HomeMy WebLinkAboutBLD2019-01276 Final MFG Home - BLD Permit / Conditions - 7/27/2020 Mason County s, Mason County - Division of Community Development 5 W.Alder St. Bldg. Shelton,WA 98584 360-427-9670 ext 352 www.co.mason.wa.us FPROJECT 9-01276 MANUFACTURED HOME ESCRIPTION: NEW MFG HOME ISSUED: 03/11/2020 ESS: 510 E SHERWOOD CREEK RD ALLYN EXPIRES: 09/07/2020 PARCEL: 122301190090 APPLICANT: JAN&THERESA OOSTERVELD OWNER: JAN&THERESA OOSTERVELD PO BOX 1709 PO BOX 1709 PORT ORCHARD,WA98366 PORT ORCHARD,WA98366 360-443-6937 GENERAL CONTRACTOR'S LICENSE: GB CONSTRUCTION GENERAL CONTRACTORS License: GBCONCG811 PU LLC Expires: 11/01/2021 2430 PUGET SOUND BLVD BREMERTON,WA98312 1.360.277.7362 VALUATIONS: FEES: Paid Due Covered Deck/Carport 104.00 $2,288.00 Planning Review Fee $240.00 $0.00 Building Plan Review/Change of $110.00 $0.00 Use-Onsite Sewage State Fee-Residential $6.50 $0.00 Modular/Manufactured Home $275.00 $0.00 Fee-2nd half collected at ready to issue Modular/Manufactured Home $275.00 $0.00 Fee- 1st half collected at submittal Covered Deck Fee $80.00 $0.00 Building Permit Fee $156.00 $0.00 GEOTECHNICAL ASSES. $300.00 $0.00 REPORT REV Total: $2,288.00 Totals : $1,442.50 $0.00 REQUIRED INSPECTIONS Printed by:Genie Mcfarland on:03/11/2020 10:45 AM Page 1 of 4 Mason County Mason County - Division of Community Development 615 W.Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us MANUFACTURED HOME BLD2019-01276 Setback Inspection Footing Inspection Footing Inspection Framing Inspection Set-Up Inspection BLD-Final Inspection CONDITIONS * Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. * Concrete used for basement walls,foundation walls,exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). * By definition, propane tanks and heatpumps are structures,which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed. * The installation permit shall be displayed in clear view of the site access road. The approved site plan and other applicable instructions, including installation instructions, shall be available in this location OR placed in the location specified by WAC 296-150M-655. Support configuration shall be clearly marked in the installation instructions. * All property lines shall be clearly identified at the time of foundation inspection. * Any retailer, manufacturer or contractor who installs a manufactured home warrants that the manufactured home is installed in accordance with the State Installation code, chapter 296-150M WAC. All installers hired to do installation work shall be certified manufactured home installers and shall be present to supervise the installation of all on-site work. An Installer Tag shall be posted on site giving the certification number and signature of the certified installer responsible for each major part of the installation. RCW43-63B.090 An approved Installer verification tag shall be placed on the end of the manufactured home directly above or below the HUD certification tag or temporarily located in plain site within three feet of the home's front entry. There shall be one certification tag for each certified installer accounting for the work that each installer performed or installed. Certification number and signature of the certified installer responsible for each major part of the installation.WAC365-210 * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. * Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. * Mason County has four areas with ground snow loads between 25#-55#.The owner/agent of this permit acknowledges that if the unit permitted under this permit does not meet the area snow load rating, there is a potential for failure due to weight accumulation beyond that of the design criteria for the unit. If you are uncertain please contact Department of Community Services for snow load or vist our website at www.co.mason.wa.us. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. Printed by:Genie Mcfarland on:03/11/2020 10:45 AM Page 2 of 4 Mason County ra?