HomeMy WebLinkAboutCOM2020-00036 ReRoof - COM Permit / Conditions - 3/12/2020 Mason County Mason County - Division of Community Development 615 W.Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us COM2020-00036 REROOF- COMMERCIAL PROJECT DESCRIPTION: RE-ROOF CENTURYLINK SWITCHING ISSUED: 03/12/2020 STATION: CLASS A SHINGLES WILL BE INSTALLED, ROOF PITCH IS 6/12 NEW BATT INSULATION TO BE INSTALLED BETWEEN 2 X 8 EXPIRES: 09/08/2020 STICK FRAME RAFTER, NEW RIDGE VENT SITE ADDRESS: 23650 NE STATE ROUTE 3 BELFAIR PARCEL: 123294300200 APPLICANT: CENTURYLINK OWNER: CENTURYLINK 2703 N MADISON AVE 2703 N MADISON AVE TACOMA,WA98407 TACOMA,WA98407 206.345.7953 CONTRACTOR: V&R ROOFING 2920 S CUSHMAN AVE TACOMA,WA98409 253.328.5678 GENERAL CONTRACTOR'S LICENSE: V&R ROOFING License: VRSHESM973KM 2920 S CUSHMAN AVE Expires: 05/15/2021 TACOMA,WA98409 253.328.5678 FEES: Paid Due State Fee-Commercial $25.00 $0.00 Re-Roof Commercial Base Fee $190.00 $0.00 Technology Flat Convenience $5.00 $0.00 Fee Totals : $220.00 $0.00 REQUIRED INSPECTIONS Insulation Inspection Re-Roof-Final Inspection CONDITIONS Printed by:Ariane Paysse on:03/12/2020 11:10 AM Page 1 of 2 Mason County j Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us REROOF- COMMERCIAL COM2020-00036 " Insulation: IECC 101.4.3 exception#5 Roofs without insulation in the cavity and where the sheathing or insulation is exposed during re-roofing shall be insulated either above or below the sheathing. Insulation is not required for roofs where neither the sheathing nor the insulation is exposed. (Reference IECC/WSEC R101.4.3) * OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. * Roof Covering: IRC section R905 & 907 Selected roof covering must be installed in accordance with manufacturer's specifications and IRC requirements.A drip edge shall be provided at eaves and gables of shingle roofs. * Roof Slope: IRC section R904.1 Roof slope must be indicated to ensure selected roof covering is allowed on designed pitch. * Attic Ventilation: IRC section R806 Enclosed attic and rafter area shall be supplied with cross-ventilation. The net area shall not be less than 1/150 of the area of the space to be ventilated. If 50% and not more than 80%of the ventilating area is provided from the upper portion of the space to be ventilated,then 1/300 is allowed. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provision of any other tate/local law regulating construction or the performance of construction. Issued By: Contractor or Authorized Agent: �� G Date: 3 2 202U Printed by:Ariane Paysse on:03/12/2020 11:10 AM Page 2 of 2 t Z Z D m -� -� m n 9 ;u rm- -i — z 0 0 O O ;u ;u _r o n QO m N oO Z Z ;u - N CA ;o C CO m O o 0 T G Z Z O Cu '� CD w 2 O> z m '0 Cn co w m o 3 Z 0 p - 01 o M Z � m Cl)m 0 m m cn CO) 0 0 mEL Cl) D rn � No w m . m cn Z 0 m o CO 0) � o CO) 3 m� C _ rn C M Fn O N a) ti n z z Z 0 � O am m m �D2m W c � O � 0Q .n�CD 0 � �Z ;7 o cn N� �m z =m�m m D _ �T Z - v cD 00 m � cyl F 00 oZ�m —I— z *OzC CD w � m� � Co p — D _ mz cnr � n < � � � ri m m F_ n > Zr� 2 D 2 = � DO� °�° O O pm0 N Mz m —i o0 m c PI) o =O m—z w w zcn.. WpoNrnn Ul :-4 X m con � N � co �� �Zcn �mD r malaw-WMVISTA & AR TECHNICAL PRODUCT . • EEP ;LCPc_ RESIDENTIAL LAMINATE SKU:251 252 WIDTH s'/e" LENGTH s'!e" MAR � °� ��Z� 131/" 39" 337 mm 0.99 m 615 W. Aid r EXPOSURE GRANULE ADHESION N EX® POLYMER M O D I F I�D rr �- 145311 /a Ty0ica�e9ns LAMINATED ARCHITECTURAL !� - SHINGLESISQUARE SQUARESIPALLET SHINGLES 66 16 3 bundles/square PRODUCT USE The 251 Viste and 252 VistaO AR shingles are laminated architectural shingles fortified with sustainable NEX ASTM ASTM polymer modified asphalt technology for enhanced granule adhesion and increased weather protection.The D7158 D3462 Vista®shingle line features the patented, nailing accuracy design of The Zone®which dramatically improves Glass H correct fastener placement.Vista®Sienna Blend and Silverwood shingles are CRRC-listed and can be used ASTM ASTM to comply with CEC Title 24, Part 6 Cool Roof Requirements.Vista®AR is algae-resistant and warrantied to D3161 D3018 cover. Please consult Malarkey's Technical Services Department for approval of roof systems. Class F Type I COMPOSITION&MATERIALS _. . �. a.._.�_. .. .. .. ..... _ . ..... ...... ..