HomeMy WebLinkAboutSWG Inactive - 4/12/1995 ON-SITE SEWAGE SYSTEM-SITE AND DISPOSAL PE MIT
PERMIT NO. SWG 95-D dio m n
MASON C�PUNTY DEPARTMENT OF HEALTH SERVICES -- -- & y
1 rl N
426 W. CEDAR/ P.O. BOX 1666/SHELTON, WA 98584 Date_ }—� 9. o
PHONE (360) 427-9670 Receipt No
Amount$
PROPER I Y OWNER: CHECK APPLICABLE ITEMS �/ m
( ER LAMP 61Ou L LI DATE: 1l0 NEW SYSTEM LGh//tlLi'i/ T
MAILING ADDRESS: DAYTIME PHONE: (t Cn (2
F-2yia CENTER 415 RDUbT /AL iU SW. REPAIR SYSTEM y
S
CITY: STATE: ZIP: MAINTENANCE REVIEW m
0LLIMPiA wA • 0/9501 SINGLE FAMILY IP
PROPERTY ADDRESS: OTHER UP& d c
230 3 S: , 3 Se-FAIR, WA - SPECIFY: �� 3
PRIVATE WELL
SPECIFIC DIRECTIONS FOR LOCATING SITE: U
SIDE 6EUTP—Ai_ ;8"j OE-6 0Isi7Zf COMMUNITY WELL/PUBLIC SYSTEM g N-
SYSTEM WFI#
SYSTEM NAME 0
APPLICANT
NAME AL DFJ •E. �
Name of Lot ± 323 ft.x ` 414 MAILING ADDRESS 20 U UE E �`•�
Installer Size: 2AL 4 0,72 acres �A O
TELEPHONE 20 1 �
Name of Numle,of SIGIIA URE o N
Designer Bedrooms Cpa KE,1LC1A-. X
PLOT PLAN
Draw a dimensional plot plan, ID
r chiding: tN
o
� �,,pp ,(�ra/precise location of test 1((1�7i(r/' " iholes,showingmeasured distances to
property boundaries. I�
M r
W/Entry road;other roads, ° Illy
driveways. Lj
NOTE: DO NOT DRAW IN l �.
SYSTEM DESIGN • `�r"`
5 4 lop
OFFICIAL USE ONLY. DO NOT WR(7E•BEL'OW DOUBLE LINE.
SOIL LOGS
&Ez!�2,
Depth from Original
Grade to Restrictive
Layer or Water Table: In.
DESIGNER DESIGNATION SCORES MINIMUM SYSTEM REQUIREMENTS
Finding Score Designer Level: ❑One ❑Two
Soil Type
Vertical Separation in. Septic Tank DailyCapacity: Gal. Flow: GPD
Slope k Appl. Infilt.
Parcel Size Ac. Rate GPD/FT2 Area FT2
Distance to Shoreline it. 1 Total Inspector Date
COMMENTS/COINIDITAONS FOR APPROVAL !�
r
�n • n -rl �. c�
T-1
•All septic systems must be designed and installed by contractors certified by Mason County Department of Health Services,unless prior approval is
granted by the department,or the design is by a professional engineer.
•Septic permit approval does not imply other building site requirements(i.e. RLC,Water Adequacy)have been met.
•Any change from the specified use of the property or any site alteration affecting the system design may invalidate this permit.
•This permit e 2 years from the date of site review.Denial of this permit may be appealed to the Health Officer within 10 days of denial data.
SITE VI DE R V Approved j Not App ov d INSTALLATION:U Approved ❑Not Approved
BY: ATE: BY: DATE: BY: DATE:
TOP: Health De t. Copy IDDLE: Designer's Copy BOTTOM:Applicant's Copy
Cl.LI
' DESIGN FORM - PAGE ONE NOV 2 11996 x..I..d 07/28/95
A design will be reviewed when 3 copies of each of the fbW%W&%4j%ms are submitted:
• Completed design form that has been signed and dated
• Completed Resource Lands and Critical Areas Checklist attached
Scaled plot plan, including all applicable items on checklist
Scaled layout sketch, including all applicable items on checklist
Cross-section sketch, including all applicable items on checklist
II PARCEL IDENTIFICATION II
Permit Number ��i��--��"�^ Designer's Name NAB- 4)6aySW
Applicant's Name 44,' _ P&L-EUSRH Prop. Owner's Name II
Mailing Address '? 004 M:u02 /lJ6 E. Mailing Address 5 1R
une&UL& WA. q,01o2- 1 All
ity braceQpTVtsiVaD
Assessor's Parcel No. vivelve- ZIP
Subdivi�ionH�dffiSJSrpRRj OTT>�I
II DESIGN PARAMETERSVf
I�
Designed
II U I
rL-1 rL, vertical
I� LJ IJ Idl Se aration II
Mound Subsurface Pressure Gravity Bed Trench in
H Septic Tank/Drainfield Specifications 19f rl II
No. Bedrooms — ��;p�— Pressure Distribution? r� Yes No
Daily Flow 9� �:9...................... (If yea. Proceed. . .) ..................... .
......................
......................
