HomeMy WebLinkAboutBLD2020-01589 Detached Garage with Bathroom - BLD Permit / Conditions - 4/20/2021 ' Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg. 8
Shelton,WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
F
-01589 GARAGE/ STORAGE
ESCRIPTION: NEW DETACHED GARAGE WITH ISSUED: 04/20/2021
(ADDED 9/29 PROPANE TANK, LINES &GENERATOR)
ESS: 571 E CRONQUIST RD ALLYN EXPIRES: 03/21/2022
PARCEL: 122321092140
APPLICANT: SMITH MARK B&SERENA OWNER: SMITH MARK B&SERENA
560 E CRONQUIEST RD 560 E CRONQUIEST RD
ALLYN,WA 98524 ALLYN,WA98524
1.253.380.5221
VALUATIONS: FEES: Paid Due
U VB Utility, miscellaneous 2706.00 $132,025.74 Mechanical Fees $116.00 $0.00
Technology Surcharge $44.98 $0.00
Change in Tenant- Minor EH $120.00 $0.00
Plan Review
Plan Check Fee $838.66 $0.00
Mechanical Base Fee $30.00 $0.00
Planning Review Fee $240.00 $0.00
Plumbing Base Fee $25.00 $0.00
Plumbing Fees $36.00 $0.00
Building Permit Fee $1,290.24 $0.00
State Fee-Residential $6.50 $0.00
Mechanical Revision Base Fee $10.00 $0.00
Total: $132,025.74 Totals : $2,757.38 $0.00
FIXTURES
(sty Mechanical Fixtures M} , � q ( t Plumbing Fixtures
1.0000 Gas Outlet(s)(1-5) ► )C (!` / % 1.0000 Bathroom Sink
1.0000 Spot Vent Fan(s) 1.0000 LAUNDRY TRAY
1.0000 Number of Toilets
1.0000 Number of Water Heaters and or Vent
Printed by:Ariane Paysse on:09/29/2021 01:39 PM
Page 1 of 5
Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg.8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
GARAGE/ STORAGE BLD2020-01589
Qty Mechanical Fixtures
1.0000 For the installation or relocation of each boiler or
compressor to and including 3 horsepower(10.6
kW), Or each absorption system to and including
100,000 Btu/h(29.3kW)
1.0000 Propane Tank(s) fddA VC1
REQUIRED INSPECTIONS
Setback Inspection Framing Inspection
Footing Inspection Rough- Plumbing Inspection
Foundation Wall-Pre-Pour Inspection Mechanical Inspection
Underground Plumbing Insulation Inspection
Slab Insulation BLD-Final Inspection
Shearwall Inspection Gas Piping Inspection
CONDITIONS
The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not
allowed without the approval of the Mason County Fire Marshal.
* Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate
building permit and approval prior to construction of the retaining wall.
All property lines shall be clearly identified at the time of foundation inspection.
Concrete used for basement walls,foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather,
garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of
3000 psi (IRC Table R402.2).
" When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by
the Mason County Department of Public Works. For more information contact Public Works, at (360)427-9670, ext. 450 or
100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the
access permit from Public Works has been finaled and approved.
The foundation/footing must be placed on undisturbed, firm-native soil.
The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility
of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked
"APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is
responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of approved documents will result in failure of required building inspections.
When parcel development requires direct access to state road(s), a Road Access Permit or Approval must be granted and
approved by the Washington State Department of Transportation. For more information contact Washington State
Department of Transportation, at(206)357-2620, ext. 630.
Printed by:Ariane Paysse on:09/29/2021 01:39 PM
Page 2 of 5
r'
Mason County
Mason County - Division of Community Development
615 W. Alder St. Bldg. 8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
GARAGE/ STORAGE BLD2020-01589
" Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a
permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor
& Industries (L&I).
For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415-
4000.
* All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as
adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted
classification. Any non-approved change of use or occupancy would result in permit revocation.
* All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or
any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction.
* CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING
DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All
construction must be in conformance with the international codes as amended and adopted by Mason County. Any
corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting
additional inspections.
* Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries,
Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an
unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either
the homeowner, agent for the owner or a registered contractor according to WA state law.
