Loading...
HomeMy WebLinkAboutSWG2022-00051 - SWG Application / Design - 2/10/2022 415 N 6TH STREET,SHELTON,WA 98584 4/001 MASON COUNTY SHELTON:360 427-9670,EXT 400 a I. 1 COMMUNITY SERVICES BELFAIR:360-275-4467,EXT 400 ELMA:360-482-5269,EXT 400 .�ijOuitding,Plummy,Environmental Health,Community Health i,r .,� CommunityFAX:360-427-7787 On-Site Sewage System Tank Only Permit: SWG2022-00051 APPLICANT FIELD ASSEMBLY INC Phone: 360.701.0188 Address: 8411 OLD HWY 99 SE TUMWATER, WA 98501 OWNER STENERSON ET AL IAN ANDREW& Phone: 360-471-5998 JAMIE DAWN Address: SANDRA ELAINE STENERSON SHELTON, WA 98584 SEPTIC INSTALLER CHRIS SMITH-CK Construction Phone: 360-789-1763 Address: 9341 CRETE STREET SOUTHEAST OLYMPIA, WA 98501 Site Address: 121 E STONEBRIAR PL Primary Parcel Number: 321323290112 Permit Description: Pump tank for garage (no bedrooms) Permit Submitted Date: 02/10/2022 Permit Issued Date: 02/14/2022 Issued By: Luke Cencula Current Permit Fees Paid: $240.00 (additional fees may be required upon installation of system). Permit Expiration Date: 02/14/2023 (based on date of inspection) Type of Work OSS New Construction Components being Replaced: Pump Tank Only Surfacing Sewage? No Existing Failure? No Shoreline? No Horizontal Setbacks Met? Yes Number of Bedrooms: 0 Drinking Water Source: Private Well/Spring Site plan submitted with BLD2021-01043. We are installing a 2 Additional Details: chamber tank with a pump to the existing 4 bedroom septic and drain field. Permit Conditions: 3 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 4 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. 5 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 2 Horizontal setbacks per WAC246-272A-0210 must be maintained, unless prior approval is obtained 1 Tank must be on current WA DOH List of Registered Sewage Tanks. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND/OR DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: www.co.mason.wa.us/health/environmental/onsiteloss-inspection-request.php or call: 360-427-9670, extension 400. OFFICIAL USE ONLY DATE RECEIVED: \ . " MASON COUNTY .I 1. COMMUNITY SERVICES AMOUNTRECENED: RECEIVED BY: _ v_ m Public Health(Community Health/Environmental Health) C N 360-427-9670.ext.400 or 360-275-4467,ext 400 ('' 4I5 N.6th Stmet-Shekon,WA 98584 SWG �v a, �. OCx�GJ O x it vv Z ON-SITE SEWAGE TANK ONLY APPLICATION v rn m APPLICANT PHONE r Ian Stenerson 360-471-5998 z MAILING ADDRESS-STREET,CITY,STATE,ZIP CODE 3 121 E Stonebriar PI, Shelton WA 98584 asm SITE ADDRESS-STREET,CITY,ZIP CODE Same NAME OF DESIGNER PHONE NAME OF INSTALLER PHONE 0 Chris Smith, CK Construction 360-789-1763 < TYPE OF WORK(select one) DRINKING WATER SOURCE O Ij NEW CONSTRUCTION/UPGRADES 0 REPAIR/REPLACEMENT 0 PRIVATE INDIVIDUAL WELL 0 PRIVATE TWO-PARTY WELL Z COMPONENT(S)TO BE REPLACED/INSTALLED