U Septic Tank Capacity 7-000 gal
Receiving Soil Type (1-6) 4-
Receiving Soil Appl. Rate b f 2 ( Laterals .�
Trench/Bed Bottom Area ` ft Schedule/Class
p f gth Bounty Dept• Health Serve+_ 4T_
11 Trench/Bed Width Mason V Trench/Bed Length ft AppRO 5 in I,✓
iameter
h Elevation Mee r tnttt8�a; �� 5
n Original Drainfield Area .atit}oa Doi ��Jdh6/�yf7 (4 ft
Drainfield Area Slope if Altered M1 (D �°f ,L f�
r to Number of orifices L
N Depth of Bottom of Trench/Bed 20 in Diameter Ifo" in II/
B from Original Grade r Spacing
u _M in Manifold
vownslope Schedule/Class scl , 40
Nn Length I()"I-' ft
Infiltrator Used? U Yes No Diameter _j in
U n Transport Pipe
Pump Required? Yes LJ No Schedule/Class S� 4a
�j: ............... i8 (if yes, Proceed. . .) 29EE2...................a Length 22�fuu+8�E4uW.Leu 6n. _ 3 D ft
::::::::::::::; I Diameter 3 , in
OF
Pump/Siphon Specifications I Dosing and Pump Chamber I�
II Difference in Elevation Between Shutoff # Doses/Day IY
Nft Dose Quantity l02 gal
and Uppermost Orifice I
rl I Chamber Capacity /700 gal
(I Uppermost Orifice is 9 higher, L--flower /�
h than Pump Shutoff � I Check the following components if they drain II
N Capacity Q Tot. Pres. Head erm I between doses:
II Calculated Tot. Pres. Head 28. T914 ft k II
(Attach Pump Curve) •
��ii Laterals Manifold Z Transport II
i
DESIdN FORM - PAGE TWO ". 10.d 07/26/95
N DESIGN CHECKLISTS II
Scaled Plot Plan I Scaled Layout Sketch i Croas-Section Sketch II
Reference depth from orig- II
Test hole locations I Drainfield orientation I inal grade:
I and layout
11 Property lines I r5i Septic tank lid and II
1 Trench/bed dimensions and I drainfield cover depth II
II U Existing and proposed I critical distances within I II
N�a wells within 100 ft I layout I Reference depth from orig- II
II of property lines i n I inal grade and restrictive II
D-Sox/"T"/"L" locations i strata:
H U Critical distance I
measurements to cuts, I Septic tank/pump chamber I Laterals, trench/bed
banks, surface water I location I top and bottom II
IIu I I ri
Location and orientation I Observation port location I u Curtain drain collector II
N/A of curtain drain and all I I
H absorption area I Cleanout location I U Sand augmentation II
11 components I
11 I 0 Manifold placement I No external reference needed:11
Location and dimension I I r--i II
11
of primary system and I Orifice placement i U Observation ports and cleanouts II
reserve area I
I Lateral placement, with I II
Buildings 1 distances to edge of bed I Additional mound information:"
II I �u al alarm I u Upslope and downslope II
Audible/visual Audible I
/IC1 e f Slope
11 Direction o P i referenced I fill width 11
indicator
11
Waterlines 14a 11
Scale of drawing shown I U Settled cap depth at
I on scale bar I center and edge of bed II
Roads/easements/ I 1 n11
11
driveways/parking I Additional Mound Information: I u Sidewall slope 11
r1 I u11
II � Critical resource lands I U Endslope width i UP/downslo a P bed elevat.sad II
11 (if applicable) l i r,
Overall fill dimensions omnletad Resource Lands 11
(1�! North arrow and scale of I I Critical Areas Checklist
II drawing shown on bar I I
p DESIGN APPROVAL 11
II r1 2 does not, waive the re irement to be notified by the 11
p The undersigned designer u does, 4 11
installer of the installation and given 48 hours to perform a final inspection prior to
II cover.
II
II II
II The undersigned has revi d a 2s ed this design on behalf o Ma County of Health II
11 Services. (� Q 3 n t� Va� II
II O Y UNDER THE FOLLOWING CONDITIONS:
q GUTIONs DESIGN APPROVAL I8 . ID QL
v/ THE DESIGN IS STAMPED -APPROVED- BY MASON COUNTY DEPARTMMENT O HEALTH SERVICES II
v/ THE ON-SITE SEWAGE PERMIT HAS NOT EYPIRED7 EXPIRATION OF SAID pMaT IS BASED ON II
q THE DATE OF INITIAL SITE INSPECTION, NOT ON THE DATE OF DBSIQN APPROVAL 11
11 ✓ THE SYSTEM IS INSTALLED BY A CERTIFIED INSTALLER, UMLESS PRIOR AUTHORIZATION IS II
OBTAINED FROM MASON COUNTY DEPARTMENT OF HEALTH SERVICES ��
B-L/IVB Dft wooiiiscroft
Septic&construction (toe)426-U21
August 4,1997
Tot Mason County Dept. of Environmental Health
Ret Addendum for the septic installation of North Mason Library
Dear Sanitarian,
Listed below are the proposed changes:
(1) An eight inch Biotube on the Septic Tank outlet,
(2) septic pump to be set on blocks in order to hold it
12" off the bottom of the pump tank,
(3) float tree to be installed,
(4) 2,000 gal. concrete pump tank to be installed,
(5) drainfield dosing to be changed from 500 gal/dose to
a lesser, more frequent dosing based on actual pump
run time and
(6) valve boxes for lateral control.
a
w"lliscrof , esident
Mason County Dept. alth Servicesnstruction Inc.
App'R VLLJ
Initials — `P
pate 6 1 yvrgllL �'^�
NOV Q 06
MASON COUNTY DEPARTMENT OF HEALTH SERVICES i TH SERVIrn
POST OFFICE BOX 1666
SHELTON�)WA 98584
FFAXX 427 7798
APPLICATION FOR VARIANCE/APPEAL
Directions
1. Complete Part A and sulmit to the Director of Health Services, PO Box 186, Shelton, WA 98584, along
with one of the following fees (as appropriate): $26 for appeal; $21 for staff review; $93 when Health
Officer review is necessary; or $113'when State Department of Health concurrence is necessary.
2. Staff and the director will make a recommendations to the Health Officer in Parts B and C.
3. The Health Officer will make an initial in-house detenvinstion in Part D.
4. The applicant, if unsatisfied with the. initial Health officer determination, can request a Health
Officer Hearing.
Findings and determinations of the Health Officer my be appealed to the Hason County Board Of Health.
�Zl .Part A: Appeal/Request for Waiver 12�o0
• Applicant's Name: HAL uA[eW-%D,4 3usu QON MR TUC..
• Address: a00q MI140e AM E
• SEATILL— IAJIq gAlOZ
• Telephone: ( a OG ) 2Q - 4144
SAI-\ 15,-(HE-U-11K ADP, FoRnow OF 19W 14 11.
Assessor's Parcel Number Subdivision Name and Lot Number
Nature of variance or appeal:
Reduce separation between urimarv/reserve (circle one or both)
drainfield area(s) and from feet to
feet.
fY�-T Appeal findings or conclusions of environmental health staff (please
specify) : l�
Qf�(
Applicant's Signature Date
N,%Off-5ZMVARIAtKB.N Revised+ 01/07/96
■
Part B: Staff Findings
n T��1'
u Applicant owns the affected welt HL Soil texture provides for treatment of sewage
n
:__I Applicant does not own affected Weil, Soil depth provides for treatment Of sewage
but owner has been notified n
U Enhanced sewage treatment will be utilized.
