HomeMy WebLinkAboutBLD2019-00120 SFR with Garage - BLD Permit / Conditions - 4/11/2019 \, Mason County
ff Mason County - Division of Community Development
615 W. Alder St. Bldg. 8
-- Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
BLD2019-00120 NEW SINGLE FAMILY RESIDENCE
PROJECT DESCRIPTION: NEW SFR WITH ATTACHED GARAGE ISSUED: 04/11/2019
SITE ADDRESS: 61 E GARNET CT UNION
EXPIRES: 10/08/2019
PARCEL: 322327590013
APPLICANT: Kimball, Nancy OWNER: MOHLING, JIM &LINDA
81 E Tower LN 81 E TOWER LN
UNION,WA 98592-0585 UNION,WA 98592
360-490-1353
GENERAL CONTRACTOR'S LICENSE: DEWHILL HOMES LLC License: DEWHIHL941JD
1.360.490.1353 Expires: 12/15/2020
VALUATIONS: FEES: Paid Due
R-3 VB Residential, one- 2045.00 $246,933.75 Mechanical Base Fee $30.00 $0.00
and two-family Building Permit Fee $2,257.36 $0.00
U VB Utility, miscellaneous 777.00 $37,140.60 Plumbing Fees $167.00 $0.00
Covered Deck/Carport 242.00 $5,324.00 Mechanical Fees $92.00 $0.00
State Fee-Residential $6.50 $0.00
Plumbing Base Fee $25.00 $0.00
Plan Check Fee $1,467.28 $0.00
Planning Review Fee $240.00 $0.00
Change in Tenant-Minor EH $110.00 $0.00
Plan Review
Total: $289,398.35 Totals : $4,395.14
$0.00
FIXTURES
(Qty Mechanical Fixtures Qty Plumbing Fixtures
1 Dryer Vent(s) 1 Number of Clothes Washers
1 Kitchen Exhaust Hood(s) 1 Number of Dishwashers
1 Number of Kitchen Sinks
1 Number of Water Heaters and or Vent
Printed by:Genie Mcfarland on:04/11/2019 11:34 AM
Page 1 of 7
r
Mason County
Mason County - Division of Community Development
615 W. Alder St. Bldg. 8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCE BLD2019-00120
(Otty Mechanical Fixtures City Plumbing Fixtures
1 For the installation or relocation of each forced-air 2 Number of Hose Bibs
or gravity-type furnace or burner, including ducts 3 Number of Bath Tubs
and vents attached to such appliance, up to and
including 100 Btu/h (29.3 kW) 3 Number of Showers
1 Heat Pump(s) 3 Number of Toilets
3 Spot Vent Fan(s) 4 Bathroom Sink
REQUIRED INSPECTIONS
Setback Inspection Rough- Plumbing Inspection
Footing Inspection Mechanical Inspection
Foundation Wall-Pre-Pour Inspection Insulation Inspection
Shearwall Inspection BLD-Final Inspection
Framing Inspection
CONDITIONS
CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING
DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All
construction must be in conformance with the international codes as amended and adopted by Mason County. Any
corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting
additional inspections.
* The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the
approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule,
minimum 1 hour) will be charged and shall be collected by the Building Department prior to any further inspections being
performed or approvals granted.
* Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer
specifications and in accordance with IRC Section R315.
Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level
of the dwelling.
EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of
fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or
created.
* The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more
than 150' from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards
for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to
another fire apparatus access road which connects to a county maintained public road.
Printed by:Genie Mcfarland on:04/11/2019 11:34 AM
Page 2 of 7
Mason County
Mason County - Division of Community Development
615 W. Alder St. Bldg. 8
--= Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCE BLD2019-00120
* All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or
any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction.
* Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the
structure.
* All building permits shall have a final inspection performed and approved by Mason County Building Department prior to
permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property
records on file with Mason County as being non-compliant with Mason County ordinances and building regulations.
* Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly
corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of
pressure treated material.
* Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and
MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either
private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an
existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance
and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting
from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any
construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that
office to review future planned work which may affect your project.
* Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site
plan. Please check your"Approved Site Plan" to ensure these structures are shown and meet the setback conditions listed.
* All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor
increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way.
* Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a
permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor
& Industries (L&I).
For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415-
4000.
* The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility
of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked
"APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is
responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of approved documents will result in failure of required building inspections.
* REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable
provisions of the current code and the manufacturer's installation instructions.
A drip edge shall be provided at eaves and gables of shingle roofs.
* All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and
plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee
schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections
being performed or approvals granted.
* Adopted IECC/Washington State Energy Code Compliance has been approved as follows:
Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine -4C, Window (Max U-
Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation
R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10.