------ .. a._. ...e �e... .., v......... ASTM CSA Vista®shingles are manufactured on a non-woven fiberglass mat and impregnated on both sides with NIX® E1 d8 A123.5 polymer modified bitumen(asphalt)that is compounded with a fire-retardant mineral stabilizer.Its surface Gies A Fir®Rating; incorporates an innovative combination of ceramic granules that provide varied color,weatherability,algae UL RATING protection,even smog reduction;other granules increase energy efficiency by adding solar reflectivity. G. 2218 APPLICATION idtewmw Class 3 Shingles should be applied over a Malarkey underlayment or an approved,code-compliant substitute. t Compliant with CEC Installation instructions are available on the shingle wrapper by scanning the corresponding Quick Response Title 24, Part 6 (QR)code,on our website at WWW.MALARKEYROOFING.COM,or by contacting your local Malarkey Cool Roof Requirementst representative. Industry standards are found in NRCA manuals.Shingles should be attached to decking with FBC'APPROVAL approved fasteners,and Malarkey recommends the use of corrosion-resistant nails for this purpose.Staples #14809 are not allowed. PRECAUTION For best results, Malarkey recommends Vista®shingles be protected from the weather and stored in •Fortified with sustainable NIX® a cool, dry,well-ventilated area until applied.Do not double-stack pallets.Do not use on roofs where the polymer modified asphalt technology slope is less than 2:12(2" [51 mm]per 12" [305 mm]), For slopes 2:12 up to 4:12(4" [102 mm]per 12" Superior granular embedment and [305 mm]), a double layer of underlayment is required(IBC&IRC have an exception for a single layer of ASTM tear resistance D1970 underlayment in lieu of a double layer).Vista®shingles have a factory-applied,self-sealing strip that Larger nailing area of The Zone® activates in warm weather.When applied in cold weather or windy locations, hand-sealing is recommended •Double rain seal protection but not required if sealant activates.On slopes greater than 21"(533 mm)per 12"(305 mm),hand-sealing 3M'Smog-Reducing Granules underneath and six nails are required.Contact Malarkey for further conditions and instructions. Algae-resistant Vistas AR WARRANTY Limited Lifetime Shingle Warranty Limited&Enhanced Wind Warranties Malarkey Roofing Products®offers various warranties to meet specific requirements.The warranty packages available for the Vista®shingle line include a Limited Lifetime Warranty,a 110 mph(177 kph)Limited Wind p,`ESu�utrox Sp�unov Warranty,and can be combined with other Malarkey products for a 130 mph(209 kph)Enhanced Wind Warranty.Vista®AR also features a 12-year Algae Resistant System Warranty from Malarkey.Contact your roofer,local distribution center,or Malarkey for full details.See below for TECHNICAL ASSISTANCE contact ■ e ■ information. ® The Vista®shingle line and other Malarkey products are available throughout North America and Pacific Rim countries. t CRRC and California Energy Code Title Visit WWW.MALARKEYROOFING.COM for additional product information and availability. 24,Part 6 only applies to Vista®Sienna Blend and Silvenvood shingles. Note: Malarkey Roofing Products®Inventory SKU numbers for this product: 251 Vista®and 252 Vista®AR Blend TECHNICAL ASSISTANCE: CORPORATE OFFICE: Effective 9119 Malarkey has technical services assistance available. 3131 N.Columbia Blvd. Telephone:603.283.1191 Supersedes all previously published data Contact Malarkey for details: Portland,08 97217-7472 or 8t O—W.1191 Call weekdays 7:00 am to 5:00 pm PST, P.O.Box 17217 Fax:503289.7644 Check for most current version at 800.545.1191 or 5W,2831191. Portland,OR 97217-02 7 on our website. technlcalinquhies@matarkeyroofing.cam p get 2 STEEP O. RESIDENTIAL nalaff-mvW7 I S TV.!.ST A A'R TECHNICAL PRODUCT DATA F STEEP SLOPE RESIDENTIAL LAMINATE SKU:251 252 NEX® POLYMER MODIFIED LAMINATED I �� ARCHITECTURAL SHINGLES SOLAR REFLECTANCE TECHNICAL DATA Vista®Sienna Blend and Silverwood are listed with the Cool Roof Rating Council. Vista®Sienna Blend and Silverwood have tested to these radiative property values: Cool Roof Rating Council ratings are determined for a fixed set of conditions,and may not be appropriate for determining seasonal energy performance.The actual effect of solar reflectance and thermal C-It emittance on building performance may vary. Manufacturer of product stipulates that these ratings were determined in PRODUCTRATED accordance with the applicable Cool Roof Rating Council procedures. VISTA' VISTA* (SIENNA BLEND) (SILVERWOOD) INITIAL; WEATHERED INITIAL WEATHERED SOLAR REFLECTANCE 0.17 0,16* 0.21 0.21* THERMAL EMITTANCE 0.93 0.94* 0.94 0.94* SOLAR REFLECTIVE INDEX'(SRI) 17 16* 22 22* Related Product ID 0850-0049 0850-0051 Licensed Manufacturer ID:0850 Classification:Production Line 'CRRC Rapid Ratings TECHNICAL ASSISTANCE: CORPORATE OFFICE: Effective sft9 Malarkey has technical services assistance available. 