* All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and
plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee
schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections
being performed or approvals granted.
* All building permits shall have a final inspection performed and approved by Mason County Building Department prior to
permit expiration.The failure to request a final inspection or to obtain approval will be documented in the legal property
records on file with Mason County as being non-compliant with Mason County ordinances and building regulations.
* Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and
MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either
private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an
existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance
and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting
from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any
construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that
office to review future planned work which may affect your project.
* All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor
increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way.
* Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly
corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of
pressure treated material.
* The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more
than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards
for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to
another fire apparatus access road which connects to a county maintained public road.
Printed by:Ariane Paysse on:04/20/2021 08:58 AM
Page 3 of 5
Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg. 8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
GARAGE/ STORAGE BLD2020-01589
* A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit
application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the
responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that
Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement
of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater
Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel
Stormwater Site Plan"constitutes an approved plan based on the criteria listed on the application/worksheet. If the
development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other,
parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final
inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater
management system have been installed as approved on the stormwater site plan.
Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and
MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either
private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an
existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance
and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting
from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any
construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that
office to review future planned work which may affect your project.
* Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the
structure.
* The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the
approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule,
minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being
performed or approvals granted.
* OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit
revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or
contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained
permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County
access to the above described property and structure(s)for review and inspection. This permit/application becomes null &
void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of
180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT
APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
* Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site
plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed.
* WIND LOADS- Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic
wind speed for Mason County is 85 MPH.
* By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your
"Approved Site Plan"to ensure these structures meet the setback conditions listed.
* Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to
the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of
the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In
addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the
Building Department prior to any further inspections being performed or approvals granted.
Printed by:Ariane Paysse on:04/20/2021 08:58 AM Page 4 of 5
Y S F
Mason County
Mason County - Division of Community Development
615 W. Alder St. Bldg. 8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
GARAGE/ STORAGE BLD2020-01589
" A separate inspection in addition to the inspections required in the IBC, Section 110 shall be required in accordance with
the 2015 IBC, Section 1705.12.2 and Section 1707.1. The additional inspection is required when shear wall fastener
spacing is required to be 4 inches or less. The shear wall schedule shown on sheet S3 designate wall(s)type SW2, SW3,
GARAGE PORTAL WALL(501), AND MUD SILL with fastener spacing 4 inches or less.
The required inspection may be performed by the Mason County Building Department, a WABO certified inspector, certified
to inspect lateral connections, the Engineer of record (EOR), or an authorized representative of the (EOR). The special
inspectors duties and responsibilities shall be as specified in Chapter 17. When a third party inspector is used to perform the
inspection, special inspection reports shall be submitted to the Mason County Building Department, 615 W Alder St, Shelton,
WA 98584 and also available on site for review by the Building Official. Inspection reports shall be completed and submitted
to the Mason County Building Department in a timely manner and shall be submitted prior to the framing inspection of said
project.
Any future structure toward the water will require a Geo Report
Application acknowledges that the structure is only permitted for a use consistent with the current zoning of the parcel.
" Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered.
A.) Drainfield/Reserve requires a 1Oft setback from all footing/foundations.
B.)Septic tank(s) requires 5ft setback from all footing/foundations.
C.) No foundation/Perimeter Drains within 30ft, down gradient of Drainfield/Reserve area.
D.) No Cut Bank(s) (greater than 5ft and over 45 degrees)within 50ft, down gradient of Drainfield/Reserve area.
I hereby certify that I have read and examined this application and know the same to be true and correct.
All provisions of Laws and Ordinances governing this type of work will be complied with whether
specified herein or not. The granting of a permit does not presume to give authority to violate or cancel
the provisio of other state/local law regulating construction or the performance of construction.