1a EFFICIENT BUILDING ENVELOPE 1a:
Printed by:Genie Mcfarland on:04/11/2019 11:34 AM
Page 3 of 7
+ Mason County
(� T Mason County - Division of Community Development
615 W. Alder St. Bldg. 8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCE BLD2019-00120
Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U = 0.28
Floor R-38
Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab
or
Compliance based on Section R402.1.4: Reduce the Total UA by 5%. 0.5
3bb HIGH EFFICIENCY HVAC EQUIPMENT 3b:
Air-source heat pump with minimum HSPF of 9.0
1.0
5a EFFICIENT WATER HEATING 5a:
All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 GPM or less. All other lavatory faucets
shall be rated at 1.0 GPM or less.c
0.5
5c
EFFICIENT WATER HEATING 5c:
Water heating system shall include one of the following: Gas, propane or oil water heater with a minimum EF of 0.91
or
Solar water heating supplementing a minimum standard water heater. Solar water
heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the Solar Rating and Certification
Corporation (SRCC) Annual Performance of OG-300
Certified Solar Water Heating Systems
or
Electric heat pump water heater with a minimum EF of 2.0 and meeting the standards of NEEA's Northern Climate
Specifications for Heat Pump Water Heaters
1.5
• The foundation/footing must be placed on undisturbed, firm-native soil.
• Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance
with Mason County Title 14.28 and 14.17.
Printed by Genie Mcfarland on:04/11/2019 11:34 AM
Page 4 of 7
Mason County
Mason County - Division of Community Development
= 615 W. Alder St. Bldg. 8
� Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCE BLD2019-00120
" By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your
"Approved Site Plan" to ensure these structures meet the setback conditions listed.
* A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit
application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the
responsibility of the owner/agent of the developed parcel. It is the owner/agent/con tractor's responsibility to ensure that
Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement
of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater
Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel
Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the
development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other,
parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final
inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater
management system have been installed as approved on the stormwater site plan.
* All property lines shall be clearly identified at the time of foundation inspection.
* All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building
Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration.
Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No
more than one extension may be granted.
* Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries,
Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an
unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either
the homeowner, agent for the owner or a registered contractor according to WA state law.
* A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance
with IECC/WSEC Section R404.1.
* WIND LOADS - Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic
wind speed for Mason County is 85 MPH.
* A permanent certificate, completed by the builder or registered design professional, shall be posted on a wall in the space
where the furnace is located, a utility room, or an approved location inside the building. When located on the elctrical panel,
the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect labek, or toher reqyired
Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab,
basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the
solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate
shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service
water heating equipment, duct leakage rates including test conditions as specified in WSEC Section R401.3 & R402.4.1.2,
and air leakage results if a blower door test was conducted.
Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air
changes per hour when tested with a blower door in accordanve with IECC/.WSEC Section R402.4.1.2.
The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution
panel. Air leakage testing is not required for additions less than 500 square feet. Reference IECC/WSEC R402.4.1.2.
Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2015 Certificate" and are
available in Y4 or sheets. The Mason County Permit Center will also have some available.
Printed by:Genie Mcfarland on:04/11/2019 11:34 AM
Page 5 of 7
INSPECTION CARD
Mason bounty
615 W. Alder St. Bldg. 8, Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
PERMIT# BLD2019-00120 PROJECT ADDRESS 61 E GARNET CT UNION, WA 98592
PARCEL# 322327590013 PROJECT DESCRIPTION NEW SFR WITH ATTACHED GARAGE
OWNER MOHLING, JIM &LINDA ADDRESS 81 E TOWER LN PHONE
CONTRACTOR DEWHILL HOMES LLC ADDRESS 81 E TOWER LN PHONE 1.360.490.1353
CONTRACTOR LICENSE DEWHIHL941JD LENDER
INSPECTION INSP DATE Comments INSPECTION *17
DATE Comments
Setback Inspection (.�,� �� c I j Rough-Plumbing Inspection _j
Footing Inspection Mechanical Inspection
Foundation Wall-Pre-Pour J� // — Insulation Inspection -2/-
Shearwall Inspection BLD-Final Inspection
Framing Inspection -1-/—
UKy\6t(- \ooY- Ot -40A 5 5
(se-
1-16-20 b5c ,fie .���'
r
L
® Mason County
Mason County - Division of Community Development
615 W. Alder St. Bldg. 8
-- Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCE BLD2019-00120
* All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as
adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted
classification. Any non-approved change of use or occupancy would result in permit revocation.
* Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC
R403, applicable sections of the IRC, and IMC.
Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the
purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including
infiltration and ventilation. Design calculations shall be available for inspection during inspection.
Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct
systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other
approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be
marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used
with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-
sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings
shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B
and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm)
and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint.
Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation
instructions.
Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be
insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s) trained to perform such testing. A signed affidavit
documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building
Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website
titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not
required if the air handler and all ducts are located within the heated space.
* On-site Septic System final installation approval required prior to temporary/final occupancy of the residence.
* Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered.
A.) Drainfield/Reserve requires a 1 Oft setback from all footing/foundations.
B.) Septic tank(s) requires 5ft setback from all footing/foundations.
C.) No foundation/ Perimeter Drains within 30ft, down gradient of Drainfield/ Reserve area.
