HomeMy WebLinkAboutBLD2019-00233 Final 2-Story SFR - BLD Permit / Conditions - 8/14/2020r
Mason County
Mason County - Division of Community Development
�\ 615 W.Alder St. Bldg. 8
Shelton, WA 98584
-_ 360-427-9670 ext 352
www.co.mason.wa.us
B DD2019-00233 NEW SINGLE FAMILY RESIDENCE
PROJECT DESCRIPTION: NEW 1606 SQ FT 2-STORY SFR ISSUED: 05/13/2019
SITE ADDRESS: 260 NE LAKERIDGE DR BELFAIR
EXPIRES: 11/09/2019
PARCEL: 223047690130
APPLICANT: RAYMOND BISSER OWNER: RAYMOND BISSER
PO BOX 168 PO BOX 168
ALLYN,WA 98524 ALLYN,WA 98524
VALUATIONS: FEES: Paid Due
R-3 VB Residential, one- 1080.00 $130,410.00 Building Permit Fee $1,746.08 $0.00
and two-family Change in Tenant- Minor EH $110.00 $0.00
Covered Deck/Carport 576.00 $12,672.00 Plan Review
R-3 VB Residential, one- 526.00 $63,514.50 Plumbing Base Fee $25.00 $0.00
and two-family Planning Review Fee $240.00 $0.00
Mechanical Fees $73.00 $0.00
Mechanical Base Fee $30.00 $0.00
Plan Check Fee $1,134.95 $0.00
State Fee-Residential $6.50 $0.00
Plumbing Fees $122.00 $0.00
Total: $206,596.50 Totals : $3,487.53 $0.00
FIXTURES
(fit Mechanical Fixtures Qt Plumbing Fixtures
1 Dryer Vent(s) 1 Number of Clothes Washers
1 Kitchen Exhaust Hood(s) 1 Number of Dishwashers
1 Ductless Heat Pump 1 Number of Kitchen Sinks
3 Spot Vent Fan(s) 1 Number of Showers
1 Number of Water Heaters and or Vent
2 Number of Hose Bibs
Printed by:Ariane Paysse on:05/13/2019 01:21 PM
Page 1 of 6
4
Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg. 8
Shelton, WA 98584
- _ 360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCE BLD2019-00233
Qt C Plumbing Fixtures
2 Number of Bath Tubs
2 Number of Toilets
3 Bathroom Sink
REQUIRED INSPECTIONS
Setback Inspection Rough- Plumbing Inspection
Footing Inspection Mechanical Inspection
Foundation Wall-Pre-Pour Inspection Insulation Inspection
Shearwall Inspection BLD-Final Inspection
Framing Inspection
CONDITIONS
* Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer
specifications and in accordance with IRC Section R315.
Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level
of the dwelling.
EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations(including addition or alteration of
fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or
created.
* The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility
of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked
"APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is
responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of approved documents will result in failure of required building inspections.
* All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as
adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted
classification. Any non-approved change of use or occupancy would result in permit revocation.
* Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a
permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor
& Industries(L&I).
For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415-
4000.
* Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries,
Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an
unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either
the homeowner, agent for the owner or a registered contractor according to WA state law.
Printed by:Ariane Paysse on:05/13/2019 01:21 PM
Page 2 of 6
s
Mason County
r�
\� Mason County - Division of Community Development
✓= � � 615 W. Alder St. Bldg. 8
\\ Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCE BLD2O19-00233
All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor
increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way.
* The foundation/footing must be placed on undisturbed, firm-native soil.
* Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC
R403, applicable sections of the IRC, and IMC.
Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the
purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including
infiltration and ventilation. Design calculations shall be available for inspection during inspection.
Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct
systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other
approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be
marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used
with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-
sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings
shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B
and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm)
and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint.
Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation
instructions.
Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be
insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit
documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building
Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website
titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results(Existing Construction)." Duct tightness testing is not
required if the air handler and all ducts are located within the heated space.
* By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your
"Approved Site Plan"to ensure these structures meet the setback conditions listed.
* Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the
structure.
* A Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more
information contact Public Works, at(360)427-9670, ext. 450 or 100 W Public Works Dr. Shelton. The building permit will
not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and
approved.
* REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable
provisions of the current code and the manufacturer's installation instructions.
A drip edge shall be provided at eaves and gables of shingle roofs.
* The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the
approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule,
minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being
performed or approvals granted.
Printed by:Ariane Paysse on:05/13/2019 01:21 PM
Page 3 of 6
Mason County
Mason County - Division of Community Development
615 W. Alder St. Bldg. 8
Ht;, Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCE BLD2019-00233
* Adopted IECC/Washington State Energy Code Compliance has been approved as follows:
Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window(Max U-
Factor):0.30, Skylight (Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation
R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10.
1a EFFICIENT BUILDING ENVELOPE 1a:
Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U = 0.28
Floor R-38
Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab
or
Compliance based on Section R402.1.4: Reduce the Total UA by 5%. 0.5
3db HIGH EFFICIENCY HVAC EQUIPMENT 3d:
Ductless Split System Heat Pumps, Zonal Control: In homes where the primary space heating system is zonal electric
heating, a ductless heat pump system shall be installed
and provide heating to the largest zone of the housing unit.