Parcel ea:vet be developed Without variance Specify type:
Oth el G all &W, �Q
�SLo Ot`I on ar
t il law v tb
'�� �n L194t1i� p�i} uti 8ti , tb - n 11t.. �1,Da^- 01?
Env' amen Health Speci Sate
inn FM 3#�Iqfwur
P�artt C: Directors Recommendation
r;, Direct/o'r recommends
approval of the variance or appeal, sed an the following considerations: R 9c+e
Lj
v Director recommends denial,of the variance or appeal, based an the following considerations:
7/4fi6
Dir cto f Health Services Date
Part D: Health Officer's Determination
n
u The wealth Officer has determined that approval of the request for variance or appeal will not have an adverse
effect on piblie health and the variance or appal is hereby granted. This decision is based an the following
findings-
n
LJ The Health Officer has determined that approval of the request for variance or appeal has a potential for an
adrorsa affect an py81ie iealth and the variance or appeal f6 hereby plm:tad. Thia decision fs based on the
following findings:
Mason County Health Officer Date
Ni Km-OZINWARZANCa.N Revised, 01/07/06
i
j:
y 4iil4r.
r r4 FIZ.::. .. : ,.
y � , ` I:ti-r •{� - �,�� ti,�ti�:��"tip�tirr.-
A
i f
r t r -off
; 3 4' � ' C�Rr► i c�2�6t�yx ��-lo�r'Ver►�;.1 ���v
M7
SL IL
MOO
ti
`. f"Zi�1clas
• Isr, ;� �1i
earn
! 3 ! V135 dyer, 0�1a d1 �1
Prue
�>i win. — .. .; ..;:.. •.
dl
1405
77
: -
_ _.
H'8'9 S£iL£Z£99Z
L2•LS 961 60 21�i �-d SZL-1 £90-d `�/
r
NOV 2 1 1"6
TH SERvi
ENGINEERING REPORT
FOR
WASTEWATER TREATMENT & DISPOSAL
PROPOSED NORTH MASON COUNTY LIBRARY
BELFAIR,WASHINGTON
Prepared by:
BUSH, ROED& HITCHINGS, INC.
2009 MINOR AVE. E.
SEATTLE, WA
L)R4F * 6152°li.
�Se�c
AUGUST, 1996 jea�i A
QeQt. v
Revised November 15, 1996 �Vo�c�A��
*ate Y Vj
�4`0��.
■
INDEX
COUNTY DESIGN FORM PAGE 0
INTRODUCTION PAGE I
WASTEWATER FLOWS PAGE I
DESIGN OVERVIEW PAGE 3
WASTEWATER FLOW DOCUMENTION PAGE 5
SITE SOIL EVALUATION PAGE 6
DRAINFIELD & PUMP DESIGN PAGE 7
DESIGN FORM - PAGE ONE n vi..e 07/28/95
A design will be reviewed when 3 copies of each of the following items are submitted:
Completed design form that has been signed and dated
• Completed Resource Lands and Critical Areas Checklist attached
Scaled plot plan, including All applicable items on checklist
Scaled layout sketch, including all applicable items on checklist
• Cross-section sketch, including all applicable items on checklist
II PARCEL IDENTIFICATION II
II Permit Number Designer's Name HAL 40&ab.tStni II
II Applicant's Name `-4� Prop. Owner's Name 1�M uD2EblOi!'NLi.P.�7 y
II Mailing Address 'Z t9rQ Miun2 ao E.. Mailing Address SE42 ' e Ctr 2
it z3e Z]'Lt WA . gA)zz AigRl2 RLWPLI SW 11
II -iy statelY de 6ip lill
II Assessor's Parcel No. Subdivision RAJ ELZR ADDlp02Ra4rOFMi
IIji-welve-vigit NU17059Yri`Ui'TIdP�"B'Iab'F']
II DESIGN PARAMETERS II
II ✓ ✓ ✓ ✓
II I 1 ,�1�, r 9; Designed
u II
II 13i �i u � Vertical
II Separation
II Mound Subsurface Pressure Gravity Bed Trench 1}(0 in I'
II Septic Tank/Drainfield Specifications I
II No. Bedrooms N A Pressure Distribution? Yes u No II
II Daily Flow (o d I: ...................... (If yes, proceed. . .) ...................... :II
..............:
II Septic Tank Capacity 2 D0 D cal I
II Receiving soil Type (1-6) 4-
II Receiving Soil Appl. Rate ft° I Laterals
to II
II Trench/Bed Bottom Area 1(j3i ft' I Schedule/Class 5�� 4 b
II Trench/Bed Width ft I Lengtk) 5& Mn.K ft II
II Trench/Bed Length Sy V ft Q(( 4 71
h / �` iameter I.'L5 in II
Elevation Mea uramante �� (�� ` � Number (�. ��7 15 II
II Original Drainfield Area Slope I Separation ft II
II Drainfield Area Slope if Altered t I Orifices II
II ,� I Total Number of Orifices 2 5
II Depth of Bottom of Trench/Bed 2 OT in I Diameter llo" in
II from Original Grade ups.Lope r I Spacing V421e"S II
II .� Oin I Manifold
II ors op I Schedule/Class S4 40
I' 17-1 I Length 102' ft
Infiltrator Used? I__I Yes No I Diameter 3 ` in
Transport Pipe II
II Pump Required? Ili Yes LJ No I Schedule/Class 5CA 4a II
...................... ::::::::::::::::::::::::::
(If yes, proceed. ) I Length 22 QUu4Q'EQ9W LEu6n, 30 ft
II �� I Diameter 3 in II
II Pump/Siphon Specifications I Dosing and Pump Chamber II
II Difference in Elevation Between Pumpp Shutoff I # Doses/Day 2.5
II and Uppermost Orifice IZ.t5 ft I Dose Quantity 4(9Z cal
II 17-1 I chamber Capacity /700 cal
II Uppermost Orifice is 9 higher, u lower I II
II than Pump Shutoff I Check the following components if they drain II
II Capacity ® Tot. Pres. Head 11Z. dmm I between doses: I�
II Calculated Tot. Pres. Head 26. 9 TD{J ft
II (Attach Pump Curve) I Laterals Manifold E Transport II
i
i
DESIGN FORM - PAGE TWO ne�Ts.d 07/26/95
' II DESIGN CHECKLISTS II
Scaled Layout Sketch I Cross-Section Sketch II
Scaled Plot Plan i I Reference depth from orig- II
II Test.. hole locations I Drainfield orientation I final grade: II
and layout I
II I I Septic tank lid and
Property lines II
Trench/bed dimensions and I drainfield cover depth II
II u Existing and proposed I critical distances within I
II `J/0% wells within 100 ft I layout I Reference depth from orig- II
of property lines I inal grade and restrictive II
II IHU D-Box/"T-�/"L" locations I strata:
II r ,
u Critical distance I
measurements to cuts, I Septic tank/pump chamber I Laterals, trench/bed
banks, surface water I location
top and bottom
II I r' II II u I I u Curtain drain collector
Location and orientation I Observation port location I f�
N/A of curtain drain and all i I LJ Sand augmentation
absorption area
II Cleanout location
II components i Manifold placement I No external reference needed:11
Il
IILJ Location and dimension I n
I �i u Observation ports and II
II of primary system and i Orifice placement
cleanouts
reserve area
I Lateral placement, with I
II 0 Buildings I distances to edge of bed I Additional mound information:'I
III uUpslopeand downslope II Direction of slope Audible/visual alarm
11
indicator I referenced I fill width II
I I rl
Waterlines I Scale of drawing shown I u Settled cap depth at II
II
on scale bar I center and edge of bed
11
II Roads/easements/ I I n II
driveways/parking I Additional Mo11
uad Information: I u Sidewall slope
II I = I r, II
Critical resource lands I LJ Endslope width i U Up/downslope bed elevat.
