HomeMy WebLinkAboutBLD2018-01319 Demo - BLD Permit / Conditions - 5/1/2019 Mason County
Mason County - Division of Community Development
615 W. Alder St. Bldg. 8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
B DD2018-01319 GARAGE/ STORAGE
PROJECT DESCRIPTION: DEMO EXISTING SHED/CABANA AND ISSUED: 05/01/2019
REPLACE WITH NEW CABANA 2 STORY WITH 1/2 BATH
SITE ADDRESS: 7611 E STATE ROUTE 106 UNION EXPIRES: 10/28/2019
PARCEL: 322334400010
APPLICANT: GREG CARROUGHER OWNER: GREG CARROUGHER
123 XXX 588 BELL STREET #2102 SOUTH
XX, XX 00000 SEATTLE,WA 98121
FEES: Paid Due
Plumbing Base Fee $24.70 $0.00
Change in Tenant- Minor EH $110.00 $0.00
Plan Review
Plan Check Fee $136.01 $0.00
Plumbing Fees $26.10 $0.00
Mechanical Base Fee $28.50 $0.00
Mechanical Fees $9.00 $0.00
Building Permit Fee $209.25 $0.00
State Fee-Residential $6.50 $0.00
Planning Review Fee $240.00 $0.00
Totals : $790.06 $0.00
REQUIRED INSPECTIONS
Setback Inspection Rough- Plumbing Inspection
Footing Inspection Mechanical Inspection
Foundation Wall-Pre-Pour Inspection Insulation Inspection
Shearwall Inspection BLD-Final Inspection
Framing Inspection
Printed by:Nicole Norris on:05/01/2019 02:58 PM
Page 1 of 5
3
\ Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg. 8
® Shelton, WA 98584
——" 360-427-9670 ext 352
www.co.mason.wa.us
GARAGE/ STORAGE BLD2018-01319
CONDITIONS
• The foundation/footing must be placed on undisturbed, firm-native soil.
• The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more
than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards
for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to
another fire apparatus access road which connects to a county maintained public road.
* WIND LOADS- Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic
wind speed for Mason County is 85 MPH.
* All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor
increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way.
" A permanent certificate, completed by the builder or registered design professional, shall be posted on a wall in the space
where the furnace is located, a utility room, or an approved location inside the building. When located on the elctrical panel,
the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect labek, or toher reqyired
Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls,foundation (slab,
basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the
solar heat gain coefficient(SHGC)of fenestration. Where there is more than one value for each component, the certificate
shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service
water heating equipment, duct leakage rates including test conditions as specified in WSEC Section R401.3 & R402.4.1.2,
and air leakage results if a blower door test was conducted.
Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air
changes per hour when tested with a blower door in accordanve with IECC/.WSEC Section R402.4.1.2.
The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution
panel. Air leakage testing is not required for additions less than 500 square feet. Reference IECC/WSEC R402.4.1.2.
Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2015 Certificate" and are
available in '/4 or'/2 sheets. The Mason County Permit Center will also have some available.
Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly
corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of
pressure treated material.
" Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer
specifications and in accordance with IRC Section R315.
Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level
of the dwelling.
EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of
fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or
created.
All building permits shall have a final inspection performed and approved by Mason County Building Department prior to
permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property
records on file with Mason County as being non-compliant with Mason County ordinances and building regulations.
Printed by:Nicole Norris on:05/01/2019 02:58 PM
Page 2 of 5
Mason County
Mason County - Division of Community Development
615 W. Alder St. Bldg. 8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
GARAGE/ STORAGE BLD2018-01319
" REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable
provisions of the current code and the manufacturer's installation instructions.
A drip edge shall be provided at eaves and gables of shingle roofs.
* Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC
R403, applicable sections of the IRC, and IMC.
Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the
purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including
infiltration and ventilation. Design calculations shall be available for inspection during inspection.
Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct
systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other
approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be
marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used
with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-
sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings
shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B
and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm)
and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint.
Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation
instructions.
Duct tape is NOT permitted as a sealant on any ducts.When ducts are located in unheated spaces the ducts hall be
insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit
documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building
Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website
titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not
required if the air handler and all ducts are located within the heated space.
* All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building
Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration.
Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No
more than one extension may be granted.
* A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit
application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the
responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that
Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement
of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater
Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel
Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the
development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other,
parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final
inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater
management system have been installed as approved on the stormwater site plan.
Printed by:Nicole Norris on:05/01/2019 02:58 PM
Page 3 of 5
Mason County
Mason County - Division of Community Development
615 W. Alder St. Bldg. 8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
GARAGE/ STORAGE BLD2018-01319
Adopted IECC/Washington State Energy Code Compliance has been approved as follows:
Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window(Max U-
Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less,Wall insulation R-21, Floor insulation
R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10.
* All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or r,
any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction.
* CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING
DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All
construction must be in conformance with the international codes as amended and adopted by Mason County. Any
corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting
additional inspections.
* By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your
"Approved Site Plan"to ensure these structures meet the setback conditions listed.
* The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility
of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked
"APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is
responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of approved documents will result in failure of required building inspections.
* Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site
plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed.
* Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and
MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either
private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an
existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance
and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting
from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any
construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that
office to review future planned work which may affect your project.
* The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the
approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule,
minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being
performed or approvals granted.
* Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a
permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor
& Industries (L&I).
For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415-
4000.
* A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance
with IECC/WSEC Section R404.1.
* A Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more
information contact Public Works, at (360)427-9670, ext. 450 or 100 W Public Works Dr. Shelton. The building permit will
not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and
approved.
Printed by:Nicole Norris on:05/01/2019 02:58 PM
Page 4 of 5
Mason County
Mason County - Division of Community Development
\ 615 W. Alder St. Bldg. 8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
GARAGE/ STORAGE BLD2018-01319
* Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries,
Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an
unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either
the homeowner, agent for the owner or a registered contractor according to WA state law.
" On-site Septic System Operation and maintenance approval required prior to temporary/final occupancy of the residence.
• On-site Septic System operation and maintenance required prior to temporary/final occupancy of the residence.
I hereby certify that I have read and examined this application and know the same to be true and correct.
All provisions of Laws and Ordinances governing this type of work will be complied with whether
specified herein or not. The granting of a permit does not presume to give authority to violate or cancel
the provision of an other state/local law regulating construction or the performance of construction.
Issued By:
C C✓t i�- �r1 ti S 3 ,xi ( J
Contractor or Authorized Agent: � Date:
Printed by:Nicole Norris on:05/01/2019 02:58 PM
Page 5 of 5
r
RI Ul T T fn n n O O
O O D m
1 co c o a Z Z z ;u 'I
a y 3 7 0 N n n
_ m m _0 O O
M m
�1 ° ° o°
1�t �' CD 3 3 O m N
\ 1 o Z Z m w
G) ca
CD
m D o co
b � o 0
0 o
_ c co
m
S
n � � D
r� a rn
4 m v v
CD Z v v X ;o
N y mmm oc-
t CA 0 0
CD
cri v D 27)
00
00 m v cp rn
W to v t, ^
r- X m o N oo cn
0
cn �1.OD l! O
7 3
�• CDC n m cc m � D m °� c �
0 0 = 3 j n) Dp m
3 3 7 a z cn z m
l� c D x D
� � D v
3 = o z m co
� m m
n N W o
n rn
n coD z
p m = D O
D z
z
_ O O 0 D
to Z z m 00
m m -u cn
t+ N
N D
3 m
w
N
w z
w m
,►° c MASON COUNTY Permit No,,, l d ao i a- (c(
DEPARTMENT OF COMMUNITY DEVELOPMENT
BUILDING•PLANNING•FIRE MARSHAL (360)427-9670 Shelton ext.352
http•/www.ro.mason.wa,ustoommunity dev/ (360)275-4467 Belfair ext.352
' 426 W Cedar Street,Shelton WA 98584 (360)482-5269 E�ffdt IV E D
" LDINGUILDING PERMIT APPLICATION p
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: M)y Div
NAME: Greg&Gretchen Carrougher NAME: 615 W_ Aldell Street
MAILING ADDRESS: See Bell SL#2102 South MAILING ADDRESS:
CITY:Seattle STATE: wA 'LIP:98121 CITY: STATE: "LIP:
PHONE: CELL:(263)514-9133 PHONE: CELL:
EMAIL: EMAIL:
L&I REG# EXP.