1.0
5a EFFICIENT WATER HEATING 5a:
All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 GPM or less.All other lavatory faucets
shall be rated at 1.0 GPM or less.c
0.5
5c EFFICIENT WATER HEATING 5c:
Water heating system shall include one of the following: Gas, propane or oil water heater with a minimum EF of 0.91
or
Solar water heating supplementing a minimum standard water heater. Solar water
heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the Solar Rating and Certification
Corporation (SRCC)Annual Performance of OG-300
Certified Solar Water Heating Systems
or
Electric heat pump water heater with a minimum EF of 2.0 and meeting the standards of NEEA's Northern Climate
Specifications for Heat Pump Water Heaters
1.5
" Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance
with Mason County Title 14.28 and 14.17.
* A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit
application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the
responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that
Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement
of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater
Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel
Stormwater Site Plan"constitutes an approved plan based on the criteria listed on the application/worksheet. If the
development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other,
parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final
inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater
management system have been installed as approved on the stormwater site plan.
* All property lines shall be clearly identified at the time of foundation inspection.
Printed by:Ariane Paysse on:05/13/2019 01:21 PM
Page 4 of 6
Mason County
1 Mason County - Division of Community Development
\\\ 615 W. Alder St. Bldg. 8
Shelton, WA 98584
_.. 360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCE BLD2019-00233
Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly
corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of
pressure treated material.
* A permanent certificate, completed by the builder or registered design professional, shall be posted on a wall in the space
where the furnace is located, a utility room, or an approved location inside the building. When located on the elctrical panel,
the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect labek, or toher reqyired
Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls,foundation (slab,
basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the
solar heat gain coefficient (SHGC) of fenestration. Where there is more than one value for each component, the certificate
shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service
water heating equipment, duct leakage rates including test conditions as specified in WSEC Section R401.3 & R402.4.1.2,
and air leakage results if a blower door test was conducted.
Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air
changes per hour when tested with a blower door in accordanve with IECC/.WSEC Section R402.4.1.2.
The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution
panel. Air leakage testing is not required for additions less than 500 square feet. Reference IECC/WSEC R402.4.1.2.
Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2015 Certificate" and are
available in or sheets. The Mason County Permit Center will also have some available.
* WIND LOADS- Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic
wind speed for Mason County is 85 MPH.
* Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site
plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed.
* All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and
plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee
schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections
being performed or approvals granted.
* All building permits shall have a final inspection performed and approved by Mason County Building Department prior to
permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property
records on file with Mason County as being non-compliant with Mason County ordinances and building regulations.
* All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building
Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration.
Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No
more than one extension may be granted.
* All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or
any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction.
* A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance
with IECC/WSEC Section R404.1.
* The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more
than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards
for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to
another fire apparatus access road which connects to a county maintained public road.
Printed by:Ariane Paysse on:05/13/2019 01:21 PM
Page 5 of 6
Mason County
a Mason County - Division of Community Development
615 W. Alder St. Bldg. 8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCE BLD2019-00233
" CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING
DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All
construction must be in conformance with the international codes as amended and adopted by Mason County. Any
corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting
additional inspections.
* Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and
MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either
private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an
existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance
and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting
from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any
construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that
office to review future planned work which may affect your project.
* The approval of this project is subject to the recommendations and specifications outlined in the attached geotechnical
report or assessment. All applicable recommendations and specifications shall be applied to the development on this site.
Any deviation requires stamped written approval from the registered design professional responsible for the
report/assessment, and may require special inspection by same. Structures and/or land modifications (grading, cuts, fills,
etc.) required in the geotechnical report/assessment, may require a separate permit. The geotechnical report/assessment
shall remain attached to the approved building plans.
* Application acknowledges that the structure is only permitted for a use consistent with the current zoning of the parcel.
RR5
* Height of structure not to exceed 35 feet from average grade.
* PER MCC8.52.170(E)(2) no clearing of native vegetation within 35 of the OHWM of the lake.
* If tree and/or vegetation removal is proposed in areas>40% slope please provide an addendum to the Geological
Assessment prepared by the engineer stating that the hazards of the landslide area can be overcome in such a manner as to
prevent harm to property and public health and safety, and also assure the project will cause no significant environmental
impact.
* On-site Septic System professional inspection required prior to temporary/final occupancy of the residence.
1 hereby certify that I have read and examined this application and know the same to be true and correct.
All provisions of Laws and Ordinances governing this type of work will be complied with whether
specified herein or not. The granting of a permit does not presume to give authority to violate or cancel
the provision of any ot7ata oca a ulating construction or the performance of construction.