3131 N.Qolumbla Blvd. Telephone:503.283.1191 Supersedes at previously published data; Contact Malarkey for data lS: Portland,UR 97217-7472 or 800,545.1191 Cal weekdays 7:00 aril to 5:00 pm PST P.O.Box 17217 Fax:5©3.289.7644 Check for most current version at 800.545.1191 or 503.283.1191. DR 972i 7-0217 on ourwebsite. technicWinqulries@rriWarkeymofing.com Portland, p zotz SLOPE-SfEEP r Y CenturyLink Belfair Central Office SECTION 07 31 13 ASPHALT SHINGLES PART 1 GENERAL 1.1 SECTION INCLUDES A. High profile laminate asphalt shingles. 1. Vista AR(252). B. Self-adhered vapor barrier Rt�C�/V C. Underlayment and accessories. D. Vented nail base insulated panels. 615 AR ' ?O20 E. Rough carpentry AldOr trE,�J F. Roof related sheet metal 1.2 REFERENCES A. ASTM International (ASTM): 1. ASTM C209-Standard Test Methods for Cellulosic Fiber Insulating Board. 2. ASTM C1289-Standard Specification for Faced Rigid Cellular Polyisocyanu rate Thermal Insulation Board. 3. ASTM D226-Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing. 4. ASTM D1621 -Standard Test Method for Compressive Properties of Rigid Cellular Plastics. 5. ASTM D1970-Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials 6. ASTM D3018-Standard Specification for Class A Asphalt Shingles Surfaced with Mineral Granules. 7. ASTM D3161 -Standard Test Method for Wind-Resistance of Asphalt Shingles(Fan- Induced Method). 8. ASTM D3462 -Standard Specification for Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules. 9. ASTM D4586-Standard Specification for Asphalt Roof Cement,Asbestos- Free. 10. ASTM D4601 -Standard Specification for Asphalt-Coated Glass Fiber Base Sheet Used in Roofing. 11. ASTM D4869-Standard Specification for Asphalt-Saturated Organic Felt Underlayment Used in Steep Slope Roofing. 12. ASTM D6757-Standard Specification for Underlayment Felt Containing Inorganic Fibers Used in Steep-Slope Roofing. 13. ASTM D7158-Standard Test Method for Wind Resistance of Asphalt Shingles(Uplift Force/Uplift Resistance Method). 14. ASTM E84-Standard Test Method for Surface Burning Characteristics of Building Materials. 15. ASTM E96-Standard Test Methods for Water Vapor Transmission of Materials. 16. ASTM E108-Standard Test Methods for Fire Tests of Roof Coverings. 0731 13-1 { t B. Underwriters Laboratory (UL): 1. UL 790-Standard Test Methods for Fire Tests of Roof Coverings. 2. UL 2218-Impact Resistance of Prepared Roof Covering Materials. 1.3 SUBMITTALS A. Material Safety Data Sheets for each product to be used B. Product Data: Manufacturer's data sheets on each product to be used, including: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Installation methods. C. Shingle color chart for selection by Principal of shingle color(standard colors) D. Sheet metal color chart for selection by Principal of sheet metal color(standard colors) 1.4 QUALITY ASSURANCE A. Primary Roofing Materials Manufacturer Requirements: 1. Manufacturer specified asphalt shingles for a minimum of ten years. B. Installer Qualifications:Approved by the manufacturer to install the specified products and provide the specified warranties. C. Source Limitations: Obtain hip and ridge shingles, starter, all underlayment products, insulation, and vented nail base from single source,from single manufacturer. D. Fire-Resistance Characteristics: Where indicated, provide asphalt shingles and related roofing materials identical to those of assemblies tested for fire resistance per test method below by UL or another testing and inspecting agency acceptable to authorities having jurisdiction. Identify products with appropriate markings of applicable testing agency. E. Exterior Fire-Test Exposure: Class A;ASTM E108 or UL 790,for application and roof slopes indicated. 1.5 DELIVERY, STORAGE, AND HANDLING A. Store products in manufacturers unopened packaging until ready for installation. B. Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction. 1.6 PROJECT CONDITIONS A. Maintain environmental conditions(temperature, humidity, and ventilation)within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits. 1.7 PROJECT MEETINGS A. Pre-Construction conference call: 1. Prior to the start of the roofing project, the Principal shall hold a conference call with the roof consultant, the roof consultants Quality Assurance observer, the roofing contractor's project manager, superintendent and foreman as well as any subcontractors 2. The agenda for the meeting shall include: a. A discus the previously reviewed submittals, if needed. 