CIPUBLIC WATER SYSTEM I t ❑ SEPTIC TANK Iii PUMP TANK ❑RV HOLDING TANK BEDROOMS LOT SIZE ❑ OTHER 0 1.0 Acre CO SETBACK CHECKLIST 0 OTHER DETAILS(select all that apply) TANK(S) t ❑ SURFACING SEWAGE 0 EXISTING FAILURE 0 SHORELINE 0 100FT+PUBLIC/COMMUNITY WELLS n X SUBMITTALS 0 SOFT+PRIVATE WELLS,SURFACE WATERS.STREAMS.RIVERS II PLOT PLAN(REQUIRED) O TANK CROSS SECTION(REQUIRED) ❑ 10FT+DRINKING WATER SUPPLY LINES ❑ PUMP DETAILS(IF APPLICABLE) 0 WAIVER(S)(IF APPLICABLE) 0 5FT+PROPERTY/EASEMENT LINES,FOUNDATIONS,FOOTINGS I— PLOT PLAN CHECKLIST 0 ❑ PROPERTY LINES AND EASEMENTS 0 EXISTING/PROPOSED STRUCTURES CIEXISTING/PROPOSED OSS COMPONENTS AND LINES ❑ WELLS WITHIN 100FT 0 WATER SUPPLY LINES 0 DRIVEWAYS!PARKING ❑SURFACE WATERS,STREAMS,RIVERS,ETC... ❑ DIRECTION OF SLOPE/CONTOURS ❑ PERIMETER/CURTAIN DRAINS ❑ NORTH ARROW 0 SCALE BAR DIRECTIONS TO SITE AND SITE CONDITIONS:(ex.locked gate) OFFICIAL USE ONLY BELOW THIS LINE UPGRADE/FAILURE SOURCE(for reporting purposes) ❑VOLUNTARY 0 MAINTENANCE/PUMPING IILDING PERMIT ['HOME SALE ['COMPLAINT ❑OTHER: COMMENTS I CONDITIONS SEWAGE TANKS MUST BE LISTED UNDER DOH'LIST OF REGISTERED SEWAGE TANKS'. TANKS MUST MEET CURRENT MINIMUM SIZE REQUIREMENTS,EQUIPPED WITH RISERS AND LIDS TO SURFACE,AND INCLUDE AN EFFLUENT FILTER(IF APPLICABLE). RECORD DRAWING AND INSTALLATION REPORT REQUIRED FOR FINAL APPROVAL. INSPECTOR SIGNATURE DATE APPLICATION EXPIRATION DATE APPLICATION APPROVED/ISSUED BY DATE • ��r I(1,W .B 7 114 F�r�- THIS FORM MAY BE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON 74E MASON COUNTY WE REVISED 12/7/2015 ANIMIIMIENIIIIIIII Q ' ;;<< V8986 eM'uo;la4S 3 R a O g Id Jeugauo;s)sea LZl a s • Xm VOHVJ NOS2�RNA1S N Q re O 6 U�fi A « u a 3 § & 2 oE' iii xil 4 AlE il . 1 -- -, l= 1 3 l .,1 W j 1 a .t1.\ Ill ! lii ,_ _ I-_ 1 17) J N LAE z pp pRO\I el) F F 1NO'N1P��e. . n , HD Fowler Company Submittal - PBSEV412 67840 Series SEV412 BAR V ES r 2 Spherical Solids Handling Manual &Automatic www.cranepumps.com VA",", 2" & 3" Discharge 1111111.1111111111111 DISCHARGE 2"NPT,Female,Vertical LIQUID TEMPERATURE 77°F(25°C)Continuous MOTOR HOUSING Cast Iron PUMP BODY Cast Iron ����� IMPELLER: Design Multi-Vane,Vortex Tr- .4:4 Material Cast Iron SHAFT 416 Stainless Steel 0-RINGS Buna-N HARDWARE 300 Series Stainless Steel PAINT Air Dry Enamel CORD ENTRY 20 ft.(6m)Quick Disconnect Cord with plug on 115 Volt,Pressure Gromment for sealing and strain relief SEAL: Design Single Mechanical,Oil Filled Reservoir Material Carbon/CeramiclBuna-N Hardware-300 Series Stainless - 40 05 SPEED 3450 RPM(Nominal) Ir+ UPPER BEARING Single Row, Ball,Oil Lubricated LOWER BEARING Single Row,Ball,Oil Lubricated �__- � P. 11 MOTOR: Design Oil Filled Insulation Class B SINGLE PHASE Permanent Split Capacitor(PSC) Includes Overload Protection in Motor LEVEL CONTROL: SEV412 None