r
Issued B '
Contractor or Authorized Agent: Date:
Printed by:Ariane Paysse on:05/13/2019 01:21 PM
Page 6 of 6
i
Mason County
/ \` Mason County - Division of Community Development
615 W. Alder St. Bldg.8
Shelton, WA 98584
- 360-427-9670 ext 352
www.co.mason.wa.us
B DD2019-00233 NEW SINGLE FAMILY RESIDENCE
PROJECT DESCRIPTION: NEW 1606 SQ FT 2-STORY SFR ISSUED: 05/13/2019
SITE ADDRESS: 260 NE LAKERIDGE DR BELFAIR
EXPIRES: 03/09/2020
PARCEL: 223047690130
APPLICANT: RAYMOND BISSER OWNER: RAYMOND BISSER
PO BOX 168 PO BOX 168
ALLYN,WA98524 ALLYN,WA98524
VALUATIONS: FEES: Paid Due
R-3 VB Residential, one- 1080.00 $130,410.00 Building Permit Fee $1,746.08 $0.00
and two-family Change in Tenant-Minor EH $110.00 $0.00
Covered Deck/Carport 576.00 $12,672.00 Plan Review
R-3 VB Residential, one- 526,00 $63,514.50 Plumbing Base Fee $25.00 $0.00
and two-family Planning Review Fee $240.00 $0.00
Mechanical Fees $160.00 $0.00
Mechanical Base Fee $30.00 $0.00
Plan Check Fee $1,134.95 $0.00
State Fee-Residential $6.50 $0.00
Plumbing Fees $122.00 $0.00
Mechanical Base Fee $10.00 $0.00
Total: $206,596.50 Totals : $3,584.53 $0.00
FIXTURES
(sty Mechanical Fixtures gty Plumbing Fixtures
1.0000 Gas Outlet(s) (1-5) 1.0000 Number of Clothes Washers
1.0000 Dryer Vent(s) 1.0000 Number of Dishwashers
1.0000 Kitchen Exhaust Hood(s) 1.0000 Number of Kitchen Sinks
1.0000 Ductless Heat Pump 1.0000 Number of Showers
1.0000 Propane Tank(s) 1.0000 Number of Water Heaters and or Vent
Printed by:Genie Mcfarland on:12/30/2019 02:39 PM
Page 1 of 7
P
T (n T T (n n 00
o m c O O D m `'I
C n 3 ci ° a z z
z a � -i 0 3
S = m
n n
C 1 p y m a z 0 0
CD 'p 2 n cD
Co � O
_ r. m
m O n D N W
0 z m O rp
N
m
O � o
r Z W
J \ 0 (.0
Z' O
11 ^ W
Cl) O W
�- w
cn
---� m
C o v
r �
I
o
3 r' D D cil
m v v -o -o
z _
y m m m L. `O D Z
_ �'n^
` cn Vi n n V
-0 O O v D m v 1 rn
c V
,..� �
c W 0 O 0
0 � C� N W (A
W X ;o m o -� o- O
cn
QO.ram v (a v
T S O fn c90
�^ —I
O
W- p 2. ; z 0 0 � 0
lA 3 z cD
E z rn W O
L n+ M m 0 Z (n N
p 7 m
O N O
° D z
v D v
D
0 0 n OD
cn
-I fD A
� N 0
c
0 CD
Cl)
>*
m 00
cn
N
2 = O0
T O O
M V z z
to m m
_ o o PLANNING In
�O (V in 1tl
d'
310,
W
Sep is Tanks & Drainfield N }
'^-140' N •L
O
3 Feway & Parking A
Fr
7
LuIF m
o
8' 30' 6'i
46'
N
�ater Line & Meter Box
Power Line
RECEIVED SITE PLAN SCALE 1 " = 40'
MAR 14 2019
5i 0 NE Lakerid a Drive, Belfair, 1Na. N
615 W. Alder street PLANNING: A P'= " ' -D
All SETBACKS ARE MEASURED MASON COUNTY DCD PL,^,NNI G
FROM THE FURTHEST SITE PL, N REQUIRED TU BE Ulv sr p
PROJECTION OF THE BUILDING ES SUBJECT TO
BY Date
51te Address:
5ELBY DESIGN LTD DESIGN FOR: P e
a
'1'192 Holly Park Gt NW W 260 NE Lakerid Drivel,Bremerton, a 98312 � 9 March 4 2019
UUW.selbydeslgnitd.com 360-649-1826 Raymond Chase Bisser Belfair, lNa.
iy
Name �l '!� Parcel# 2-SO Y —7w --( 0/5%LD# 24biq — 00Z✓
Mason County �V I
Department of Community Developmen
LDING
Small Parcel Stormwater Management Application/Worksheet (page 1 of 2)
Per Mason County Code, Title 14, Chapter 14.48 a stormwater site plan is required whenever a building application is
made for residential development, or redevelopment',with more than 2,000 square feet of impervious surface'.
'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development
including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not
part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment.
'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas,
concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the
natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces.
To Calculate Impervious Surfaces Please Complete This Table
Surface Type Length X Width = Area *All dimensions in feet
Buildings X y = 0
X = Measurements for buildings are taken at the
X _ perimeter of the farthest projections (example:
eaves/gutters)
X =
Driveways X =
X = Length of drive begins at the right of way
X =
Parking Areas X =
X = Any paved, gravel or packed area per definition
above table
X =
Patios/Walks X
X = Any paved, gravel or packed area per definition
above table
X =
Others X =
X If the total impervious area of the proposed site
X = development is greater than 2000 square feet a
Small Parcel Stormwater Site Plan is Required
r7Total Impervious Surface Area(sum of all areas)
If the Total Impervious Surface Area is LESS T N 2000 S are Feet,please read,acknowledge and sign below.
Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required.
X Owner/Agent/Contractor(circle one)Date:
If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please RIsign
the information provided on page 2 of 2. REfeEPOEV
Page I of 2 MAR 14 2019
615 W.Alder Street
Name Parcel# BLD#
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 2 of 2)
Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity.
Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater
Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website:
http//www.co.mason.wa—us/code/commissioners/index.htm
Please follow the links to "Title 14,Chapter 14.48 Stormwater Management".
Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan
(Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document
entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist
you in preparing the necessary information and plans for Public Works to review and approve. Per Department of
Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in
their entirety AND no part of the stormwater system adversely affects any septic system (see Environmental Health
information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval.
A design by a registered professional may be required for more complex sites.
*These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan
on the pages that begin with"Handout"
PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE
A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed
in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel.
B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the
system will be located as not to adversely affect any septic systems on this,or any other,parcel.
If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works
Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at:
Phone: 360-427-9670 ext 450
100 W.Public Works Dr
Shelton.WA 98W
If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or
any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason
County Division of Environmental Health can be reached at:
Phone: 360-427-9670 ext 400
415 N. 6th St— Bldg#8 lower level
Shelton.WA 98584
A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met
prior to a request for final inspection of the building permit.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required.
X Owner/Agent/Contractor(circle one)Date:
Page 2 of 2
(R-2 occupancy is Residential occupancies containing sleeping units or more than two dwelling
units where the occupants are primarily permanent in nature, including:
Apartment houses, Boarding houses (non-transient) with more than 16 occupants, Congregate
living facilities (non-transient) with more than 16 occupants, Convents, Dormitories, Fraternities and'
sororities, Hotels (non-transient), LiveAvork units, Monasteries, Motels (non-transient), Vacation
timeshare properties.)
c) Large dwelling unit is a dwelling unit that exceeds 5,000 sq. ft. of heated or cooled floor area.
Requires 4.5 credits.
d) Additions less than 500 sq feet. Requires .5 credits
4 Must provide a completed heating/cooling system size worksheet to verify compliance to IECC R403.7.
The calculator/worksheet is available on the WSU-Energy Program website at:
http-://www.energy.wsu.edu/Documents/Heat Sizing code%20specs final 2015.xis. Staff may be able to
assist with preparation of the worksheet.
5 Must meet the prescriptive option for all fenestration products. Products shall comply with the required U-
factor listed in Table R402.1.3. Windows, doors, and glazed doors shall have a tested U-factor or .30 or
less. When using the small dwelling option for energy credits (a) or Performance Alternative approach
you must provide a fenestration schedule that identifies the square feet and U-factor of each item.
Fenestration is defined in the IECC as skylights, roof windows, vertical windows, opaque doors, glazed-
doors that include products with glass and non-glass glazing materials.
6 Identify on the construction drawings the location and fuel type of the heating system, water heater,
location of exhaust fans (bathroom, laundry, kitchen, etc.) and R-factor of proposed insulation for walls,
floors, ceilings, and concrete slab floors on the building plans.
7 Not less than 75% of all permanently installed lamps in lighting fixtures shall be high efficacy lamps.
High efficacy lamps are defined in IECC Chapter 2 and are considered compact fluorescent lamps, T-8
or smaller diameter linear fluorescent lamps, or lamps with a minimum efficacy 60 lumens per watt for
lamps over 40 watts, 50 lumens per watt for lamps over 15 watts to 40 watts, and 40 lumens per watt for
lamps 15 watts or less.
If you need assistance please contact Mason County Community Development at (360) 427-9670 ext. 352 or
WSEC compliance information and code text is also available on the WSU-Energy Program website at:
�http://www.energy.wsu.L-du/BuildingEfficiency/EnerqvCode.aspx)
Prescriptive Requirements °,' for Mason County
Climate Zone 4-C, Table R402.1.1
Fenestration
Glazing U-factor Wall d
Area % Vaulted Wall Slab on
Vertical Skylight g g Above
Option of FloorCeiling Ceiling Grade int�,n below grade Floor Grade
(inoludes doors, b
windows.etc.) R-10,2 ft
4C Unlimited .30 .50 R-49 R-38 R-21 10/15121 int+ R-30 Heated slabs
int TB require R10
full slab.
n Log & solid timber wall with a min. avg. thickness of 3.5" are exempt from the above grade wall insulation
requirements. All footnotes are available on WSU-Energy Program Website @
htti)i//www.ener_qy.wsu.edu/BuildingEfficiency/Energy0odc-.aspx RECEIVED
MAR 14 2019
N�
615 W.Alder Street
2
MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT
WSEC/ Ventilation Code Compliance Application
Submit with heating/cooling system size worksheet (see instructions #4)
Owner: Parcel#: Type of project:
�fo ; 5 S C r %2,3o"I -1 6 - �I k0&\' -
Total Sq. Ft. Is' Floor: 211 floor. Heated Basement:
of heated area:: i Q p
Heating System Type: O Electric wall heater O Electric Central Furnace O LPG Furnace
O Heat Pump with electric furnace O Heat pump with gas furnace �) Ductless Heat Pump
O Boiler, specify fuel type: O Other.
Specify:
4 Prescriptive Option Table R402.1.1 (see table on previous page)
Compliance ❑ Component Performance, R402.1.3 — Calcula6on worksheets required
Method
Must Check one::
❑ Other (specify):
Check one [j� whole House Ventilation system ElWhole House Ventilation
Ventifatio using exhaust fans &window or wall Integrated with a Forced Air El Other,describe:
fresh air vents (M1507.3.4). If using System (M1507.3.5)
n System window vents be sure to order
windows with vents.