�*,T_vj� Mason County Division of Community Development 615 W.Alder St. Bldg.8 Shelton,WA 98584 360-427-9670 ext 352 www.co.mason.wa.us MANUFACTURED HOME BLD2019-01276 * Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. * If you are installing a manufacturing home and no longer have the installation manual for the home, you must use the instructions of the American National Standards Institute (NCSBCS/ANSI A225.1). * REQUIRED INSPECTIONS (Footing Inspection-prior to pour(set-up manual must be on-site), Set-up Inspection-prior to skirting, Final Inspection-prior to occupancy). I hereby assume all responsibility for the scheduling of my required inspections. If the required inspections are not requested, inspected and signed off(approved)by the inspector in the prescribed order, I understand that reinspection fees and an hourly investigation fee pursuant to the current fees adopted by the Mason County Building Dept., and will be assessed in addition to my original permit fees to resolve any questionable practices or problems that have been discovered. Until resolution of any/all problems no occupancy(Final Inspection)will be granted for the residence. OWNER/CONTRACTOR(indicate which) * The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked "APPROVED",they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. * This permit is for the placement and installation of the manufactured home only and does not imply approval or review for any other items indicated on the plot plan. * All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way. * All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * The foundation/footing must be placed on undisturbed,firm-native soil. * All changes to"approved"building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. Printed by:Genie Mcfarland on:03/11/2020 10:45 AM Page 3 of 4 Mason County Mason County - Division of Community Development 615 W.Alder St. Bldg.8 Shelton,WA 98584 360427-9670 ext 352 www.co.mason.wa.us MANUFACTURED HOME BLD2019-01276 * A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled"Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan"constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. * When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at(360)427-9670, ext.450 or 100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. * Comply with recommendations of the Geo-Tech report. GE02020-00018. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: Contractor or A tho ized Agent:" Date: 3 /% Printed by:Genie Mcfarland on:03/11/2020 10:45 AM Page 4 of 4 r ' MASON, COUNTY 615 W.Alder St Bldg 8,SHELTON,WA 98584 I � COMMUNITY SERVICES SHELTON:360-427-9670,EXT 352 BELFAIR:360-275- 467,EXT 352 Bu ldiniA Planning,Environmental Health.Ct unity Health ELMA:360-482-5269,EXT 352 www.co.mason.wa.us INSPECTION CARD AND CERTIFICATE OF OCCUPANCY" To schedule an Inspection call or visit httpJ/www.co.mason.wa.us/community-servicestbid-inspecdon.php Permit Number BLD2019-01276 Date Issued 03/11/2020 Issued By Project NEW MFG HOME Site Address 510 E Sherwood Creek Rd Applicant JAN&THERESA OOSTERVELD Contractor GS CONSTRUCTION GENERAL CONTRACTORS LLC Contractor Phone 1.360.277.7362 Primary Code UPC IBC,IRC,IFC,IEC,IMC,& Type Permit Type MANUFACTURED HOME Occupancy -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS. -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED. -THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION,FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY. -ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION. -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION. "THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED"" PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET Public Works Access/Driveway Other Health Septic Well Deptartment Planning Site Inspection Department Fire Marshall Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final Building Building Official: Community Services Designee Department Concrete Setbacks Slab Footing Perimeter Point load Footing Footing Interior Footing Decks/Porches Foundation Stem Walls Other Rough-In Groundwork Plumbing Framing Groundwork