D.) No Cut Bank(s) (greater than 5ft and over 45 degrees)within 50ft, down gradient of Drainfield/Reserve area.
I hereby certify that I have read and examined this application and know the same to be true and correct.
All provisions of Laws and Ordinances governing this type of work will be complied with whether
specified herein or not. The granting of a permit does not presume to give authority to violate or cancel
the provisions of any other state/local law regulating construction or the performance of construction.
Issued By:
Contractor or Authorized Agent. Date: /2/ ///7
Printed by:Genie Mcfarland on:04/11/2019 11:34 AM
Page 6 of 7
Y
MASON COUNTY 360-427-9670 Shelton ext.352
360-275-4467 Belfair ext.352
-482-5269 Elma ext.352
COMMUNITY SERVICES 360
Building,Planning,Environmental Health,Community Health
615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.co.mason.wa.us
CORRECTION/INSPECTION REPORT
PERMIT/CASE NUMBER: &--p Zfl 1 q — 001 Z o
ADDRESS/LOCATION: 1!0! E (fl c✓y.t. + t o %A t o yr
z
NGS:
I IK
a " a 4,44t is rz vec-e1 e -Ny zo Sc +
Z
II-- or CYC best k -4-v5 5
I t t IL C `l + rt 7 +-v-; Ci✓C�
41
S ,- -+ e et C exsS ZT-e155 -111"US14 -10 L
ter.ti e
Items listed above must be corrected to gain compliance.
❑ THIS IS NOT A COMPLETE INSPECTION
❑ This structure has been inspected by Mason County Building Department and the items listed
above are in VIOLATION of Mason County laws and/or ordinances.
❑ Call for re-inspection when corrections are made before proceeding with any further work.
g�K41ake corrections, items will be checked on the `ext inspection.
OK to l!j w� �NS a to*,�X aaa-�-
Date: — - z 0 ❑ Please contact our office regarding possible
Department: [,I> structural damage incurred by recent
Inspector: "natural/man made"disasters.This is NOT a
CORRECTION NOTICE.
DO NOT REMOVE THIS TAG
MCC14.12
A
N N X
-N m toFb O
r
Nc �x
3FE 3 �
� m
D D
!� m z
4
O
IE m
m
z
mm
AE �' D � mg z
cj b Cl W 'u
�.
(P u,
:3 -0 .G A A
U -
�. 0
a-
(D
(D
O
zr
(D Q
CIL
�
o
C D
AR
a �
m
� Z m
Q -A-
(D
N
O
cn
CD
F
C(iD) MASON COUNTY 360-427-9670 Shelton ext.352
COMMUNITY SERVICES 36 60-482-52 Be lm ext.352
360-482-5269 Elma ext.352
Building, Planning, Environmental Health,Community Health
615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.co.mason.wa.us
CORRECTION/INSPECTION REPORT
PERMIT/CASE NUMBER: '&D2-C3l 4? 001 2-0
ADDRESS/LOCATION: 67 A4-1-9Z>� C Y4- 644 j®Llf
FINDINGS:
cp4s2 3 ue ham,
prev
icw..t-5G Ai'avn lLeA4
.4 arree "
2� �Ue iQ coats �o .dam rlyrf
DOA Pr A1
Items listed above must be 4orrected to ain com lia
❑ THIS IS NOT A COMTTE-INSPE-C'I'ION
❑ This structure has been inspected by Mason County Building Department and the items listed
above are in VIOLATION of Mason County laws and/or ordinances.
❑ Call for re-inspection when corrections are made before proceeding with any further work.
❑ Make corrections, items will be checked on the next inspection.
❑ OK to
Date: /''f '��d ❑ Please contact our office regarding possible
Department:_ structural damage incurred by recent
Inspector: "natural/man made"disasters.This is NOT a
CORRECTION NOTICE.
DO NOT REMOVE THIS TAG
MCC14.12
MASON COUNTY 360-427-9670 Shelton ext.352
4
360-275-4467 Belfair ext.352
COMMUNITY SERVICES 360-482-5269 Elma ext.352
Building, Planning,Environmental Health,Community Health
s
615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.co.mason.wa.us
CORRECTION/INSPECTION REPORT
PERMIT/CASE NUMBER: 61 l7 2-D19 — 00 l Z O
ADDRESS/LOCATION: (0 (/- l;-- , LA yi l00
FINDINGS:
5—�— a o�U✓e s 4
Z Co vda,-6. /hL C a 4- ✓A�.✓7 ! C,'
v To° w,� a
Y /its k Cc k--A
r 0- ele < h
lv s5 Z
Items listed above must be corrected to gain compliance.
❑ THIS IS NOT A COMPLETE INSPECTION
❑ This structure has been inspected by Mason County Building Department and the items listed
above are in VIOLATION of Mason County laws and/or ordinances.
❑ Call for re-inspection when corrections are made before proceeding with any further work,
ake corrections, items will be checked on the next inspection.
OK to
Date: (J — 7-0 L� ❑ Please contact our office regarding possible
Department: structural damage incurred by recent
Inspector: "natural/man made"disasters.This is NOT a
CORRECTION NOTICE.