Referencing Table R406.2, "Additional Residential Energy Efficiency Requirements," all residential units
must develop credits as specified in Table 406.2. Identify and describe which option(s)will be used to
comply. If the table is not attached to this form you can access the table on our website at
httpi//www.co.MaSDn.wa.us/forms/Community Devfiecc wsec.pdf
Additional a) Description: Small dwelling units: less than 1,500 sq. feet of heated or cooled floor
area and less than 300 sq. ft fenestration area (skylights, doors, windows, etc).
Energy *Including additions to existing building that are greater than 500 sq. ft. of heated floor
Requir
Eftquir em cy but less than 1,500 sq ft of floor area. Requires 1.5 credits
ents b) Medium dwelling units that are not included in (a) above {small dwelling}, OR (c) below
Energy {large dwelling} Requires 3.5 credits
credits
EXCEPTION: Dwelling units serving R-2 occupancies shall require. Requires 2,5
required. credits. See page two for description.
c) Large dwelling unit is a dwelling unit that exceeds 5,000 sq. ft. of heated or cooled
floor area. Requires 4.5 credits
d) Additions less than 500 sq feet. Requires .5 credits
(Fenestration is defined in the IECC as skylights, roof windows, vertical windows, opaque
doors, lazed-doors that include products with glass and non-glass glazing materials.
Describe Energy Credit Option(s):
Using Option I C C9- S C'-c�-i ,F S
number(s): 3 a — I 0
C nw ;vs
3,6
3
FENESTRATION'SCHEDULE
USE FOR ENERGY CREDIT a) SMALL DWELLING OPTION & COMPONENT PERFORMANCE COMPLIANCE
List all windows, doors, skylights. (If needed, attach an additional sheet)
'Fenestration is defined in IECC Chapter 2 as skylights, roof windows, vertical windows, opaque doors, glazed-doors
that include products with lass and non- lassglazing materials.
Manufacturer Location U-Factor Size Quantity Total
rough opening)
Square Feet
Total Fenestration: windows, skylights and door area
Energy Credits
4
(2015 WSEC -- Table 406.2)
OPTION DESCRIPTION CREDIT(S)
l a EFFICIENT BUII DING ENVELOPE l a: 0.5
Prescriptive compliance is based on Table R402.1.1 with the following modifications:
Vertical fenestration U =0.28
Floor R-38
Slab on grade R-10 perimeter and under entire slab
Below grade slab R-10 perimeter and under entire slab
or
Compliance based on Section R402.1.4: Reduce the Total UA by 5%.
lb EFFICIENT BUILDING ENVELOPE lb: 1.0
Prescriptive compliance is based on Table R402.1.1 with the following modifications:
Vertical fenestration U =0.25
Wall R-21 plus R-4
Floor R-38
Basement wall R-21 int plus R-5 ci
Slab on grade R-10 perimeter and under entire slab
Below grade slab R-10 perimeter and under entire slab
or
Compliance based on Section R402.1.4: Reduce the Total UA by 15116.
1 c EFFICIENT BUIIDING ENVELOPE 1 c: 2.0
Prescriptive compliance is based on Table R402.1.1 with the following modifications:
Vertical fenestration U =0.22
Ceiling and single-rafter or joist-vaulted R-49 advanced
Wood frame wall R-21 int plus R-12 ci
Floor R-38
Basement wall R-21 int plus R-12 ci
Slab on grade R-10 perimeter and under entire slab
Below grade slab R 10 perimeter and under entire slab
or
Compliance based on Section R402.1.4: Reduce the Total UA by 30 .
Id' EFFICIENT BUILDING ENVELOPE 1 d: 0.5
Prescriptive compliance is based on Table R402.1.1 with the following modifications:
Vertical fenestration U=0.24
2a AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2a: 0.5
Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per
hour maximum
and
All whole house ventilation requirements as determined by Section M15073 of the
International Residential Code shall be met with a high efficiency fan(ma)imum 0.35
watts/cfm�not interlocked with the furnace fan.Ventilation systems using a furnace
including an ECM motor are allowed,provided that they are controlled to operate at
low speed in ventilation only mode.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the maximum tested building air leakage and shall
show the qualifying ventilation system.
2b AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2b: 1.0
Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 2.0 air
changes per hour maximum
and
All whole house ventilation requirements as determined by Section M15073 of the
International Residential Code shall be met with a beat recovery ventilation system
with minimum sensible heat recovery efficiency of 0.70.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the maximum tested building air leakage and shall
show the heat recovery ventilation system
5
OPTION DESCRIPTION CREDIT(S)
2c AIR LEAKAGE CONTROL AND EFFICIENT VENTIl_kTION 2c: 1.5
Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 1.5 air
changes per hour maximum
and
All whole house ventilation requirements as determined by Section M1507.3 of the
International Residential Code shall be met with a heat recovery ventilation system
with minimum sensible heat recovery efficiency of 0.85.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the maximum tested building air leakage and shall
show the heat recovery ventilation system
3a° HIGH EFFICIENCY HVAC EQUIPMENT 3a: 1.0
Gas,propane or oil-fired furnace with minimum AFUE of 94°/%or
Gas,propane or oiled-fired boiler with minimum AFUE of 92%
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the heating equipment type and the minimum
ui ment efficiency.