Mechanical Plumbing Groundwork Gas Pipe Mechanical Gas Piping Shear Wall Nailing Underfloor Other Insulation Slab Ceiling Floor Vaulted Ceiling Walls Vapor Barrier Other Wallboard Interior Wall Brace Panels Fire Walls Nailing Other Final Building Manufactured Setbacks Setup Home 0 Home Concrete Foot/Runners S J') UJa A Final '� Other S� MASON COUNTY 360-427-9670 Shelton ext.352 352 COMMUNITY SERVICES 3660�82-5 69 Elmae ext.352 Building,Planning,Environmental Health,Community Health 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.co.mason.wa.us CORRECTIONANSPECTION REPORT PERMIT/CASE NUMBER::\6 9,0 F]- Dk a—1 ADDRESS/LOCATION:C: C3 C) FINDINGS: r r � r v� Z fibft WyWryecA pf-\ Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed ab ve are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OK to Date: Please contact our office regarding possible ❑ g g structural damage incurred b g Y recent Department: �� e _ natural/man made"disasters.This is NOT a Inspector: ,CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC 14.12 MASON COUNTY 360-427-9670 Shelton ext.352 COMMUNITY SERVICES 36 60-482-52 Belfair ext.352 360-482-5269 Elma ext.352 Building,Planning, Environmental Health,Community Health • 615 W. Alder St. Bldg.8 - Shelton,WA 98584 www.co.mason.wa.us CORRECTIONANSPECTION REPORT PERMIT/CASE NUMBER: �d ADDRESS/LOCATION: !S n (( �ey—`` Y" CL FINDINGS % -� f Q"7 se cAA 'G• Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. OK to �.P,nr7\— Date: 1` ❑ Please contact our office regarding possible Department: -, NCA structural damage incurred by recent "natural/man made"disasters.This is NOT a Inspector: - } �� CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY COMMUNITY SERVICES P o: • d Ia—?Q 07 PERMIT ASSISTANCE CENTER: ��-.1tm• • , •BUILDING.PLANNING•PUBLIC HEALTH.HRE MARSHAL 615 W.Alder Street,Shelton,WA98584 �O\I 10V Phone Shelton:(360)427-9670 ext.352•Fax:(360)427-7798 Phone1 3 Z�19 BeNair.(360)275.4467•Phone Elma:(360)482-5269 BUIL0 , BUILDING PERMIT APPLICATI&5 W. Alder Street _ 615_ W. Alder Sii op t PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: v 1 /1 NAM • A 6 G NAME: `O S LLC MAIL ADDRESS: MAILING ADD SS: • c VI.,4 t CITY: STA 7. CITY STATE: Zip: ?` , PHONE#I: ef��� PHONEW CELL: PI PONE#2: EMAIL: AA, i EMAIL L&I PRIMARY CONTACT: OWNER❑ CONTRACTOR 0 HER NAME EMAIL MAILING ADDRESS CITY���r_h, STATE i4LO,­Z1Pq�7 PHONE CELL PARCEL INFORMATION: ^� Q PARCEL NUMBER(12 Digit Number) t qa d 36 -1 (�7 ZONING " LEGAL DESCRIPTION(Abbreviated) .97 Ivaf,7Q 39 IV T KIRE DISTRIC:T`. SITE ADDRESSt5f Q E S CrZL3. T Y IVAI DIRECTIONS TO SITE ADDRESS '(- IS TILE PROJECT WITHIN 300 FT OF SLOPES)GREATE THAN 14%: YES*"NO❑ IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Cheat all that apply): SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ TYPE OF WORK: NEW(ADDITION❑ ALTERATION❑ . REPAIR❑ OTHER ❑ USE OF STRUCTURE(Residentr,Garage.Commervial Bldg,Fic.), IS USE: PRIMARY Nk-gEASONAL❑ NUMBER OF BEDROOMS__ NUMBER OF BATHROOMS_ HEATED STRUCTURE? YES/Whale Bidg)na YES(Parrlrl af81d)❑ NO❑ DESCRIBE WORK l�q�, rtat � QIr� AG�L[YG}�� ANyLC C.AW-4 S UARE FOOTAGE:/propa.re-exlahrg) ��( 1���-•�5 uneter 30 I ST FLOOR_ 11494/. t 2ND FLOOR ° sq.ft. 3RD FLOOR sq.ft. BASEMENT — sq.ft. j DECK sq.ft. COVERED DECK i(/.sq.ft. STORAGE ^ sq.ft. OTHER sq.8. GARAGE r- sq.ft. Attached❑ Detached❑ CARPORT_ sq.ft. Attached❑ Detached❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* r� � MAKE MODEL ab(0 4 YEAR P Oc;t 0 L.ENGTH—kff—_ d WIDTH�8 BEDROOMS_ BATHS___SERIAL NUMBER i ENVIRONMENTAL HEALTH: SEWAGE/SEWERSOURCE: SEPTIC❑ SEWER/ NEW❑ EXISTING❑ PLUMBING IN STRUCTURE? YES&-, NO❑ Ifyes,attach completed Water Adequacy Form I PERIMETE.R/FOUNDATION DRAINS PROPOSED? YES❑ NO(_R- EXISTING SQ.FT. EXISTING BEDROOMS. PROPOSED BEDROOMS _ TOTAL BEDROOMS_ OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by i signature below.I declare that I am the owner and I further declare that I am entitled to rec:enm this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holler or parties of interest regarding this project. The ownerpr legal representative,represents that the information provided is accurate and grants employees at Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180 l days or if construction work is suspended for a period of 180 days. PROOF OF CONT TION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATIO OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIR (MASON COUNTY CODE 14.08.42) X ature of OWNER(Must be signed by the OWNER) Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT DEL .