HomeMy WebLinkAboutBLD2020-00759 - BLD Plot / Site Plans - 5/11/202130x30x12 PAD W/
(3) #4 EACH WAY
18x18x12 PAD W/
(2) #4 EACH WAY
6x6 PT POST W/ ABU66 B
MITER J❑ISTS W/ LCE4
42x42x12 PAD W/
(4) #4 EACH WAY
15'
6x6 PT POST W/ ABU66 BASE
x12" TREATED GLULAM
FLUSH W/ HUC610 HANGER
(3) 2x12
6x6 PT POST W/ ABU66 BASE
5Y"x12" TREATED GLULAM
FLUSH W/ HUC610 HANGER
24x24x10 PAD W/
(2) #4 EACH WAY
(TYP IN CRAWL)
NOTE: PLACE VENT WITHIN 3' OF
FOUNDATION CORNER UNLESS CONFLICTING
WITH STRUCTURE
IRC R408.2
FOUNDATION VENTILATION:
6"x16" SCREENED FOUNDATION
VENTS = .67 SQ. FT.
1330/150 = 8.87 SQ. FT. VENTILATION
-OR-- 13 VENTS (13 VENTS SHOWN)
1/4'=1'-0'
5/-6"
rT
L_J
STHD14
STHD14
84x42x12 PAD W/
(4) #4 EACH WAY
30x30x12 PAD W/
(3) #4 EACH WAY
/6x6 PT POST W/
ABU66 BASE
53 x12" TREATED GLULAM
FLUSH W/ HUC610 HANGER
PT J❑ISTS @ 16" O.C.
2x12 PT LEI3GEP W
LED5ERLOK @ 7" 0
L_J
CRAWLSPACE
rz-6 MIL BLACK PLASTIC
VAPOR BARRIER
4'-6"
r
L L _ J
4x8 BEAM (TYP)
19'
ALL PONY WALLS TO HAVE SAME SHEAR WALL NAILING AS WALL ABOVE
30' VIDE CRAWL ACCESS
VENT (TYP)
2x4 PONY WALL
(AS NEEDED)
%"r A,B, @ 48'o/c
2'x6' PT PLATE
FINISH GRADE
NOTES!
1, DETAIL 1 IS APPROVED FOR
WALLS WITH EQUAL BACKFILL OR
LESS THAN 48' OF UNBALANCED
BACKFILL
2. USE 24' WIDE F❑❑TING FOR
WALLS GREATER THAN 4' BUT
LESS THAN 6'
3, USE 30' WIDE F❑❑TING FOR
WALLS GREATER THAN 6' BUT
LESS THAN 8'.
4, 24" AND 30' F❑❑TINGS SHALL
HAVE (3) #4 C❑NTINU❑US
#4 H❑RIZ, @ 18'o/c
#4 VERT, @ 18'o/c
(ALT HOOK)
- ,,2)#4 IN FTG,
FINISH GRADE
1-TYDICAL ECUNDATION
74'=1'-0"
132' MAX
2'xi0' PT LEDGER
WEDGE @ 8"o/c (STAGGERED)
FLOOR J❑ISTS
18' MIN,
2-3ASEME
3'4'=1'-0'
#5 VERT, @ 8'o/c
#4 H❑RIZ, @ 18"o/c
- 48' MAX BACKFILL
PRI❑R TO COMPLETION
OF FLOOR DIAPHRAGM
#5 48'L @ 8'o/c
12'
#4 @ 8'o/c
#4 @ 16'o/c
4' PERF PIPE IN DRAIN ROCK
WRAPPED IN FILTER FABRIC
�1T RETAI\I\G WALL
SCAI...E: AS SHOWN
DATE: Oct 2020
DRAWING NUMBER.
i7S
St£TI
NaOwfN ON1md23a
OZOZ 110 :3.Lda
NMOHS SV : '-1\OS'
2453 Bethel Avenue, P.O. Box 637, Port Orchard, WA 98366
(360) 895-2350 or (360) 876-2284
td
CD
ono
N
00
0
Q3.. Ld3JJd
Q3AO2Iddd
n
n
m
N
r
iJ
Q3['.JIS3Q
tJ
b
-4
N-3
�(lNnbd.3q SNI
��� A/003 Nos p,
WO
c-1.344.3,473(L
OS ��ds
7d
/2.
S3QOJ 31VIS NOIWNIHSVM
IN3NN(1JTIV133W ism
co
X
(d),I) 'J'❑ 119T 7 SISI❑f OTX2—
'3'0
MVTd ONII"VIId ?IOOZd MIVIN
-
I o
X
o
(HSi111_;)
TX.b
XXXX
KXX>O(
,,X,X
}-XXX',xxxvcxoXKXXX,X
AXXXXX
, Q
2Q
`I�yM
�NI21d3g
1.
L
ri
HA
/(
N91 8 SISI❑f Id 21X2
'3'0
/M
NL
<J3❑G31
7
)101Z13❑Q311
Id
2tix2
�
at
d1n1D
„ZT
'<„lib
CtTXt
T11Q
i1
.:r
wv-n-ip G31V3ell NZTX„2/jS
d'd3 933V
/M 1S❑d id 9x9 dVJ 933V
/M IS❑d Id 9x9
_
_
_
_
`.
NV1ln19 QIl'd3Jl „2TX„2!S Vlb'1n1D QEldell „2IX„2AS /
dVJ 93V
/M IS❑d Id 9X9
dVJ 933V /M IS❑d id 9x9
CHANGES
SUBMIT CHANGES FOR APPROVAL
PRIOR TO PERFORMING WORK
"RD 2626 --E:41f5'
695 7
Oal_
-De Gt. Rev).sict
?1fCe( t zzo62—&-o- oso (z_
MUST MEET ALL CURRENT
WASHINGTON STATE CODES
REVISED
J.EC_-DATE (
ST COMPLY WITH
PERMIT CONDITIONS
)vf:D
•,:,N1 BUILDING INSPECTOR
S SUBJECT TO APPROVAL
DATE
Dour attached to approved plans:
Site Plan
Fien review checklist: Pages
EngiCicefing: Y N Lateral Vertical
p9ges
E.12.4A4 CitteS ( F-
r(A-k_Cs z_n
THESE PLANS MUST BE
ON THE JOB SITE
FOR INSPECTION