3b HIGH EFFICIENCY HVAC EQUIPMENT 3b: 1.0
Air-source beat pump with minimum HSPF of 9.0
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the beating equipment type and the minimum
went efficiency.
3c HIGH EFFICIENCY HVAC EQUIPMENT 3c: 1.5
Closed-loop ground source heat pump;with a minimum COP of 3.3
or
Open loop water source heat pump with a maximum pumping hydraulic head of 150
feet and minimum COP of 3.6
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the heating equipment type and the minimum
equip ment efficiency.
3d HIGH EFFICIENCY HVAC EQUIPMENT 3d: 1.0
Ductless Split System Heat Pumps,Zonal Control:In homes where the primary space
heating system is zonal electric heating,a ductless heat pump system shall be installed
and provide heating to the largest zone of the housing unit.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the heating equipment type and the minimum
equipment efficiency.
4 HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM: 1.0
All heating and cooling system components installed inside the conditioned space.
This includes all equipment and distribution system components such as forced air
ducts,hydronic piping,hydronic floor heating loop,convectors and radiators.All
combustion equipment shall be direct vent or sealed combustion.
For forced air ducts:A maximum of 10 linear feet of return ducts and 5 linear feet of
supply ducts may be located outside the conditioned space.All metallic ducts located
outside the conditioned space must have both transverse and longitudinal joints sealed
with mastic.If flex ducts are used,they cannot contain splices.Flex duct connections
must be made with nylon straps and installed using a plastic strapping tensioning tool.
Ducts located outside the conditioned space must be insulated to a minimum of R-8.
Locating system components in conditioned crawl spaces is not permitted under this
option.
Electric resistance heat and ductless heat pumps are not permitted under this option.
Direct combustion heating equipment with AFUE less than 80%is not permitted
under this option.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the heating equipment type and shall show the
location of the beating and cooling equipment and all the ductwork
6
OPTION DESCRIPTION I CRED7(S)
Sa EFFICIENT WATER HEATING Sa:
All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75
GPM or less.All other lavatory faucets shall be rated at 1.0 GPM or less.'
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the maximum flow rates for all shower-heads,kitchen
sink faucets,and other lavatory faucets.
5b EFFICIENT WATER HEATING 5b: 1.0
Water heating system shall include one of the following-
Gas,propane or oil water heater with a minimum EF of 0.74
or
Water heater heated by ground source heat pump meeting the requirements of Option
3 c.
or
For R-2 occupancy,a central heat pump water beater with an EF greater than 2.0 that
would supply DHW to all the units through a central water loop insulated with R-8
minimum pipe insulation.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the water heater equipment type and the minimum
equipment efficiency.
5c EFFICIENT WATER HEATING 5c: 1.5
Water heating system shall include one of the following-
Gas,propane or oil water heater with a minimum EF of 0.91
or
/ Solar water heating supplementing a minimum standard water heater.Solar water
,X> heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the
Solar Rating and Certification Corporation(SRCC)Annual Performance of OG-300
Certified Solar Water Heating Systems
or
Electric beat pump water heater with a minimum EF of 2.0 and meeting the standards
ofNEERs Northern Climate Specifications for Heat Pump Water Heaters
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the water heater equipment type and the minimum
equipment efficiency and,for solar water heating systems,the calculation of the
minims energy savings.
5d EFFICIENT WATER HEATING 5d: 0.5
A drain water heat recovery unit(s)shall be installed,which captures waste water heat
from all the showers,and has a minimum efficiency of 40%if installed for equal flow
or a minimum efficiency of 52%if installed for unequal flow.Such units shall be
rated in accordance CSA B55.1 and be so labeled.
To qualify to claim this credit,the building permit drawings shall include a plumbing
diagram that specified the drain water heat recovery units and the phimbing layout
needed to install it and labels or other documentation shall be provided that
demonstrates that the unit complies with the standard.
6 RENEWABLE ELECTRIC ENERGY: 0.5
For each 1200 kWh of electrical generation per each housing unit provided annually
by on-site wind or solar equipment a 0.5 credit shall be allowed,up to 3 credits.
Generation shall be calculated as follows:
For solar electric systems,the design shall be demonstrated to meet this requirement
using the National Renewable Energy Laboratory calculator PVWATTs.
Documentation noting solar access shall be included on the plans.
For wind generation projects designs shall document annual power generation based
on the following factors:The wind turbine power curve;average annual wind speed at
the site;frequency distribution of the wind speed at the site and height of the tower.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall show the photovoltaic or wind turbine equipment type,
Provide documentation of solar and wind access,and include a calculation of the
minimum annual energy power production.
a.Projects using this option may not use Option la,lb or It.
b.Projects may only include credit from one space heating option,3a,3b,3c or 3d.When a housing unit has two pieces of
equipment(Le.,two furnaces)both must meet the standard to receive the credit
r—Plumbing Fixtures Flow Ratings Low flow plumbing fixtures(water closets and urinals)and fittings(faucets and
showerbeads)shall comply with the following requirements:
1.Residential bathroom lavatory sink faucets:Maximum flow rate-3.8 L/min(1.0 gal/min)when tested in accordance
with ASME A1a18.1/CSA B125.1.