-2(•-w PLANNING DEPARTMENT FIRE MARSHAL PUBLIC HEALTH � T i i all ol EN L a JAI ■ 0 ■ �, ry man � ■�■m %ENE"`.i N. � � • • o . �iii� �i■. _�� � �L 11—q0650 i 4 /a,.5,s /)-=,c, l t V � •� A t `w ' •` OPT.TOWER DORMER WOWS. OPT.-W. PTSL - -r OPTWDW. Nfx -- W; 44 ; \ FAMILY ROOM UTILITY -.. a I s-s-xl z-.1 o- DOOR KITCHEN110 MASTER MBAT�IIR ® i--------� C` .:eBATN BATH o.r. i orrsLAxe DINING AREA , i-" #2 BEDROOM#2 O O xnm rnu -__ ' 9-3 X11 10 ; '� CEILING ,-- 9'-0'X13'-0• oJt , J O O WALK.IN '.- - - ' CLOSE PANTRY- ___- -_--_ i OPT.TOWER DORMER ; z6._9- .: OPT GLAMOURBATH OPT.TOWER DORMER LIVING kOOM ; MASTER BEDROOM RETREAT ; 1V-4-x13'-0, BEDROOM#4 War BEDROOM#3 1 3%f_X1 3%0' 9'B-X 1 3.0- ' o'-a x l z'-1 0 1 0'-z x l z a o , WALK OPT1 Y'' , i ENTRANCE CLOSET AI - 0►T.TOWFR DORMER WD WS. ALT.OPT.TOWER DORMER WDW / 1 •,•-�- MASTER BEDROOM - , OPT.MASTER BEDROOM W/CLOSE7 P � R E C D G W ESTO N SUPER VALUE NOV132019 MODEL 28684V 4Bedroom • 2Bath • 1 ,812Square Feet 615 W. Alder Street 4021 State Hwy 16 W I Bremerton, WA 98312 1-360.479.4663 Mon-Sat 9a-5p Sun 12p-5p www.futurehomesbremerton.com 4W FfirziEz- yX�5'SE�rs �inq s I VANiZv-V PresSu2C -WF-&T" n cF: ENE. �� H-f'r r � �r�55��►2��C2.FPrTi✓p ���M p T FA-C i A- �d iES�- To 6r:Rr✓i FI}5'i i X / CEDitK D���'i►1 -pre-:550rf Tit E►r-I EII Cc, C-OaC rt.t� i 1 __ - Sly€�, woof Cr�Er✓K IZ� IDa 36 - • Lu Ek re-,r> ie-G H zr IE i A-l L S�Tu1��i� R(iFTe� --, - - - 'RftFTF.P- ��-r -r�s h1'V1+N IZC6 y'!x, '� Pr tssuQ i3 1. v z�a cL�P lilt 101 bn cc LI COX- 7-EQC BEA-tv) ; re55t,t i ; job' dF Kt1\1 eG ,5,T,-INb i N -D E-r(t I L_ --,L4 3 PoRc 1+ Roos A- a u—k o u 5 E 11r1 FV 1U U FA-C T(4 1� D00 -- pb i W F Y-R-CIA Rod F C) -- F'RC E 5TFINI)IN CZ FbQcla LA N 0 E-01 k EA-z I+ t o e s iE- Q ----- ---- -- - �. 'T1 f Parcel#1��36-��'"��f%�� --- BLD . - Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is rnade for residential development,or redevelopment', with more than 2,000 square feet of impervious surface'. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area " All dimensions in feet Buildings (,_ r X T _ � - ► X Z� _ � Measurements for buildings are taken at the — perimeter of the farthest projections(example:X eaves/gutters) X = _Driveways------- X -- X = S� Length of drive begins at the right of way Parking Areas X 40 X = Any paved, gravel or packed area per definition above table X = Patios/Walks X = X = Any paved, gravel or packed area per definition above table X = Others _ _ X X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) If the Total Impervious Surface Area is LESS THAN 2000 Square Feet, please read,acknowledge and sign below. Based Upon the information you have provided a Stormwaler Site Plain /S NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor. 1 further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. Owner/Agent/Contractor(circle one)Date: If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read,acknowledge and sign the information provided on page 2 of 2. Pagel of 2 �r Name _ Parcel# 3 1,22 — 13LD#A01q -0 1'a1 Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14, Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirem Management in this jurisdiction. A complete copy of the ordinance can be found on the MV =D http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to"Title 14, Chapter 14.48 Stormwater Management". NOV 13 2019 Regulated activities shall be conducted only after Mason County Public Works approve�alMtkl eet (Mason County Code Title 14 Chapter 14.48 section 14.48.70). You will receive a copy off t e ub i ocument