HomeMy WebLinkAboutBLD2021-00661 Final Remove Windows and Install Fireplace - BLD Permit / Conditions - 12/1/2021 Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg.8
Shelton,WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
BLD2021-00661 ADDITION OR REMODEL-
RESIDENTIAL
PROJECT DESCRIPTION: REMOVE WINDOWS (3)AND INSTALL LPG ISSUED: 05/14/2021
FIREPLACE
SITE ADDRESS: 221 E STONEBRIAR PL SHELTON EXPIRES: 11/10/2021
PARCEL: 321322390002
APPLICANT: MORALES ALVIN R&DARLINE H OWNER: MORALES ALVIN R&DARLINE H
221 E STONEBRIAR PL 221 E STONEBRIAR PL
SHELTON,WA98584 SHELTON,WA98584
480-459-8458
VALUATIONS: FEES: Paid Due
Project Valuation (BID, 6000.00 $6,000.00 State Fee-Residential $6.50 $0.00
ESTIMATION..) Technology Surcharge $7.06 $0.00
Building Permit Fee $156.00 $0.00
Plan Check Fee $80.00 $0.00
Mechanical Base Fee $30.00 $0.00
Mechanical Fees $87.00 $0.00
Total: $6,000.00 Totals : $366.56 $0.00
FIXTURES
(sty Mechanical Fixtures
1.0000 Gas Outlet(s) (1-5)
1.0000 Wood/Gas/Pellet Stove(s)
REQUIRED INSPECTIONS
Framing Inspection Gas Piping Inspection
Rough- Plumbing Inspection Fireplace Inspection
Mechanical Inspection BLD-Final Inspection
Insulation Inspection
Printed by:Genie McFarland on:05/14/2021 10:13 AM
Page 1 of 6
Mason County
I � Mason County - Division of Community Development
_ 615 W. Alder St. Bldg.8
Shelton,WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
ADDITION OR REMODEL- RESIDENTIAL BLD2021-00661
CONDITIONS
* All property lines shall be clearly identified at the time of foundation inspection.
CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING
DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All
construction must be in conformance with the international codes as amended and adopted by Mason County. Any
corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting
additional inspections.
* Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a
permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor
& Industries (L&I).
For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415-
4000.
* A permanent certificate, completed by the builder or registered design professional, shall be posted on a wall in the space
where the furnace is located, a utility room, or an approved location inside the building. When located on the elctrical panel,
the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect labek, or toher reqyired
Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab,
basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the
solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate
shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service
water heating equipment, duct leakage rates including test conditions as specified in WSEC Section R401.3 & R402.4.1.2,
and air leakage results if a blower door test was conducted.
Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air
changes per hour when tested with a blower door in accordanve with IECC/.WSEC Section R402.4.1.2.
The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution
panel. Air leakage testing is not required for additions less than 500 square feet. Reference IECC/WSEC R402.4.1.2.
Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2015 Certificate"and are
available in '/or'/2 sheets. The Mason County Permit Center will also have some available.
* Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and
MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either
private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an
existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance
and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting
from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any
construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that
office to review future planned work which may affect your project.
* WIND LOADS-Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind
speed for Mason County is 85 MPH.
* The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the
approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule,
minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being
performed or approvals granted.
Printed by:Genie Mcfarland on:05/14/2021 10:13 AM
Page 2 of 6
Mason County
Mason County - Division of Community Development
615 W. Alder St. Bldg.8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
ADDITION OR REMODEL- RESIDENTIAL BLD2021-00661
Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the
structure.
* REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable
provisions of the current code and the manufacturer's installation instructions.
A drip edge shall be provided at eaves and gables of shingle roofs.
* Adopted IECC/Washington State Energy Code Compliance has been approved as follows:
Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window(Max U-
Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation
R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10.
* Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries,
Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an
unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either
the homeowner, agent for the owner or a registered contractor according to WA state law.
* Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer
specifications and in accordance with IRC Section R315.
Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level
of the dwelling.
EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of
fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or
created.
* The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not
allowed without the approval of the Mason County Fire Marshal.
* A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit
application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the
responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that
Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement
of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater
Management Application/Worksheet the document entitled"Managing Storm Drainage on Small Lots, The Small Parcel
Stormwater Site Plan"constitutes an approved plan based on the criteria listed on the application/worksheet. If the
development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other,
parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final
inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater
management system have been installed as approved on the stormwater site plan.
Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and
MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either
private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an
existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance
and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting
from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any
construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that
office to review future planned work which may affect your project.