2.Residential kitchen faucets:Maximum flow rate-6.6 L/min(1.75 gal/min)when tested in accordance with ASME A112.1&VCSA B125.1.
3.Residential showerbeads:Maximum flow rate-6.6 L/min(1.75 gal/min)when tested in accordance with ASME A112.18.VCSA B125.1
7
MASON COUNTY RECEIVED
COMMUNITY SERVICES
v,
Building,Planning,Environmental Health,Community Health MAR 14 2019
DIAI
Physical and Mailing Address: 615 W Alder St., Bldg 8, Shelton, WA 98584 0 615 W.Alder Street
Shelton Phone: (360)427-9670 ext 352 ❖ Fax (360)427-7798 Q �f)
PLUMBING & MECHANICAL PERMIT APPLICATION Permit#: V a" I q
rXZ33
OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME: &4o- ura. - & SSe'r - NAME'
MAILING AD ESS: `Q0 Q)OX WB MAILING ADDRESS:
CITY: N\\yr\ STATE: \Jh ZIP: 5Z-4 CITY, STATE: ZIP:
1st PHONE: .j(00 go\- `'it)6 1 PHONE: CELL:
2nd PHONE: 360 - $ol — Di'b"A ' EMAIL:
EMAIL: L&I REG# EXP.
PARCEL INFORMATION: 1
PARCEL NUMBER (12 Digit Number): `� 3 oy u q h 13 0 Zoning:
LEGAL DESCRIPTION (Abbreviated):
SITE ADDRESS: Zh Q L G,LAc, I?i cam,e_ L*)r, CITY: _ged���r
DIRECTIONS TO SITE ADDRESS:
TYPE OF JOB/WORK: NEW�_ ADD ALT REPAIR OTHER
USE OF BUILDING Qe,c'rr\c_&n k �t5iden d c.
PLUMBING FIXTURES MECHANICAL UNITS [] Electric in-wall heaters (no fee)
Type of Fixture No. of Fixtures Fuel Type Fees Type of Unit No. of Units Fuel Type Fees
Toilet(s) � Furnace [E/G/LPG]
Bathroom Sink(s) Heat Pump [E/G/LPG]
Bath Tub(s) 'v O Ductless H.P. 1 OE G/LPG]
Shower(s) 1 —Spot Vent Fan
Water Heater(s) 1 &{ /LPG] Propane Tank --- L_gal.]
Clothes Washer(s) 1 IPG/LPG] Gas Outlet(s)
Kitchen Sink(s) I Heat Stove [E/G/LPG/W]
Dishwasher(s) I Kitchen Exhaust Hood
dose bib(s) _ Dryer Vent 1
Other Solar Panel
Other Other
Plumbing Subtotal Mechanical Subtotal
Plumbing Base Fee Mechanical Base Fee
Final Inspection Fee Final Inspection Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is
by signature below. I declare that I am the owner, owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to
do the work as proposed.I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this
project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above
described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not
commenced within 180 days or if construction work is suspended for a period of 180 days.PROOF OF CONTINUATION OF WORK IS BY MEANS OF
INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
X ple/illse4, ;
Signature of Applicant Date
X 1Za�v 6,sh e,r Owner/Owners Representative/Contractor
Prin Name (Circle one)
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
O Building ,2S'
O Fire Marshal
O Permit Tech (OTC permit only)
;Si: i"t: :n-'i h j: ,'�1/1Rrortl+-CO.I'?u5p;�.Wd.U�'C�nl'1 'Jn(iV_CtE'V� hev 2 7
Simple Heating System Size: Washington State
This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA
Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling
loads.
Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,
some values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension
Program at(360)956-2042 for assistance.
Project Information Contact Information /
RAYMOND BISSER
BLD2019-00233
L_
Heating System Type: 0411 Other Systems Q-leat Pump
To see detailed instructions for each section,place your cursor on the word'Instructions".
Design Temperature
Instructions --.:.--..- -..-.- - Design Temperature Difference(AT) 41
Bremertonlum " AT=Indoor(70 degrees)-Outdoor Design Temp
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area(scl ft) 1,606
Average Ceiling Height Conditioned Volume
Instructions Average Ceiling Height(ft) 10.0 16,060
Glazing and Doors U-Factor X Area = UA
Instn.�cticn, .—
0.280 288 80.64
Skylights U-Factor X Area = UA
Inst:iii,hr;"` 0.50 ---
Insulation
Attic U-Factor X Area = UA
(w4m,'tiun, 0.026 830 21.58
R49 �
Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA
lnsEructSons l _____.._..
