Loading...
HomeMy WebLinkAboutCOM2019-00049 Materials Testing and Consulting see TPN 419240000010 Alta Facitily - COM Inspections - 11/18/2019 MTCix Materials Testing & Consulting, Inc. Geotechnical Engineering&Consulting•Special Inspection•Materials Testing•Environmental Consulting Water Stain - 19S298 - Field Report: Other: Report #F220032 CLIENT Alta Forest Products DATE 11/18/2019 PROJECT LOCATION 780 West State Route 108 Shelton WA PERMIT#COM20-0049 Inspection Information: Inspection Date: Time Onsite: 8:00 Weather Mid 40's Cloudy 11/18/2019 am Conditions: Inspection Performed: 1 Other .. .... .w.aeeeme e _m _ ... __....�._. Comments: MTC Inspector,on site,as requested for pull-testing of the Stain Shack. After arriving on site I spoke with Alta rperesentatives&Vector Engineer who directed me to the testing location. The 3/4"anchor bolts were tested to a load of 3200 lbs. This was observed by everyone mentitoned above. See picture below for more information. __ To the best of MTC inspector's knowledge,the above-described work was performed in general accordance with project specifications and approved plans. Images: b t . 8 3 _.. � . UPLOADED: 11/19/2019 20:04:32 REPORTED BY:Ben Erskine REVIEWED BY:Michael Houser,Project Manager Corporate - 777 Chrysler Drive • Burlington, WA 98233 • Phone 360.755.1990 • Fax 360.755.1980 Regional Offices: Olympia Bellingham Silverdale Tukwila 360.534.9777 360.647.6111 360.698.6787 206.241.1974 Visit our website: www.mtc-inc.net Water Stain-19S298,1111812019,#F220032,Page 1 of 1 MTC Materials Testing. & Consulting, Inc. Geotechnical Engineering&Consulting•Special Inspection•Materials Testing•Environmental Consultinge+�n•�� Water Stain - 19S298 - Field Report: Structural Steel, Job site: Report #F216418 CLIENT Alta Forest Products DATE 10/04/2019 PROJECT LOCATION 780 West State Route 108 Shelton WA PERMIT #COM20-0049 Inspection Information: Inspection Date: Time Onsite: 8:00 Weather 10/04/2019 am Conditions: 50 s Partly Cloudy ._ ___. . Inspection Performed: Structural Steel Job site Report Profile: ®Any Deficiencies Noted 0 Needs Engineer's Approval Comments: Sheet(s): S-1 thru S-5 Location(s):Water Stain Shack Support Framing-No Gridlines Available Elevation(s):Platform-Varies Detail(s):Section Cuts,Details,&Elevations on Provided Sheets s MTC Inspector on site,as requested,for as-built inspection for Water Stain Shack Support Framing. Upon arrival I met with Alta Rep Dan&Ben with Vector Engineering. Current permit drawings were provided&the structure was walked with the individuals noted above. Building conditions varied from drawing&inspection requirements&Alta intends to put together updated As-Built drawings&submit to vector&the jurisdication for finalapproval. Items that varied from plan included: • Welders did not possess WABO certification nor was a Weld Procedure Specification available,all welds were previuosly welded. • Steel connections did not match the structural drawings&welds were used in lieu of high-strength bolts, shear tabs were excluded,beams coped,etc. • Anchor rods varied in embed depth but were stated to all be at 7"or greater.Epoxy used was common HY-200&a P.O.was given for the product but no special inspection performed. • Weld quality did not meet AWS Table 6.1 visual acceptance criteria.Weld size was deemed a consistent 1/8" Fillet at best but possesed undercut,underun,undersize,excessive convexity/cold-roll,&fit-up potentially in question per above. • Columns were not welded 1/4"fillet, all-around per detail B/S-5 due to fit-up,nor was a seam weld provided. MTC report is provided to cover basic Q.A.&Special Inspection requirements of the building and will provide report,and 'defer to Vector Engineering for review&acceptance. .—... __. __ _ . REPORTED BY:Ben Erskine REVIEWED BY:Michael Houser,Project Manager Corporate • 777 Chrysler Drive • Burlington, WA 98233 • Phone 360.755.1990 • Fax 360.755.1980 Regional Offices: Olympia Bellingham Silverdale Tukwila 360.534.9777 360.647.6111 360.698.6787 206.241.1974 Visit our website: www.mtc-inc.net Water Stain-19S298,1010412019,#F216418,Page 1 of 1 FN cr�.v r .. 6 1 N E E ! I N 6 \ l N E 2724 Black Lake Blvd. SW Suite 202 Tumwater WA 98512 Phone: 360-352-2477 Fax: 360-352-0179 Toll Free:844 204-5179 Technical Memorandum To: Dan Florek CC: File From: VEI Staff Date: 11/18/2019 Re: Final Project Acceptance for Water Stain Booth (Reviewed by Engineer of Record) Dan, This technical memorandum is pursuant to the meeting that took place on site October 4th, 2019. Parties present for this meeting were Materials Testing and Consulting (MTC) personnel, Dan Florek of Alta Forest Products (Alta FP), and Benton Cook of Vector Engineering (Engineer of Record). The purpose of the meeting was to address required special inspections for the project. MTC provided a field report regarding this meeting that deferred to Vector Engineering Incorporated (VEI) for final acceptance of the project due to differences between planned and as-built conditions. Specifically; the epoxy anchor rods, welding, and final project acceptance (see attached MTC Field Report #F216418). VEI staff returned for another on site meeting/inspection November 18th, 2019. The meeting's purpose was to address the issues noted in MTC's initial report, and to perform an in-situ load test on the post installed epoxy anchor rods. MTC personnel, along with Dan Florek and Brad Prihoda of Alta FP were present for this meeting as well. A post-installed epoxy anchor rod was tested by MTC personnel to a tensile force of 3,200 pounds, which is greater than the maximum factored design load (see attached MTC Field Report #F220032). VEI personnel performed a non-invasive visual inspection of the welds and deemed them acceptable, besides a few minor issues noted on the Welding Procedure Forms completed by VEI personnel during the inspection (see attached WPS Forms). The minor issues noted on the WPS forms were corrected by Alta FP personnel. VEI personnel then updated the original project drawings to reflect the project's as-built conditions (see attached as-built drawings). The field welding of this project was completed by Alta FP employees prior to inspection. In lieu of the standard special inspections for welding, the welds were inspected for general conformance by VEI staff, then reviewed by the engineer of record Benton Cook for final acceptance. Special inspections for this project are in general compliance with the Mason County Special Inspections &Testing Agreement (see attached copy), except the field welding and post installed anchorage as previously noted. The Table of Special Inspections in the approved plan set complies with the Mason County Special Inspections &Testing Agreement as well. Welding was done in general accord with the WPS provided by VEI and approved by the engineer of record. Inspection was visual only. The inspected work appeared adequate after execution. It appears the work substantially conforms with the intent of the design and that the building is suitable for occupancy. x:\2018 jobs\a1ta02(spray room)\communication\tech memos\final acceptance of project.docx Please feel free to call or email if you care to discuss. Sincerely, VEI Staff Reviewed By: Benton S. Cook (Engineer of Record) 17984 w ICISTL-ti����y1� S��NAi 12.05.19 X:\2018 Jobs\AIta02(Spray Room)\Communication\Tech Memos\Final Acceptance of Project.docx Page 2 of 2