II (if applicable) I n
U Overall fill dimensions I co=leted Resource Lands and II
II North arrow and scale of I I critical Areas Checklist II
II drawing shown on bar
II DESIGN APPROVAL II
n
The undersigned designer u does, &does not, waive the regirement to be notified by the
installer of the installation and given 48 hours to perform a final inspection prior to
II
II cover.
II The undersigned has reviewed and approved this design on behalf of Mason County of Health II
II Services.
n II
II CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDITIONS: II
✓ THE DESIGN IS STAMPED -APPROVED- SY MASON COUNTY DBPTARTMENT OF HEALTH SERVICES II
THE ON-SITS SEWAGE PERMIT HAS NOT EXPIRED: EXPIRATION OF SAID PERMIT IS BASED ON II
THE DATE OF INITIAL SITE INSPECTION, NOT ON THE DATE OF DESIGN APPROVAL II
II �/ THE SYSTEM IS INSTALLED BY A CERTIFIED INSTALLER, UNLESS PRIOR AUTHORIZATION Is (�
II OBTAINED FROM MASON COUNTY DEPARTMENT OF HEALTH SERVICES j
INTRODUCTION
This report details the results of an investigation and design for the wastewater treatment&
disposal system for the proposed North Mason County Library, located in Belfair, Washington.
The report was performed as a subconsultant to Donald Carlson Architects and was authorized by
contract.
The purpose of this report is to develop reliable estimates of wastewater flows and to establish a
design for treatment and disposal in compliance with current Mason County codes and
requirements.
The project is located in the central business district of Belfair, at 23081 Highway 3 (SR-3).
There is currently a library at this site. The project involves expanding the library to serve the
growing population of the area. The adjacent parcel to the north of the site (formerly owned by
Careen&Don Woods)has been purchased and is a part of the project.
The site slopes to the west with approximately 20 feet of relief overall. Portions not otherwise
covered by gravel parking or building are covered by forest and brush. A large wetland has been
indentified and surveyed along the western edge of the property.
WASTEWATER FLOWS
Table 1 of Section 4.234 of the "Criteria for Sewage Works Design" prepared by the State of
Washington Department of Ecology (DOE)provides a design basis for new sewage works.
There is no listing for libraries. Other sources, such as the EPA 'Design Manual" and various
local county guidelines were consulted but yielded no specific library listing. The closest
approximate use is for theaters, where flows of 5 gpcpd(gallons per capita per day) can be
expected. However, the nature of libraries is quite different from theaters, in so much as many
patrons spend only a few minutes picking up or dropping of books.
Estimates of the expected wastewater flows from the proposed library can be determined from the
historical water usage at other similar facilities. The Washington State Department of Health "
Design Standards for large onsite sewer systems" suggests a minimum of 3 comparable facilities
be evaluated. We have obtained water use records for 3 libraries, and an estimate for a fourth, all
located in western Washington State. Attached are miscellaneous correspondence documenting
water uses and library demographics. We have tabulated the data for comparison. Table 1
includes statistics of meeting room facilities, patrons, building size, and employees for
comparison. Since demographic information provided us came in several different forms, we
found it necessary to estimate patron counts from circulation in some cases.
Water use records have been selectively analyzed for winter periods only to delete otherwise
erroneous anomalies reflected by summertime landscape irrigation water use.
page 1
■
The average daily water usages at each facility are:
Library Average Water Use
(gpd/patron)
Aberdeen 0.47
Shelton 0.75
Parkland/Spanaway 0.37
South Hill (Pierce Co. # 1542) 0.50
Average 0.52
Maximum 0.75
As can be seen, there is a fairly consistent range of water consumption values at these facilities.
Meeting facilities and staffing requirements appear to be relatively equivalent, and are included in
the wastewater estimates. Therefore, a conventional approach is to equate design flows directly
to patron count. The calculated consumption values can be equated to wastewater flow per
projected patron for the purpose of design. It is expected the wastewater flows from the proposed
library will be similar to these other libraries.
Meeting activity is of particular interest in developing wastewater flows for this particular project.
The referenced resource materials indicate that meetings facilities and auditoriums generate 5
gallons/occupant/day. By comparison to the average library flows, meeting flows are much
higher. Although, as stated above, meeting activities are included in the wastewater estimates,
potentially large wastewater flows from meetings should be addressed separately because monthly
domestic water use records cannot reflect the sharp daily "spikes" or increases in flows from
meetings. Meetings can occur periodically and inconsistently, and the disposal system must be
adequate to handle these larger flows as well as the normal "backround" flows associated with
normal library operations.