entitled "Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system (see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *'These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout' PLEASE 1NITIA1,BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) _ ['he relevant details from Managing Storm Drainage on Small Lois, The Small Parcel Stormwater Site Plan will be installed in th�rcntirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B)___An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail: P 0 Box 1850, Shelton WA 98584 Physical: 415 N 6th St, Shelton WA 98584 If this development has,or will have, a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other, parcel. You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail: P 0 Box 1666, Shelton WA 98584 Physical: 426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states, in part, that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that 1 am the owner,owner's legal representative,or the contractor.1 further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described p eFt f P inspection as may be required. X _ _ Owner gen ontractor(circle one)Date:_ l Page 2 of 2 .r- � 4 ��-- i L - ` 1 um- L19=1 WE 1= ■ v e , ■■■\►. 0 ■ ■E fME 0 ESO IN 9 Essig ESE 2 NONE C�� ■■� SW Plan we 11190111ki E 0 r NINE ■ IJR ■► OMINE IN■■ ■1 1/■■ I_ MEN, ■■■■1■■ /■olumnN■■■E Small Parcel Stormwater Site Plan Written Description Jan Oosterveld Mason County Tax Parcel # 12230-11-90090 The site is located just southwest of Allyn WA on a county road just off of State Highway 106 on a 1 + acre lot. The first approximately 200 feet of the lot is very level (from the county road heading towards the "back" of the property) and completely cleared and has been pasture land for over 25 years. The remaining back of the property remains forested with an upward slope and will not be in the building area at all. All vegetation on any of the sloped area will not be distrubed an will remain any unaffected by any site development. The property has no wetlands. Sherwood Creek is located over 400 south of the property. The creek is located on the opposite side of Sherwood Creek Road and on the south end of the properties on the south side of Sherwood Creek. Those properties that are across the street have homes constructed, then vegetation and then the creek that fronts the southern borders of those properties. The proposed development will have no effect on any neighboring properties, vegetation or Sherwood Creek. The Driveway will enter the property from a county road approx. 80'in length 12' wide and will be rocked immediately. The impervious surface of the drive is 960sgft, parking area of 600sgft, carport 600sgft, and the home of 1904 sq ft. The proposed total sqft of impervious is 4,064 which falls within the limits for Small Parcel Drainage Review. All stormwater flows will be dispersed through vegetation. To avoid saturating soils near the foundation of the house, roof runoff will be directed towards vegetated flow paths via downspout extensions. The same holds true for carport roof runoff. The property/home will be connected to the local public sewer system. The entire driveway is relatively flat. Therefore, runoff from this area can simply be allowed to sheet flow to the side towards existing vegetation. In order to prevent erosion and trap sediments within the project site, the following Best Management Practices (BMPs) will be used approximately as shown on the Erosion and Sediment Control ( ESC) plan: • Clearing limits will be easily distinguished by ribbons and stakes on the ground • The driveway will be constructed and graveled immediately. Dispersion trenches shall be placed according to flow control requirements. Areas accepting sheet flow from the driveway, parking area and building site ( that are not being left to native vegetation) will be mulched • .A rocked construction entrance placed at the driveway entrance. • Mulch will be spread over all cleared areas of the site when they are not being worked. Mulch will consist of air dried straw.