CONTACT: OWNER a CONTRACTOR❑ BELOW❑
NAME: MAILING ADDRESS:
CITY: STATE: ZIP: PHONE: CELL:
EMAIL:
PARCEL INFORMATION:
PARCEL NUMBER(12 DIGIT NUMBER) 32233-44-00010 FIRE DISTRICT
LEGAL DESCRUMON(ABBRFVIATED): TR 1 OF E1/4 OF LOT 1&TL S 6/64 S 40147-48
SITE ADDRESS 7611 E.STATE ROUTE 106 CITY UNION,WA 98592
DIRECTIONS TO SITE ADDRESS Take Hwy 101 N.R on E Purdy Cutoff Rd. R on E State Route 106
IS PROPERTY WITHIN 200 FT:
SALTWATER R LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑
DOES PROPERTY HAVE SLOPE(S)WITHIN 3W FT OF THE PROJECT-GREATER THAN 14% YES❑ NO 1s
TYPE OF JOB: NEW p ADDITION ❑ ALTERATION❑ REPAIR❑ OTHER ❑
USE OF STRUCTURE(RESIDENCE,GARAGE ETC.) Detached cabana replaces existing.
IS USE: PRIMARY❑ SEASONAL @ NUMBER OF BEDROOMS N/A NUMBER OF BATHROOMS 1
DESCRIBE WORK Damn existina detachad shed h„ild new detachad rnhana
SOUARE FOOTAGE:
1ST FLOOR 171 sq.ft. 2ND FLOOR 69 sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft.
DECK sq.ft. COVERED DECK sq.ft.STORAGE sq,ft. OTHER sq.ft.
GARAGE sq.ft. ATTACHED❑ DETACHED❑ CARPORT sq.ft. ATTACHED❑ DETACHED❑
MANUF D HOI 01:UMATI0 -4 COPIES orImE FLOOR PLAWREQUIRED
Mo MO YEAR ENGT
iDTH �,,.__ BEDROOMS BATHS SERIAL NUMB
OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner or owner's legal representative.I further
declare that I am entitled to receive this permit and to do the work as proposed.1 have obtained permission from all the
necessary parties,including any easement holder or parties of interest regarding this project.The owner or legal
representative,represents that the information provided is accurate and grants employees of Mason County access to
the above described property and structure(s)for review and inspection.This permit/application becomes null&void if
work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of
180 days.
PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT
APPLICATION OF 180 DAYS WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON COUNTY CODE 14.08.42)
x 11/9/18
Signature of OWNEIT Date
DEPARTMENTAL REVIEW APPROVE DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT Vt� {71 q*
PLANNING DEPARTMENT
FIRE MARSHAL
FEE'S TOTAL VALUATION:
BUILDING PERMIT FEE FIRE ACCESS AND GRADE
PLAN REVIEW GEO-TECH REVIEW
PLUMBING&BASE FEE STORMWATER REVIEW
MECHANICAL&BASE FEE TOTAL FEES
WOOD/GAS/PELLET STOVE VIOLATION INVESTIGATION FEE
PLANNING REVIEW FEE VIOLATION FEE
co
MASON COUNTY PERMIT NO.
DEPARTMENT OF COMMUNITY DEVELOPMENT
BUILDING• PLANNING• FIRE MARSHAL
WWW.CO.MASON.WA.US (360)427-9670 Shelton 352'^"'
Mason County Bldg. III, 426 We eEia)E tr�et DN %X60)
60)275-4467 Belfair e 3S2-� •-- v D
PO Box 279, Shelton, WA 9858 �JJ LL 482-5269 Elma ext.35 V 1 �O�Q
k 1 V
PLUMBING & MECHANICAL PERMIT APPLICATION15 W. Alder Street
OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME: Greg&Gretchen Carrougher NAME:
MAILING ADDRESS: 588 Ben St.#2102 South MAILING ADDRESS:
CITY: Seattle STATE: WA ZIP: 98121 CITY: STATE: ZIP:
PHONE: CELL: (253)514-9133 PHONE: CELL:
EMAIL: EMAIL :
L&I REG# EXP.
