FIR2018-00045 - FIR Construction Plans (Blue Prints) - 6/15/2020
®S-20 A S-22® "A S-24® OS-21 S-23® FROM PREVIOUS SLC DEVICE S-25® A r(c'v \\4-D 61154``',./P 4-) ikr`\ 4.7K E.O.L.R. IFP 50 NAC # I 6' 12' 16' ATTIC INITIATION CIRCUIT PLAN aN13 200 SQ. FT. ; a conference room a' F. FIRST FLOOR INITIATION CIRCUIT PLAN ' 3200 SQ. 80'-0" conference room FIRST FLOOR INDICATION CIRCUIT PLAN QN/ 3 200 5Q. FT. a' a' 12' 16' 0 0) 0 0 7 PP 1# DEVICE / P/w/ X 7 G X PULLSTATION X HEAT DETECTOR X X X SMOKE DETECTOR X X X PHONE LINE 1 OR 2 LOSS X X LOW BATTERY X X FIRE ALARM SYSTEM MATRIX Obrata-- AES RADIO INSTALL IN PLACE OP DEDICATED PHONE LINES 1 sC?e):) ;f/4qr IFP 50 CIRCUIT BOARD r say 0 1 0 0 0 0 0 0 0 0 • • .=. ......... .... .T3'Sh�_ .i �.� �. I 10"(i coGtA VSA) TYPICAL CLASS B WIRING FOR DETECTORS TENS ONES IDP-ADDRESSABLE MODULE ADDRESS SETTINGS *NOTE: 0 CANNOT BE USED. TWO DEDICATED PHONE LINES DEDICATED 20 AMP I I OVAC CIRCUIT W/ LOCKOUT NAC 2 FACP - IFP 50 12V f12V ADDRESSABLE MODULE LIST MODULE DESCRIPTION # CONDITION NEAT DETECTOR ABOVE FACP 5-0 I ALARM SMOKE DETECTOR 5-02 ALARM SMOKE DETECTOR 5-03 ALARM SMOKE DETECTOR 5-04 ALARM SMOKE DETECTOR 5-05 ALARM SMOKE DETECTOR 5-06 ALARM SMOKE DETECTOR 5-07 ALARM HEAT DETECTOR 5-08 ALARM HEAT DETECTOR 5-09 ALARM HEAT DETECTOR 5- 1 0 ALARM SMOKE DETECTOR 5- I I ALARM SMOKE DETECTOR 5-1 2 ALARM SMOKE DETECTOR 5-1 3 ALARM SMOKE DETECTOR 5- 14 ALARM SMOKE DETECTOR 5-15 ALARM SMOKE DETECTOR 5-1 6 ALARM SMOKE DETECTOR 5- 17 ALARM SMOKE DETECTOR 5-1 8 ALARM SMOKE DETECTOR S- 19 ALARM ATTIC HEAT DETECTOR 5-20 ALARM ATTIC HEAT DETECTOR 5-2 1 ALARM ATTIC HEAT DETECTOR 5-22 ALARM ATTIC HEAT DETECTOR 5-23 ALARM ATTIC HEAT DETECTOR 5-24 ALARM ATTIC HEAT DETECTOR 5-25 ALARM TYPICAL WIRING DISTANCE GAUGE MAX. DISTANCE 22 AWG 1500 FT. 18 AWG 3900 FT. 16 AWG 6200 FT 14 AWG 10,000 FT UNUSED WIRE SCHEDULE SLC LOOP HORN CIRCUITS 43mI( 43m 43m54m43rr 4 NAC 1 \J \j/ \ SLC ©15 ®H10 ONE LINE RISER DIAGRAM IFP-50 15CD 15CD 15CD ©04 BACKUP BATTERIES A 2 CONDUCTORS # I G Fi 2 CONDUCTORS # 14 PI 43mK 454mA 121mA CD 15CD 15CD 15CD 15CD 1 �'L 5404eA.ethi fra 4.7K E.0..i RECEIVE OCT 15 2018 615 W. Alder St < < FIRE ALARM SYSTEM LEGEND > > SYMBOL DESCRIPTION MANUFACTURER MOUNTING HEIGHT PART # BACK BOX Q FIRE ALARM CONTROL PANEL FARENHYT TOP GO" AFF IFP-50 SELF FACP MANUAL PULL STATION WITH ADDRESS FARENHYT 48" AFF IDP-PULL-DA 4X4 STD/ I GANG P 00 ©00 SMOKE DETECTOR WITH ADDRESS FARENHYT CEILING MOUNTED IDP-PHOTO 4X4/ I GANG/4-0 I ©00 HEAT DETECTOR WITH ADDRESS FARENHYT CEILING MOUNTED IDP-NEAT-ROR 4X4/ I GANG/4-0 1 175CD WALL MOUNTED HORN STROBE WITH WATT/CANDELLA RATING SYSTEM SENSOR 80" 90" AFF TO BOTTOM OF BOX P2RL 4X4 STD/ I GANG 75CD WP WALL MOUNTED HORN STROBE WEATHER PROOF SYSTEM SENSOR 80"-90" AFF TO BOTTOM OF BOX P2RK SELF D 15CD WALL MOUNTED STROBE SYSTEM SENSOR 80" 90" AFF TO BOTTOM OF BOX SRL 4X4 STD/ I GANG 4-1 SCOPE OF WORK GENERAL NOTES AHJ Drafted By: Justin Leech Revisions: Date: PIONEER FIRE . SECURITY INC. P.O. BOX 597 EAST OLYMPIA WASHINGTON 98540 OFFICE (360) 49 I -814 I FAX (360) 49 I -6555 EMAIL:ELEFEIC# PONNE5963LC ET Electrical -LEI Date Created: I 0-4-20 18 Fire Alarm -Mason County Date Printed: I 0-4-20 I 8 PROTECTED BY Q File Name:Proglass-FA INSTALL FIRE ALARM SYSTEM TO MEET IFC, NFPA 72 AND LOCAL MUNICIPAL CODES I ALL WIRE LOCATED IN AIR PLENUMS SHALL BE IN METALLIC CONDUIT OR PLENUM RATED (FPLP) OR Btl I ER PIONEER FIRE SECURITY INC. WILL: Qu,(,"i C ,TB- rt Q,�,,� - c VA • 3w. i� 1.) INSTALL NEW FACP ` 2.) INSTALL WIRE TO NEW AUDIBLE DEVICES PER PLAN �z, 3.) INSTALL WIRE TO NEW INITIATING DEVICES PER PLAN ( ViBF� ,P�5 Cur b 1✓ �l C _ �� OuJ►t69 4.) PROVIDE PLAN SUBMITTAL SETS 4t, NOTih 5.) PROVIDE ELECTRICAL PERMIT G.) PROVIDE FINAL INSPECTION WITH AHJ Reviewed By: Bob Leech ® PIONEER FIRE & SECURITY 24HOURMONlTORlNG PROJECT INFORMATION SHEET /:// Prolass Office 3260 East Johns Franc Road Shelton, WA 95584 F A -