Printed by:Genie Mcfarland on:05/14/2021 10:13 AM
Page 3 of 6
Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg.8
Shelton,WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
ADDITION OR REMODEL- RESIDENTIAL BLD2021-00661
The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more
than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards
for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to
another fire apparatus access road which connects to a county maintained public road.
* Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC
R403, applicable sections of the IRC, and IMC.
Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the
purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including
infiltration and ventilation. Design calculations shall be available for inspection during inspection.
Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct
systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other
approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be
marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used
with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-
sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings
shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B
and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm)
and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint.
Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation
instructions.
Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be
insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit
documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building
Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website
titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not
required if the air handler and all ducts are located within the heated space.
* All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and
plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee
schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections
being performed or approvals granted.
* All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building
Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration.
Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No
more than one extension may be granted.
* A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance
with IECC/WSEC Section R404.1.
Printed by:Genie Mcfarland on:05/14/2021 10:13 AM
Page 4 of 6
Mason County
Mason County - Division of Community Development
615 W. Alder St. Bldg.8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
ADDITION OR REMODEL- RESIDENTIAL BLD2021-00661
* OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit
revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or
contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained
permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County
access to the above described property and structure(s)for review and inspection. This permit/application becomes null &
void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of
180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT
APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
* The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility
of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked
"APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is
responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of approved documents will result in failure of required building inspections.
* When parcel development requires direct access to state road(s), a Road Access Permit or Approval must be granted and
approved by the Washington State Department of Transportation. For more information contact Washington State
Department of Transportation, at(206)357-2620, ext. 630.
* The foundation/footing must be placed on undisturbed, firm-native soil.
* By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your
"Approved Site Plan"to ensure these structures meet the setback conditions listed.
* When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by
the Mason County Department of Public Works. For more information contact Public Works, at(360)427-9670, ext. 450 or
100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the
access permit from Public Works has been finaled and approved.
* Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site
plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed.
* Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly
corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of
pressure treated material.
* Before renovating or remodeling activities in pre-1978 residential buildings or child occupied facilities and to ensure your
compliance with applicable Washington lead regulations, contact the WA State Department of Commerce Lead Paint
Program at; (360)586-5323 or email Ibpinfo@commerce.wa.gov. Visit www.commerce.wa.gov/lead for further information.
* All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as
adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted
classification. Any non-approved change of use or occupancy would result in permit revocation.
* All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or
any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction.
* Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance
with Mason County Title 14.28 and 14.17.
* Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate
building permit and approval prior to construction of the retaining wall.
* Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather,
garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of
3000 psi (IRC Table R402.2).
Printed by:Genie Mcfarland on:05/14/2021 10:13 AM
Page 5 of 6
} Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg.8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
ADDITION OR REMODEL- RESIDENTIAL BLD2021-00661
All building permits shall have a final inspection performed and approved by Mason County Building Department prior to
permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property
records on file with Mason County as being non-compliant with Mason County ordinances and building regulations.
All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor
increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way.
I hereby certify that I have read and examined this application and know the same to be true and correct.
All provisions of Laws and Ordinances governing this type of work will be complied with whether
specified herein or not. The granting of a permit does not presume to give authority to violate or cancel
the provisions of any other state/local law regulating construction or the performance of construction.
Issued By:
F I
Contractor or Authorized Agent Date: Zr 'Y
"/-'Z_
Printed by:Genie Mcfarland on:05/14/2021 10:13 AM
Page 6 of 6
v�sk Lu F �iV.rR G- �l, OG RI . �� ► q �nl� .
