation.
1. Small Dwelling Unit: 3 credits
Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area.
Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf.
2. Medium Dwelling Unit:6 credits
All dwelling units that are not included in#1 or#3
3. Large Dwelling Unit: 7 credits
Dwelling units exceeding 5,000 sf of conditioned floor area
4. Additions less than 500 square feet: 1.5 credits
All other additions shall meet 1-3 above
Before selecting your credits on this Summary table, review the details.in Table 406.3(Single Family),on page 4.
Summary of Table R406.2
Heating Credits-select ONE
Options Fuel Normalization Descriptions heating option User Notes
1 Combustion heating minimum NAECAb 0.0 ❑
2 Heat pump` 1.0 ❑✓
3 Electric resistance heat only-furnace or zonal -1.0 ❑
4 DHP with zonal electric resistance per option 3.4 0.5 ❑
5 All other heating systems -1.0 ❑
Energy Credits-select ONE
Options Energy Credit Option Descriptions energy option from each
p cate or
1.1 Efficient Building Envelope 0.5 ❑
1.2 Efficient Building Envelope 1.0 ❑
1.3 Efficient Building Envelope 0.5
1.4 Efficient Building Envelope 1.0 ❑
1.5 Efficient Building Envelope 2.0 ❑
1.6 Efficient Building Envelope 3.0 ❑
1.7 Efficient Building Envelope 0.5 ❑
2.1 Air Leakage Control and Efficient Ventilation 0.5 ❑✓
2.2 Air Leakage Control and Efficient Ventilation 1.0 ❑
2.3 Air Leakage Control and Efficient Ventilation 1.5 ❑
2.4 Air Leakage Control and Efficient Ventilation 2.0 ❑
3.1a High Efficiency HVAC 1.0 ❑
3.2 High Efficiency HVAC 1.0 ❑✓
3.3a High Efficiency HVAC 1.5 ❑
3.4 High Efficiency HVAC 1.5 ❑
3.5 High Efficiencv HVAC 1.5 ❑
3.6a High Efficiency HVAC 2.0 ❑
Prescriptive Path-Single Family 2018 Washington State Energy Code-R
4.1 High Efficiency HVAC Distribution System 0.5 ❑✓
4.2 High Efficiency HVAC Distribution System 1 1.0 ❑
5.1d Efficient Water Heating 0.5 ❑
5.2 Efficient Water Heating 0.5 ❑
5.3 Efficient Water Heating 1.0 ❑
5.4 Efficient Water Heating 1.5 ❑
5.5 Efficient Water Heating 2.0 ❑✓
5.6 Efficient Water Heating 2.5 ❑
6.1e Renewable Electric Energy(3 credits max) 1.0 ❑
7.1 Appliance Package 0.5 X❑
Total 6
Credits
a. An alternative heating source sized at a maximum of 0.5 W/sf(equivalent)of heated floor area or 500 W,
whichever is bigger, may be installed in the dwelling unit.
b. Equipment listed in Table C403.3.2(4)orC403.3.2(5)
c. Equipment listed in Table C403.3.2(1)orC403.3.2(2)
d. You cannot select more than one option from any category EXCEPT in category 5.Option 5.1 may be combined
with options 5.2 through 5.6.See Table 406.3.
e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max.
See the complete Table R406.2 for all requirements and option descriptions.
Please print only:pages 1 through 3 of this workshdet for submission to your building official:`
Prescriptive Path—Single Family 2018 Washington State Energy Code-R
I� TE rr t r t(CAL [y KANU r RED HOME
its-
Gas Kping
Irpterioc DEW BY IrYrerior-Dafe BY Dint-
By Ext--rbr-Dad:. By- � -
l olc2f a lsc�: erl ?CRi31 INSULATION nit=
as t SIAM INSULATION BY
Dat_ By Dam By FIRE DEPARTMENT
r-wrididlon Walls
Dzde• By DECK5
FRAMING W41It Date BY
Date By Data By PROPANETANKS
Data- -- SY OTHER
ei Atbr
Y1�
L}at�t gar DAM - �} .
Date By
D-Wv [DRYWALL Type:
Int Brace wall
Date BY �nate �Y � By
N - FINAL INSPECTION
CD Fire seper�aton
Date By €da By De:e BY
m
Pass or Request Crtspe-at.