0731 13-2 � r b. Establishment of a schedule for the work. C. Selection of staging and storage locations. B. Final Inspection: Following the completion of the work, a final inspection shall be scheduled by Owner's Representative.Any uncompleted work shall be noted on a punch list. 1.8 MANUFACTURER'S WARRANTIES A. Standard Warranty: Shingles subjected to terms and conditions of the standard Manufacturer's Limited Warranty. Wind warranty coverage is subject to the shingles being sealed. 1. Warranty Length: 40 years. 2. Limited Term Resistance to Wind: 130 mph (209 kph). 3. Algae Resistant System Warranty from Manufacturer shall include algae resistance to discoloration from algae growth for a period of 12 years(Vista AR)from the date of substantial completion. B. Special Warranty for Polymer Modified Shingles: Manufacturer's standard or customized form, without monetary limitation (NDL), in which manufacturer agrees to repair or replace components of asphalt shingle roofing system that fail in materials or workmanship within specified warranty period. Includes asphalt shingles, flashings, roof insulation, nail base, and other components of roofing system. 1. Warranty Length: 15 years from date of Substantial Completion. C. Upon project completion and acceptance by Owner,the Roofing Contractor shall promptly provide executed copies of the specified warranties. 1.09 INSTALLERS WARRANTY A. Upon project completion, Contractor shall furnish an installer's warranty covering workmanship and material 1. Warranty duration 5-years 1.10 MATERIAL SUBSTITUTIONS A. Requests for material substitutions or substitutions for different roof systems must be submitted to Consultant at least five (5) days prior to the bid deadline for consideration. Requests for material substitutions or substitutions for different roof systems received less than five (5) days prior to the bid deadline shall not be considered. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturer: Malarkey Roofing Products, which is located at: 3131 N. Columbia Blvd. P. O. Box 17217; Portland, OR 97217; Toll Free Tel: 800-545-1191; Tel: 503-283- 1191; Fax: 503-289-7644. B. Requests for substitutions must be submitted to Consultant for review at least five business days prior to the bid due date. 0731 13-3 2.2 SHINGLES A. High Profile Laminate Shingles: 1. Vista AR(252)as manufactured by Malarkey Roofing Products. a. Malarkey Vista AR shingles hold a Class A Fire Rating. b. As manufactured, Vista AR meets the requirements of: 1) ASTM D7158 Class H,ASTM D3462, ASTM D3161 Class F,ASTM D3018 Type I,ASTM E108 Class A, UL 2218 Class 3 Impact Resistance, and CSA A123.5. 2) FBC Approval: No. 14809. 3) Listed with Intertek/WHI. C. Performance: 1) Limited Material Warranty: 40 years. 2) Limited Wind Warranty: 12 years. 110 mph (177 kph). 3) Enhanced Wind Warranty: 130 mph (209 kph). 4) Algae Resistant System Warranty: 12 years. 5) NEX polymer mix includes recycled rubber and plastics. 6) SEBS polymer modified asphalt laminate adhesive. 7) SEBS asphalt seal-down adhesive. 8) 3M Smog-Reducing Granules. 9) Granule adhesion—0.35g B. Color: Color shall be selected from the manufacturer's standard colors. 2.3 VAPOR BARRIER—2 plies below R-27 Polyiso insulation A. NEX Polymer Modified, Self-Adhering Fiberglass Underlayment: 1. Product: Malarkey 401 Arctic Seal. 2. As manufactured, meets requirements of ASTM D1970. 3. Self-adhering sheet shall be nominal 55 mils(1.4 mm) thick. 4. NEX polymer mix includes recycled rubber and plastics. 2.4 UNDERLAYMENT A. Synthetic Underlayment: 1. Product: Malarkey 1031 SecureStart Plus. 2. As manufactured, SecureStart Plus meets the requirements of ASTM D226, ASTM D4869, CSA A123.3, and ICC-ES AC188. 3. FBC Approval: FL23186. 4. Code Approval: CCRR-1082. 5. Sheet shall be nominal 16 plus or minus 1 mil(0.41 mm)thick. 6. Sheet shall be 48 inches(1.2 meter)in width. 7. One(1) roll covers ten (10) squares of roof. 2.5 VENTED NAIL BASE INSULATED PANELS A. Approved Manufacturers: 1. Product: Hunter Panel 2. Product: Rmax Insulation B. Insulation Value: 1. Flat Stock Insulation R-Value: R-27 in two layers with joints offset minimum of 6 inches C. Physical properties(Foam Core): 1. Compressive Strength per ASTM D1621 and ASTM C1289: Type II, 20 psi(138 kPa) minimum Grade 2. 0731 13-4 2. Dimensional Stability per ASTM D2126: 2 percent linear change within 7 days. 3. Moisture Vapor Transmission per ASTM E96: Less than 1 U.S. perm (57.21 metric perm). 4. Water Absorption per ASTM C209: Less than 1 percent by volume. 5. Flame Spread (Foam Core) per ASTM E84: Less than 450. 