From Table 1, the estimated patron county is 550 people per day. The estimated maximum
meeting capacity is 150 people per day. Consequently, the project daily design flow is computed
as follows:
Library operations: 550 patrons/day x 0.75 gal/patron/day = 413 gpd
Meetings 150 attendees/day x 5 gal/attendeeJday= 750 gpd
Total Daily Wastewater Flow 1163 gpd
page 2
■
ON SITE SEWAGE DISPOSAL SYSTEM
Regulatory jurisdiction over the sanitary system is controlled by the Mason County Department of
Health Services, since the anticipated flows will be less than 3500 gpd. Rules and regulations for
design, use and maintenance of on- site sewage disposal systems in the county is contained in
Mason County Department of Health Services 'Design and Construction Standards", revised
3/2/95.
The system will consist of a separate septic tank and pump chamber The pump chamber will be
controlled by a clock activated dose timer(such as an Orenco Systems A-1 control panel)to limit
hydraulic overloading of the drainfield soils. The pump chamber will be over-sized to provide
extra reserve capacity so that periodic unanticipated flows which exceed the drainfield capacity
can be metered out at acceptable flow rates over the ensuing several days. The effluent will be
discharged to a pressure distribution drainfield which will maximize the drainfield efficiency by
effectively distributing effluent to all portions of the drainfield uniformly
Seplig Tan
i
The County Design and Construction Standards do not prescribe the size of septic tanks for
commercial/institutional facilities. The Washington State Design Standards for Larger On Site
Systems require the volume to be at least 1.5 times the daily design sewage flow. The tank must
be divided into two compartments with two-thirds of the volume in the first compartment and the
remaining one-third in the second compartment. The maximum allowable water depth is 6 feet
and a minimum of 20 percent scum storage must be provided above the design liquid level. The
resulting septic tank configuration is:
Characteristics MinimumRequired- Aesi¢
Sewage Flow(gpd) 1,163
Septic tank capacity (gal) 1,745 2,000
A pre-manufactured tank will be used. A polyethylene screen assembly should be installed on the
outlet piping from the tank in order to filter tank effluent. The opening size in the screen should
be a maximum of 1/8 inches.
page 3
■
Dosing Pump & Chamber
Design of the Dosing chamber and pressure distribution field will follow criteria established in the
Washington State Department of Health " Guidelines for the use of Pressure Distribution
Systems". For Silt loam to sandy loam soils, the guidelines recommend I to 2 doses per day.
Using a single dose per day establishes the required size of the chamber. However, a dose timer
will distribute those flows periodically throughout the course of the day. A 72" diameter manhole
section will be provided as the dosing chamber. Normal depth within the chamber for 1163
gallons will be 5.5 feet. An extra 2.5 feet of reserve capacity( or 528 gallons) will be provided
below the gravity inflow line from the septic tank, for unexpected fluctuations in wastewater
flows. A total liquid depth of 8 feet ( 1691 gallons)will be provided.
Drainfield & Site Soils
The proposed drainfield location lies in the southwestern portion of the project. Several soil logs
were dug within the proposed drainfield area and were reviewed by County Health Staff. The
project's "Onsite Sewage System Site Evaluation and Disposal Permit" details the findings. The
Soils are generally rated as class IV,with evidence of mottling appearing asshallow as 46 inches.
Based on these findings, and application rate of 0.6 gpd/sf will be used.
A standard pressure distribution drainfield trench will be used. The bottom width of the trench
will be 3 feet. Dividing the estimated flow(1163 gpd) by the allowable application rate( 0.6
gpd/sf)yields the required effective drainfield area of (1,938 SF). Dividing the Drainfield area
by the trench width yields 646 lineal feet of trench required. The drainfield trenches will be
separated by 3 feet of undisturbed earth such that the laterals are placed 6 feet on center. The
total primary drainfield area is 3,876 square feet. The reserve area will be 4700 square feet (over
100%)located east of the building.
page 4
WASTEWATER FLOW DOCUMENTATION
Page 5
■
BUSH,ROED R IBTCFI NOS,INC ,oe 1b�re n lltillMri '9 S 291
CIM ENGDMERS R LAND SURVEYORS
2009 Mina Avenue Pin
�. Se,"l, WA98102 wtaewlED er `+ wh 4-I-41.
323-41H
Cam) a caxoer wn
(206)323-7133•Fu
va
40
n -
y
Ul n^ a e O 21 m 3
r,
W N P
o
s i _e
_. c _. 4.. ... 7\R' Deg `Cl
,1�' "M1s�' �•�:��4'S v ,{iv4'.}4� 19 � ��1� �'� ' � 1.War .4 r IT'S
- �g
P. _
w••A•89ZPAIR IIRRRRV l •2•tT.11lt IL�T
t _
TO: VICTORIA RE)(PORD
FROM: 1CIM SCMTZ Y C"
RB: PROMCM USP OF MW BLIILDINO AT 118LPAIR
FBBRUARY 27, 1996
To the best of my ability T have been tryhng to God tho statistics needed to determine pro)ected
aveMe occOPAM of the libtuy. I think I can come up with a good projection of that Baum
From this Projetxion I can mritdse that rarely will the peak use of the librery be more than the
hKIM8(60 Vam) thna two because even when the meeting has a special event there will only
be so much pe ld* This would sat be the cue for a dtiWreds program where ditm are often
dropped off and no one parka. Dtuing the summer whim children come for summer radhtg
Prooramuk the leak might be 150 once a week for six weeks for children and their drivers to be in
thebuUding.
The 1995 Timberland annual statistics and patron count in h'braries w&door counters:
Patron Ckouladon Holdings Population Card Daily
count holder patron
Aberdeen 190.607 238.974 $6,137 16,700 15,6W 633
Centralia 224,125 301,904 80,349 12,730 18,796 744
Shelton no counter 355,437 77,119 7,555 17,439 $10
The Public Library Data Servlce,JAatlatirl Ranorts'94 lists the annual number of library visits
(ntOu of individuals entering the hUM).