DO NOT REMOVE THIS TAG
MCC14.12
O�oN ,co MASON COUNTY COMMUNITY SERVICES -��A ;1 O� MOO
.. PERMIT ASSISTANCE CENTER; Permit No: ; C7)
•BUILDING•PLANNING•PUBLIC HEALTH•FIRE MARSHAL RECEIVED
615 W.Alder Street,Shelton,WA 98584
-_ Phone Shelton:P60)427-9670 ext. 352•Fax:(36
185 4 � tor� FES 0 8 2019
._ Belfair:(360)275-4467•Phone Elma:(36 2
ING
615 W. Alder Sfreet
BUILDING PERMIT APPLICATION— ,
1
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME:s�f�r odnp 1...(1 n da mn �1 o/!I NAME: 1 V Qt"CUkn, nQA
MAILING ADDRESS: S j —1-0 �Yt MAILING ADD ASS:'%` E '"�0"+,U�;r LO Vl-"
CITY: STATE: W)a ZIP: OK-1 CITY: STATE: VVA ZIP: OJ$5qZ
PHONE#1.--6 OLO--is 51 PHONE: CELL:
PHONE#2: EMAIL : d0w JWJJ I om a 0 hr7t gcl l,4:b al
EMAIL: L&I REG# EXP.
PRIMARY CONTACT: OWNER ❑ CONTRACTORS OTHER❑
NAME • 1 EMAILrr�ei.t)hi f i1�10V►'tr S 1�1,t?I-iYlrzr ► I • �Dr'1
MAILING DDRESS uie- L uvLtl CITY IM'10n STATE WA ZIP W592-
PHONE (5 `�9t� —i 35 3 CELL
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number) 522-3Z 7 Do ZONING
LEGAL DESCRIPTION(Abbreviated) FIRE DISTRICT
SITE ADDRESS (01 E . 01611(Vl?j ('My+ CITY_ UY)1QY1
DIRECTIONS TO SITE ADDRESS Me,RQ VIA R d , ! or) U f.;-0 Y7 'D
h ae ` cIY�tP. �"�t- ✓gin -i<.�r� c�v1 l�-F —
IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NO ❑
IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply):
SALTWATER❑ LAKE ❑ RIVER/CREEK ❑ POND ❑ WETLAND ❑ SEASONAL RUNOFF ❑ STREAM ❑
TYPE OF WORK: NEW' ADDITION❑ ALTERATION ❑ REPAIR❑ OTHER ❑
USE OF STRUCTURE (Residence,Garage,Commercial Bldg,Etc) iZe1C�C '�
IS USE: PRIMARY* SEASONAL ❑ NUMBER OF BEDROOMS_ NUMBER OF BATHROOMS��
HEATED STRUCTURE? YES (Whole Bldg) YES (Part[s]of Bldg) ❑ NO ❑
DESCRIBE WORK
SQUARE FOOTAGE: (propose+existing)
IST FLOOR 7DA15 sq. ft. 2ND FLOOR sq. ft. 3RD FLOOR sq.ft. BASEMENT `—. sq. ft.
DECK n)G- sq. ft. COVERED DECK Z,{2 sq. ft. STORAGE sq. ft OTHER sq. ft.
GARAGE 17-1 sq. ft. Attached ly Detached❑ CARPORT i sq.ft. Attached❑ Detached❑
MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED*
MAKE MODEL YEAR LENGTH
WIDTH BEDROOMS BATHS SERIAL NUMBER
ENVIRONMENTAL HEALTH:
SEWAGE/SEWER SOURCE: SEPTIC ( SEWER❑ / NEW [ EXISTING ❑
PLUMBING IN STRUCTURE? YES V NO ❑ If yes, attach completed Water Adequacy Form
PERIMETER/FOUNDATION DRAINS PROPOSED? YES ❑ NOV EXISTING SQ.FT.
EXISTING BEDROOMS PROPOSED BEDROOMS TOTAL BEDROOMS
OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by
signature below. I declare that I am the owner and I further declare that 1 am entitled to receive this permit and to do the work as proposed. I have
obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal
representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180
days or if construction work is suspended for a period of 180 days.
PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED. (MASON
COUNTY CODE 14.08.42)
Signature of OWNER(Must be signed by the OWNER) Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
PUBLIC HEALTH
MASON COUNTY
COMMUNITY SERVICES
Building,Planning,Environmental Health,Community Health BUILD
I
G
Physical and Mailing Address: 615 W Alder St.,Bldg 8, Shelton, WA 98584
Shelton Phone: (360)427-9670 ext 352 ❖ Fax (360)427-7798
PLUMBING & MECHANICAL PERMIT APPLICATION Permit#:
OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME: J' n Cv LiyidC I�Aphbnq� NAME: Q". - \1C\YnbA.��
MAILING ADDRESS: 5C1 -E _rOiuDY /h J MAILING ADDRESS: l F _T0W W WyW
CITY: I-Ay klm ) STATE: V�h ZIP:��,� CITY: .0 STATE: WA ZIP: qrs_
ist PHONE: PHONE: Li 9D-_1'35.3 CELL:
2nd PHONE: EMAIL: &W3!14(i bVYWN (0i0 140-i'I,i1)a,j I - 02 1,n
EMAIL: L&I REG# EXP.
