Loading...
HomeMy WebLinkAboutBLD2022-00320 Final Solar - BLD Inspections - 5/16/2022 INSPECTION CARD J j Mason County 615 W. Alder St. Bldg. 8, Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us PERMIT# BLD2022-00320 PROJECT ADDRESS 261 E Capital Peak Dr Shelton, WA 98584 PARCEL# 321307500050 PROJECT DESCRIPTION 6.08 kW Solar Array OWNER SANTY BRUCE W ETUX ADDRESS LESLIE COULTER PHONE CONTRACTOR SOUTH SOUND SOLAR INC ADDRESS 4511 LEMON RD NE PHONE 360.352.7869 CONTRACTOR LICENSE SOUTHSS902N7 LENDER INSPECTION I INSP DATE Comments INSPECTION INSP I DATE Comments Mechanical/Plumbing Final ' '' `yam- � SILFAB ELITESILFAB • � • S O L A R tai hl; p NOT JUST ANOTHER SOLAR PANEL . irittroducing Siffab Elite. The highest efficiency solar panel (up to 21.4%) manufactured exclusively in the United States. SILFABSOLAR.00M/SILFABELITE tttt t . q')V 1 t"6 M rELlttil3Clfer ELECTRICAL SPECIFICATIONS 370 375 ` 380 Test Conditions STC NOCT STC NOCT STC NOCT Module Power(Pmax) Wp i 277.78 375 282.05 380 284.6 Maximum power voltage(Vpmax) V 38.34 35.90 38.61 36.15 38.88 36.41 Maximum power current(Ipmax) A 9.69 7.74 9.77 7.80 9.79 7.82 Open circuit voltage(Voc) V 44.76 42.01 44.94 42.18 45.13 42.36 Short circuit current(Isc) A.... 10.33 8.32 10.41 8.39 10.50 8.46 Module efficiency % 20.8 19.5 21.1 19.8 21.4 20.0 Maximum system voltage(VDC) V 1000 Series fuse rating A.. 20.. Power Tolerance Wp 0to+10 Measurement conditions:STC 1000 W/m2•AM 1.5•Temperature 25°C•NOCT 800 W/m'•AM 1.5•Measurement uncertainty<_3% Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by 25%and power by 0 to+10W. MECHANICAL PROPERTIES]COMPONENTS METRIC IMPERIAL Module weight 19.0t0.2 kg 41.9t0.4lbs Dimensions(H x L x D) 1795 mm x 990 mm x 38 mm 70.67 in x 39.98 in x 1.5 in Maximum surface load(wind/snow)' 4000 Pa rear load/5400 Pa front load 83.5/112.8lb/ft^2 Hail impact resistance o 25 mm at 83 km/h e 1 in at 51.6 mph Cells 66 high efficiency back contact 66 high efficiency back contact mono-PERC c-Si cells mono-PERC c-Si cells Glass 3.2 mm high transmittance,tempered, 0.126 in high transmittance,tempered, OSM anti-reflective coating DSM anti-reflective coating Cables and connectors(refer to installation manual) 1200 mm o 5.7 mm,MC4 from Staubli 47.24 in,a 0.22 in,MC4 from Staubli Backsheet Multilayer,integrated insulation film and electrically conductive backsheet,superior hydrolysis and UV resistance,fluorine- free PV backsheet Frame Anodized Aluminum(Black) Bypass diodes 3 diodes-30SQ045T(45V max DC blocking voltage,30A max forward rectified current) Junction Box UL 3730 Certified,IP67 rated TEMPERATURE RATINGS WAR=S ' Temperature Coefficient Isc +0.046%/°C Module product workmanship warranty 25 years" Temperature Coefficient Voc 0.279%rC Linear power performance guarantee 30years Temperature Coefficient Pmax -0.377%/°C >_97.1%end 1st yyr >_91.6%end 12th yr NOCT(t 2°C) 43.5°C >_85.1%end 25th yr Operating temperature -40/+85"C >_82.6%end 30thyr q CERTIFICATIONS SHIPPING SPECS ULC ORD C1703,UL1703,CEC listed-,UL 61215-1/-1-1/-2,UL 61730-1/-2, Modules Per Pallet: 26 or 26(California) Product IEC 61215-1/-1-1/-2".IEC 61730-1/-2-,CSA C22.2#61730-1/-2,IEC 62716 Ammonia -- - -- -- - ---- Corrosion;IEC61701:2011 Salt Mist Corrosion Certifed,UL Fire Rating:Type 1 Pallets Per Truck 34 or 32(California) Factory IS09001:2015 Modules Per Truck 884 or 832(California) A Warning.Read the Safety and Installation Manual for mounting specifications and before handling,installing and operating modules. 