5 TYPO Of FnSP Fat[ Data Data Done ByCD Comments
Z
5 -n-Z1-CD
CD
i
0
f
# 57-
y SS — 22
-�
a I
CD
Ot; � -1
t o
co
° tS 1-13-.231 DE
A
MASON COUNTY 360-427-9670 Shelton ext.352
COMMUNITY SERVICES 36 60-482-52 Belfair ext.352
' 360-482-5269 Elma ext.352
Building,Planning,Environmental Health,Community Health
615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov
CORRECTION/INSPECTION REPORT
PERMIT/CASE NUMBER: 15 L t7 20 Z-1 — 61 U Le/
ADDRESS/LOCATION: 5'1 NE- b, go/o4 I�
i
FIN PINGS:
11 Veg ty -Ae*w -W_ z 2 I�
?-too v.A�- i
02.E Sp fib mv_c)
Jeff
/✓O(Jl C G �'N �'f g� Vgc4 40dw
l Q tit
�C r e A -s ve- a lib ih
vc✓N et C%✓e- Q .f
lril- Co►-vrr� Zvi spa/lam -(fr!�,_ / /tom c;� GZ�iGY�s t a HW
!!/lS e—e a 71k 6 f&L la4_
Items listed above must be corrected to gain compliance.
❑ THIS IS NOT A COMPLETE INSPECTION
❑ This structure has been inspected by Mason County Building Department and the items listed
above are in VIOLATION of Mason County laws and/or ordinances.
❑ Call for re-inspection when corrections are made before proceeding with any further work. � �
Make corrections, items will be checked on the next inspection.
❑ OK to
Date: `T'l�- Z Z ❑ Please contact our office regarding possible
Department: structural damage incurred by recent
Inspector: J� "natural/man made"disasters.This is NOT a
CORRECTION NOTICE.
DO NOT REMOVE THIS. TAG
MCC14.12
MASON COUNTY 360-427-9670 Shelton ext.352
360-275-4467 Belfair ext.352
COMMUNITY SERVICES 360-482-5269 Elma ext.352
Building,Planning,Environmental Health,Community Health
0615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov
CORRECTION/INSPECTION REPORT
PERMIT/CASE NUMBER:_,��A�-01-- �\�tl VQ \
ADDRESS/LOCATION: �\ IV ai AK Y'\C\L
DINGS:
YV
Y
Items listed above must be corrected to gain compliance.
❑ THIS IS NOT A COMPLETE INSPECTION
❑ This structure has been inspected by Mason County Building Department and the items listed
above are in VIOLATION of Mason County laws and/or ordinances.
Call for re-inspection when corrections are made before proceeding with any further work.
ake corrections,items will be checked on the next inspection.
❑ OK too
Date: `A�L Z2- ❑ Please contact our office regarding possible
Department: LD structural damage incurred by recent
Inspector: AU p{of Z-, . "natural/man made"disasters.This is NOT a
CORRECTION NOTICE.
DO NOT REMOVE THIS. TAG
MCC14.12
Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg.8
Hi Shelton,WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
B DD2021-01661 NEW SINGLE FAMILY RESIDENCE
PROJECT DESCRIPTION: NEW SFR ISSUED: 02/25/2022
SITE ADDRESS: 51 NE GARRICK LN BELFAIR
EXPIRES: 08/24/2022
PARCEL: 123212490083
APPLICANT: DEREK&ALIAHNA WATTS OWNER: DEREK&ALIAHNA WATTS
PO BOX 2666 PO BOX 2666
BELFAIR,WA98528 BELFAIR,WA98528
360.801.5404
VALUATIONS: FEES: Paid Due
R-3 VB Residential, one- 2720.00 $403,457.60 Planning Review Fee $240.00 $0.00
and two-family State Fee-Residential $6.50 $0.00
Covered Deck/Carport 400.00 $8,800.00 Plan Check Fee $2,188.00 $0.00
U VB Utility, miscellaneous 952.00 $57,005.76 Building Plan Review/Change of $125.00 $0.00
Use-Onsite Sewage
Mechanical Fees $172.00 $0.00
Plumbing Base Fee $25.00 $0.00
Mechanical Base Fee $30.00 $0.00
Plumbing Fees $167.00 $0.00
Building Permit Fee $3,366.16 $0.00
Technology Surcharge $118.96 $0.00
Total: $469,263.36 Totals : $6,438.62 $0.00
FIXTURES
Qty Mechanical Fixtures Qty Plumbing Fixtures
1.0000 Dryer Vent(s) 1.0000 Number of Clothes Washers
1.0000 Kitchen Exhaust Hood(s) 1.0000 Number of Dishwashers
1.0000 Furnace(s) 1.0000 Number of Kitchen Sinks
1.0000 Heat Pump(s) 1.0000 Number of Water Heaters and or Vent
1.0000 Wood/Gas/Pellet Stove(s) 2.0000 Number of Hose Bibs
Printed by:Genie Mcfarland on:02/25/2022 08:22 AM
Page t of 8
Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg.8
Shelton,WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCE BLD2021-01661
.City Mechanical Fixtures Qty Plumbing Fixtures
3.0000 Spot Vent Fan(s) 2.0000 Number of Bath Tubs
3.0000 Number of Showers
3.0000 Number of Toilets
5.0000 Bathroom Sink
REQUIRED INSPECTIONS
Setback Inspection Framing Inspection
-----------------------------------------------------.