PARCEL INFORMATION:
PARCEL NUMBER (12 Digit Number): , ZZ 3 2-7 5 qC/G 13 Zoning:
LEGAL DESCRIPTION (Abbreviated:
SITE ADDRESS:yam l&YV1b (.blot\i.t CITY: 1AV11pn
DIRECTIONS TO SITE ADDRESS: K: 'P 1 0' tS'
r a vi h-�- (A- Y D ev U n �-�-
TYPE OF JOB/WORK: NEW )C ADD ALT REPAIR OTHER
USE OF BUILDING-PP.(rs r) 0-1 US I d?'ne,2.�
PLUMBING FIXTURES MECHANICAL UNITS [] Electric in-wall heaters(no fee)
Type of Fixture No. of Fixtures Fuel Type Fees Type of Unit No. of Units Fuel Type Fees
Toilet(s) �� Furnace I G/LPG]
Bathroom Sink(s) Heat Pump 15G/LPG]
Bath Tub(s) o Ductless H.P. [E/G/LPG]
Shower(s) Spot Vent Fan _
Water Heater(s) a* G/LPG] Propane Tank ga[.]
Clothes Washer(s) I E /LPG] Gas Outlet(s) ----
Kitchen Sink(s) I Heat Stove - [E/G/LPG/W]
Dishwasher(s) I Kitchen Exhaust Hood �—
Hose bib(s) 2 Dryer Vent 1
Other Solar Panel
Other Other
Plumbing Subtotal Mechanical Subtotal
Plumbing Base Fee Mechanical Base Fee
Final Inspection Fee Final Inspection Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is
by signature below. I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this permit and to
do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this
project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above
described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not
commenced within 180 days or if construction work is suspended for a period of 180 days.PROOF OF CONTINUATION OF WORK IS BY MEANS OF
INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
X i �Vt�" ip i 16-71 i q
Signa re of.Applicant Date
X A/�v 1 W (M Owner/Owners Re resentati a/Contracto
Prinf-0 ame (Circle one)
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
O Building 1> C 3.2Z1I
O Fire Marshal
O Permit Tech (OTC permit only)
i�ii U-4 O;l-II;i:' I1Ti:[a://W",tIV.CO.ME:SOl,.wa.us/comn-lunity_dev/ Rev:3/08,2017
n ! 6 f
tw
7-7• �iM''1f'�il'�G�l� 1�IaYllfj'}�
-' NG
All
Q� RECEIVED
a
^� v FEB 0 8 2019
615 W. Alder Street
S'
.
00 2,p
4
tsc
40'
55���� �
� acubck
bo� 0, 1.0, 3a
�'��" ------- A T E 5 T HOLE LO C A ri o N
o' No A-Z, t-AS I. M c rd
PLANNING:
sb�'� '" ALL SETBACKS4ARE MEASURED
FROM THE FURTHEST
—
P"0 "T"Ti 1 ►BUILDING
W r�c2: NON PROPERTIAPPROVED
YvIASON COUNTY DCD PLANNING
SITE PLAN J REQUIRED TO BE ON SITE
CHANGES SUI93ECT TO APP� �I. ;�j
By /d v` Date_____P� -
Name N�Gi�11n Parcel# 3Z237--1c,-A0Q ,3 BLD#�. 11
Mason County ���B
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 2 of 2)
Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity.
Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater
Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website:
http//www.co.mason.wa—us/code/commissioners/index.htm
Please follow the links to "Title 14,Chapter 14.48 Stormwater Management".
Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan
(Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document
entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist
you in preparing the necessary information and plans for Public Works to review and approve. Per Department of
Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in
their entirety AND no part of the stormwater system adversely affects any septic system (see Environmental Health
information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval.
A design by a registered professional may be required for more complex sites.
*These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan
on the pages that begin with"Handout"
PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE
A)--)(—The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed
in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel.
B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the
system will be located as not to adversely affect any septic systems on this,or any other,parcel.
If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works
Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at:
Phone: 360-427-9670 ext 450
100 W. Public Works Dr
Shelton.WA 98584
If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or
any other,parcel.You may also wish to consult with the septic design professional involved with the project. Mason
County Division of Environmental Health can be reached at:
Phone: 360-427-9670 ext 400
415 N. 6th St—Bldg#8 lower level
Shelton.WA 98584
A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met
prior to a request for final inspection of the building permit.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required.X Owner/Agen Contrac �1(circle one)Date: 1 o
Page 2 of 2
I
Name Moh I i Parcel# / 3,7-7 5 2 J 01, S BLD#
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 1 of 2)
Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is
made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface'.
'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development
including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not
part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment.
'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas,
concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the
natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces.