12 year extendable to 25 years subject to registration and conditions outlined under"Warranty"at silfabsolar.com "' Certification anticipated January 2021. UJ 1 SILFAB SOLAR INC. to If 3 200mm[7.8r] 800 Cornwall Ave Bellingham WA 98225 USA T +1360.569.4733 info@silfabsolar.com SILFABS0LAR.00M LU o 0 240 Courtneypark Drive East _ LL o 0 ^ Mississauga ON 1_5T 2Y3 Canada E ` a E 122mm 4.80" T +1905.255.2501 3 a, b �',, F +1905.696.0267 > r M 3 Y E , W U E 26mm[1.02"1 I I Silfab-SIL-370/375/380-BK-20201020 �4 - - No reproduction of any kind is allowed.Data and information is subject to modifications without notice.©Silfab 2020. Cable Length 1200mm[47.24"] H PAN files generated from 3rd party performance data are available for download at:silfabsolar.com/downloads 60mm[2.36"1 ,i 447.5mm[17,12"] 900mm[35,43"] r 447.5mm[17.62"1 , 1795mm 70.67" FORTRESS POWER w. eVault Max 18.5 Lithium Battery Storage FORTRESS qV4" L— POWER ,e e,a, The newest innovative Lithium Iron Phosphate battery from Fortress Power is the eVault Max 18.5 kWh.An all-in-one solution for your residential and commercial needs.Scalable up to 370kWh with a serviceable top cover access to make installation of this battery simple and worry free. The eVault Max is AC/DC coupled to solar arrays and works for many applications that require solar storage,including Off-Grid,Back Up Power,Self-Supply,Peak Charge Reduction,and Demand Response,just to name a few. We Provide You The Largest Single Residential Battery On The Market With Easy Installation! Safe Lithium Iron Phosphate Technology(LiFePO4) Intelligent Digital Processor Based Battery Management System High Durability and Long-Lasting (BMS) Closed Loop Communication with Inverters Advanced cell level monitoring and balancing Scalable from 18.5 kWh-370 kWh IP55 Aluminum Industrial Grade Enclosure Touch screen LCD performance display Nominal Voltage 51.2V Dimensions:(L*W*H) 20.3"x 20.3"x 42.2" Nominal Capacity 360AH (515 x 515 x 1073mm) Rated Capacity @ 0.5C(180A) 18.43 kWh Weight 520 tbs(235.87 kg) Resistance <10 mD Terminal Type M10 Communication Protocol CAN/RS485 Ring Terminal Size 1/2"or larger Efficiency(at 0.5C) 98% Terminal Torque 7.0-7.7 Nm(5.1-5.7 ft-lb) Self-Discharge <1%/Month Case Materiat Industrial Grade Aluminum Maximum Allowed Modules in Paratlet 20(370 kWh) Enclosure Protection IP55 Depth of Discharge Up to 100% Celt Type Chemistry Tier 1 Automotive Prismatic-LiFePO4 BreakerHigh Cureent Warranty 10 Years Cycle Life 8,000(@ 80%DoD) �" 1 Certifications UL1642,UL1973,UL9540,UL9540A,CEC,SGIP Shipping Recommended Charge Current 150A Classification UN 38.3.UN 3480,Ctass 9 Maximum Charge Current 180A Recommended Charge Voltage 54.4V BMS Charge Voltage Disconnect >56V Bulk+Absorb Charge 54.4V Absorb Time 60 Minutes • _ 4 � 1 Float Charge 54V Recommended Continuous Discharge Rate 180A(9.2 KW) Inverter Charging 2 Stage/No Float Peak Discharge Rate 230A(12 KW 30 min) Equalization No equalization(typical) Maximum Surge Power Rate 250A(12.8 kW 5 sec) 54.6V for 10 seconds(rare) Recommended Low Voltage Disconnect 48V Temperature Compensation None Battery Low Voltage Protection <46V Battery Recovery Voltage 47V TI/ nt�tel Discharge Temperature -4'F-140'F(-20'C-60°C) c E 1 Y us �� ���8.