PARCEL INFORMATION:
PARCEL NUMBER(12 DIGIT NUMBER): 32233-44-00010
LEGAL DESCRIPTION(ABBREVIATED):TR 1 OF E1/4 OF LOT 1 &TL S 6/64 S 40/4748
SITE ADDRESS: 7611 E.STATE ROUTE 106 CITY: UNION,WA 98592
DIRECTIONS TO SITE ADDRESS:Take Hwy 101 N,R on E Purdy Cutoff Rd.,R on E State Route 106
TYPE OF JOB
NEW X ADD ALT REPAIR OTHER USE OF BUILDING
LOCATION OF FIXTURES/UNITS—lsT FLOOR x 2ND FLOOR BASEMENT GARAGE OTHER
PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS
Type of Fixture No.of Fixtures Fees Fuel Type:Electric LPG Natural Gas Heat Pump_
Toilets 1 Type of Unit No.of Units Fees
Bathroom Sink 1 Furnace
Bath Tubs Heatpump
Showers J Spot Vent Fan 1
Water Heater o Propane Tank
Clothes Washer Gas Outlets
Kitchen Sinks Wood/Gas/Pellet Stove
Dishwasher Kitchen Exhaust Hood
Hosebibs Dryer Vent
Other Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or contractor.I further declare
that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including
any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is
accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This
permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is
suspended for a period of 180 days.PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INACTIVITY OF THIS
PERMIT APPLICATION F 180 D S WILL ALIDATE THE APPLICATION.
X 11/9/18
gnattuure of A/ppli/c Date
X 1� OI (i1�1�?C U I/�i��/1� Ownerk6wners Re resentative Contractor
Print Name one)
D.EPARTMENTAL.REVIEW , APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT a=C—
PLANNING DEPARTMENT
FIRE MARSHAL
CANAL CC�
- �KDUgE
1. 5TD"�'f
►*iO'N
,
r
1
r
i
i
E?CC�, SHED
_ kr l�►/-�-- I Y
N, O&7X
1 i
i r
I
i
I
1
i
18 X 24 MINTED ON NO.1000M CLEMMIINT•
pRovE® RECEIVED
MASON CoUNT REDO O eE ON SITE NOV 1 12018
SITE PLAN REUB3615 W.
CHANGES SUBJECT TO A �VA
Alder Street
^, Date
13y
Hood Canal
PLANNING
EXISTING DOCK 15' SHORELINE 5ET5ACK LINE PLANNING:
ALL SETBACKS ARE MEASURED
CONCRETE BULKHEAD BELOW MHW) FROM THE FURTHEST
PRQJECTION OF THE BUILDING
EXIST. DECK
10 (LOVITT)
115.15 (CALC) 20' SIDE SETBACK LINE
EXIST. HOUSE ROOFLINE existing L
CONCRETE BULKHEAD (MHW) Resider-ice
EXIST. DECK TO REMAIN NO WORK
BEACH
10' FRONT'SETBACK LINE _d- EX-I$I' N 83_29_38_E — —
CNN DRIVEWAY
, EXISTING STEP —
`1`X15TING SHED 4 DN_� TO REMAIN
ROOFLINE TO BE REMOVED 1 L EX15TING-PAkTtO
WORK TO BE WITHIN — — TO REMAi� E�GE OF HIGHWAY PAVIIN
EXIST. ROOF O.H.
NEW CABANA — \
240 ._TOTAL
- —nl 5F. MAIN FLOOR
69 SF. LOFT � s
EXISTING ■ �` o' \
SLOPE TO REMAIN
I I SR 106 �..�"'� `n \ FOG LINE
EXIST. FENCE 4 PLANTER ,� I '?
TO REMAIN - MODIFY
AS REQ'D. �W ^
<o
N I I I 0 __ _
EDGE OF HIGHWAY PAVIt`
N = N _
-
� 832938 E
100' FISH 4 WILDLIFE 5UFFER/5ET5ACK LINE
_ � I
11'1
Exi i
n0eA-
EXISTING WELL
NOTE. W5DOT 4 PUD I HAVE PROVIDED WRITTEN PRE-APPROVAL FOR CABANA REVISIONS
- COPIES PROVIDED WITH PERMIT APPLICATION
Name Greg & Gretchen Carrougher parcel# 32233-44-00010 BLD# /M161bdK�� ire*r%
L.LJ
Mason County NOV 1 12018
BU D NGepartment of Community Development
Sm L 2pl Vormwater Management APPlication/Workshe g6v �leet
Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is
made for residential development,or redevelopment', with more than 2,000 square feet of impervious surface2.