Issued By:
Contractor or Authorized Agent: Date: ?O Z
Printed by:Ariane Paysse on:04/20/2021 08:58 AM
Page 5 of 5
INSPECTION CARD
Mason County
615 W. Alder St. Bldg. 8, Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
PERMIT# BLD2020-01589 PROJECT ADDRESS 571 E Cronquist Rd Allyn, WA 98524
PARCEL# 122321092140 PROJECT DESCRIPTION NEW DETACHED GARAGE WITH BATHROOM
OWNER SMITH MARK B&SERENA ADDRESS 4220 E STATE ROUTE 302 PHONE 1.253.380.5221
CONTRACTOR ADDRESS PHONE
CONTRACTOR LICENSE LENDER
INSPECTION INSP DATE Comments INSPECTION INSP DATE Comments
Setback Inspection y Framing Inspection L h Q-�j-2 t/��ri ;eof coerer,ly'
Footing Inspection Cl.N1 yQ nl py4erjor Padfj& Rough-Plumbing Inspection
Foundation Wall-Pre-Pour /��` ( Mechanical Inspection CLM q-22 21 Ve/i F� Correc f}&.cs.
Underground Plumbing S- 2 Insulation Inspection CLM -22.2►
Slab Insulation L�- BLD-Final Inspection
Shearwall Inspection At -br2 Gherk LST Wrq f'CA6,«itp/j4ee l 9�(13�2( D See 4-W
�J/
Check i*rior �4n�rl AFAT � SAS Ce- 1�-21 Dec. cove--.
boo fia9
�'v�v n9 a�1�o�c� '��v'�c�-t... j I ►Yv�J� $ ��r'"utn'u'� ��L�t lZc'z
CCA
�
360-427-9670 Shelton ext.352
MASON COUNTY
COMMUNITY SERVICES 36 60-482-52 Be lm ext.352
360-482-5269 Elma ext.352
Building, Planning,Environmental Health,Community Health
615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.co.mason.wa.us
CORRECTION/INSPECTION REPORT
PERMIT/CASE NUMBER: LELDZoZo—&/Sy?
ADDRESS/LOCATION: sw e xv
FINDINGS:
F o-
h i4 A" mw*-ed 01.E st46Ws 1,;4 OGtQ Le# &A41
—X—clteek OVAkd 2 P xtts-o !au �us,�ee loiie
o L cover s�ev—
z z e,✓ E -4 ou
W E>re cJ C fW.FSoti edog oAddreff
&k TO .LKS a144 X- eOM ArkAKee- o G r- usver cQ e!-
p�
Items listed above must be corrected to gain compliance.
❑ THIS IS NOT A COMPLETE INSPECTION
❑ This structure has been inspected by Mason County Building Department and the items listed
above are in VIOLATION of Mason County laws and/or ordinances.
❑ Call for re-inspection when corrections are made before proceeding with any further work.
Make corrections, items will be checked on the next inspection.
❑ OK to
Date: ❑ Please contact our office regarding possible
Department: LLD structural damage incurred by recent
Inspector: "natural/man made"disasters.This is NOT a
CORRECTION NOTICE.
DO NOT REMOVE THIS TAG
MCC14.12
MASON COUNTY COMMUNITY SERVICES Permit No:
PERMIT ASSISTANCE CENTER:
•BUILDING•PLANNING•PUBLIC HEALTH•FIRE MARSHAL
615 W.Alder Street,Shelton,WA 98584 DEC 0 3 2020
Phone Shelton:(360)427-9670 ext.352•Fax:(360)427-7798 Phone
Bettair.(3W)275-4467•Phone Elma:(360)482-5269
BUILDING PERMIT APPLICATION 615 W. Alder Street
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME:
MAILING ADDRESS: P&PA90X /Z/7 MAILING ADDRESS:
CITY: ALL VIV STATE: ZIP:Yff I CITY: STATE: ZIP:
PHONE#1: tS3.380•S 2 Z/ PHONE: CELL:
PHONE#2: EMAIL:
EMAIL:BS/9/7islG SWIL#,=— Z CDH L&I REG# EXP.
PRIMARY CONTACT: owNEXX, CoNTRAcrOR❑ OTHER
NAME EMAIL �.S'h/Th/[] f E 1067
MAILING ADDRESS CITY STATE ZIP
PHONE CELL
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number) /ZZ 3Z-1O-9W-4 o ZONING
LEGAL DESCRIPTION(Abbreviated) VW-*- P /Wf aZ-ZZ-/ FIRE DISTRICT S
SITE ADDRESS 5-7/A7+ C/laYILW/SrAQb CITY 411—VA1
DIRECTIONS TO SITE ADDRESS �ir1/�l!/Et[l /J �1�i�1� 7?7 t''J719/��LL/Cr
.