� Charge Temperature 32'F-120'F(0°C-49*C) PASSED Storage Temperature 6 months:14'F-77'F(-10°C--25'C) 3 months:-4'F-�113'F(-20°C-45°C) Intenek oo,,,....xnwa.�n.�.m.,�."..ryd�.o • ' • • Sales@FortressPower.com .' 505 • Road, Southampton, 'A 18966, ABOUT FORTRESS POWER ip� Fortress Power proudly services homes,businesses,utilities,telecom and transportation companies worldwide. Our Pennsylvania-based team's pas- sion for clean energy storage has earned us a place among the world's top energy storage battery manufacturers. Our logistics centers located across the country offer easy distribution to all of our major markets.Fortress Power's high-performance solar lithium batter storage products are designed, engineered and inventoried alon Y P pP 9 9 with live technna ical support in the United States. Fortress Power has partnered with industry leading lending institutions to help make your solar investment as easy as possible. Ptease visit our website for purchasing and financing options. www.fortresspower.com ��- o E � E :0 9 SCAN ME FOR THE LATEST oe INSTALLATION MANUAL: ® v �• ❑ _ 19 zo.s^ e • 515mm ry M r M w back view o o OO ®U , I side view SCAN ME SCAN ME LATEST BECOMING AN "q FORTRESSINVERTER AUTHORIZED LIUPOWER INTEGRATION r DEALER? Secure your energy MANUAL www.FortressPower.com : - gpa�y'' .. MW ' i- a s 56 ME M 0 }:a�143 _.�'r, flu _ Kam 3 _ a m... _..., .. Battery(optional) Output Power 9000W ® Type Lead-Acid or Li-Ion oNominal DC Input 48V Capacity 50—990OAh ;cad-nr3c Voltage Range 43.0—63.OV SoL-Ark 12K-P Q Continuous Battery Charging Output 185A Charging Curve 3-Stage w/Equalization Spec Sheet Grid to Batt Charging Efficiency 96.0% 1 External Temperature Sensor Included Current Shunt for Accurate%SOC Integrated Solar Input Powaer 1300OW: External Gen Start Based on Voltage Integrated Max Allowed PV Power 650OW+650OW=13000W or%SOC Max PV Power Delivered to Battery& 12000W Communication to Lithium Battery CanBus&RS485 AC Outputs Max DC Voltage(Voc) 500V @ 18A,450V @ 20A General MPPT Voltage Range 150-425V Dimensions(H x W x D) 30.0"x 18.3"x Starting Voltage 125V 10.01, Number of MPPT 2 Weight 78 Ibs Max Solar Strings Per MPPT 2 Enclosure NEMA 3R Max DC Current per MPPT(Self Lim- 20A Ambient Temperature -25-S5°C,>45°C iting) berating Max AC Coupled Input(Micro/String 960OW Installation Style Wall-Mounted Inverters) Wi-Fi&LAN Communication Included Standard Warranty(verified by HALT Testing) 10 Years AC Output Power SIM On-Grid & Off-Grid Connections 120/240/208V Split Phase Continuous AC Power to Grid(On-Grid) 9000W 37.5A-L(240V) Continuous AC Power to Load(Off- 9000W 37.5A-L(240V) Protections & Certifications Grid) Electronics Certified Safety by SGS Labs to NEC Yes Surge AC Power 10sec 16,000VA L-L(240V) &UL Specs-NEC 690.46&NEC 705.4/6 Surge AC Power 100ms 25,000VA L-L(240V) Grid Sell Back—UL1741-2010/2018,IEE- Yes Parallel Stacking Yes E1547a-2003/2014,FCC 15 Class B,UL1741SA, CA