'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development
including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not
part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment.
2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas,
concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the
natural infiltration of stormwater. Open,uncovered retention/detention facilities shall not be considered as impervious surfaces.
To Calculate Impervious Surfaces Please Complete This Table
Surface Type Length X Width = Area ` All dimensions in feet
Buildings X
X = Measurements for buildings are taken at the
X _ perimeter of the farthest projections (example:
eaves/gutters)
X =
Driveways X = Existing
X = Length of drive begins at the right of way
X =
Parking Areas X =
X _ Any paved, gravel or packed area per definition
above table
X =
Patios/Walks X = Existing
X _ Any paved, gravel or packed area per definition
above table
X =
Others X =
X = If the total impervious area of the proposed site
X = development is greater than 2000 square feet a
Small Parcel Stormwater Site Plan is Required
P
Total Impervious Surface Area (sum of all areas) -E additional
-Existing
If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below.
Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property f r review and inspection as may be required.
X OwnerCgenD
Fontractor(circle one)Date: 11/9/18
If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign
the information provided on page 2 of 2.
Page 1 of 2
7
Rachel Weber
From: Len Williams <len@fosterwilliams.com>
Sent: Friday, November 09, 2018 9:32 AM RECEIVED/
To: Rachel Weber
Subject: FW: SR 106 MP 7.61 vicinity- Carrougher Cabana NOV 1 12018
Attachments: Carrougher Cabana 8-16-18.pdf 615
1/V. Alder Street
BUILDINIG
Len Williams, AIA
Foster &Williams Associates, P.S.
Shelton, WA
360-426-0511
From:Severson, Dale<SeveroD@wsdot.wa.gov>
Sent:Thursday,September 13, 2018 1:21 PM
To: 'Len Williams'<len@fosterwilliams.com>
Cc: 'Ronald Buckholt'<rbuckholt@co.mason.wa.us>; Heusman,Jonathan <HeusmaJ@wsdot.wa.gov>;Stryker, Duke
<StrykeD@wsdot.wa.gov>
Subject:SR 106 MP 7.61 vicinity- Carrougher Cabana
Greetings Len,
If the proposed shed to cabana conversion does not place any of the structure any closer to the SR 106 highway than its
existing footprint,then WSDOT has no objections to the remodel. While it is assumed WSDOT has a 60-foot wide swath
of right-of-way here,exactly where that right-of-way line actually is is not really clear. Therefore in this case if the
proposed remodel of the shed does not place it any closer to the mainline SR 106 WSDOT has no objections.
However, I do want to point out should WSDOT have some kind of future highway or highway related project where it is
determined the structure might be on WSDOT right-of-way that is needed for the project, it will be the homeowners
responsibility to relocate or demolish their structure so as not impact any future WSDOT project. WSDOT will not be
responsible for any of the costs, impacts, or damages associated with the structure needing to be moved or
demolished. Now with that said the likelihood of such a project is very slim, but the property owner needs to be made
aware that possibility does exist, albeit a very small possibility.
I hope that helps your situation.
Dale Severson, P.E.
Development Services Engineer - WSDOT Olympic Region
(360) 357-2736 1 dale.severson(dwsdot.wa.gov
1
{
�.i 4 vYipl9yR
yam".
�45;.
y
k
f
III V
a
Y�
a
- E
t u
a, r
d -
ypre. R",�1 S � ice» y�� er �y, ,A,y �`f-� e^� ,•'ty�'*'k
e
From: Len Williams<len@fosterwilliams.com>
Sent:Thursday,September 13, 2018 11:08 AM
To: Severson, Dale<SeversD@wsdot.wa.gov>
Cc: 'Ronald Buckholt'<rbuckholt@co.mason.wa.us>
Subject: Carrougher Cabana
Hi Dale,
We spoke briefly on the phone this morning. This is regarding the following property:
John and Gretchen Carrougher
7611 E. State Route 106
Union,WA
Mason County tax parcel number: 32233-44-00010
The Carroughers are seeking to turn an existing shed into a cabana. The existing shed is near the highway, so Mason
County wants your approval for the changes to the shed prior to any permitting.