R-49-Advance.__ d 0.020 250 5.00
Above Grade Walls(see Figure1) U-Factor X Area UA
r caon� — 0.056 1,505 84.28
R-21 Intermediate
Floors U-Factor X Area UA
0.025 1,080 27.00
Below Grade Walls(see Figure 1) U-Factor X Area UA
InsiructSoris No selection --
Select R-value �
i
Slab Below Grade(see Figure'0 F-Factor X Len th UA
Instructions _ _ .____._. .. -__--_._
Select conditioning No selection 0 I ---
Slab on Grade(see Figure 1) F-Factor X Len th UA
Instructions
Select R-value NO Selection ! J ---
Location of Ducts
l,strucnons — ._ - Duct Leakage Coefficient
Unconditioned Space 1.10
Sum of UA 218.50
Envelope Heat Load 8,959 Btu/Hour
Figure 1. Sumof UAXAT
Air Leakage Heat Load 7,111 Btu/Hour
Volume X 0.6 X pT X.018
Above Grade Building Design Heat Load 16,070 Btu/Hour
+..� Air Leakage+Envelope Heat Loss
Building and Duct Heat Load 17,677 Btu/Hour
Duds in unconditioned space:Sum of Building Heat Loss X 1.10
Duds in conditioned space:Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 22,096 Btu/Hour
Building and Duct Heat Loss X 1.40 for Forced Air Fumace
Building and Duct Heat Loss X 1.25 for Heat Pump
(07101113)
MASON COUNTY COMMUNITY SERVICES I
E:.
� p PERMIT ASSISTANCE CENTER: Permit No:
-a •BUILDING•PLANNING•PUBLIC HEALTH.FIRE MARSHAL �yJ; �f d,3DM Z
615 W.Alder Street,Shelton,WA 98584 l
RECEIV
- Phone Shelton:(360)427-9670 ext 352•Fax:(360)427-7798 Phone ED
Belfair.•(360)275-4467•Phone Elms:(360)482-5268
l� �SaI
• BUILDJKMNG PERMIT APPLICATION MAR 14 2019-.
PROPERTY OWNER INFORMATION: CONTRACTOR INFORTRAONAIder Street
NAME: V_&wnpn 6%SSe t^ NAME:
MAILING DRESS: 90 S 0 X 1 b S MAILING ADDRESS:
CITY: AAkkl K STATE:�JN-, ZIP: SZ,4 CITY: STATE: ZIP:
PHONE- #I: 360- 190 1-y b(01 PHONE: CELL:
PHONE#2: 360 - 901 - OVVA EMAIL :
EMAIL: C")D':c_S hn+Nr~"•Co^ L&I REG# EXP.
PRIMARY CONTACT: OWNER CONTRACTOR❑ OTHER
NAME C&M,nr, t55t-e— EMAIL r- SSc( Q •F ° I •Gots
MAILING f tT[ ESS �T f,D)G IGs CITY R1iT_STATE �zh- ZIP ��sZ
PHONE C6 -- w I —4061 CELL
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number) ' �c0 O'� —7 0 3 ® ZONING
LEGAL DESCRIPTION(Abbreviated) FIRE DISTRICT
SITE ADDRESS Z(oQ L°J4Q- TA, �f_ 9C , CITY 60f-pJr
DIRECTIONS TO SITE ADDRESS
IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES❑ NO ❑
IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply):
SALTWATER❑ LAKE ❑ RIVER/CREEK❑ POND❑ WETLAND ❑ SEASONAL RUNOFF ❑ STREAM❑
-TYPE OF WORK: NEW ADDITION ❑ ALTERATION ❑ REPAIR❑ OTHER ❑
USE OF STRUCTURE(Residence,Garage,Commercial Bldg,Lte) F_25r Ji-e n C e.
IS USE: PRIMARY PS SEASONAL❑ NUMBER OF BEDROOMS 3 NUMBER OF BATHROOMS Z
HEATED STRUCTURE? YES(Whole Bldg) YES (Part[s]of Bldg) ❑ NO ❑
DESCRIBE WORIC
SQUARE FOOTAGE: (propose+existing)
IST FLOOR I�sq.It. 2ND FLOOR 5Z6 sq.ft. 3RD FLOOR sq. ft. BASEMENT sq.it.
DECK sq.ft. COVERED DECK. S"7 sq.ft. STORAGE sq.ft. OTHER sq.ft.
GARAGE sq.ft. Attached❑ Detached❑ CARPORT sq.ft. Attached❑ Detached❑
MANUFACTURE'D HOME 029EM N: *4 COPIES OF THE F R PLAN
'�AKE MODEL YEAR LENGTH
WI DROOMS BATHS SE ER
ENVIRONMENTAL HEALTH:
SEWAGE/SEWER SOURCE: SEPTIC SEWER❑ / NEW❑ EXISTING [�
PLUMBING IN STRUCTURE? YES NO ❑ Ifyes, attach completed Water.Adequacy Form
PERIMETER/FOUNDATION DRAINS PROPOSED? YES ❑ NO❑ EXISTING SQ.FT.
EXISTING BEDROOMS PROPOSED BEDROOMS TOTAL BEDROOMS
OWNER acknowledges that submission of Inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by
signature below.1 declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have
obtained permission from all the necessary parties,Includiing any easement holder or parties of interest regarding this project. The owner or legal
representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property.
and structure(s)for review and inspection. This permittapplication becomes null&void if work or authorized construction Is not commenced within 180
days or if construction work is suspended for a period of 180 days.
PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. .INACTIVITY.OF THIS
PERMIT APPLICATION OF 180 DAYS OF MORE WILL-CAUSE THE APPLICATION TO BE EXPIRED.(MASON
COUNTY CODE 14.08.42)
Sig ature of OWNER(Must be signed by the OWNER) Date
DEPARTMENTAL Ri,VIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
PUBLIC HEALTH
I