14✓.: YES NO SNOW LOAD: sf
IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN ❑ � —P
IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (checikau dwt apply):
SALTWATER,$( LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑
TYPE OF WORK: NEW' ADDITION❑ ALTERATION❑ REPAIR❑ OTHER [IUSE OF STRUCTURE(Rer ,drncr,Q w roatak,aar BN&Btra) 46r~616RE
IS USE: PRIMARY SEASONAL❑ NUMBER OF BEDROOMS NUMBER OF BATHROOMS
HEATED STRUCTURE? YES MI.I.Bldg)g YES(Part(e)ofBld,,)❑ NO❑
DESCRIBE WORK 6,fA 1—= CCNIST/l/YGT/�
SOUARE FOOTAGE:(proposed)
1ST FLOOR sq.& 2ND FLOOR sq.8 3RD FLOOR sq.ft BASEMENT sq.ft
DECK sq.fL COVERED DECK sq.ft STORAGE sq.ft OTHER sq.fL
GARAGE1740lysq.ft Attached❑ Detachedg CARPORT sq.fL Attached❑ Detached❑
MANUFACTURED HOME INFORMATION: "4 COPIES OF THE FLOOR PLAN REQUIRED*
MAKE MODEL YEAR LENGTH
WIDTH BEDROOMS BATHS SERIAL NUMBER
ENVIRONMENTAL HEALTH:
SEWAGEISEWER SOURCE: SEPnC'g SEWER❑ I NEW❑ EXISTINGIK
PLUMBING IN STRUCTURE? YE$X NO❑ I,ryes,attach completed Water Adequacy Form
PERIlvIETERNOUNDATION DRAINS PROPOSED? YES-9 NO❑ EXISTING SQ.FT.
EXISTING BEDROOMS PROPOSED BEDROOMS TOTAL BEDROOMS
OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by
signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have
obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal
representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permitlapplication becomes null&void if work or authorized construction is not commenced within 180
days or if construction work is suspended for a period of 180 days.
PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 QrS OF MORf WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON
C CODE 14.08 42)
X ff-.,A 9 /3 gg
'SligtTature of OWNER(Mrst be sinned by the OWNER) mate
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDTTIONS
BUILDING DEPARTMENT JT)_ Z-B
PLANNING DEPARTMENT
FIRE MARSHAL
PUBLIC HEALTH J
MASON COUNTY RECEIVED
COMMUNITY SERVICES
Building,Planning,Environmental Health,Community Health
N DEC 0 3 2020
Physical and Mailing Address: 615 W Alder St.,Bldg 8,Shelton,
Shelton Phone: (360)427-9670 ext 352 •S Fax (360)427-7798 15 W r —0,
PLUMBING & MECHANICAL PERMIT APPLICATION Permit#: ICI 2Z2.6 -O I-5t
OWNER IN ORMATION: . CONTRACTOR INFORMATION:
NAME: NAME:
MAILING AD RESS: MAILING ADDRESS:
CITY: STATE: ZIP: CITY: STATE: ZIP:
1st PHONE: PHONE: CELL:
2nd PHONE: EMAIL:
EMAIL: L&I REG# EXP. I I
PARCEL INFORMATION:
PARCEL NUMBER (12 Digit Number): I'oLa3a - I O • CI a--I L4 0 Zoning:
LEGAL DESCRIPTION (Abbreviated):
SITE ADDRESS<5r7 1 E r oa CITY.