To Calculate Impervious Surfaces Please Complete This Table
Surface Type Length X Width = Area *All dimensions in feet
r
Buildings , 5 X ?�o = 2l7 ,�
'7 S X . _ —� Measurements for buildings are taken at the
perimeter of the farthest projections(example:
X = eaves/gutters)
X =
Driveways X =
X = Length of drive begins at the right of way
X =
Parking Areas X =
X = Any paved, gravel or packed area per definition
above table
X =
Patios/Walks � X =
X = Any paved, gravel or packed area per definition
above table
X =
Others X =
X = If the total impervious area of the proposed site
X = development is greater than 2000 square feet a
Small Parcel Stormwater Site Plan is Required
Total Impervious Surface Area(sum of all areas)
If the Total Impervious Surface Area is LESS THAN 2000 Square Feet, please read,acknowledge and sign below.
Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required.
X 46 Owner/Agen ontrac r(circle one)Date: (✓ J 7//
If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read, acknowledge and sign
the information provided on page 2 of 2.
Page 1 of 2
1
Simple Heating System Size: Washington State a
This heatinQ system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Ener and ACCA
Manuals J and S.This calculator will calculate heating loads only,ACCA orocedures for sizing cooling systems should be AftitterEft"linci
loads. ft 116.0 t
NG
Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,
some values will be calculated for you.If you do not see the selection you need in the drop-down options,please tall the WSU Energy Extension
Program at(360)956-2042 for assistance.
Project information Contact Information
Mohling,Jim&Linda Dewhill Homes LLC
61 E Garnet 81 E Tower Ln
Union,WA 98592 Union WA 98592
Heating System Type: 0All other systems •Heat Pump
To see detailed instructions for each section,place your cursor on the word"Instructions".
Design Temperature
Instructions '" Design Temperature Difference(AT) 47
Shelton AT=Indoor(70 degrees)-Outdoor Design Temp
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area(sq ft) 2,045
Average Ceiling Height Conditioned Volume
Instructions Average Ceiling Height(ft) 9.01 18,405
Glazing and Doors U-Factor X Area = UA
Instructions
U-0.26 0.280 240 67.20
Skylights U-Factor X Area = UA
Instructions 0.50 00
Insulation
Attic U-Factor X Area = UA
Instructions R-49 0.026 1,515 39.39
Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA
Instructions R-38 Vented . 0.027 F 760 20.52
Above Grade Walls(see Figure 1) U-Factor X Area UA
Instructions 0.056 1,628 91.17
R-21Intermediate -
Floors U-Factor X Area UA
Instructions 0.025 2,045 51.13
R-38
Below Grade Walls(see Figure 1) U-Factor X Area UA
Instructions
No Below Grade Walls in this project. 0.028
Slab Below Grade(see Fiapre a F-Factor X Length UA
Instructions No Slab Below Grade in this project. A 0.303
0
Slab on Grade(see Ffraure•) F-Factor X rLength UA
Instructions No Slab on Grade in this project.
Location of Ducts
Instructions Duct Leakage Coefficient
Unconditioned Spa u !
����� 1.10
Sum of UA 269.40
Envelope Heat Load 12,662 Btu/Hour
Figure 1. Sum ofUAXAT
Air Leakage Heat Load 9,342 Btu I Hour
VolumeX 0.6XATX.018
Above Grade Building Design Heat Load 22,004 Btu/Hour
Air Leakage+Envelope Heat Loss
Building and Duct Heat Load 24,205 Btu/Hour
Ducts in unconditioned space:Sum of Building Heat Loss X 1,10
Duds in conditioned space:Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 30,256 Btu I Hour
Building and Duct Heat Loss X 1.40 for Forced Air Furnace
Building and Duct Heat Loss X 1.25 for Heat Pump
(07/OV13)
f
s
MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT
WSEC/ Ventilation Code Compliance Application
Submit with heating/cooling system size worksheet (see instructions #4)
Owpofer: Parcel#: Type project:
im a HOW 32 2 Z 75 9 0013 i�ew i
Total Sq. Ft. I Floor: 2"d floor. Heated Basement:
of heated area:: C)LA� 5L
H sting System Type: 0 Electric wall heater O Electric Central Furnace O LPG Furnace
Heat Pump with electric furnace 0 Heat pump with gas furnace 0 Ductless Heat Pump
0 Boiler, specify fuel type: O Other.
Specify:
Prescriptive Option Table R402.1.1 (see table on previous page)
Compliance
Method ❑ Component Performance, R402.1.3 — Calculation worksheets required
Must Check one:: ❑ Other (specify):
Check one one ❑ Whole House Ventilation system Whole House Ventilation
Ventck us in [Ig exhaust fans &window or wall Integrated with a Forced Air Other, describe:
fresh air vents (M1507.3.4). If using System (M1507.3.5)
n System window vents be sure to order
windows with vents.