Footing Inspection Rough-Plumbing Inspection
-----------------------------------------------------. _. _ _ — — — _ _ _
Foundation Wall-Pre-Pour Inspection Mechanical Inspection
----------------------- --------- ------------------
Underfloor Inspection Insulation Inspection
-----------------------------------------------------.
Shearwall Inspection BLD-Final Inspection
CONDITIONS
* When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by
the Mason County Department of Public Works. For more information contact Public Works, at(360)427-9670, ext.450 or
100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the
access permit from Public Works has been finaled and approved.
Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site
plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed.
--------------- ------. ---------------------------------- ---------------------------------- -------------. ---
" Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a
permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor
&Industries (L&I).
For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415-
4000.
The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more
than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards
for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to
another fire apparatus access road which connects to a county maintained public road.
Printed by:Genie Mcfarland on:02/25/2022 08:22 AM
Page 2 of 8
Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg.8
Shelton,WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCEBLD2021-01661
Adopted IECC/Washington State Energy Code Compliance has been approved as follows:
Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window(Max U-
Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less,Wall insulation R-21, Floor insulation
R-30, Ceiling Insulation min. R-49,Vault Insulation R-38, and Slab Insulation R-10.
Fuel Normalization Credits:Table 406.2
2 Heat pump
Table 406.3—Energy Credits(Single Family)
1.3 Prescriptive compliance is based on Table R402.1.1 with the following modifications:
Vertical fenestration U =0.28, Floor R-38, Slab on grade R-10 perimeter and under entire slab below grade slab R-10
perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by 5%
2.1 Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per hour.
maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested air
leakage to 0.3 cfm/sf maximum at 50 Pascals and All whole house ventilation requirements as determined by Section
M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a
high efficiency fan(s)(maximum 0.35 watts/cfm), not interlocked with the furnace fan (if present).Ventilation systems using a
furnace including an ECM motor are allowed if they are controlled to operate at low speed in ventilation only mode.
3.2 Air-source centrally ducted heat pump with minimum HSPF of 9.5. 3
4.1 All supply and return ducts located in an unconditioned attic shall be deeply buried in ceiling insulation in accordance
with Section R403.3.7. For mechanical equipment located outside the conditioned space, a maximum of 10 linear feet of
return duct and 5 linear feet of supply duct connections to the equipment may be outside the deeply buried insulation. All
metallic ducts located outside the conditioned space must have both transverse and longitudinal joints sealed with mastic. If
flex ducts are used, they cannot contain splices.
Duct leakage shall be limited to 3 cfm per 100 square feet of conditioned floor area.Air handler(s)shall be located within the
conditioned space.
5.1 A drain water heat recovery unit(s)shall be installed,which captures wastewater heat from all and only the showers and
has a minimum efficiency of 40% if installed for equal flow or a minimum efficiency of 54% if installed for unequal flow. Such
units shall be rated in accordance with CSA B55.1 or IAPMO IGC 346-2017 and be so labeled. To qualify to claim this credit,
the building permit drawings shall include a plumbing diagram that specifies the drain water heat recovery units and the
plumbing layout needed to install it. Labels or other documentation shall be provided that demonstrates that the unit
complies with the standard.
