FOOTING NOTE
PERIYIATIErfr FOUNDATION sysTEm
INSTALLATION INSTR.UCTIION'S
1. INSTALL FOUNDATIONWORKS FOOTINGS AND
SUPPORT COLUMNS TO SPACING, PER THIS
SHEET.
? FOUNDATION FOR CHASSIS BEAM SUPPORT
SHALL BE LOCATED AND SIZED FOR lab
LOADS, AS SHOWN BY MANUFACTURED HOME
INSTALLATION INSTRUCTIONS.
3 LEVEL SOIL AND PLACE REINFORCED PRE-
CAST CONCRETE FOOTING BELOW MANU-
FACTURED HOME, AS PER LAYOUT ON THIS
SHEET SAND OR 3/z" MINUS MAY BE USED TO
FILL IN VOIDS UNDER FOOTINGS, WHERE
GROUND IS UNEVEN.
4. SINGLE AND DOUBLE UNITS:
PREFERRED FOOTING ORIENTATION. WHERE
EVER POSSIBLE IS THAT THE LONG
DIMENSIONS OF THE FOOTINGS BE IN THE
TRANSVERSE DIRECTION. UP TO ONE-HALF OF
THE FOOTINGS MAY BE ROTATED SO THAT
THE LONG DIMENSIONS OF THE FOOTINGS ARE
PARALLEL TO THE MEIN FRAME, DUE TO SITE
OR SEL UP CONDITIONS_
a. SEl SUPPORT COLUMN TO ITS LOWEST
SETTING, PLACE IT ON CONCRETE FOOTING
AND ATTACH IT TO FOOTING WITH'/," BOLTS.
6. RAISE TOP SECTION OF SUPPORT COLUMN
UNTIL IT TOUCHES BOTTOM CHAS f: LS BEAM,
THEN LOWER 'UNTIL HOT RS. LINE UP FOR
ADJUSTING BOLT INSTALL s/s" BOLT
THROUGH SUPPORT COLUMN THEN TIGHTEN.
_7. TURN LARGE NUT UNDER HEAD UNTIL PLATE
CONTACTS BEAM INSTALL 2 CLAMP PLATES
AND TIGHTEN FIRMLY_
8. FOR FINAL FINE ADJUSTMENT AND LOAD
TRANSFER TO FOOTING AND SUPPORT
COLUMNS, TURN LARGE NUT UNDER HEAD
e 5' m¢nun
s 22' maximum
T receded for Exposure C only
FOOTINGS AWE 28" SQ. INCHES
CNERSCZETO ALLOW FOR MAGNUM PIER DIMENSIONS ABCDE
CHIPPING. INCLUDE 4" FOUNDATION FOOTINGS
PIER HEIGHTS THAT EXCEED 35'
MUST BE CROSS AND
LONGITUDINALLY BRACED
SEE DRAWING OF MAGNUM
BRACING AND CLAMPING
•
► f'
MAGNUM PIER
SIZES
A. 13" TO 161/"
B. 16" TO 23"
C. 191/2"TO31"
D. 24" TO 3.51'
E. REFER TO LOWER.
RIGHT HAND CORNER
I
BEAM SIZE NOTES
SPACING SHOWN ON THIS PLAN ARE FOR HOMES
WITH 10" AND 1T' BEAMS.
ANY 6"- 91' CHASSIS BEAM IS NOT TO CANTILEVER
MORE THAN 8' ON EACH END OF UNIT. SPACING
OF FOUNDAT1oNW ORKS FOOTINGS AND SUPPORT
COLUMNS CANNOT EXCEED 16'0".
HOME LENGrMS NO
DOUBLE -WIDE:
WINDS 80 MPH EXPOSURE C
- UP TO 44': 8 FOOTINGS & COLUMNS
45' - 66': 12 FOOTINGS & COLUMNS
66' - 72' (MAX): 16 FOOTINGS & COLUMNS
N.
STNGI F.-WIDE-
RTNDS 80 MPH EXPOSURE C
UP TO 44': 4 FOOTINGS & COLUMNS
45' - 66': 6 FOOTINGS & COLUMNS
66' - 72' (MAX): 8 FOOTINGS & COLUMNS
'11E DOWN NOTES
SINGLE -WIDE HOMES SHALL HAVE AN AUGER
AND STRAP TYPE 11>s•DOWN, PLACED AS SHOWN
ON SINGLE -WIDE PLAN
Jib —DOWNS SHALL BE AN AUGER AND STRAP -
TYPE RA ihU FOR A MINIMUM OF 4250 LB
PULLOUT_
DOUBT P--WIDE HOMES IN 80 MPH WIND AREAS
WITH EXPOSURE C, THAT WEIGH MORE THAN
50600 LBS., OR ARE CONSIRUC TED WITH
COMP OSMON ROOFING AND SHEETROCX.
CLADDED WALLS, DO NOT NEED THE FOUR TIE -
DOWNS SHOWN ON 1 HE PLAN.
SINGLE -WIDE HOMES IN 80 MPH WIND AREAS
WITH EXPOSURE B, NEED 11E—DOWNS AT EACH
CORNER ONLY.