C-NOP
s R-t�g orzs
ICAL
i p�Date .IyY frrFe rr-ua
%NUFACTURE-1) HOME
tzs s oat_ $ .L-L1
Briar-L ay
Date- 1Y
!�'aLs
BY � By PTPF-DEPA NT
i<c�c�rtgaIIoat
BY
PRAMNG F oFCKS
Data BY
_. PR.0PANE TkKS
PLUMBINGDal- ey
�
.,kwc OVER
Cal* By Gam 13y FY'Pt:
f DP4�r.LL Dal-- Bp
Date By
tnt E#r a Waif Dv�a
`Dade m ay
_. By
CD '�Lifle Fire Se orafiic>ct [ -i i C�1 C fid
C
m BY
s Pass Or Requee Impact
CD TYPO Of InSP. Fail Data Date � Do ey
rk37 -its
.� ac w � wptiL
l
3
n
3
D
3 - I I � � •
1
7
t
1
ti
MASON COUNTY 615 W.Alder St.Bldg 8,SHELTON,WA 98584
l COMMUNITY
SERVICES SHELTON:360-427-9670,EXT 352
lVl V 1 i BELFAIR:360-275-4467,EXT 352
Building,Planning,Environmental liealtlt Cammun ity Neitu,
ELMA:360-482-5269,EXT 352
INSPECTION CARD AND CERTIFICATE OF OCCUPANCY** www.co.mason.wa.us
To schedule an inspection call or visit http://www.co.mason.wa.us/community-services/bld-inspection.php
Permit Number BLD2021-00661 Date Issued 05/14/2021 Issued By
Project REMOVE WINDOWS(3)AND INSTALL LPG FIREPLACE
Site Address 221 E STONEBRIAR PL
Applicant MORALES ALVIN R&DARLINE H
Contractor
Contractor Phone
Primary Code 2015 IBC,IRC,IFC,IEC,IMC,&
UPC Type
Permit Type ADDITION OR REMODEL- Occupancy
RESIDENTIAL P Y
-APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS.
-DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED.
-THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION,FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY.
-ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION.
-OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION.
**THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED.**
PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET
Public Works Access/Driveway Other
Health Septic Well
Deptartment
Planning Site Inspection
Department
Fire Marshall Fire Apparatus Access Fire Sprinkler
Auto Fire Alarm Hood and Duct
Other Final
Building
Department Building Official: Community Services Designee
Concrete Setbacks Slab
Footing Perimeter Point load Footing
Footing Interior Footing Decks/Porches
Foundation Stem Walls Other
Rough-In Groundwork Plumbing Framing
Groundwork Mechanical Plumbing
Groundwork Gas Pipe Mechanical
Gas Piping Shear Wall Nailing
Underfloor
Other
Insulation Slab Ceiling
Floor Vaulted Ceiling
Walls Vapor Barrier
Other
Wallboard Interior Wall Brace Panels
Nailing Fire Walls
Other
Final Building
Manufactured Setbacks
Setup
Home
Concrete Foot/Runners Final
Other
I
i
a 3'
i
w �r+
l„
L6
409
41
(1AtMaTN2 tBF�YLa t� "f r0+� tl�S i d!tjG14J�f�G'�Lu .YC
t. IN,5Rl4T?vp rt)", L,,j L ('eiA
r+crass aLra
2tE kR �
_1 e f2 Ici rcfav l�ld .C�lkS LJ���
i
S 7-1 /r/ dr.= I-o oc iP,
CerPP x��n SM a7-
.-- 7 11�
i � I
S I a
t;
T
RECEIVED
MAY - 4 ?n3'
615 W. Alder Street
EXTRA UNMARKED SET
OF PLANS, NOT FOR
CONSTRUCTION
3.2.2 Planning the installation
This Mendota Fireplace must be installed and serviced by a qualified installer,service agency,or the gas supplier.
When planning on appliance installation, it is necessary to determine the following information before installing:
• Where the appliance is to be installed.
• The vent system configuration to be used.
• Gas supply piping.
• Electrical Wiring.
• Framing and finishing details.
• Hearth Protection Pad Requirements.
• Whether accessories such as a ceiling fan are desired.
3.2.2.1 Selecting Appliance Location
When selecting a location for your appliance,it is important to consider the required clearances to walls.
I"MINIMUM CLEARANCE 0
1�
ON SIDES OF VENT PIPES
--21 5/8�
-
+� R \ I1 3/8 FRAMING
` DEPIH
1 � \
I/2 FACING \
45" 36 I/4
IT
s�
12 \
MINIMUM FRAMING DIMENSIONS \
I
WIDTH=36-1/4" HEIGHT=31-7-16" DEPTH=15-1/8"
Figure 3-11 FLAT WALL LOCATION
I
Figure 3-12 CORNER INSTALLATION
WARNING
FIRE RISK- ODOR RISK
• Install appliance on hard metal or wood surfaces extending full width and depth of this fireplace.
• An R-1 Rated Hearth Protection Pad [1-1/2" Thick Maximum] and 12" deep is required unless this fireplace is
elevated. For every 1" this fireplace is elevated, you may reduce the hearth pad depth by 2". If this fireplace is
elevated 6" or higher no hearth protection pad is required.
• Do NOT install this fireplace directly on carpeting, vinyl or any combustible material other than wood.
Construct chase to all clearance specifications in manual.