6. Service Temperature: Minus 100 to 250 degrees F (Minus 73 to 122 degrees C). D. Panel Construction and Fasteners: 1. Top layer of Plywood. a. Thickness: 5/8" 2. Middle layer of vented air space with 2x untreated DF wood spacers and a bottom layer of black fiber reinforced faced polyisocyanurate foam insulation. a. Vented Air Space and Spacer Thickness: 1.5 inches 3. Fasteners: 3/16 inch shank, corrosion resistant type with oversized heads. a. Fastener Length:As recommended by the panel manufacturer. b. Fasteners shall be equal to the panel depth plus a minimum of 1 inch penetration into the structural substrate supports. 2.6 RELATED PRODUCTS A. Eave and Ridge Vents, below deck ventilation system. B. NEX Polymer Modified 12 inches Hip and Ridge: Malarkey No. 227 RidgeFlex Scotchgard. C. Full-Width Perforated Starter Shingle: Malarkey Smart Start No. 210. D. Plastic Roof Cement conforming to ASTM D4586. E. Fasteners: Hot Dip Galvanized nails with minimum 3/8 inch head. PART 3 EXECUTION 3.1 DELIVERY, STORAGE, AND HANDLING IMPORT A. New and dry roof materials delivered to the job site in containers unopened and undamaged. Manufacturer's products stamped with labels, names, and run codes of manufacture and testing laboratory. B. Store underlayment materials on ends only. Discard rolls which may have been flattened, creased, or otherwise damaged. Place materials on pallets or wood sleepers. Do not stack palletized materials. C. Cover underlayment rolls with weatherproof materials secured to prevent materials from becoming exposed to moisture. Use breathable tarps. D. Disperse materials stored on the roof surface to avoid concentrated loading. Set larger concentrations over structural members. 3.2 ENVIRONMENTAL REQUIREMENTS A. Application of roofing materials shall not be performed when weather conditions interfere with good roofing practices. 3.3 DEMOLITION A. Remove and legally dispose of exiting shingles, shingle underlayment and roof related sheet metal. 0731 13-5 B. Sheet metal canopy roof in back of building to remain(Not in Contract) 3.4 VAPOR BARRIER A. Apply two layers of self-adhering membrane to the entire exposed surface if the existing wood roof deck. Top Layer of self-adhering membrane shall be offset from lower layer of self-adhering membrane by a minimum of 8" B. Extend self-adhering membrane a minimum of 6" up onto all roof-to-wall conditions 3.5 WOOD BLOCKING, VENTED INSULATION AND NEW SHEATHING A. Loose lay two layers of rigid insulation board equaling R-27 or greater B. Fasten 2X4 untreated DF battens(on their sides) on top of insulation. Fasten battens to existing roof structure. Battens shall be spaced 24"on center. Battens shall be installed eave to ridge at each end of the roof and at 24"on center in the field of the roof C. Fasten 5/8"plywood sheathing over battens. At the ridge of the roof, there shall be a nominal one inch gap between the sheathing for airflow D. Fastening pattern for battens and plywood sheathing shall meet material manufacturer's requirement 3.6 GUTTERS A. At all locations where gutters currently exist, install Malarkey Enduro Vent as per the manufacturer's requirements B. Fabricate and install new gutters and downspouts matching the size and configuration of the current gutters and downspouts 3.7 UNDERLAYMENT AND EDGING A. Apply specified underlayment as follows: 1. Slopes of 5 units in 12 units or greater, apply single layer, polymer modified fiberglass or synthetic underlayment laid parallel to eaves, lapping to the 2 inch ply line, and 6 inches on ends, end laps staggered 6 feet from course to course. 2. Slopes of less than 5 units in 12 units, apply double layer of specified underlayment laid parallel to eaves, installed shingle fashion with 50 percent side laps and 6 inch end laps. B. Pipe Flashing: Apply ASTM D1970 underlayment around the pipe, sealing it to the field underlayment prior to installing the metal pipe flashing. Install and secure the metal jack so the bottom flange laps over onto the shingles. Side and top flanges shall have shingles lapping onto the flange. Shingles that lap onto flanges shall be sealed to the metal with asphalt roof cement conforming to ASTM D4586. C. Perimeter Flashing: Use non-corrosive, 24-gauge sheet metal drip edge flashing. Install prior to underlayment on eave edges of roof and then along rake edges over the ends of installed underlayment. Install drip edge with flanges large enough (recommend 4-inch flanges)to completely cover roof edges. Secure with galvanized(or compatible) roofing nails, centered on the top flange at 8 to 10 inches O.C. or according to local code requirements. 