3
t
The existing roofline will not expand in footprint, but will get lower on the road side and about 2' higher on the water
side, at the highest point. The existing shed will increase in width 2'to the east, under the existing roofline, but will not
expand toward the road in any way.
I am attaching a set of preliminary sketches that describe the site area surrounding the cabana, the floor plan revisions,
the exterior water side view, and a section through the cabana, which details the height changes relative to the existing
roofline.
I would be glad to meet you on site if that would be helpful in reviewing this situation. We are hopeful that you can
provide a written response indicating that you have no objections to the changes that are proposed. I am copying Ron
Buckholt, Mason County Planner,who will be reviewing this project.
Thank you for your help with this situation. Feel free to call me with any questions.
Len Williams, AIA
Foster &Williams Associates, P.S.
Shelton, WA
360-426-0511
4
AS UN PUBLIC UTILITY DISTRICT NO. 1 BOARD OF COMMISSIONERS
OF MASON COUNTY MIKE SHEETZ,Commissioner
N.21971 Hwy. 101 JACK JANDA,Commissioner
Shelton,Washington 98584 RON GOLD,Commissioner
13UILDING Nov 1 12018
John and Gretchen Carrougher 615 W. Alder Street
7611 E State Route 106
Union, WA 98592
September 17, 2018,
Re: Vertical Clearance to Building
To whom it may concern,
I have been contacted by Len Williams, Architect for the Carrougher's at 7611 E State Route 106, Union WA,
about proposed changes being made to an existing structure that lies under the power lines owned by Mason
County PUD No I.
The existing building roof has a clearance of approximately 20' to our neutral conductor and 23' to supply
conductors.
NEC requires 12.5 feet and MCPUD 1 requires 13' of clearance to supply conductors. See attached.
The changes to the roofline would raise it by 2 feet closer to the overhead power line therefore the new roof
would be approximately 18' of clearance meeting the code.
If you have any questions or concerns,please contact me or this office.
Sincerely,
P,
Victoria Heinrich
Mason County PUD No 1
Electrical Engineer/GIS Manager
360.877.5249 203
vickyhkmason-pud 1.org
(360)877-5249 • (800)544-4223•FAX(360)877-9274
www.mason-pudl.org
jam
T-234-1(ft) Part 2:Safety Rules for Overhead Lines T-234-1(ft)
Table 234-1--- ft
Clearance of wires, conductors,cables, and unguarded rigid live parts adjacent but not
attached to buildings and other installations except bridges
(Voltages are phase to ground for effectively grounded circuits and those other circuits where all ground faults are cleared by promptly de-energizing the faulted section, both initially and following subsequent breaker
operations.See the definitions section for voltages of other systems. Clearances are with no wind
displacement except where stated in the footnotes below.
See Rules 234A,234C1a,234C2, and 234H4.)
Insulated
communication
conductors and Unguarded
cables; rigid live parts,
messengers; 0 to 750 V• Unguarded
overhead noninsulated rigid live
shield/ communication Supply parts,over
surge conductors; cables over 750 V to
protection Supply ungrounded 750 V 22 kV;
wires; cables a ui ment unground-
grounded guys; of 0 to cases 0 to Ruleg ed portions Open
ungrounded 750 V 750 V and of supply
Clearance of portions of guys meeting ungrounded 230C2 or guys conduc-
meeting Rules Rule portions of 230C3; meeting tors,over
21.5C4,215C5, 230C2 guys meeting open Rules 750 V to 22
and 279A1 or Rules 215C4, supply 215C4, kV
exposed to 230C3 215C5,and conduc- 215C5,and
0 to 30o V 6 R (ft) 279A1 tors,0 to 279A1 {ft)
exposed to 750 V 0 exposed to
neutral open supply ( over 750 V
conductors conductors of (ft) to
meeting Rule over 300 V to 22 kV
230E1;supply 750 V'1'0 (R)
cables meeting (ft)
Rule 230C1
(ft)
1.Buildings
a.Horizontal
I (1)To walls, 4.5' :