• Locate and install appliance to all clearance specifications in manual.
85-03-01113 DXV35DT4 Page 15
3.2.3 Dimensions and Technical Details
3.2.3.1 DXV351DT4 Fireplace Ratings Information
This Mendota Fireplace can be installed directly on top of a metal,masonry or wood structural surface.
ELECTRICAL REQUIREMENTS: 120 Volts AC, 1.5 Amps(minimum line voltage allowed 110 Volts AC) REQUIRED
GAS SUPPLY PRESSURE: NAT.GAS:7"W.C. [5.0"W.C. MIN., 11"W.C. MAX.]
L.P. GAS: 11"W.C. [11"W.C. MIN., 13"W.C. MAX.]
LP GAS CONVERSION KIT:This Fireplace comes configured for use with Natural Gas. To convert the Fireplace for use with LP
Gas, install: LP GAS CONVERSION KIT#HA-78-00179.
GAS INPUT RATES High Fire Low Fire
BTU .......................... NAT. GAS 33,000 10,000
BTU H .......................... L.P. GAS 33,000 13,000
ORIFICE SIZES............[0-2000ft(610 m)]: REAR BURNER: #44 NG[3/64" L.P.]—FRONT BURNER:#49 NG[3/64"]
P.4 FIREPLACE EFFICIENCY..........76.35%
FLUE VENTING ............COAXIAL RIGID-4" DIAMETER EXHAUST&6-5/8" DIAMETER AIR INLET AND APPROVED VENT CAPS
All UL Listed Coaxial Rigid 4"X6-5/8"Vent pipe components and vent caps are approved for use. Do not mix components of
different brands or series.Always use the same brand and series components throughout the entire vent system.
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION
UNIT TO FLOOR Oin. (Omm) GLASS FRAME EDGE TO ADJACENT SIDEWALL 12in. (305 mm)
UNIT TO ENCLOSURE SIDEWALL 1/2in. (13mm) VENT PIPE TOP TO COMBUSTIBLES 2in. (51mm)
UNIT TO ENCLOSURE BACK WALL 1/2in. (13mm) VENT PIPE SIDES TO COMBUSTIBLES tin. (25mm)
UNIT BOTTOM TO ENCLOSURE CEILING 53-3/8 in. (136 cm) VENT PIPE BOTTOM TO COMBUSTIBLES tin. (25mm)
UNIT BOTTOM TO ROOM CEILING 72 in. (1829 mm)
DISTANCE TO 8" MANTLE ABOVE TOP CONVECTION AIR DISCHARGE OPENING 14 in. (356 mm)
MINIMUM COMBUSTIBLE ROUGH FRAMING DIMENSIONS
WIDTH=36-1/4" (920 mm) HEIGHT=31-7/16" (799 mm) DEPTH= 15-1/8" (384 mm)
NET WEIGHT................185 lbs. (Team Lift recommended)
BARRIER SCREEN:A barrier screen that has been certified for use with this Fireplace must be installed on the Fireplace when it
is in use.The barrier screen will prevent accidental contact with the glass door face,which could result in a severe burn.
SAFETY:AGA certified,electronic ignition IPI system activated with thermostatic remote control.
CERTIFIED TO:ANSI Z21.88—2016
This Mendota Gas Fireplace has been tested and certified by:
Intertek Testing Services,8431 Murphy Drive, Middleton,WI 53562\
ICBO#AA647-4
85-03-01113 DXV35DT4 Page 16
3.2.3.2 Fireplace Features
EXTERNAL DIMENSIONS:36-1/4 Wide X 31-7/16" High X 15-5/8" Deep
MINIMUM FRAMING DIMENSIONS:36-1/4"WIDE x 31-7/16" HIGH X 15-1/8" DEEP
GLASS SIZE: NeoCeram Glass with non-reflective coating. Visible Glass measures 28-3/8"X 16-1/16".
MANTEL ALLOWANCE: 8" Deep Mantel at 14"Above Top Convection Opening(41" up from base of Unit)
VENT SYSTEM ALLOWANCE:Top Vent Only. 12"Vertical Minimum with 6"max horizontal. 55 feet Vertical Maximum.4"
exhaust and 6-5/8"combustion air intake coaxial vent pipe required. 12' maximum horizontal run allowed with 4' minimum
vertical starter section.
VENT DAMPER ADJUSTMENT AVAILABLE:There is one exhaust vent damper included in this unit and located in the top
convection chamber at the center.