South County 763 ;}
LAWWY am 229,892 294.503 89,680 24,060
During the weeks of February 5 end 20 the Shelton library It`di �ff people in the
being on
building. One of those week was exceptionally busy Y winter break• The average for the two weeks was 53.8 people in the bunding-3 o ea the_82
people at i l a.m•the day tbllowiag the holiday. -IU lower daily average
was highest was 69.7.
"``-S �. ,..
■
111111 WINry
11
' DONALD CARLSON
AND ASSOCIATES
ARCHITECTS
.�n.tunaum
=noran
tm w mm
wn-ml
Mmh6.19% RECEIVED amwwmlwn
as•n w m wt
MAR 0 7 1996
mttrtww
sm.NO 6 IlRpetl6S Irc
Bulk Rad and lBndninp.Ioc.
CYva awnem and Load Smveyas
2009 bfmw Avenge FAA .. .
Sande.WA "102 .. ...... .... _
Re: nmbaWW North mum Library-Septic System Desip
Dar 1lal,Plan rmd actoaed a copy of a Gx San Kiay Schilts and ow NOY• plem levier the comber we
• aaaated. I fed these we somwbat consavadve and should be good mnm =9coed thalha60 WPtif-
of me
symm Lta me know K ym see aoy&io{awary toddL As ym probably know wo
rystem w coon as ponhv*-
• peak Use V d.;lt I 8
• AVOW pwmpaHoar Jo
• Paum per Il bom day 5"
Ca me if you have my gwmims or cammmn mpudit thm numbem
shwerA*
b[wk wkhw
i
i
a: ,y Y .�p"at.'w �`�.��...w `.0 `�•s ..� x V � �.. s �_ `\ #.
_
a ,x,,. s
DONALD CARLSON
AND ASSOCIATES
ARCHITECTS
■r.naddwtttrm -
naar.u.a m
trnFUN
March 8,1996 modem m at rm
mutt m m 4mi
rtL tr
Kitty Schilu
Timberland Region library
Service Center 415 Airdusuisl Way S.W.
Olympia,WA. 9W01
Re: Pahon Count North Mason Library .�
Dear Kitty,
We received a copy of the It= regarding the patron Count of the throe existing libraries. We reviewed -
each and decided to use the Shelton Library as the basis for the necessary septic calculadons.Slace the -
average fiigurc of 53.8 was calculated during a holiday period we assumed an average of 50 would be a
more accurate count for normal day to day operations and a peak of 80. This translates into a daily use
court of 550 during We 11 hour period the library is open.
Thank you for the research e(t'ors. These figures will be forwarded b the civil engineer for his use in
determining the size of the drain field.
Please don't hesitate to tali if you have any comm mts or questions regarding this.
Sincerely.
Dar Carlson . . -
pc: Victoria Rexford,Librarian
Hal Hagemar,Bash Reed Hitehings
RECEIVED
gIISN.BUD t NIVIN88 INC_
__. _._ _,.__.. . ._. . . _ _ °:kit.•
DWU CFRLSON B FWM. Fax 206--M-4661 Mar 27 13:48
IFAXlow" 09P 2w
M~oraaoM#Wk cis W COW arwar
70: W HAVenson FROM: Msrk VAV=w
Don Caltson S AWOCIW es,
Ardtrlsofs
105 PONAiley
seam, WasMrgron
98101
IM10/N 11$�
Photo Toe!441-9008
�cm
FaX MOM M 1
RMWAP CR: ® UqMn ❑ Furyawrovbw ❑ Rq*AMP ❑ PNancommwK
I just received d+ws 11gures from Pleroe County. These two ubrarles Parkland/Spanaway and
South MI,B rm not mkstakan seem to reinforos our Ugures.
The South MI Ubrary is a 20,000 S.F.building with a peak patronage (during mestings)of 125-
160. The mgting room is used on an avenge of once awry day. They have a staff of 27
athough only a fraction of thow are there at one$me. (Part time and swllched from one W to
another. ) So I dwA have a good count of employess. Also,this library has a higher than avg.
we. There circulation is 781 AW per year on.
The Parklandl Spanaway
Circulation 898,000 yr.
Stab 14
100.120 peak patrons
16,000 S.F.buildng
Note almohed water usage.
DMU OVUM 8 MMC. , - Fax 2 -728- I ., Mar 12 15.25
FAXi DWe vWzW
,w,nbe,warose hatrdYn�ah..r
TO: Ha►1•fagenson FROM. Mark Wprirow
Don Carlton 3 Aseod&NM
11125 Post AMW
sOMM, wash&Wfan
aelol
Prone
Fax Phone 925-4144 MOOM 2W"I-S B8
cc: Fier MWIW 20 1
REMAMM ® UVOK ❑ Forynurrevhw ❑ RWIYASAP ❑ PNsoaCommsnt
Nat. please note the following water flows. There was no Meting for the month of March.
These are from Sheldon Pubic Ubrwy which N the one we are using as a model.
Winter Avg. 2466 ou t
April 1233 January 1440
May 1510 February 1120
June 5180
July 5670
August 7490
Sept 11740
Oct. 960
Nov. 0880
Dec. 1920
Y
" Fax 2O6-729-4 l e '2�J6�9 �:14 P.2
Gq L" m ASSOC.
_M.20 096 filmm rr j HEED LIEF 3EL7oN 4W '�
btMtab 20.1996
1Q xkwsck tx•-tsH
PROA(: Cbdsft Pbd.-AP
wK. wasrlteplbri.beedsoMmy
I win b Adma Amdem am wAa the cloy d Absdrmt WW CMQGW SRTlW
vopmmopoc HmwldtattMAb dMLMYdMMbmvamwrrarmCW=d&d6o
Clldm mmmomidermermasL
CIS blmmbl Poo0tRa6meeebimm1flmYtobidesomberdibaodialiftwo
Mir• W*b w malismditWloUm&
He'd b MPpy a mdb a ms7ms abemr dde aelL.mlm Plc m bm wacbed at(3M')s33-�ttaD
ma223.
iaa1.:�p,��,a3,... .... - .� - ��� .. •L-�.o.I�ST" �-- vec:. ,Y
� qy
DONALD CARLSON B ASSOC. Fax 206-728-4661 Mar 27 13:48
. MDR-27-19% 19140 PIERCIEe CNTY LIB DIST 2g6 537 4EW P.MIAM3 -
' . SYSTEM P O=COUr=LZIMU 8Y
MANSION 3005 - 132th St X
PROGRAM Tacoma, WA 99446
TRANSMITTAL (206) 536-M
FA7GI CM)$37-4600
To: M4 eK wi r y,eo w Date: 3-2.7-9L
1:w1c 72f- Vibe/ proj00C
oA.ne.. Kl- 3sfeG PtOJ.IF
AM. Ra INarer
We an wafts 3 pates (includes this one)
hr your:
Apprwa] Review & Commemt ��Use At Wo
Aegon Roquind:
As indicated _�None For si=aature A Rotas
14 y 1
14Y ra i. ,J.