SEV412A. Wide Angle,Mechanical,20 ft(6m)cord Pipe Mounted SEV412VF Vertical Float,PVC.Snap Action SEV412VFT Attached Vertical Float,PVC,Snap Action SEV412AT Wide Angle,Mechanical,20 ft(6m)cord Series: SEV Pump Mounted .5HP, 3450RPM, 60Hz RECOMMENDED: Accessories Break Away Fitting(BAF) Check Valve Control Panel DESCRIPTION: SUBMERSIBLE NON-CLOG SEWAGE PUMP DESIGNED FOR TYPICAL RAW SEWAGE APPLICATIONS WARNING: IA CANCER AND REPRODUCTIVE HARM- • WWW.PSSWARNINGS.CA.GOVV S� stu c G.us [---CERTIFIEC!d � MEMBER LR16567 !SECTION PAGE 1U ION 18 CRAN E_1 PUMPS & SYSTEMS DATE 12/18 A Crane Co.Company USA: (937) 778-8947 • Canada:(905)457-6223 • International: (937)615-3598 HD Fowler Company Submittal - PBSEV412 67840 Series SEV412 2" Spherical Solids Handling B1RFJES www.cranepumps.com Manual &Automatic 1%", 2" & 3" Discharge SEV412A II,)�I ■1111111110SEV412(Less Float) SEV412AT(Attached to Motor Housing) �I. BARNES ll WARNING l� LABEL '/. 0105506 y�/ - 963_ 1�'A I ---- (245) - -1.38(35) IIIII L 1 I 4.75 �. 903 _ I (42(�:_/ PUMPING (229) 'NEW 3 5C �,�FERENT!AL I E ��� (69) 7.00 /399 ,� V -'�� (176) SEV412VFT 6.38 ES I (162) \-NAMEPLATE WB MN 9.63 I �_ WARNNG I Jai _LABEL '---(245)---- 1.38(35) pt05506 _4.75 I---._.-r i--- i (I21) NAMEPLA? � il 1 9, SEV412VF l -rle� �) l 706 15.69 75(19)T08.25(210) p (178) BARN IN 1399) .� PUMPING 1 DIFFERENTIAL •` WARNING / LABEL ®� ..._.__ ._ M705506 _ J 4: 6.38 8.03 it } 1245) ..._- 1.38(35) I I '- --1 4.75 --NAMEPLATE .75(19)TO 8.25(210I -I (121) ..5 69 PUMPING '►--- 3.60 l 395) DIFFERENTIAL �', (6A) a 178 I s� (t78) Ib �3g � �``, l 002? MODEL NO PART NO HP VOLT/PH Hz RPM NEMA FULL LOCKED CORD CORD CORD (Nom) START LOAD ROTOR LENGTH SIZE TYPE CODE AMPS AMPS cSEV412 101292 0.5 115/1 60 3450 H 10.50 18.6 20 ft.(6m) 14/3 SJTOW SEV412A 101293 0.5 115/1 60 3450 H 10.50 18.6 20 ft.(6m) 14/3 SJTOW SEV412VF 101294 0.5 115/1 60 3450 H 10.50 18.6 20 ft.(6m) 14/3 SJTOW SEV412AT 103544 0.5 115/1 60 3450 H 10.50 18.6 20 ft.(6m) 14/3 SJTOW SEV412VFT 110404 0.5 115/1 60 3450 H 10.50 18.6 20 ft.(6m) 14/3 SJTOW IMPORTANT ! 1.) PUMP MAY BE OPERATED`DRY-FOR EXTENDED PERIODS WITHOUT DAMAGE TO MOTOR AND/OR SEALS. 2.) INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA 70 AND/OR THE AUTHORITY HAVING JURISDICTION.THIS PUMP IS NOT INTENDED FOR USE IN SWIMMING POOLS.RECREATIONAL WATER PARKS,OR INSTALLATIONS IN WHICH HUMAN CONTACT WITH PUMPED MEDIA IS A COMMON OCCURRENCE Ej PUMPS & SYSTEMS PAGE 11 [CRAN - SECTION 1B DATE 2115 A Crane Co.Company USA: (937)778-8947 • Canada: (905)457-6223 • International: (937)615-3598 HD Fowler Company Submittal - PBSEV412 67840 Series SEV412 BARNES®' Performance Curve .5HP, 3450RPM, 60Hz www.cranepumps.com 1%", 2"j 3" Discharge TOTAL HEAD inches (mm) METERS FEET 25 rlitlik.7. ■ ■�■■■■■■■■■■ • ._ STANDARD IMPELLER SIZES 1..