CONTROLS: IPI Electronic Ignition System with AC Primary Power and DC Backup Power.Accent light and Blowers operate on AC
Power only.Thermostatic Remote-Control Transmitter with Smart Thermostat Mode.
BLOWER SYSTEM: 190 CFM Dual Blower System. 120VAC,2Amps. Dedicated Hot Power only. No switches, Fan Speed Controls
or Light Dimmers are allowed in same circuit.
Accent Light System:Accent Light System Included. Light can be turned on or off or dimmed using dimmer mounted behind
lower grill.Accent Light can also be turned on or off using Remote Control Transmitter.
BURNER SYSTEM: Dual 304 Stainless Steel Tubular burners.
BURNER AIR SHUTTER SYSTEMS: Externally controllable Rear Burner air shutter and Internal rotary Front Burner air shutter.
LOG SET:9-piece, Premium Definition Log Set with Extreme glow and realism ember bed.
REFRACTORY PANELS: High Detail Red Clinker Fiber Brick Panels included. Brick Panels required for operation.
NATURAL GAS INFORMATION: Factory equipped for Natural Gas.4.5"WC Minimum inlet pressure required. For NG
applications, Front Burner Orifice Size is#49 and the Rear Burner Orifice Size is#44.
LPG INFORMATION: LP conversion kit#HA-30-00507 is required. 12"WC Minimum inlet pressure required. For the DXV35 DT4
LPG application, both front are rear burner orifices are to be drill size 3/64". For higher altitude,adjustment to orifice size may
be necessary.
85-03-01113 DXV35DT4 Page 17
3.2.3.3 Fireplace Dimensions and Clearances ,
I'MINIMUM CLEARANCE
ON SIDES Of VENT PIPES �� ryb
71 5/8
I+ t
Ts 11811 3/8
' a ROUGH
FRAMING
DEPTH
1/2 FACING
45, —36 1/4
17'
Ir
MINIMUM FRAMING DIMENSIONS
WIDTH=36-1/4" HEIGHT=31-7-16" DEPTH=15-1/8"
Figure 3-13
Figure 3-14
41"to it L
TOP AIR GAP Combustible
A Monlel
7 Cleomnce �--6 0.
Min.AbOvO ' 1
vent.
14"to it 4i'
Combustible noon To Ir
d 8'COMBUSTIBLE r)(6.5/S
Monte] MANTEL Vent
53-3/8'NAN.
FO
o CHASE
C CEILING
O -
- a �U � 47'5 Q O 7T I/6
(j O LL nOOR TO fIO DR
LL O a i 1OP OF TOP To VENT
._:.. -
C4.2(5 w 1 1/r.. AIR GAP. CENTER
Hesghl Pac
Hegllt
4J t` 1
36 1/4" 1/7 THICK 17 F-15.1/8'Nin
R-I RATED —'1 frolring Depfli
Screw Hd to Screw Hd UNDERLAYNENT
Figure 3-15 Figure 3-16
A wall, perpendicular and in front of this appliance's glass door face must be at least 12" away from the side edges of
the glass frame.
A wall at a 45' angle to the front face and starting at the Side Edge of the Front Face of this appliance is allowed.
Projections behind this 45' angle edge(shaded area) are allowed.
Caution:The distance from floor level to the centerline of the vent cap is based on Simpson DuraVent GS components.
If using vent components of another brand, do not assume that the measurement given here is applicable.Verify the
distance to the centerline of vent cap by measuring the components you are using.
Note: For every 1"this fireplace is raised off the floor,the non-combustible hearth protection pad may be reduced by
2". If this fireplace is raised more than 6" off the floor, no hearth protection pad is required. See
fl:id R,-q ll fcm,:lli and
85-03-01113 DXV35DT4 Page 18
3.2.3.4 Rough Framing Dimensions
The rough framing dimensions given are the
minimum allowed framing dimensions. Be sure Minimum Required Rough Framing Dimensions
when planning the framing of the unit that DESCRIPTION DIMENSION
adequate paths to route the gas and electrical are (INCHES)
available on both sides of the unit. A WIDTH 36-1/4"
B HEIGHT 31-7/16"
SPECIAL FRAMING NOTE: C DEPTH 15-1/8"
If the fireplace is to be recessed in a cavity deeper E FINISH MATERIAL THICKNESS Varies
than 15-1/8",all framing and finishing materials F UNIT BASE TO ENCLOSURE 53-5/8"
protruding past the front face of this fireplace CEILING
GLASS FRAME EDGE TO SIDE 12"
must be of the NON-COMBUSTIBLE variety. G WALL
H UNIT BASE TO 8" MANTEL 41"
41"to 8"
TOP AIR GAP Combustible �--
\ Mantel
TClecrorce �8 I
Min.Above
f---— vent.