Remarka
_ San.�TS- r �'9. 09� 9R1-C.rrt.a�
Sim_ Na.o .'f3' 3`j„ b�� c�i-�-ai
v..&t.iL- COW
1
.z
_ _ l
WI m
DQ*D CiItL" B HSMC. Fax 2%-728-4661 Mar 27 13:48
PiOF-27-1996 19841 PIFACE CNW LIB MST' '46M P•OW&VO
1 .
Water Consumption
Pierce County Library 1542
ver Gamm "
,lo . O„ a" a WON 4.= 9.900
ON 0 11�210 4 OM 42,410 16AIS Mwe
4M 91f.9/0 9,MO 740 USS
yM M9.M0 6,M 1,w6
19JM OMAN DAN 797 IA"
low 9M.1= 6040 9,091 19.N4
Of94 997,990 112 MO DIPO 17.077 3.710
4/04 OM.710 9.110 wr
M
aft 674.w0 4.720
law 9w,w0 5.250 am IA41
6 M 0191M M130 96.677 16.182
7IM w9.9w 79 w0
HM 9w.140 M3 ;1N
am �'� 7,220 w9 2.149
wo wow 7.900
11M w1,910 42,900 5.703 1Q,019
wn 47CM 90.120 ti M 28.40
TM 359" 34MO 440 1 795 '�
9Aa 949.00 9.m. 9w Ion
0
-a4awd as 7 days a anak
FV
MMM
ILL
Y - 9
DMILD 044-SON 8 ASSOC. Fax : 206-728-4661 Mar 27 13:48
WIC-27-096 10:41 PIERCE CN Y LIB DIST ' 206 537 46M P•003'0B3 .`
Gallons Per Day (6 days/week)
FD-
0
i 0
! cr 0
iN
t
( � (D
�•
e
TOT1a_ P.m
Drainfield and Pump Design
The pressure distribution system is designed according to "guidelines for the use of Pressure
Distribution Systems", published by the Water Supply and Waste Section of the Washington State
Department of Social and Health Services;September 1984, and hereinafter referred to as "PDS
Guidelines".
The accompanying table is a compilation of design parameters and variables as set forth in the
state guidelines.
/C-Wumn l of the table represents the numerical designation of the lateral as shown on the
/en eering plan.
Cam represents the elevation of the lateral, based on the topographical figure attached (taken
from the project survey) and accounting for the depth of cover as shown on the typical trench
section of the engineering plans.
Column 3 represents the residual head (measured in feet) at the distal end of the specific lateral.
This value is suggested to be 2 feet in the literature. We have used 3 feet to provide an additional
safety factor and assure adequate pressure.
Column 4 represents the length of the manifold to the lateral.
/ Column 5, Manifold Head Loss estimate
bbb Assume total manifold headloss = 0.1 x resdival pressure head(PDS Guideline, pg. 15)
= 0.1x3 ft. = 0.3ft
Check: / Orifice flow per column 12= I I2gpm
3" diam. pvc (c=150) @ 112gpm, vel= 5fps, head loss(HL) =2.47100'
per nomograph
Therefore, total manifold HL= 2.4/100 x 1021f=2.4 feet
Sinc this value is approximately 10 times greater than the original value, use manifold total head
loss=2.4 feet � mc
Given 15 laterals, manifold HL per segment =2.4/14 = 0.17 feet per segment
1 mn r\psse, s the die regce baegween the lateral elevations given in column 2
Zolumn 7 represents the head for the given lateral
residual head @ distal end (column 3)+elevation head (column 6) - manifold head loss
(column 5)
page 8
ppfRETIHW Ipt llfltlwgol-1O1o111'�oeip'an.�lOIPd115921#i6ISu51 NRIdpM�
G v�
26�y
�3 Z -
P �
�� Fl tC In N
cr-
<37 O J O p 0 0 6 O O J O 6 6
4 x� fi d I Ul N O Sail — cP c l N N I\ S _ I
mi
I Ln Li to u-)
J �9 �9� sLri
6,- A� 4
� i
y ,, > s N c Ic 1 cn Ln In in In r
co
co
CO
' � ✓ ti ' J J L6 ltl ltl. 7'
�ln O 1n Q h 4 In O In O
,o O
�J\
s
C.S\- .s �l 6' tJ lSl W O c�
J O p- CO C C .9 lfl In d' ct"
r�
�6d In o ll O lr) O I-n 00 s
arz
o9 CSC CO &I Q0 Q cp Q3 c5' ts-- b=
- -
> i
w�sl S sIQ '557 -,W 3,tlO5
31tl0 A803NO3HO Ye3.S£iP£Z£(9oZ) Hug
YVTY£Z£(9oZ)B 031f1OltlO •��
° b-Z - 31tl0 '
Jseg MUOAV AOMK 60OZ ✓
30 ON 133HS sxo.IaAdflS QNv-1 V MWOKH"HAD
aor •:)M`SDNHCUu;V a3011'xsng
f'a represents the individual discharge for a 3/I6"orifice in gpm at a given lateral.
�yalculate the individual orifice discharge based on lateral head as given in column 7 using:
�Q= 11.79 d Z h"Z h=head in feet
d = orifice diameter in inches(3/16")
Q=flow in gpm
represents the length of the lateral from plan view
w/C lump 9
Column 10, orifice spacing:
Design the bottom lateral diameter and orifice spacing using PDS guide appendix 1. Assume
maximum length of lateral and minimum orifice spacing determines lateral pipe diameter, so that
lateral pipe diameter will be consistent throughout.