3.8 APPLICATION OF SHINGLES A. Laminate Shingle Application; 8 inches offset- Diagonal Pattern: 1. Starter courses: Use Malarkey starter shingles or 3-tab shingles with the tabs cut off; 0731 13-6 apply to eave and rake edges of roof. 2. Cut 6 inches off the length of the starter strip and apply at a lower corner of roof. The starter course shall overhang the edge metal 1/4 to 3/4 inch. Fasten with four(4) nails, 1-1/2 inches to 3 inches up from the eave with one fastener 1 inch from each end and the remaining two evenly spaced on the same line as the end fasteners. 3. Continue starter course across the roof with a full-length shingles, butting them loosely together to avoid buckling. 4. First course: Start with a full shingle applied directly over the starter course at the same lower corner of the roof, and secure with fasteners. 5. Second course: Cut 8 inches off one end of a full shingle and apply the remaining piece over the underlying, first course shingle.Align the bottom edge along a line level with the"sawtooth"overlay in the preceding course, exposing the first course 5-5/8 inches. Secure with fasteners. 6. Succeeding Courses: Courses three through five are begun with partial shingles, each progressively 8 inches shorter, establishing the overall diagonal pattern or stair-step effect. (Pieces cut from shingles along one rake edge can be used to finish off courses on the opposite rake.) 7. Apply a full shingle adjacent to each of the first five courses to extend the pattern. Butt the shingles loosely together to prevent buckling. 8. Courses six through ten repeat the process beginning with a full shingle and repeating the 1-to-5 course cycle on up the roof. 9. Strike a chalk line every six courses or so to ensure straight courses. Shingles may be laid from either lower corner of the roof. Start at the rake edge and follow layout and cutting instructions as required for proper application. Installation of shingles with a 4 inch offset is also acceptable. Offsets must be no less than 4 inches 3.9 FASTENERS A. Laminate Nailing Pattern: Nails must be placed within the nailing zone, 1 inch in from each end of the shingle and the remaining nails evenly spaced on the same line as the end nails. Fasteners shall be seated flush to the shingle surface and not overdriven to cut into shingles. When fastening, butt shingles loosely together to prevent buckling. 1. Fasteners per shingle/high wind areas: Six(6), including starter shingles. END OF SECTION 0731 13-7 '. 12292(ISM SrSE,SWM ZOS GENERAL NOTE e9NMl Wn 9Bp12 � � 1. FlEID VERQ-Y ALL FMSTING ORNENS[ONS MUO0.TO Rwre:4254R20103 f '' OEMOiinON MID CONSI0.UCRW. Far9259620114 1. PROTECT ALL RFfIN Tw-, MLLUDIN o—o _ 000R3,GYAZnIG,LWVER3,STRUCIURM,EIECIRICN., - PWMBING,AIID HVRC. ` O m ®© II ©® ROOF DEMOLITION RAG NOTE m = D1 F]OSTWG ROOF A4SEMBLY:A4NRLTSMIMYE ROOF wD SYSTEM:M1SMiRLT SHINQ.ES,UNDFRIAYMENr,WOW � n5 ROOF DEQ.aRTT DVSUUT(OH INSTPL818ELOw THE C iNs ROOF OEIXBETWEEN THE RAFI[RS J w 00 D2 REMOVE ROOF SYSTEM GOWN TO EOSTING ROOF N D—,1nIU1 RT ML SP91AR tlINDMn Y O 00 D3 REMOVE EXItiONG C.UT1ERS pND DOWN3VO1R5. Q> D4 P@E PENETRRnaw U N > �q D5 EIOSInIG MERLW[ULEQUIDMENTI VExr II __ ! II DeSkin:JDY Drawn:JMY I Che&k d:JDY II iJob No.20449 II Issue: Dale:1/18/2020 II Drawing Title: i Demolition II Drawing Drawing Number: i D-1.0 STEEL OEQ(AT eiC!(Bl.1LGNG EMMN E- 1 NOT tlJ0.LOEOINPROJECt SCALE 1/8^a1.0^ RECEIVED MAP 12 2p7r, 615 VV. 1rW�L GENERAL NOTES BaNNV/.wasw,z 2 nveRrtrau oannc msxsoNS PR aaro m�e:as 4ez DENatrtox awD cors,Rucrlox. Pa�azsaazat,4 3. P0.p1'ECTML IIFA6 TO REPM[N IIiClLD1NG WALLS,DOORS, (iaZMt+,111DVER5,SIROCNNUI.,ELEDiRiGL,PLURWIIMi, _ MD HVAC. 1. 4NLL PpIEfRaTRN!(PPUCoWUM Or SHOWN. W ®� a. aPPROVEO LMtENVLMaNUFACINRER5:M4MRFY O ca F- II --14P d ARCNRECRIRAL ROOF FLAG NOTES m r ��' II a' Ai NEW ROOF M1SSFMBLrASPHMT SHM(iE RDOF SYSTEM: Y « II RSPHMT SNIN4F9,SYNTHETIC UNDERUYMFM,NEW 5/8 PLYWOOD RIEAT W R.27RtG9)PLSNIgTRN!(Wflll lX J of CO BLaosIGA 2-0LY SEIFMJHFBFD VaPgt&VIRffN,OOSNIG �'. Z N ! WOOD OEIX. m 0.EffAEN¢OETM UA-2.0 � � Ql C M Q • REE£RENCE OFran Z.0 N ® I � RLDr;E wrtH coNlvluous Rnx,E WNr REEEAEIKE DETAIL 3/a-3.0 I � A4 RdEPENflRA RFfiRQ10=RTWaLL m � It[TALL NEW GVRER MID ODWNSPD115. _ IIREPFAEtKF DETaD55/a2.0 MID fi/A-2A. --- i. II ® E)WT➢IG VENT PND OTlffR M[CYIAtIIGLPENETRATRYI. De50:JDY Drawn:]MY II CtTeticetl:JDY I Job No.20.949 Issue: II Dare:i/La/zozo i 1 (I Drawing Title: Architectural Drawing Drawing Number: i ® i A-1.0 ELL AATN9CYLBULDN3f3IlRAf10E- NOiINCLU MFROJECf scnLe RECEIVE MAR 12 2020 615 W. Alder Street i ArMmAl® 11292LN°i5T$SWMZOS BOMeM1 WA9BOII N1me:42SCB ti9 114 Fu a25.9BI.O W p ro n Ea / erwre y� 3 Y y8 C (A J W N Z NI Ala o m « ,o yw ILI ail rAaraeu (-� N iI NEW ROOF SVSTEMCRO58 SECTION RAKE WffN:TARTER COURSE unoalu .. [ A-2.0 A 2 O RNX3E VATfi CONTINUOUS RIDGE VENT A-2 0 VENT PIPE PENETRATION - - ecuE A-2.0 Design:JOY Drawn:JMY i Ched ed:MY n Job No.20449 j ;'. xaArwm Issue: ,�..' Rl NR NtNnIpi ROI /OxPOiWK ur.60na Date:1/18/2020 z- MAIN nnrr 'w P.eM R'm Jj a P�A� Drawing Title: Mvm •a. Details 1 Irnr1NRa amttff�ON6x!