DIRECTIONS TO SITE ADDRESS:
TYPE OF JOB/WORK: NEW ADD ALT REPAIR OTHER
USE OF BUILDING
PLUMBING FIXTURES MECHANICAL UNITS [] Electric in-wall heaters(no fee)
Type of Fixture No. of Fixtures Fuel Type Fees Type of Unit No. of Units Fuel Type Fees
Toilet(s) Furnace [E/G/LPG]
Bathroom Sink(s) Heat Pump [E/G/LPG]
Bath Tub(s) o Ductless H.P. _— PG/LPG]
Shower(s) Spot Vent Fan
Water Heater(s) /LPG] Propane Tank
Clothes Washer(s) PG/LPG] Gas Outlet(s)
Kitchen Sink(s) Heat Stove [E/G/LPG/W]
Dishwasher(s) Kitchen Exhaust Hood
Hose bib(s) Dryer Vent
Other r Solar Panel . L
Other lnl[„ l Other IrLT
Plumbing Su total Mechanical Subtotal
Plumbing Base Fee Mechanical Base Fee
Final Inspection Fee Final Inspection Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is
by signature below. I declare that I am the owner,owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to
do the work as proposed.1 have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this
project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above
described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not
commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF
INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
X
Signature of Applicant Date
X Owner/Owners Representative/Contractor
Print Name (Circle one)
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
O Building -JT
O Fire Marshal
O Permit Tech (OTC permit only)
Visit us on-line: hrtp://www.co.mason.wa.us/community_dev/ Rev:3/08/2017
Simple Heating System Size: Washington State
This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA
Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling
loads.
Please fill out all of the green drop-downs and boxes that are applicable to your p'(�],` akQss eli rl nGdrop-downs for each section,
some values will be calculated for you. If you do not see the selection you need in� l dItoptions,please call the WSU Energy Extension
Program at(360)956-2042 for assistance.
Project Information Contact Information
NEW HEATED DETACHED GARAGE-BLD2020-01589 FINAL VISION INC-JASON SCHAUER
571 E CRONQUIST RD,ALLYN WA 98524 1,360,801.5681
12232-10-92140 SCHAUER9@MSN.COM
Heating System Type: O All Other Systems 0 Heat Pump Y-- I Vi D
To see detailed instructions for each section,place your cursor on the word"Instructions". v L_
Design Temperature DEC
Instructions Shelton ---- -----, Design Temperature Difference(AT) 03 2020
A=Indoor(70 depress)-Outdoor Design Temp
Area of Building 615 W. Alder Street
Conditioned Floor Area
Instructions Conditioned Floor Area(sq ft) 2,706
Average Ceiling Height Conditioned Volume
Instructions Average Ceiling Height(ft) 14.0 37,884
Glazing and Doors U-Factor X Area = UA
Instructions
u-o.zB . 0.280 727 203.56
Skvliahts U-Factor X Area = UA
Instructions 0.50 0� ---
Insulation
Attic U-Factor X Area = UA
Instructions R-49 0.026
Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA
Instructions R-38 vented 0.027 F 2,706 73.06
Above Grade Walls(sae Figure 1) U-Factor X Area UA
Instructions 0.056 124.15 2,217
R-211ntermediate
Floors U-Factor X Area UA
Instructions
No Floors above unconditioned spaces. -
Below Grade Walls(see Figure 1) U-Factor X Area UA
Instructions t 0.042
R-21 Interior �
Slab Below Grade(see Figure 1) F-Factor X Len th UA
Instructions --- 303
`. No Slab Below Grade in this project. 0.
�� ---
Slab on Grade(sae Figure 1) F-Factor X Length UA
Instructions -- ----- 0.360 2,706 974.16
R-10 Fully Insulated
Location of Ducts
Instructions Duct Leakage Coefficient
No Ducts F 1.00
Sum of UA 1374.93
Envelope Heat Load 64,622 Btu/Hour
Figure 1. Sum of uAX AT
Air Leakage Heat Load 19,230 Btu/Hour
volumeX 0.8XATX.018
AboveGnde Building Design Heat Load 83,852 Btu/Hour
Air Leakage-Envelope Heat Loss
Building and Duct Heat Load 83,852 Btu/Hour
Ducts in unconditioned space:Sum of Building Heat Loss X 1.10
Duds in conditioned space:Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 117,393 Btu/Hour
Building and Dud Heat Loss X 1.40 for Forced Air Furnace
Building and Dud Heat Loss X 1.25 for Heat Pump
(07101IJ3)
RECEIVED
`North Bay DEC 0 3 2020
513 1 L 20' Property Line 615 W. Alder Street
�S S
;
APPROVED
WSOW CGUMTY DCD PLANNING
40' SME PLAN REQUIRED TO E#E ON Ilft
SS S CHANGES SUBJET TO APPROVAL
5' Setback
PLANK NG:
SS S� 60 ALL SETBACKS 'RE MEASURED
'< FROM THE FURTHEST
PR ECTIQN OF THE BUILDING .