5.4 Water heating system shall include one of the following:
Electric heat pump water heater meeting the standards for Tier I of NEEA's advanced water heating specification or for R-2
Occupancy,electric heat pump water heater(s), meeting the standards for Tier I of NEEA's advanced water heating
specification, shall supply domestic hot water to all units. If one water heater is serving more than one dwelling unit, all hot
water supply and recirculation piping shall be insulated with R-8 minimum pipe insulation. 5
7.1 All of the following appliances shall be new and installed in the dwelling unit and shall meet the following standards:
Dishwasher—Energy Star rated
Refrigerator(if provided)—Energy Star rated washing machine—Energy Star rated
Dryer—Energy Star rated,ventless dryer with minimum CEF rating of 5.2, all appliances shall be installed and connected to
utilities. Dryer ducts and exterior dryer vent caps are not permitted to be installed in the dwelling unit.
Printed by:Genie Mcfarland on:02/25/2022 08:22 AM
Page 3 of 8
1
Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg.8
tea, Shelton,WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCEBLD2O21-01661
* A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit
application. Design,sizing, placement, inspection and maintenance of stormwater management systems shall be the
responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that
Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement
of any development activities. "NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater
Management Application/Worksheet the document entitled"Managing Storm Drainage on Small Lots,The Small Parcel
Stormwater Site Plan"constitutes an approved plan based on the criteria listed on the application/worksheet. If the
development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,
parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final
inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater
management system have been installed as approved on the stormwater site plan.
Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and
MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either
private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an
existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance
and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting
from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any
construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that
office to review future planned work which may affect your project.
------- -------- --------------------- --------_. -- - --------
Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer
specifications and in accordance with IRC Section R315.
Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level
of the dwelling.
EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations(including addition or alteration of
fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or
-created.
Printed by:Genie Mcfarland on:02/25/2022 08:22 AM
Page 4 of 8
u �
Mason County
Mason County - Division of Community Development
'l. 615 W.Alder St. Bldg.8
eec '''y Shelton,WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCEBLD2021-01661
Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC
R403, applicable sections of the IRC, and IMC.
Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the
purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including
infiltration and ventilation. Design calculations shall be available for inspection during inspection.
Referencing IRC M1601.4, all ducts, air handlers,filter boxes, and building cavities shall be sealed. All joints of duct
systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants,gasketing or other
approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be
marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used
with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-
sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings
shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B
and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm)
and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint.
Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation
instructions.
Duct tape is NOT permitted as a sealant on any ducts.When ducts are located in unheated spaces the ducts hall be
insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit
documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building
Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website
titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not
required if the air handler and all ducts are located within the heated space.
..................... ....................__.-............._--------.__.__................
__.__..._.___.__._
The foundation/footing must b ........................................................
* Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly
corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of
pressure treated material.
* All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor
increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way.
------ ---------- .__--------------------------------------------------------------
* REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable
provisions of the current code and the manufacturer's installation instructions.
A drip edge shall be provided at eaves and gables of shingle roofs.
-------------..__--_-_____-.._____----------------------------
_..___..
* All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as
adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted
classification. Any non-approved change of use or occupancy would result in permit revocation.
-------------._.__-_--_ -_--_--.----_---__-__-__..-_----_._.----------_----------
.__.
* Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate
building permit and approval prior to construction of the retaining wall.
Printed by:Genie Mdadand on:02/25/2022 08:22 AM
Page 5 of 8
Mason County
h� Mason County - Division of Community Development
,l y 615 W.Alder St. Bldg.8
r�w Shelton,WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCEBLD2021-01661
* A permanent certificate, completed by the builder or registered design professional, shall be posted on a wall in the space
where the furnace is located, a utility room,or an approved location inside the building.When located on the elctrical panel,
the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect labek,or toher reqyired
Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof,walls,foundation (slab,
basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the
solar heat gain coefficient(SHGC)of fenestration.Where'there is more than one value for each component, the certificate
shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service
water heating equipment, duct leakage rates including test conditions as specified in WSEC Section R401.3& R402.4.1.2,
and air leakage results if a blower door test was conducted.
Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air
changes per hour when tested with a blower door in accordanve with IECC/.WSEC Section R402.4.1.2.