�b!n1p� tnM/V Nl nN'/NIM(S iBMIt 5 VENTED FASCIA DETAIL SMAGE) li VENTED FASCIA DETAIL ---_.. -_... ___.-- A 2•o Drawing Number. A-2.0 RECS/V&D MAR 12 201t T5 VN• alder Street ■ rjovk Iznzm"srs�swmms mneu,wa seorz Mme:01SCB2.0103 Fax0Z598z.011< O m l7 STEEL DECK- I �IN PROJECT m IN PROJECTCT � Y W oa oa Z In 7 0 Go N N f0 Q (� N i Design:MY Drawn:MY i Checked:MY Job No.20449 Issue: i ® Date:1/18/2020 Drawing Title: Isometric Drawing Drawing Number: ' A-3.0 i RECEIVE MAR 12 2o2o 615 W. Alder Street H V N+E R HUNTER PANELS FASTENING INFORMATION FOR WOOD DECKS The Hunter Panels SIP WD Fastener is intended to mechanically attach Cool-Vent and H-Shield NB to wood substrates. The Hunter Panels SIP WD Fastener has the following features: • FM approved — plates not required STAR/SPIDER • Star/spider head eliminates need for washer and offers dramatically increased DRIVE HEAD pull-out value (FREE DRIVER • 100% American made IN EACH BOX) • Fast, One-Step installation • No pre-drilling • Multiple bits included in each pail 3116"SHANK COOL-VENT DIAMETER zOSB Description Board Test Wood MADE OF HEAT --► Spacer Pull-through (Ibs) 630 [so Pull-out Ibs : TREATED ( ) STEEL FOR Board DRAMATICALLY 1/2" plywood 442 INCREASED 5/8" plywood 459 STRENGTH AND Substrate DRIVABILITY 3/4" plywood 710 Douglas Fir(1" pen.) 768 Wood ULTRA COATED ► Fasteners should never be struck FOR UNMATCHED with a hammer during installation. CORROSION RESISTANCE H-SHIELD NB Physical Data Chart OSB Board Head Diameter .625" a�rd Thread Diameter .240" Shank Diam eter .190 Minimum u Substrate penetration 3.5", 411,4.5", 5", 5.5", 6", into Fastener Length 6.5", 7", 7.5", 8% 91, 1011, wood deck. Wood 11", 1211, 13", 14" RECEIVED For more information on these products, MAR 12 2020 visit www.hunterpanels.com. F3 15 Alder Street, H U N + E R Hunter Panels I 15 Franklin St, Portland, Maine 04101 1 888.746.1114 I www.hunterpanels.com V NEW YORK ILLINOIS FLORIDA TEXAS UTAH PENNSYLVANIA WASHINGTON Energy SmartPolyiso aan H-SHIELD NB FASTENING PATTERN FOR STEEP SLOPE APPLICATIONS GREATER THAN 1/2:12 H-Shield NB with OSB H U N t E R 47 1/2"x 95 1/2" A i —47 1/2" 1A - I O O O O 888.746.1114 HunterPanelsxom i f 3/4" 0 Hunter Panels Products •H-Shield NB with OSB - 47 1/2" x 95 1/2" 9s 1/2" 3 I 2" • H-Shield NB with Plywood - 48" x 96" Roof Types: I O O O O • Shingles • Slate 303/4" • Tile • Standing Seam Metal O O O O , Deck Types h°I-- 1s"---I-151/2'---I--15"--I1° • Wood Framing- 16" or 32" OC • Concrete H-Shield NB with Plywood • Steel 48"x 96" Notes • H-Shield-NB must be installed on a structural O O O O deck. Do not install directly to framing. H-Shield- I NB is not a structural panel. 31 • Use Hunter Panels SIP fasteners. • Fastener must penetrate the structural deck by i O O O O at least 1". I • For slate and tile roofs, contact manufacturer for recommendations. 96" 32" • For UL-90 rated assemblies under select metal roof systems, please contact the Standing Seam Metal manufacturer for approved fastener, plate O O O O and fastening pattern. 1 f 31" RECEI o 0 0 0 � x 1" I1"I--151/4"-1—ts 1/2"—�--1s 1/4"--It") - ��� �� �IP�� NEW YORK " ILLINOIS " FLORIDA - TEXAS - UTAH - PENNSYLVANIA . WASHINGTON 0919 i i cO� �~ MASON COUNTY COM 'Zda `000 I 2 COMMUNITY SERVICES DEPARTMENT Mason County Bldg. 8, 615 W.Alder Street Shelton,WA 98584 www.co.mason.wa.us (360)427-9670 ext.352 Belfair(360)275-4467 Elma(360)482-5269 t8.S4 Roofing Sq ft area CC90 Type of Roofing to be Applied .S *6Le5 C(J!!56 4, Number of existing layers Roof Pitch: Tear off: Yes No Use of buildin Construction Type: NW& Roofing Classification Occupancy classification) (wood,steel frame,masonry etc.) **See note below (A,B or Q Include manufacture specifications verifying materials meet roofing classification. B&C roofing classifications require site plan drawn to scale. /i Will insulation be installed? `Yes _No Existing Insulation,describe : ?AfT/NSttLgTlDfJ FeW6 0 Z X(S 5?