1 New Garage
\ ^ j 20 20 - 11��
o F2 I d 202,D - D 65q S8 Sew
o �D�2oZo • �� of New Nell
zow - ool-404 L V e�-tld--
Yb 6Gl
S� � S8
Power Line
v
• u I�e.n� AA-t- Cbrrec-t• ShrU rLt
s
5ite Plan i5cale:
- 5� a
Parcel #12232-10-CI2140 Site Address:
SIGN LTD DESIGN FOR: � Address: 5-11 Gronquist Rd � V � Page
5ELBY DE Allyn,
� Nast 24, 2020 1
7027 Killeen PI 5w Port Orchard,1Na 98361 Brandy Smith g Al lyn, J' `�
uuw,selbydesignitd.com 360-649-1826 01
Name Parcel# BLD#
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 1 of 2)
Per Mason County Code,Title 14, Chapter 14.48 a stormwater site plan is required whenever a building application is
made for residential development, or redevelopment',with more than 2,000 square feet of impervious surface 2.
'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development
including construction, installation or expansion of a building or other structure,and/or replacement of impervious surface that is not
part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment.
2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas,
concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the
natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces.
To Calculate Impervious Surfaces Please Complete This Table
Surface Type Length X Width = Area *All dimensions in feet
Buildings X =
X = Measurements for buildings are taken at the
perimeter of the farthest projections(example:
X = eaves/gutters)
X =
Driveways N, X =
X = Length of drive begins at the right of way
X =
Parking Areas I& =
X = Any paved, gravel or packed area per definition
X _ above table
Patios/Walks X =
X _ Any paved, gravel or packed area per definition
above table
X =
Others X =
X = If the total impervious area of the proposed site
X = development is greater than 2000 square feet a
Small Parcel Stormwater Site Plan is Required
Total Impervious Surface Area(sum of all areas)
If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below.
Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required.
X Owner/Agent/Contractor(circle one)Date:
If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read,acknowledge and sign
the information provided on page 2 of 2.
Page 1 of 2
I��" Q
Name z5 m L4' Parcel# 1.R A,89- 1 b• QZ 1 q4) BLD# 26 D — On PS E)9
�G Mason County
Department of Community Development
.. Arcel Stormwater Management Application/Worksheet (page 2 of 2)
Based Upon the information you have provided a Stormwater Site Plan IS Required for this develo ment activity.
RECEIVED
Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater
Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason CoygPiryv �it020
http//www.co.mason.wa m us/code/comissioners/index.htm UU 11., 3
Please follow the links to"Title 14,Chapter 14.48 Stormwater Management".
615 W. Alder Street
Regulated activities shall be conducted only after Mason County Public Works approves a Stormwater site plan
(Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document
entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist
you in preparing the necessary information and plans for Public Works to review and approve. Per Department of
Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in
their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health
information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval.
A design by a registered professional may be required for more complex sites.
*These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan
on the pages that begin with"Handout"
PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE
A) V/The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed
in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel.
B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the
system will be located as not to adversely affect any septic systems on this,or any other,parcel.