The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution -
panel. Air leakage testing is not required for additions less than 500 square feet. Reference IECC/WSEC R402.4.1.2.
Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2015 Certificate"and are
available in '/<or'/2 sheet_s. The Mason County Permit Center will also have some available.
----..
--------------------------- .... ----- ......
* The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility
of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked
"APPROVED",they shall not be changed or altered without authorization from the Building Official. The permit holder is
responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of approved documents will result in failure of required building inspectio -------- -----------------------
* All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or
any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction.
-------- ----- ----- ._--.. --_--.-------------- ----..------- ----------------------------
* WIND LOADS-Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind
speed for Mason County is 85 MPH.
- ------------------------------ ---------------- ------ ---------------__-_.__------
* Concrete used for basement walls,foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather,
garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of
3000 psi (IRC Table R402.2).
-------------------------------------------
* All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building
Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration.
Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No
more than one extension may be granted.
-------------------- ---------.. .------- ----------------------------------------------------------- ----------
* All-property lines shall be clearly identified at the time of foundation inspection.
.......................... .... ..............................----------.........................- .......
* The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the
approved site plan is not on site,approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule,
minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being
performed or approvals granted.
------------------------------------------ ----------------------------------------------. ._
* The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not
allowed without the approval of the Mason County Fire Marshal.
-------------------------------..-____.__---------------------------------------------_-------------------------
* A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance
with IECC/WSEC Section R404.1.
Printed by:Genie Mcfarland on:02/25/2022 08:22 AM
Page 6 of 8
Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg.8
Shelton,WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCEBLD2O21-01661
* Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and
MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either
private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an
existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance
and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting
from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any
construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that
office to review future planned work which may affect your project.
---------------------------------v_..-.------_._-._... -.._-....---.....---._.--..----------------------- ----- --.
* By definition, propane tanks and heatpumps are structures,which must meet setback conditions. Please check your
"Approved Site Plan"to ensure these structures meet the setback conditions listed.
................................... ........_...._.---._..----.------- --------_-_-.-.-------------.. .. ._.. .
* CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING
DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All
construction must be in conformance with the international codes as amended and adopted by Mason County. Any
corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting
additional inspections.
_________________ ________________-_..____--_---------.-----_._--_---_--_---_---__._____..___ ._.._..
* Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the
structure.
* OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit
revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or
contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained
permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County
access to the above described property and structure(s)for review and inspection.This permit/application becomes null &
void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of
180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT
APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
_.____......,___.----------------------------------------------------.-___-_-_- --. .---
___.
* All building permits shall have a final inspection performed and approved by Mason County Building Department prior to
permit expiration.The failure to request a final inspection or to obtain approval will be documented in the legal property
records on file with Mason County as being non-compliant with Mason County ordinances and building regulations.
------------------------------------- -------------------------------------------------------------- ----------
* When parcel development requires direct access to state road(s), a Road Access Permit or Approval must be granted and
approved by the Washington State Department of Transportation. For more information contact Washington State
Department of Transportation, at(206)357-2620, ext. 630.
----------------- - ----------- -------------------------------- --- -------------------- -------------------- - ------
* Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance
with Mason County Title 14.28 and 14.17.
----------------------------- - ------------ -------- ----_--_-------..-.-------------------------- .-. .. ....
* Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries,
Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an
unregistered contractor. Further information can be obtained at 1-800-647-0982.The person signing this condition is either
the homeowner, agent for the owner or a registered contractor according to WA state law.
- ----------------- -- .__- _------------- _-------------------------------- ------------------
* All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and
plans are not available on site,then approval will not be granted. In addition, a re-inspection fee (refer to current fee
schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections
being performed or approvals granted.
* Application acknowledges that the structure is only permitted for a use consistent with the current zoning of the parcel.
-
----------------------- ----------- ----------- -------------------- --------------------------- --.
* On-site Septic System final installation approval required prior to temporary/final occupancy of the residence.
------ --------------------------------------- ----------- --------------------------------
* Horizontal setbacks per WAC246-272A-0210 must be maintained, unless prior approval is obtained
Printed by:Genie Mofarland on:02/25/2022 08:22 AM Page 7 of 8
Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg.8
Shelton,WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCEBLD2021-01661
* Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered.