Rule 21,HECO Rule 14H Frequency 60/5OHz PV DC Disconnect Switch—NEC 240.15 Integrated Continuous AC Power with Grid or 1512OW 63A L-L(240V) Ground Fault Detection— NEC 690.5 Integrated Generator PV Rapid Shutdown Control—NEC 690.12 Integrated CEC Efficiency 96.5%(Peak 97.5%) PV Arc Fault Detection—NEC 690.11 Integrated Idle Consumption Typical—No Load 60W PV Input Lightning Protection Integrated Sell Back Power Modes Limited to Household/Fully PV String Input Reverse Polarity Protection Integrated Grid-Tied AC Output Breakers-63A Integrated Design(DC to AC) Transformerless DC Response Time(Grid-Tied to Off-Grid) 4ms 250A Battery Breaker/Disconnect Integrated Power Factor /-0.9-1.0 fTpe] Surge Protection DC Type II/AC + II OVER-THE-COUNTER BUILDING PERMIT CHECKLIST FOR RESIDENTIAL SOLAR PHOTOVOLTAIC SYSTEMS: ROOFTOP MOUNTED Contractors can apply for an Over-The-Counter(OTC)permit where the PV system meets the requirements listed in this Checklist.All project plans and supporting documentation must be provided on site for the inspector. --------TO BE COMPLETED BY APPLICANT------- - Project Information Property Owner Name: Leslie Coulter&Bruce Santy Project Address: 261 E Capital Peak Dr Parcel# City: Shelton State. WA ZIP: 98584 Day Phone: (360) 522-2147 Contractor Name South Sound Solar Contractor License#: SouthSS902N7/SouthSS902J3 Contractor day phone: 360-352-7869 Describe project: conventional framed built dwelling or garage, Pole structure,steel building,etc. Note: Manufactured/mobile homes require L&I Approval PV system description (include manufacturer and model#of manufacturer Installations of 16 Silfab 380 watt solar panels and 1 Sol-ark 12k Inverter. for a 6.08 kW Solar Array. modules and inverters): Also includes a 18.5 kW Fortress Battery ©Determine if your project qualifies for expedited permitting: Yes No 1. PV system is designed and proposed for a detached one-or two-family dwelling or townhouse not more than three stories above grade or detached accessory structure that ❑ is code compliant to setbacks and height,or code allows expansion of nonconformity for solar modules. [IRC 101.2] 2. Modules on pitched roofs do not exceed the highest point of the roof unless approved by ❑ the local jurisdiction. 3. Rooftop is made from lightweight material such as a single layer of composition shingles, EZ ❑ metal roofing, lightweight masonry,or cedar shingles. 4. The installation shall comply with the manufacturer's instructions. [IRC M2302.2] EX ❑ 5. The installation shall meet the requirements of NFPA 70 National Electric Code,and all required electrical permit(s) must be obtained from the Authority Having Jurisdiction to V ❑ administer the electrical code. [IRC M2302.2] 6. The installation shall meet the requirements of the International Fire Code as amended V ❑ by WA State. [IRC M2302.21 7. The PV system is designed for the wind speed of the local area, and will be installed per lZ ❑ the manufacturer's specifications. [IRC M2302.2.1(1)] 8. The ground snow load does not exceed 70 pounds per square foot. [IRC M2302.2.1(2)] SZ ❑ 9. Total dead load of modules, supports, mountings, raceways and all other appurtenances V ❑ weigh no more than four pounds per square foot. [IRC