If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works
Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at:
Phone: 360-427-9670 ext 450
100 W. Public Works Dr
Shelton.WA 98584
If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or
any other,parcel.You may also wish to consult with the septic design professional involved with the project. Mason
County Division of Environmental Health can be reached at:
Phone: 360-427-9670 ext 400
415 N. 6th St-Bldg#8 lower level
Shelton.WA 98584
A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met
prior to a request for final inspection of the building permit.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the' formation provided is accurate and employees of Mason County are granted access to the above-
described property for revi and ins ion as may be required.X Owner/Agent/Contractor(circle one)Date: �-3 !,- Z�
Page 2 of 2
( % _ MASON COUNTY Mason County Permit Center Use:
I li COMMUNITY SERVICES
ADv 20 20 - 00I CQa
Building,Planning,Environmental Health,Community Health
615 W.Alder St.—Bldg.8,Shelton,Wa 98584 Date Rcvd
Phone:(360)427-9670 ext.352♦ Fax:(360)427-7798
Fee: $130.00
Request for Administrative Variance for
Reduction in the Required Setbacks
For administrative review, the minimum variance on a setback request is 5 feet from the side yard lot
lines and 10 feet for front and rear lot lines or any access easement. Request for further reduction
requires a standard variance. Setbacks are measured from the furthest projection of the structure,
including roof eaves `annd gutters.
Applicant/Owners: I_ k I V- %6w,l'k,
Mailing Address: ? Q •'2)0 X 1 2.I '
City: State: W A Zip: 98S2,L4
Telephone: ;1-452
Email: -6ra M L-k wa-2�YYt iZE . CO wl
If this reduction is tied to a building permit, please give permit case number.
sLD ZO ZO - o 1581
Parcel Number(s): D ' 2 y d Zoning
Site Address: �(��►,H_ i'TOU�� �G�IG�Ir��7�/ �� r♦ C IrbrlQUl`a I �G1
Requested setback variance:
Vr ft. ❑ Front ❑ Rear XSide n O e4 —
ft ❑ Front ❑ Rear ❑ Side
ft. ❑ Front ❑ Rear ❑ Side
ft ❑ Front ❑ Rear ❑ Side
Front Setbacks-From access easements and road right of ways. Minimum 10 feet.
Rear Setbacks-From the rear property line. Minimum 10 feet.
Side Setbacks-From the side property line. Minimum 5 feet except for certain shoreline designations.
An illustrated site plan is required.
Your site plan must show the following: north arrow, abutting street or easements, and set backs to all
property lines and existing buildings, slopes, surface water, wetlands, critical areas, septic, well and
driveway. Show all proposed new development.
FRONT AND OR REAR YARD REDUCTION REQUESTS:
For existing lots of record as of March 5, 2002;
You must meet one of the following:
1) One of the following exists on the lot(check all that apply):
❑ a) steep slopes, wetlands, or streams present;
❑ b) soils that restrict building or septic development;
❑ c) lot width at the front yard line of no more than 50 feet;
❑ d) lot size of no more than one-fourth acre;
❑ e) existing improvements of buildings, septic systems, and well areas.
SIDE YARD REDUCTION REQUESTS:
For existing lots of record as of March 5, 2002;
You must meet one of the following:
2) One of the following exists on the lot(check all that apply):
❑ a) steep slopes, wetlands, or streams present;
❑ b) soils that restrict building or septic development;
❑ c) lot width at the front yard line of no more than 50 feet;
❑ ) lot size of no more than one-half acre;
„e) existing improvements of buildings, septic systems, and well areas.
Explain how these circumstances preclude a reasonable development proposal from meeting the
setback standard fox Rural Residential 2.5, 5, 10, or 20 zones.
�V1U1.�.l,c�yl,�J Cam vn�►2.. l�v�� ,g.�!-b�.s £ �,��c�
Owner/Agent (please indicate) oeol 7-0
Date
Official Use Only
Approved by: Date
Denied by: Date
Reason for denial:
inWashington State Department of
Labor & Industries
Your jobsite for permit number 3650140E was inspected 9/2/2021 by CLAY MICHEAU.
The results of inspection are listed below:
Inspections:
ion Date IseciOn. t�� ael
„ R tI K Ins
9/2/2021 Miscellaneous,Other Approved Complete no breakers at this time
all on final
9/2/2021 Cover,Circuit,Walls & Ceiling Approved Complete
9/2/2021 Service,New,Underground,240V,10 Approved Complete 320 meter with 2 runs of
1-200A /0 4/0 2/0 with one 200
ramp service ATS
The following corrections were written on this inspection today.
The following corrections were marked completed on this inspection today.
You can view all inspection information on this permit online at Labor and Industries, electronic permit
and inspection system.Additional fees may be assessed and will not appear until they are processed by
our support team.