to 8"
Combustible
Mantel 41
.O FLOOR TO 17
g 8"CO+tBU5T18LE = 4x6.5/8"
`.0 tsANTEI Wnt
01 53
t o U E I TO
kS O , � O 2 CHASE
S O a a I I CEIUNG
N Q W
7
FLOOR TO
FLOOR FLOOR
T TOP or TOP TO VENT
I I(T Max. AIR GAP. CENTER
36 1/4" Huth Poc
Screw Hal to Screw Hal Height
MINIMUM FRAMING DIMENSIONS 1 _
WIDTH=36-1/4" HEIGHT=31-7-16" DEPTH= 15-1/8" 1/7'THICK �IS-I/f vin
R-1 RAZED 1 Fron-ing Depth
UNDERLAYMEnT
Figure 3-17 Figure 3-18
If the mantel is constructed of non combustible materials,it may be placed at any distance above the top air gap.
Caution: Materials made of porous stones or sedimentary rocks may crack due to expansion of the material if placed around this
appliance. Use suitable materials which are crack resistant and high temperature resistant.
85-03-01113 DXV35DT4 Page 19
3.2.3.5 Constructing the Appliance Chase
A chase is a vertical box-like structure built to enclose this fireplace and its vent system. Vertical vents that run on the outside
of a building may be,but are not required to be,installed inside a chase.
Construction of the chase may vary with the type of building.These instructions are not substitutes for the requirements of
local building codes. Local building codes MUST be adhered to.
Chases should be constructed in the manner of all outside walls of the home to prevent cold air drafting problems. The chase
should not break the outside building envelope in any manner.
Wall,ceiling, base plate and cantilever floor of the chase should be insulated. Vapor and air infiltration barriers should be
installed in the chase as per regional codes for the rest of the home.Additionally,in regions where cold air infiltration may be
an issue,the inside surfaces of the chase may be sheet rocked and taped for maximum air tightness.
To further prevent drafts,the fire stops should be caulked with high temperature caulk to seal the gaps. Gas line holes and
other openings should be caulked with high temp caulk or stuffed with unfaced insulation. If the appliance is being installed on
a cement slab,a layer of plywood may be placed underneath this fireplace to prevent conducting cold up into the room
WALL TI--
-
-- 12" SECTION
i- -
47_ i
r
r0 A r
Figure 3-19 Floor to Vent Cap Center Dimension
85-03-01113 DXV35DT4 Page 20
46
3.2.4 Clearance Requirements
3.2.4.1 Clearance from Appliance Body and Vent
—— 2"
Mari. 90* L
-- 12" SECTION {
i I
2'2 -B- r 1 t
-A- r
a
CLEARANCES:
ZERO TO SIDES
1cRO TO FLOOR
A.2 I/7'FROM IOP
B 1"HORIiONTAL TO VENT PIP:-
Figure 3-20 CLEARANCES TO BODY& VENT Figure 3-21 CLEARANCES TO VENT
The required clearances are depicted in these diagrams.
1. Minimum Clearance from fireplace body sides to combustibles is zero.
2. Minimum Clearance from fireplace top surface to combustibles is 2-1/2"or zero from top edge of top triangle
standoffs.
3. Minimum Clearance from vertical vent pipe sides to combustibles is 1".
4. Minimum Clearance below horizontal vent pipe or components is 1".
5. Minimum Clearance above elbows and horizontal vent pipe and components is 2".
85-03-01113 DXV35DT4 Page 21
3.2.4.2 Hearth Pad Requirement
A non-combustible hearth protector with a thermal insulation rating of R-1 is required when installing this fireplace directly on
the floor and must extend a minimum of 12"in front of this fireplace.To build an R-1 rated hearth protection pad,begin by
laying down a%'thick layer of an R-1 rated Mineral board(see ,21.6.3 Suitable Finishing Materials R-Rating )and then add a
1"thick top layer of noncombustible material such as stone,granite,marble or the like.
For every 1" the fireplace is raised off the floor, the depth of the required hearth protector may be reduced
by 2". If fireplace is raised off the floor 6" or more, no hearth protector is required for fire protection.
Caution: The fireplace creates localized heat and causes thermal expansion of adjacently installed flooring
and wall materials. Vinyl floors and floating Engineered wood floors may warp if installed in front of this
unit even when this fireplace is raised 6" or more due to local heating up of the floor materials. Never use
vinyl or Engineered wood flooring in the hearth pad area in front of this fireplace unless you plan to raise
this unit 12" or more above the floor level.