■.,. ■•■■■■■■■■■■ ■■ 7 — ■■■ - ' ■■■■■■■■■ ■■■ Pump HP Impeller Dia. 0.5 3.12(79) �tlo. , 6 — 20 ■■■■ ■■■■ \. �� ■■■■■ 111 111111IIIIHIlh!!flhIII.iIl 5 — ■■■■■■■■ ■■■■■■■11111111 111111101621111111111111111111111111 ■■■■M\■■■■■■■■■■■■■■■■■■■■■■■ 1■■■■ ■ ■■■■■■ ►\ ■■■■■■■■■■■■■■■ ■■■ ■■■■1■ ■■■■■■11 1 .C� ■■■■■■■■■■■■■■■C■■■ 15 ■ ■ ■ "llliilibliiililbllflhliliiiu11iiIiHhIlilII�►`■■■■■■■■■■i11i1i1i4 — ■■ ■ iiiiiiiiiiiiiii1ii1 1i ►i11 111 3 — 10 11111111111111 1111 1 1 1 11111111111111 2— 111111111111 1■111■■■/1■ 1■111111: 11111 5 11I11111111 liii... 1 — - ■ . ■■■.■■■. ■■■■ ■■■. 1■111 ■■■■■■1 . ■■■1■■■■ 11111 -■■■■__.- ■■ ■ ■■■■■■ V101292 U.S.GALLONS 20 40 60 80 100 PER MINUTE I I I I I I ' LITERS 1 2 3 4 5 6 PER SECOND Testing is performed with water,specific gravity 1.0 @ 68°F @(20°C),other fluids may vary performance P G 1 1B PAGE2 CRANE , PUMPS & SYSTEMS DATE 3/13 A Crane Co. Company USA: (937)778-8947 • Canada: (905)457-6223 • International: (937)615-3598 r THE CONC E SE CE, Prec ep is Tank C. 742 West Front Street - Tr erne City,MI 4 -8152 - 231-946- 0 - www. ncreteservice.com L?�-- I 1I / 12-x18" conc. lid 4110— 5.-0" -- Outlet � _-� rY--� r' End Inlet 18" dia. conc. lid 30" dia. conc. Ii r�1 Side Inlet Top Weight: 4,760 Ibe. (6' knockout) (11 cy concrete) Aoritia 4 I "• -Liquid Level -- 0 C r 4 J — End Inlet Outlet 2g Concrete baffle - (2) pl 56" 49' 28" Compartment barrier 35" 73" Bottom Weight: 4.400 lbs. (1+ cy concrete) Notes: 1. Typical wall thickness is 2. Unless otherwise not , end inlet & outle ore fitted with polylock occ ing pipes up to 6" a. 10 d-49 3. Concrete acce lid(s) shown are inclu d 4. Plostic tees hown ore included 5. Dimensio shown are approximate o ly Outside 1 x 120L x 56ri Total eighhtt 9,160 lbs 6. Tank ay have internal support rib or similar structure Cop ity 1,000 gc. no shown above Print Dote. 05/06/2008 - 2:59pm ,... - - THE CONCRET Prec Se is Tank SERVIC ,IN peci Order Isxett ---- 374 est Front Street - Trav rse City,MI 49 -8152 - 231-94 880 - www.thecoservice.com 7 --- - , I , L'1—_n I , r 18" dia. 1 conc. lid (3) 1 1 I L. — (E :- 4— --+ 1 i f_ 0 Outlet __I1— —' r End Inlet I 1 1 I 1 i Side Inlet Top Weight: 3,440 lbs. (6" knockout) (}+ cy corcrete) rasseamwas �a���Owrsn� ( Liquid Level 01—_ �-- 1 ji a' © End Inlet Outlet 28" —————— iii_- �k 56" Plastic tee 49" Concrete baffle 288" I i ���� , , 27" — ?—._ 56" — ? Bottom Weight: 3.120 lbs. 0 cy concrete) Notes: 1. Typicol wall thickne is 3.5" 2. Unless otherwis noted, end inlet Sc o et ore fitted O with polylo accepting pipes up to dia. 3. Concre access lid(s) shown ore ' cluded 4. Plo c tees shown ore included Outside Dim. 48W x 96L x 56H 5. lmensions shown ore opproxi• ate only Total Weigh 6,560 lbs . Tank may have internal supr•rt ribs or similar stru es Capacity 600 ga. not shown above Print Date: 08/21/2005 — 11:56pm