Referencing Table R406.2, 'Additional Residential Energy Efficiency Requirements," all residential units
must develop credits as specified in Table 4062. Identify and describe which option(s) will be used to
comply. If the table is not attached to this form you can access the table on our website at:
htto illwww.co.mason.wa.us/forms/Community Dev/iecc wsec.odf
Additional a) Description: Small dwelling units: less than 1,500 sq. feet of heated or cooled floor
area and less than 300 sq. ft fenestration area (skylights, doors, windows, etc).
Energy *Including additions to existing building that are greater than 5D0 sq. ft. of heated floor
Efficiency Req u i rem but less than 1500 sq ft of floor area. Requires 1.5 credits
ents D�large
Medium dwelling units that are not included in (a) above {small dwelling}, OR (c) below
I in Requires 3.5 credits
dwe iEnergy 9} q
credits
qEXCEPTION: Dwelling units serving R-2 occupancies shall require. Requires 2.5
quire • credits. See page two for description.
3e 5 c) Large dwelling unit is a dwelling unit that exceeds 5,000 sq. ft. of heated or cooled
floor area. Requires 4.5 credits
d) Additions less than 500 sq feet. Requires .5 credits
(Fenestration is defined in the IECC as skylights, roof windows, vertical windows, opaque
doors, lazed-doors that include products with glass and non-glass glazing materials.
Describe Energy Credit Option(s):
Using Option
number(s):
5
3
I
.ti
(2015 WSEC- Table 406.2)
OP-ION DESCRIPTION CRED T(S)
l a EFFICIENT BUILDING ENVELOPE la: 0.
Prescriptive compliance is based on Table R402.1.1 with the following modifications:
Vertical fenestration U =0.28
Floor R-38
Slab on grade R-10 perimeter and under entire slab
Below grade slab R-10 perimeter and under entire slab
or
Compliance based on Section R402.1.4: Reduce the Total UA by 5°/a
lb EFFICIENT BUILDING ENVELOPE lb: 1.0
Prescriptive compliance is based on Table R402.1.1 with the following modifications:
Vertical fenestration U =0.25
Wall R-21 plus R-4
Floor R-38
Basement wall R-21 int plus R-5 ci
Slab on grade R-10 perimeter and under entire slab
Below grade slab R-10 perimeter and under entire slab
or
Compliance based on Section R402.1.4: Reduce the Total UA by 15°/a
1 c EFFICIENT BUILDING ENVELOPE 1 c: 2.0
Prescriptive compliance is based on Table R402.1.1 with the following modifications:
Vertical fenestration U =0.22
Ceiling and single-rafter or joist-vaulted R-49 advanced
Wood frame wall R-21 int plus R-12 ci
Floor R-38
Basement wall R-21 int plus R-12 ci
Slab on grade R-10 perimeter and under entire slab
Below grade slab R-10 perimeter and under entire slab
or
Compliance based on Section R402.1.4: Reduce the Total UA by 30°/a.
1 dE EFFICIENT BUILDING ENVELOPE 1 d: 0.5
Prescriptive compliance is based on Table R402.1.1 with the following modifications:
Vertical fenestration U=0.24
2a AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2a 0.5
Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per
hour maximum
and
All whole house ventilation requirements as determined by Section M15073 of the
International Residential Code shall be met with a high efficiency fan(maximum 0.35
watts/cf n�not interlocked with the furnace fan.Ventilation systems using a fiunace
including an ECM motor are allowed,provided that they are controlled to operate at
low speed in ventilation only mode.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the maximum,tested building air leakage and shall
show the qualifying ventilation system
2b AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2b: 1.0
Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 2.0 air
changes per hour maximum
and
All whole house ventilation requirements as determined by Section M1507.3 of the
International Residential Code shall be met with a heat recovery ventilation system
with minimum sensible heat recovery efficiency of 0.70.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the maximum tested building air leakage and shall
show the heat recovery ventilation sysum.
5
'I)P71ON DESCRIPTION I CRED'7(S)
1 r 2c AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2c: 1.5
Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 1.5 air
changes per hour maximum
and
All whole house ventilation requirements as determined by Section M1507.3 of the
International Residential Code shall be met with a heat recovery ventilation system
with minimum sensible heat recovery efficiency of 0.85.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the maximum tested building air leakage and shall
show the heat recovery ventilation system.
3a HIGH EFFICIENCY HVAC EQUIPMENT 3a: 1.0
Gas,propane or oil-fired furnace with minimum ARM of 940/,or
Gas,propane or oiled-fired boiler with minimum AFUE of 92%
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the heating equipment type and the min;mum
equipment efficiency.
3b HIGH EFFICIENCY HVAC EQUIPMENT 3b: 1.0
Air-source heat pump with minimum HSPF of 9.0
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the beating equipment type and the minimum
equipwent efficiency,
3? HIGH EFFICIENCY HVAC EQUIPMENT 3c: 1.5
Closed-loop ground source heat pump;with a minimum COP of 3.3
or
Open loop water source beat pump with a maximum pumping hydraulic head of 150
feet and minimum COP of 3.6
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the heating equipment type and the minimum
ui ment efficiency.