Caution: Modern carpets use polypropylene, nylon or polyester fibers in the upper visible layer. These fibers
when exposed to radiant heat can curl and stiffen. It is not possible to prevent radiation effects to the
carpet fibers even when this unit is raised high. Avoid installing carpets in the hearth pad area in front of
this Fireplace unless this fireplace is raised at least 12 inches above the carpet level.
This fireplace may be installed in an elevated position by created an elevated deck and an appropriate framed enclosure. NOTE:
This fireplace may be elevated but MUST allow a minimum of 72"distance between this fireplace's floor level and the ceiling of
the room.
_'-- �-90' L - I
T Clearonce w—a Min.Above I
Vent.
1
-- -----
a 1' __
"----- FLOOR TO 12'
W COMBUSTIBLE 4-M-5111
MANTEL - Vent
TO
CHASE
CEILING
7- 47-1/Er
FLOOR TO FLOOR
TOP OF TOP TO VENT
1 1/2'Max.
AIR GAP. CENTER
11 % Hccrlh Pad
Height
164
R- THICK
R- 1 RATED Is ua Min
RI RATED 12 rrorring Depth
HEARTH PAD LINDERLAYMENT
Figure 3-22 HEARTH PROTECTON PAD
85-03-01113 DXV35DT4 Page 22
Y -s•
E��YL�u >J
1 2r:--)\&C3V ao�2�y M�u�n w�,�pows
�, I�k�OVE SffET'�uCic F(tvM /NS1n� G✓��DUt.J �`-��S
3 Rove w,rjrowsn {?�zYuc�
rtilSrh c. u to lh-c S rLk
¢ X TtYUc� o W en_ n16W
S S7uh S
/N ] ilYt (�
7 1
tu7iNl�cW �c/� ��s
(d%� S LIB L SI D/N(r /� AWrZ H EX D/tip f�RP/Y t
w►t'j"wS use
�'. • � MASON COUNTY COMMUNITY SERVICES Permit NoOL
a -Do La
PERMIT ASSISTANCE CENTER:
.BUILDING•PLANNING-PUBLIC HEALTH-FIRE MARSHAL RECEIVED
615 W.Alder Street,Shelton,WA 98584
Phone Shelton:(360)4 ert. •Fax:(360)427-7798 Phone BUILDING
Belfair.(360)275-4467 5-4467•Phone Phone Dina:(360)482-5269
MAY - 4 2071
BUILDING PERMIT APPLICATION
PROPERTY OWNER T WORMATION: CONTRACTOR r Street
NAME:M 0 k A/L t3 4 L NAME:
MAILING ADDRESS: LZ 1 E STONFRRf 419- PL MAILING ADDRESS:
CITY: 5 f4CL:WtJ STATE:WA ZIP:g g 58k4 CITY: STATE: ZIP:
PHONE#1: RO- 5L61- - gI/,s� PHONE: CELL:
PHONE#2: EMAIL:
EMAIL: C. (�i( (��V- Q 1. CyM L&T REG# EXP.
PRIMARY CONTACT: OWNER 9- CONTRACTOR❑ OTHER❑
NAME L O LES EMAIL &4C(AWgR;J rMa6J* GDI%•
MAILING DDRESS ZZt C TUN 044(L CITY !QNf'LTon! STATE w ft-ZIP_ y
AMPE o CELL
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number)1 Z/3-1 2J g00d Z ZONING
LEGAL DESCRIPTION(Abbrcviatcd)-<WA4 )* LOT. Z a�SE-rZ 2-,53 FIRE DISTRICT
SITE ADDRESS i aN BQ/*Q IL CITY 5h-0-7 7/`) A
DIRECTIONS TO SITE ADDRESS Al 6A1 t,IGd l! . b� ��L dA S�>y����►5
IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NO;& SNOW LOAD:_psf
IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (check all that apply):
SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑
TYPE OF WORK: NEW❑ ADDITION❑ ALTERATION❑ REPAIR❑ OTHER K Adif GtTe-
USE OF STRUCTURE(Reridmve,Gm-age,Commercial Bldg,Etc) R1M1r>0kMA-L—
IS USE: PRIMARY SEASONAL❑ NUMBER OF BEDROOMS_NUMBER OF BATHROOMS�A
HEATED STRUCTURE? YES(Whale 81dg)& YES(Pawv of Bldg)❑ NO❑
DESCRIBE WORK/AIS7ALL
SOUARE FOOTAGE:(Pr Pnced) ^f�
1ST FLOOR sq.ft. 2ND FLOOR sq.tL 3RD FLOOR sq.ft. BASEMENT sq.it.
