Loading...
HomeMy WebLinkAboutSWG2022-00378 - SWG Application / Design - 6/28/2022 DESIGN FORM—PAGE ONE Assessor's Parcel Num •r: 3 2 1 0 4 — 5 4 — 0 0 0 5 0 A design will be reviewed when 3 copies of each of the following are submitted: "Completed design form that has been signed and dated. "Scaled layout sketch, inclus mg ••. ':.. • ' -' -- "Scaled plot plan.including all applicable items on checklist. "Cross-section sketch.including all applicable items on checklist. This form may be scanned and available for public view on the Mason County Web site. Maximum paper size: 11• .0/ . PARCELIDENTIFICATION :... .. Permit Number: SWG )1:>'r7- .,00 31% Designer's Name: Arrow Septic Designs, Inc AB Fine Homes Desi er's Phone dumber: (360)898-2255 Applicant's Name: $n Mailing Address: 871E Beach Dr Designer's Address: 171E Vuecrest Dr Union, WA 98592 Union, WA 98592 City State Zip City State Zip . DESI N PARAMETERS . Treatment Device ❑Glendon Biofilter 0 Sand Filter 0 Mound 0 Sand Lined Drainfield 0 Recirculating Filter.Type: ❑Aerobic Unit Make/Model 0 Disinfection Unit Makc/Model Other: Drainfield Type ❑Gravity li Pressure Cif Trench 0 Bed ❑ Sub Surface Drip Septic Tank/Drainfield Specifications . Laterals Number of Bedrooms 3 Schedule/Class 40 Daily Flow: Operating Capacity 270 gpd Length 50 ft Daily Flow: Design Flow 360 gpd Diameter 1.25 in Septic Tank Capacity(working) 1,200 gal Number 3 Receiving Soil Type(1-6) 3 Separation 4.5 min ft Receiving Soil Appl. Rate 0.8 gpd/ft` Orifices Required Primary Area 450 ft` Total Number of Orifices 30 Designed Primary Area 450 ft2 Diameter 3/16 in Designed Reserve Area 450 ft2 Spacing 60 in Trench/Bed Width 3 ft Manifold Trench/Bed Length 150 ft Schedule/Class 40 Elevation Measurements Length header ft Original Drainfield Area Slope 12 % Diameter 1.25 in New Slope. If Altered 12 quo Preferred manifold configuration used? Id Yes ❑ No Depth of Excavation Up-slope 11 in Transport Pipe from Original Grade Dols„-slope Schedule/Class 40 Designed Vertical Separation 24+ in Length 30 ft Gravelless Chambers Required? 0 Yes 0 No 17fOptional Diameter 2 in Pump Required? le Yes 0 No Dosing and Pump Chamber Pump/Siphon Specifications Number of dosesiday 4 OUT. iu Elevation Between Pump& L.ppcnoost Orifice 5 ft DUSC yunutity 90 gal Drainfield Squirt Height: Selected Residual(head) 2 ft Chamber Capacity (flood) 1,000 gal Uppermost Orifice gHigher 0 Lower than Pump Shutoff Pump controls: Please check those required. Capacity(i?Total Pressure Head 17.70 gpm Eti Timer litElapse Meter a'Event Counter Calculated Total Pressure Head 8.12 ft If Timer: Pump on 2.5 min .Pump off 6 hr Comments AP P ROV ED f36 1 .4 7 (Aso?r.ouscre ENVlFiONt4 1YC