A.) Drainfield/Reserve requires a 10ft setback from all footing/foundations.
B.)Septic tank(s)requires 5ft setback from all footing/foundations.
C.) No foundation/Perimeter Drains within 30ft, down gradient of Drainfield/Reserve area.
D.) No Cut Bank(s) (greater than 5ft and over 45 degrees)within 50ft,down gradient of Drainfield/Reserve area.
I hereby certify that I have read and examined this application and know the same to be true and correct.
All provisions of Laws and Ordinances governing this type of work will be complied with whether
specified herein or not. The granting of a permit does not presume to give authority to violate or cancel
the provisions of any other state/local law regulating construction or the performance of construction.
Issued By:
Contractor or Auth ized Agent: Date: 2 S 2Z
Printed by:Genie Mcfarland on:02/25/2022 08:22 AM Page 8 of 8
51 NE Garrick Ln. Belfair, WA 98528
You cannot access our property from-Old Belfair HWY or Newkirk
Rd - You must come'frog Hwy 3, and Log Yard Rd
51 NE Garrick Ln. . a
- w:GaacickLn- --
.. Lind
m a%
�. aP
A.
railroad crossing
® Got
Alle iearer Trucking
.. &L scape supply,Inc
Lit
�p
' d y
Driving toward Gorst on Hwy 3
s'ast right in Roundabout onto Log Yard Rd
Left on Katchemak Ln s
Goo le
Go over railroad tracks, immediate right onto Katchemak Ln r 1 Map data
........... _..:. .. ...__. .. . .._.. _ .........
Left onto Garrick Ln.
Bottom of hill, property on left side where 51 is marked on
railroad tie
Aim BMW",
NOV 12 2021
616 W. AI , vt=�v
PROPERTY LINE
317.16' Proposed 40'Private ET
a0 Ebdriral Egress/Easement
Trarmromrer
Exisitng
Retaining Wall
Existing
Retaining Wall (1 'i x`}fit T/�
NE Ga rick Ln ?tj t li /'1
30'Private Easement
Primary Drain Field _—A LT H
6'x 50'
Primary Dram Field
15' 15' 6'x 50
� 9-3 2 1 -7 q -'1' oa 1 3
in
W 20'x Heal Pump 1 / O
Z Septic Tank "
J v a
m o
CI LL IL
M c c�
uj n
W M O x x
p � 20'5
a
House Site Proposed
Well Location
40' x 68' Garage I WellRadus
26'x 34 197
O
s �
w m
AY " X
r
z
79 68' 28' 1361 m
Proposed Driveway
APPROVE
�ercr
J AN 3 1 L��2
Proposed Walkway
Stormwater Run
Off Path AA50N COUNTY E LYL NM
Existing Drivew y
Existing Retammp Wall
PROPERTY LINE
317.16'
Site Plan
N 1 20'
0 5 10 20 31 40 50
f
Name Derek &Aliahna Watts Parcel# 12321-24-90083 BLD#
Mason County
Department of Community Development l -_
Small Parcel Stormwater Management Application/Worksheet (page 2 of 2)
Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity.
Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater
Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website:
http//www.co.mason.wa—us/code/commissioners/index.htm
Please follow the links to"Title 14,Chapter 14.48 Stormwater Management".
Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan
(Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document
entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist
you in preparing the necessary information and plans for Public Works to review and approve. Per Department of
Public Works this document will constitute an approved plan if all of the relevant details*are to be installed in
their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health
information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval.
A design by a registered professional may be required for more complex sites.
*These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan
on the pages that begin with"Handout"
PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE
A) AW a relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed
in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel.
B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the
system will be located as not to adversely affect any septic systems on this,or any other,parcel.
If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works
Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at:
Phone:(360)-427-9670 EXT.450
Mail:P 0 Box 1850,Shelton WA 98584
Physical:415 N 6th St, Shelton WA 98584
If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or
any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason
County Division of Environmental Health can be reached at:
Phone:(360)-427-9670 EXT. 352
Mail:P 0 Box 1666, Shelton WA 98584
Physical:426 W Cedar St, Shelton WA 98584
A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met
prior to a request for final inspection of the building permit.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further Nmowledge that the information provided is accurate and employees of Mason County are granted access to the above-
descriprortyr review and inspection as may be required.