<<,K, �'(lAA1� fL��E• Existing roofs shall be insulated to the requirements of R-38 if electric heat, R-30 all others, IF: a.The roof is uninsulated or insulation is removed to the level of the sheathing or b.All insulation in the roof/ceiling was previously installed exterior to the sheathing or nonexistent. Roof ventilation,describe : WO) 0AVC0, AGV Oa8 dZ/AGe� 1l A�J/old itiwfdeck&innlallog Ispeetiun.required.below«new ir+uo�>ug ilnatria>f can"be applied Name of Business: Subject Property Address: Z3(A5- O t%�Eir At6" S Assessors parcel number(s) t Z3 Z _ 6o uO (Address and parcel number required for all applications) A b 4 Owner: �e7wr �A i.I J VV Ali - �� Mailing address: ` 0 Ci L�j+dl State: Zia:rl e4/D-7 Phone (?,0,� FAX ( ) E-Mail, '_ft(WV5i,L"fTNA A/fwW404(0/h **Expedited perrmits may,bye aUti>I :fort".A ng I hereby authorize Mason County representative(s)to inspect my property Monday-Friday between the hours of 8 a.m. and 5 p.m.during this ermi application pro ss for purposes of verifying site conditions. Owner: Date: �� �" t MASON COUNTY COMMUNITY SERVICES PERMIT ASSISTANCE CENTER: Permit No: •BUILDING •PLANNING•FIRE MARSHAL 615 W.Alder St-Shelton,WA 98584 Phone Shelton:(360)427-9670 ext 352 • Fax:(360)427-7798 Phone /..r/'C( `�^ tsyt Belfair.(360)275-4467• Phone Elma:(360)482-5269 t \ E'v BUILDING PERMIT APPLICATION VVV PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: IVIAIR 2 2020 NAME: e u K. NAME:Y ©0 1 6 5 �/�f MAILING ADDRES : 3 t N Vtf� MAILINN ADDRESS: A5 er Street CITY:I A600 k STATE: ZIP:c Cr 7 CITY: a,"& STATE: ZIP:_ PHONE#1: }(, `3` - sS� PHONEZ 3 �7l� CELL: �✓ 3� PHONE#2: EMAIL: C « EMAIL:�T rn49S Cs9A-9 L&I REG M EXP. CONTACT PERSON: OWNER❑ CONTRACTOR A OTHER❑ NAME: ZCf-' A*UA*44I5� MAILINGADDRESS194) S. CNSMM/WAJ AV4f CITY: r"Aa ST TE: ZIP: PHONES CELL:ZS _Tr S3a EMAIL: 0 3 PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number) ZONING LEGAL DESCRIPTION(Abbreviated) FIRE DISTRICT SITE ADDRESS CITY DIRECTIONS TO SITE ADDRESS IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES❑ NO m/ IS PROPERTY WITHIN 200 FT: (Checkall that apply): �` SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ TYPE OF WORK: NEW ❑ ADDITION ❑ ALTERATIONY REPAIR❑ OTHER USE OF STRUCTURE(Residence,Garage,Commercial Bldg,Etc.) 1400JE S S44/TG-W" `p eu(t/ IS USE: PRIMARY❑ SEASONAL❑ NUMBER OF BEDROOMS NUMBER OF BATHROOMS HEATED STRUCTURE? YES(Whole Bldg) YES(Part[s]of Bldg)❑ NO❑ DESCRIBE WORK f vfA/6 ExI57/A16 Rooh.-J10 is) L Mj6 iNrsuc,A�risao�l (lral.ation/ProjectBldAmo-t: SQUARE FOOTAGE: 1ST FLOOR sq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft. DECK sq.ft. COVERED DECK sq.ft. STORAGE sq.ft. OTHER sq.ft. GARAGE sq.ft. Attached❑ Detached❑ CARPORT sq.ft. Attached❑ Detached❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE MODEL YEAR LENGTH WIDTH EDROOMS BATHS S NUMBER OWNER acknowledges that mission of inaccurate informatio ay result in a stop work order or permit revocation. Acknowledgement of such is by s ature below.I declare 1 am the owner and I further declare that I am entitled to receive this permit and to do the wo roposed.I e obtained permission from all the necessary parties,including any easement holder or parties of interest r ' this project. The owner or legal representative,represents that the information provided is accurate and grant p s of Mason County access to the above described property and structure(s)for review and inspection. is permit/app' ion becomes null&void if work or authorized construction is not commenced within 180 days construction work is s=BY period of 180 days. PROOF OF CONTINU N OF WORK ON THIS PERMNS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLI ION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON COUNTY CODE 14.08.42) X Signature of OWNER(Must be signed by the OWNER) Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL PERMIT SPECIALISTS make: lanner: pproved&Readv for Pick-Up: Visit us on-line: http://www.co.mason.wa.us/community_dev/ Rev.127,12016byJBN A► � Centuryl-ink Belfair Roof System Shingle roof 47 sqs Remove existing roofing and flashings to deck Install 2 layers of Malarkey 401 Artic Seal Install wood blocking at perimeter to match new insulation thickness. Eave blocking has to stay inline of eave facia to allow eave vent installation Loose lay insulation Install 2" x 4" DF laid flat 16" OC from eave to ridge, fasten every 12" OC Install 5/8" plywood attach per included fastening pattern and cut for ridge vent (no plates are required) Hunter Panels SIP WD Fasteners are required Install 2 layers of Malarkey 1031 Secure Start Plus Install Endura Facia Vent Install new rake facia as needed Install drip flashing over top eave vent piece Install new rake flashing down to paint line Install Malarkey Vista AR starter and shingles Install Malarkey Endura ridge vent Install Malarkey ridge shingles New gutter and downspouts R C ic��1/ AMR SAS 'V' A/Cler c ,_