projections,and guarded
windows
I (2)To ungarded 4.5 5.0 5.0 5.50 7.0 7.50
windows
(3)To balconies and 4.5 5.0 5.0 5.50 7.0 7.5�
areas readily accessible
to pedestrians
b.Vertical 0
(1)Over or under roofs 3.0 3.5 10.0 10.5 12.0 12.5
or projections not
readily accessible to
pedestrians
(2)Over or under balco- 10.5 11.0 11.0 11.5 13.0 13.5
rues,porches,decks,and
roofs readily accessible
to pedestrians 01
134 Copyright 0 2011 IEEE.All rights reserved.
r i
T-234-1(ft) Part 2:Safety Rules for Overhead Lines -
T 234 1(ft)
Table 234-1— (continued) ft
Clearance of wires, conductors,cables, and unguarded rigid live parts adjacent but not
attached to buildings and other installations except bridges
(Voltages are phase to ground for effectively grounded circuits and those other circuits where all ground faults
are cleared by promptly de-energizing the faulted section, both initially and following subsequent breaker
operations.See the definitions section for voltages of other systems. Clearances are with no wind
displacement except where stated in the footnotes below.
See Rules 234A,234C1a,234C2, and 234H4.)
Insulated
communication
conductors and Unguarded
cables; rigid live parts,
messengers; 0 to 750 V; Unguarded
overhead noninsulated rigid live
shield/ communication Supply parts,over
surge conductors; cablesover 750 V to
protection S°PPiy ungrounded 750 V 22 kV;
wires; cables
grounded guys; of 0 to Cases,equipmentomeeting d ground- Open
ungrounded 750 V 50 V;0 to Rule portions
portions of 750 V,and of supply
Clearance of P guys meeting ungrounded 230C2 or guys conduc-
meeting Rules Rule portions of 2300; meeting tors,over
215C4,215C5, 2300 . guys meeting open Rules 750 V to 22
and 279A1 or Rules 215C4, supply 215C4,
expo red to 230C3 215C5,and conduc- 215C51 and kV
279A1 tors 0 to 279A7
300 V ® (ft) exposed to 750 0 exposed to
neutral open supply V over 750 V
conductors conductors of Yt) to
meeting Rule over 300 V to 22 kV "
230EI;supply 750 V Os 8 (ft)
cables meeting
Rule 230C (ft)1 1
(170
b.Vertical
(1),Over or under cat- 10.5 11.0 11.0 11.5 i walks and other surfaces 13.0 13.5
upon which personnel
walk
(2)Over or under other 3.0
portions of such 3.5 5.5 6.0
installations O
NOTE:The clearance values shown in this table are computed by adding the applicable Mechanical and Electrical(M
&E)value of Table A-1 to the applicable Reference Component of Table A-2b of Appendix A.
rOWhere building,sign,chimney,antenna,tank,or other installation does not require maintenance such as painting,
washing, changing of sign letters,or other operations that would require persons to work or pass between wires,
conductors,cables or unguarded rigid live parts and structure,the clearance may be reduced by 2 ft.
(DWhere available space will not permit this value,the clearance maybe reduced by 2 ft provided the wires,conductors,
or cables, including splices and taps, and unguarded rigid live parts have a covering that provides sufficient
dielectric strength to limit the likelihood of a short circuit in case of momentary contact with a structure or building.
)A roof, balcony, or area is considered readily accessible to pedestrians if it can be casually accessed through a
doorway, ramp, window, stairway, or permanently mounted ladder by a person on foot who neither exerts
extraordinary physical effort nor employs tools or devices to gain entry. A permanently mounted ladder is not
considered a means of access if its bottom rung is 8 ft or more from the ground or other permanently installed
accessible surface.
®The required clearances shall be to the closest approach of motorized signs or moving covered by Rule 234C. g g portions of installations
' C9The portion(s)of span guys between guy insulators and the portion(s)of anchor guys above guy at are
not grounded shall have clearances based on the highest voltage to which they may be exposed insulators
due to ah slacks
conductor or guy. `
®For the purpose of this rule,trucks are defined as any vehicle exceeding 8 ft in height.
�r
136
Copyright 9)2011 IEEE.All nghts r, ety