DECK sq.ft. COVERED DECK sq.ft. STORAGE sq.tL OTHER sq.fL
GARAGE sq.ft. Attached❑ Detached❑ CARPORT sq.ft. Attached❑ Detached❑
MANUFACTURED HOME INFORMATION: �1/'T'/!] *4 COPIES OF THE FLOOR PLAN REQUIRED*
MAKE MODEL YEAR LENGTH
WIDTH BEDROOMS BATHS SERIAL NUMBER
ENVIRONMENTAL HEALTH: ivo
SEWAGE/SEWER SOURCE: SEPTIC❑ SEWER❑ / NEW❑ EXISTINGX
PLUMBING IN STRUCTURE? YES❑ NO❑ If yes,attach completed Water.Adequacy Farm
PERIMETERTOUNDATION DRAINS PROPOSED? YES❑ NO[] EXISTING SQ.FT. ?
EXISTING BEDROOMS_ PROPOSED BEDROOMS 4b TOTAL BEDROOMS 3
OWNER acknowledges that submission of inaccurate Information may result in a stop work order or permit revocation.Acknowledgement of such is by
signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have
obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project The owner or legal
representative,represents that the Information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180
days or If construction work is suspended for a period of 18C days.
PROOF OF CONTINUATIO F WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERM PLICATION 18 D OF MOREL CAUSE THE APPLICATION TO BE EXPIRED.(MASON
COU ODE 14.08.42)
Signature of )VONER(Must be signed by the OWNER I Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
PUBLIC HEALTH
MASON COUNTY COMMUNITY SERVICES Permit No: ll g 'OMP I
PERMIT ASSISTANCE CENTER: BUILMA
•BUILDING •PLANNING •FIRE MARSHAL C
615 W. Alder St- Shelton, WA 98584
www.co.mason.wa.us RECEIVED
Phone Shelton:(360)427-9670 ext. 352• Fax:(360)427-7798
• Phone Belfair:(360)275-4467• Phone E/ma: (360)482-5269 MAY _ 4
2021
PLUMBING & MECHANICAL PERMIT APPy TION
Adder Streat
OWNER INFORMATION• ,1 CONTRACTOR INFORMATION:
NAME: M 0!Z "S �L V I � NAME:
MAILING ADDRESS: a-a--f e -r0tJ,--90/1�-P L MAILING ADDRESS:
CITY: STATE:WA-- ZIP:=`/ CITY: STATE: ZIP:
I"PHONE: AD -ie S - 9 y: $ PHONE: CELL:
2nd PHONE: �/8o VS11- a Y Io<Y EMAIL :
EMAIL: &oil R(@ e_0t r~th ta b i•co"A L&I REG# EXP.
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number): �p2 3 aZ -2- 3 - d U O Z- Zoning:
LEGAL DESCRIPTION(Abbreviated): S W A)W i I_O 1 Z 2,2-.53
SITE ADDRESS: ;2 of 1 F P- CITY:
DIRECTIONS TO SITE ADDRESS:__,,AZ ®aj 22wr V deA (e -- N A-Q,",se tj L o o Sloie pl tI
LA-S - Jo u,S f a 0 h-4-T
TYPE OF JOB:
NEW ADD ALT REPAIR OTHER USE OF BUILDING #0 M E
LOCATION OF FIXTURES/UNITS—1 sT FLOOR R 2TrD FLOOR BASEMENT GARAGE OTHER
PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS /
Type of Fixture No. of Fixtures Fees Fuel Type:Electric LPG Natural Gas Ductless_
Toilets Type of Unit No.of Units Fees
Bathroom Sink Furnace
Bath Tubs Heat Pump
Showers Spot Vent Fan
Water Heater Propane Tank
Clothes Washer Gas Outlets
Kitchen Sinks Wood/Gas/Pellet Stove
—
Dishwasher- Kitchen Exhaust Hood
Hose bibs Dryer Vent
Other Solar Panel
Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is
by signature below. I declare that I am the owner,owners legal representative,or contractor. I further declare that I am entitled to receive this
permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of
interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of
Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void
if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF
OF CONTINUATION OFTHIS PERMIT IS By MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS
WILL INVALIDATE T .APPLICATION.
Signa ure of Owner Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
Rev: 1i27/2016 JBN