3d HIGH EFFICIENCY HVAC EQUIPMENT 3d: 1.0
Ductless Split System Heat Pumps,Zonal Control:In homes where the primary space
heating system is zonal electric beating,a ductless heat pump system shall be installed
and provide heating to the largest zone of the housing unit
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the heating equipment type and the minimum
equipment efficiency,
4 HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM 1.0
All heating and cooling system components installed inside the conditioned space.
This includes all equipment and distribution system components such as forced air
ducts,hydronic piping,hydronic floor heating loop,convectors and radiators.All
combustion equipment shall be direct vent or sealed combustion.
For forced air ducts:A maximum of 10 linear feet of return ducts and 5 linear feet of
supply ducts may be located outside the conditioned space.All metallic ducts located
outside the conditioned space must have both transverse and longitudinal joints sealed
with mastic.If flex ducts are used,they cannot contain splices.Flex duct connections
must be made with nylon straps and installed using a plastic strapping tensioning tool.
Ducts located outside the conditioned space must be insulated to a minimum of R-8.
Locating system components in conditioned crawl spaces is not permitted under this
option.
Electric resistance heat and ductless heat pumps are not permitted under this option.
Direct combustion heating equipment with AFUE less than 80%is not permitted
under this option.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the heating equipment type and shall show the
location of the beating and cooling equipment and all the ductwork
6
CREDiT S
FTI N DESCRIPTION ( )
O O
5a EFFICIENT WATER HEATING 5a:
All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75
GPM or less.All other lavatory faucets shall be rated at 1.0 GPM or less.`
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the maximum flow rates for all showerheads,kitchen
sink faucets,and other lavatory faucets.
5b EFFICIENT WATER HEATING 5b: 1.0
Water heating system shall include one of the following-
Gas,propane or oil water heater with a minimum EF of 0.74
or
Water beater heated by ground source heat pump meeting the requirements of Option
3c.
or
For R-2 occupancy,a central heat pump water heater with an EF greater than 2.0 that
would supply DHW to all the units through a central water loop insulated with R-8
minimum pipe insulation.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the waxer heater equipment type and the minimum
equipment efficiency.
Sc EFFICIENT WATER HEATING 5c: 1.5
Water heating system shall include one of the following-
Gas,propane or oil water heater with a minimum EF of 0.91
or
Solar water heating supplementing a minimum standard water beater. Solar water
heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the
Solar Rating and Certification Corporation(SRCC)Annual Performance of OG-300
Certified Solar Water Heating Systems
or
El c heat Dump water heater with a minimum EF of 2.0 and meeting the standards
ofNEEA`s Northern Climate Specifications for Heat Pump Water Heaters
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the water heater equipment type and the minimum
equipment efficiency and,for solar water beating systems,the calculation of the
minimum energy savings.
5d EFFICIENT WATER HEATING 5d: 0.5
A drain water heat recovery unit(s)shall be installed,which captures waste water heat
from all the showers,and has a minimum efficiency of 40%if installed for equal flow
or a minimum efficiency of 52%if installed for unequal flow. Such units shall be
rated in accordance CSA B55.1 and be so labeled.
To qualify to claim this credit,the building permit drawings shall include a plumbing
diagram that specified the drain waxer heat recovery units and the plumbing layout
needed to install it and labels or other documentation shall be provided that
demonstrates that the unit complies with the standard.
6 RENEWABLE ELECTRIC ENERGY: 0.5
For each 1200 kWh of electrical generation per each housing unit provided annually
by on-site wind or solar equipment a 0.5 credit shall be allowed,up to 3 credits.
Generation shall be calculated as follows:
For solar electric systems,the design shall be demonstrated to meet this requirement
using the National Renewable Energy Laboratory calculator PVWATTs.
Documentation noting solar access shall be included on the plans.
For wind generation pmjects designs shall document annual power generation based
on the following factors:The wind turbine power curve;average annual wind speed at
the site;frequency distribution of the wind speed at the site and height of the tower.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall show the photovoltaic or wind turbine equipment type,
Provide documentation of solar and wind access,and include a calculation of the
minimum annual energy power production.
a.Projects using this option may not use Option la,lb or lc
b.Projects may only include credit from one space heating option,3a,3b,3c or 3d.PI'ben a housing unit has two pieces of
equipment(i e,two furnaces)both must meet the standard to receive the credit
c Plumbing Futures Flow Ratings.Low flow plumbing ft tnres(water closets and urinals)and fittings(faucets and
showerbeads)shall comply with the following requirements:
1.Residential bathroom lavatory sink faucets:Maximum flow rate-3.81Jmin(1.0 gal/min)when tested in accordance
with ASME A112.18.VCSA B125.1.
2.Residential kitchen faucets:Maximum now rate-6.6 L/min(1.75 gal/min)when tested in accordance with.ASME A112.1&1/CSA B125.1.
3.Residential sbowerbead.s:Maximum flow rate-6.6 L/min(1.75 gal/min)when tested in accordance with ASME A1121&LCSA B12.s.1
7