X Owner/ gent/Contractor(circle one)Date: 11/12/2021
Page 2
� s
Name Derek&Aliahna Watts Parcel# 12321-24-90083 BLD#
I
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 1 of 2)
Per Mason County Code,Title 14, Chapter 14.48 a stormwater site plan is required whenever a building application is
made for residential development,or redevelopment', with more than 2,000 square feet of impervious surface'.
'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development
including construction, installation or expansion of a building or other structure,and/or replacement of impervious surface that is not
part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment.
'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas,
concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the
natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces.
To Calculate Impervious Surfaces Please Complete This Table
Surface Type Length X Width = Area "All dimensions in feet
Buildings X =
= Measurements for buildings are taken at the
68 X 40 2720
68 X 28 = 72 perimeter of the farthest projections(example:
eaves/gutters)
X =
Driveways X
X = Length of drive begins at the right of way
X =
Parking Areas X
X = Any paved, gravel or packed area per definition
above table
X =
Patios/Walks X
10 X 20 = 200 Any paved, gravel or packed area per definition
above table
10 X 20 = 200
Others X
X = If the total impervious area of the proposed site
X = development is greater than 2000 square feet a
Small Parcel Stormwater Site Plan is Required
Total Impervious Surface Area (sum of all areas) 4072
If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read, acknowledge and sign below.
Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor. I
further acknow dge that the information provided is accurate and employees of Mason County are granted access to the above-
described proTIperrvious
review and inspection as may be required.
X Owne Agent/Contractor(circle one)Date: 11/12/2021
If the Total Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign
the information provided on page 2 of 2.
Page 1 of 2
MASON COUNTY COMMUNITY SERVICES _Permit No:
PERMIT ASSISTANCE CENTER:
.BUILDING•PLANNING•PUBLIC HEALTH•FIRE MARSHAL J"`
615 W.Alder Street,Shelton,WA 98584 t � ['""'� ] n
Phone Shelton:(360)427-9670 ext 352•Fax:(360)427-7798 Phone ��Y I y f�`f.= ` ° -•
Belfair.(360)275-4467•Phone Elma:(360)482-5269
_.1:-' S'li Fri•, .
BUILDING PERMIT APPUdATION
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME:Derek&Aliahna Watts NAME:same as owner
MAILING ADDRESS:Po emk 2W MAILING ADDRESS:
CITY:Belfair STATE:WA ZIP:98528 CITY: STATE: ZIP:
PHONE#1:360-801-"" PHONE: CELL:
PHONE#2:775.822-2197 EMAIL:
EMAIL:allahnamariez@gmafl.com L&I REG# EXP.
PRIMARY CONTACT: OWNER 0 CONTRACTOR❑ OTHER❑
NAME Niahnawatta EMAIL aliahnamarie2fgmall.mrn
MAILING ADDRESS PO Box 26W CITY Betfalr STATE WA ZIp 98528
PHONE 3848e154" CELL 360-s01-5404
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number) 12321-24-MM ZONING R4
LEGAL DESCRIPTION(Abbreviated) Lot 3 of SP#3139 AF#216630 PTN of SE NW FIRE DISTRICT North Mason Rre
SITE ADDRESS 51 NE Garrick Ln. CITY Belfair
DIRECTIONS TO SITE ADDRESS t"3 to Gorst,Left on Log Yard Rd,Left on Katchemak Ln,over rail road tracks take immediate right turn(still
Katchemak Ln),left on Garrick,access to 51 Garrick Ln at bottom of hill on left side
IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES❑ NO❑� SNOW LOAD:_psf
IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (irhea aadwapply):
SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑
TYPE OF WORK: NEW EI ADDITION❑ ALTERATION❑ REPAIR❑ OTHER ❑
USE OF STRUCTURE(Residence,Garage.Commercial Bldg,Etc.)Residence wM attached garage
IS USE: PRIMARY❑+ SEASONAL❑ NUMBER OF BEDROOMS 4 NUMBER OF BATHROOMS 2.5
HEATED STRUCTURE? YES(Whole Bug)❑ YES(Part[s]of Bldg) i❑ NO❑
DESCRIBE WORK New single family dwelling with attached unheated garage
SOUARE FOOTAGE:proposed)
1 ST FLOOR 27Yo sq.& 2ND FLOOR sq.& 3RD FLOOR sq.& BASEMENT sq.&
DECK sq.& COVERED DECK 400 sq.& STORAGE sq.& OTHER sq.ft.