AUGER lit -DOWNS SHALL BE LISTED A]4D
INSTALLED IN ACCORDANCE WIT73 THE AUGER
lIE—DOWN MANUFACTURER'S INSTALLATION
INSTRUCT"'ONS_
AUGER 1 1 r,-DOWN LISTING AND INSTALLATION
INSTRUCTIONS SHALL BE SUBMITTED WITH THIS
PLAN, AND PERMIT APPLICATION IF INSTALLA-
TION OF AUGER litDOWNS ARE REQUIRED (SEE
TIE -DOWN NOTES) OF THIS PLAN_
1
i
1
r`xrxw
? NG2E 6" LON
•
•
•
❑
�r 4--
n■ n tui
`` .. ��. N
` i Min f 1l11
ENGINEERED FOUNT //ATION SYSTEM
FOUNDATiONRV
DRAWING N 'i MR ' INC_
MODEL N"FJ th [BER lYIFS--22F
a2. MPS -Gip
'll
7EDITS WIx?"
U I
FIELD
DRILL
i
GENERAL NOTES
DESIGN LOADS:
ROOF LOAD - 30 PSF
FLOOR LOAD -40 PSF
DOUBLE -WIDE:
WIND 80 MPH EXPOSURE C
SFTSIviiC ZONE 4
SINGI F,-WIDE:
WIND 80 MPH EXPOSURE C
SEISMIC ZONE 4
WITH 4 111-DOWNS THE DESIGN LOADS SHALL BE
CONSISTENT WITH ROOF LIVE LOAD, WIND LOAD
AND SEISMIC ZONE AS ESTABJ !SHED FOR
PERMANENT BUILDINGS WITHIN A SPECIFIC
LO CAL AREA
THIS FOUNDATION IS DESIGNED TO BE
CONSTRUCTED ON SITES WITHOUT EXISTING
SOIL PROBLEMS. FOOTINGS ARE DESIGNED FOR
1000 PSF SOIL AND SHALL BE COMPAilBLE WITH
LOCAL SOIL CONDITIONS.
IN AREAS WHERE SETTLEMENT OR I XPAN-SIVE
SOIT S OCCUR, MANUFACTURED HOMES SHOULD
BE RE -LEVELED WHEN IT MAY ADVERSELY
AFFECT THE MANUFACTURED HOME
FOR TRIPLE -WIDE AND WIDER HOMES, USE THE
LAYOUT FOR EACH SECTION, AS SHOWN FOR
EACH SECTION OF A DOUBLE -WIDE HOME OF THE
SAME LENGTH
INSTA lATIONNEARASC LADING ANDDESCEND-
ING SLOPES SHALL BE IN ACCORDANCE WITH
UBC SECTIONS 180652 AND 180653, UNLESS A
SITE' -.SPECIFIC GEOTECEINICAL REPORT RECOM-
MENDS OTHERWISE
r
COMPACmD GRANULAR FILL GREATER THAN 12"
IN DEF13i SHALL HAVE A COMPACTION TEST
PERFORMED TO ENSURE ADEQUATE COMPAC-
TION.
• 'C
1'•
SPECIFICATIONS
WELD ACCORDING TO A.W.S. 1.1-98
SPECIFICATIONS
A.W.S. SOLID WIRE ER70S-6
PLATES A.S_T_M. A36
PIPE SCHEDULE 40
SUPPORT COLUMN BOLTS S_A_E_
GRADE 5
FOOTINGS 3000 PSI 8 28 DAYS LIGHT-
WEIGHT REINFORCED CONCRETE
FOUNDATIONWORKS SUPPORT ASSSEMB13ES
SHALL BE COATED WITH FOREST TECHNICAL
COATINGS CHASSIS PAINT 88-E--203 OR
EQUIVALENT.
TESTING
TESTS PERFORMED BY: PSI LAB
41689 36125-1 •
MAX VERTICAL TEST LOAD • 40000 LBS.
RATED VERTICAL CAPACITY: 133331_13S
RAZED LATERAL CAPACITY AT 25" MAX
Hl?1GHT IS 4733 LBS
RAffl) LATERAL CAPACITY AT 24" - 35"
MAX HEIGHT IS 3800 LBS
CERTIFICATION: •
THIS IS TO CERTIFY THAT 11fb SUBJECT SYSTEM
IS CAPABLE OF WITHSTANDING ALL RA11:
DESIGN LOADS THIS CERTIFICATION IS PREDI-
CAih1) UPON THE PROPER INSTALLATION AND
aft- SUPPORT COLUMNS.
TIGHTENING OF
SPECIAL CONDITIONS
PLEASE CONTACT FOUNDATIONW OAKS, INC. FOR
INFORMATION ON ANY OF THE FOLLOWING
CONDITIONS:
SNOW LOAD OVER 30 PSF
FLOOD PLAIN LOCATION
\t \t1llN.\\1\
\\ \ •l paSTINCI "rREAM -
�\ ,
PIER HEIGHTS 35"-TO 52" MUST BB
CROSS AND LONGITUDINALLY BRACED