M2302.2.1(3)] I Enter total dead load of system (lbs/ft'): Click here to enter text. 10. To address uplift, modules are mounted no higher than 18" above the surface of the ❑ roofing to which they are affixed. [IRC M2302.2.1(4)] 11. Supports for solar modules are installed to spread the dead load across as many roof- framing members as needed to ensure that no point load exceeds fifty(50) pounds. ❑ [IRC M2302.2.1(5)] 12. The photovoltaic modules and supporting structure shall be constructed of noncombustible materials or fire-retardant treated wood equivalent to that required for ❑ the roof construction. [IRC M2302.2.1] 13. Roof and wall penetrations shall be flashed and sealed to prevent entry of water, ❑ rodents, and insects. [IRC M2302.2.2] 14. PV modules are listed and labeled with a fire classification in accordance with UL 1703. ❑ [IRC M2302.2.3] Comments: Click here to enter text. If you answered yes to all of the above questions,the project qualifies for the over-the- counter permitting process. Q Submit this Checklist, Site Plan, and other required permit application forms to: [insert contact info for jurisdiction having authority] As the property owner or authorized representative of the above listed property, I attest that all information in this checklist is accurate to the best of my knowledge. Applicant Signature: Date: 4/28/2022 Applicant Name (Please Print): --------TO BE COMPLETED BY MASON COUNTY STAFF------ Qualifiesfor OTC Building Permit? ❑Yes ❑No Permit Application#: Staff Initials Date: 2 boa Co�� MASON COUNTY COMMUNITY SERVICES PERMITASSISTANCE CENTER: Permit No: •BUILDING•PLANNING•FIRE MARSHAL 615 W.Alder St-Shelton, WA 98584 Phone Shelton:(360)427-9670 ext. 352 Fax:(360)427-7798 Phone Be/fair(360)275-4467 Phone Elma:(360)482-5269 18.14 PLUMBING & MECHANICAL PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFORMATION: NAME:Leslie Coulter&Bruce Santy NAME:south sound solar MAILING ADDRESS:261 E Capital Peak Dr MAILING ADDRESS:4511 Lemon Rd NE CITY:Shelton STATE:WA ZIP:98584 CITY:Olympia STATE:WA ZIP:98506 151 PHONE:(360)522-2147 PHONE:360-352-7869 CELL: 2°1 PHONE: EMAIL :Rosie@southsoundsolar.com EMAIL:lcphotog@outlook.com L&I REG#603006850 EXP. 08 /27 /22 PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number): Zoning: LEGAL DESCRIPTION(Abbreviated): SITE ADDRESS:261 E Capital Peak Dr Shelton WA 98584 CITY:Shelton DIRECTIONS TO SITE ADDRESS: TYPE OF JOB NEW x ADD ALT REPAIR OTHER USE OF BUILDING LOCATION OF FIXTURES/UNITS— I ST FLOOR 2ND FLOOR BASEMENT GARAGE OTHER x root PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No.of Fixtures Fees Fuel Type:Electric—LPG Natural Gas Ductless_ Toilets Type of Unit No. of Units Fees Bathroom Sink Furnace Bath Tubs Heat Pump Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer Gas Outlets Kitchen Sinks Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hose bibs Dryer Vent Other Solar Panel 1 Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. X kOl 'kU*PU� 4/28/2022 Signature of Applicant Date X Rosie Rumsey Owner/Owners Representative ontractor Print Name (Circle one) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL Visit us on-line: http://www.co.mason.wa.us/community_dev/ Rev:1/27/2016 JBN