GARAGE 962 sq.& Attached❑+ Detached❑ CARPORT sq.ft Attached❑ Detached❑
MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED*
MAKE MODEL YEAR LENGTH
WIDTH BEDROOMS BATHS SERIAL NUMBER
ENVIRONMENTAL HEALTH:
SEWAGEISEWER SOURCE: SEPTIC❑+ SEWER❑ / NEW[a EXISTING❑
PLUMBING IN STRUCTURE? YES❑+ NO❑ If yes,attach completed Water Adequacy Form
PERIMETERIFOUNDATION DRAINS PROPOSED? YES❑ NOD EXISTING SQ.Fr.
EXISTING BEDROOMS PROPOSED BEDROOMS 4 TOTAL BEDROOMS 4
OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by
signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have
obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal
representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180
days or if construction work is suspended for a period of 180 days.
PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PER41UCATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON
COUNTY CODE 14.08.42)
X 11/12/21
Siriature aFOVIINER(Must be signed by the OWNER) Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT /-3/XZ
PLANNING DEPARTMENT
FIRE MARSHAL
PUBLIC HEALTH
10 MASON COUNTY COMMUNITY SERVICES_ _ Permit No: - 1
PERMIT ASSISTANCE CENTER: r
•BUILDING •PLANNING •FIRE MARSHAL
615 W.Alder St-Shelton, WA 98584 I "� � g
www.co.mason.wa.us NOV4 V I LD I �3
Phone Shelton:(360)427-9670 ext. 352- Fax:(360)427-7.798. V/.
Phone Belfair.-(360)275-4467- Phone Elma:(360)482-5269
PLUMBING & MECHANICAL PERMIT APPLICATION
OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME:Derek&Aliahna Watts NAME:same as owner
MAILING ADDRESS:Po Box 2666 MAILING ADDRESS:
CITY:Belfair STATE:WA ZIP:98528 CITY: STATE: ZIP:
Ist PHONE:36o-aot-54o4 PHONE: CELL:
2°d PHONE:775-622-2197 EMAIL :
EMAIL:aliahnamarie2@gmail.com L&I REG# EXP.
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number):12321-24-90083 Zoning:R4
LEGAL DESCRIPTION(Abbreviated):Lot 3 of SP#3139 AF#216630 PTN of SE NW
SITE ADDRESS:51 NE Garrick Ln.Belfair WA 98528 CITY:Belfair
DIRECTIONS TO SITE ADDRESS:
Hwy 3 to Gorst, Left on Log Yard Rd, Left on Katchemak Ln,over rail road tracks take immediate right turn (still on Katchemak Ln),
left on Garrick Ln,access to 51 NE Garrick at bottom of hill on left side
TYPE OF JOB:
NEW 0✓ ADD=ALT=REPAIR=OTHER USE OF BUILDING residence
LOCATION OF FIXTURES/UNITS—1ST FLOOR✓]2ND FLOOR=BASEMENT=GARAGE=OTHER
PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS
Type of Fixture No.of Fixtures Fees Fuel Type:Electric LPCJ:: Vatural GasE�Ductless0
Toilets 3 27 Type of Unit No.of Units Fees
Bathroom Sink 5 45 Furnace
Bath Tubs 2 18 Heat Pump 1 19
Showers 3 27 Spot Vent Fan 3 30
Water Heater 1 9 Propane Tank
Clothes Washer 1 9 Gas Outlets
Kitchen Sinks 1 9 Wood/Gas/Pellet Stove 1
Dishwasher 1 9 Kitchen Exhaust Hood 1 14
Hose bibs 2 18 Dryer Vent
Other Solar Panel
Other Air Handler-1 14
Base Fee 25 Base Fee 30
TOTAL PLUMBING 178 TOTAL MECHANICAL
OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is
by signature below. I declare that 1 am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this
permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of
interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of
Mason County access to the above described property and structure(s)for review and inspection.This permitlapplication becomes null&void
if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF
OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS
WILL TE THE APPLICATION.
X I LI A 11/12/21
gna re f Owner Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
Rev:1/27/2016 1BN