From appendix , 1-1/4""diameter lateral, schedule 40 pvc, with 3/16" diameter orifice and 3'
orifice spacelds maximum allowable lateral length of 60 feet. Since max. design length is 56
feet. OK
Minimum required orifice spacing=3.0 feet
Maximum orifice spacing= 6.0 feet
or
d= orifice diameter=3/16 in.
D=lateral diameter= 1-1/4" in.
Y=orifice spacing=6.0 ft.max, 3.0 ft min.r/
L=max. allowable lateral length=60 ft.
Column 11 number of orifice per lateral.
/ lumn 12= lateral length(column 9)/orifice spacing (column 10)
Co : Total lateral discharge(in gpm)
=discharge per orifice(in gpm) (column 8) x number of orifice per lateral ( column 11)
Column 13: Lateral discharge per lineal foot of lateral (in gpm/if)
= Total lateral discharge (column 12)/lateral length(column 9)
Complete table beginning at lateral 2 using iterative trial and error process . Begin at column 8
and vary orifice spacing(column 10)to achieve targeted lateral discharge (column 13) within 15%
maximum deviation.
page 9
Manifold Design
Per PDG guide pg. 14, step a-6, the stated intent is to design the manifold so that variation in
orifice discharge rates(per If) does not vary more than 15%. As seen from column 13, values
vary less than 15%
Max value=0.189 gpm/if CZ
min. value=0.160 gpm/if
(0.189x .15) - 0.189 = 0.160 OK
check: table 1, PDS guide pg. 13, total manifold flow= 112 gpm, diam. = 3", lateral spacing= 6'
max. lateral =6' (assumed to be defined as 6' of manifold between laterals). OK
Design of Pressurization System
Per PDS guide pg. 18
CA Determine Dose Volume /
Per table H -recommended dosing frequency for saraly loam= 1 to dose per day
Ave. Daily Flow/2 = 1163gpm/2 = 581 gpm
C.2 Determine total orifice discharge from column 12 table(112gpm)
C-3 Calculate Total Friction Loss
Controlling friction loss will be taken at distal end of last lateral
From nomograph(attached)
Transport pipe HL
Q= 112gpm
D=diameter= 3"
straight run length= 22'
equivalent length for 90 degree bend= 8.5 '
C— length=30'
C 150 VC)
HL 8'/1000'x 30' =0.84'
page 10
Manifold pipe HL
per PDS guide pg. 20, assume 1/3 of total HL applies
Q= 112gpm /
D= 3" diameter
L= 102'
C= 150 (PVC)
HL= 28'11000' x 102' x 1/3 = 0.95'
Lateral Pipe HL
Given max. HL will occur at t run , length= 56'
equivalent length, globe v ve= 29'
L =total length =85' +�
D = 1" diameter- -�
C= 150 (PVC)
Q = 10 gpm(per column 12)
HL= 10.46 x L x O'.8s
C1.85 x D 4.87
HL= 10.46 x 85 x 10 'es = 5.93'
150l85 x 0.87
Therefore, Total Pipe HL= Transport HL+Manifold HL+lateral HL
= 0.84 + 0.95 + 5.93 = 7.72 ft.
CA Calculate Total Elevation Lift.
Z = lift=highest orifice elev. - pump off elev.
= 191.0 - 178.2 = 12.8'
C.5 Total Dynamic Head (TDH)
TDH =Residual Pressure+Pipe HL+Lift + *Pump Station Losses
= 3' + 7.72' + 12.8' + 5 ' = 28.5'
* recommended per manufacturer and standard practice for pump station design
C.6 Pump Selection
Use Orenco PSE 150 or equivalent sewage pump to yeild 112gpm @ 28.5 ft. TDH
115/230 volt, Single Phase
See attached Pump Curve
page 11
C.7 Pump Cycle
Normal volume in 72" manhole @ 5.5' depth= 1163 gallons
Min. Dose Volume= 462 gallons(step C.1)
Min. Dose time=462 gallons/ 112 gpm=4.5 minutes
Dose cycle should coincide with operational hours of library. Therefore, recommend 1
dose every 8 hours. Total dose per day= 3 x 462 = 1386 gpd which is roughly equivalent to
ADF of 1163 gpd.
END
Page 12
I
�51 �kj
rsr lye. ,�rarb9r�i -
, ��b9nd9�rr�aLb'�ra ��i 1VjF1;ra "LA �'j5r°�3!j/;I�Vj' ��t.vi,i ■
irt,"��r�■�'1rP;�}i�l��r� r,.`�Irr/ ..::+r� I Iir�/'!1'i � .fF�L I;'!I■
i'�I�PtFI/W/ IS"�1PIrIr I f e:ir�� 'rr as"�rr3'd, f�If!/ =���'� '1■
I�aSii�l�°d'i`1 �1� , ��/ >�': �1 � �i'r�"l�f� �+� ' 4/■
t�i�CYI" R/�iSffi�O' ■ /r�ra LI".�1�1r
l47�,rai anus �s :arl r/ 9�� ,an/ ,rurc� 1,3-PAIMAl`xAF
t,rR/761A9I :aaI �r a �srr aa,..�? rs na ti�cVnAriA� !n9/1C `� ' ra�e�: , a�i,vr rr�A�lg7 3/ AIIWMFAIwlyua■&Irr. ramr .Il"- d ■s/s�a�.nr �,.
In
O�.fww■r■wr.."+7 r1■raaa/ ' nJ1I7'AA7■1 rr✓' '�iv,^II C•`Al/as:0=11 1
Irw'i.■t.wrr.ir:° ■wnrmf sa y raa�racr�I��!Rlllralfl c+amarr C
IrArwwora�eJ,aaaw■ea® a!wra=nr,o�Ira a .!
rwr�rlrn■w5.w�■or - • .r. -.�I�ee r•► r-r■ccacw�rrz wu° '
�LiGaala'/,■adarlr/" Irr■U�,.■//vw`m' 01 LCILL^' w.as
a■J. • Fair rrriem �r'7
rf■'. ■fr I! rrwa lnrv�r�rvr�n'^'�n vi�� n
�ia111•IlI Ir./• B1 1r' ,f9;ttrw,%glrr
ONE! 9iIf al rrw 'G-a ',,•.' :",As,l r:;s° :,-1���° i ri
I -• ��..wp■1� I �♦ H'Ir 16*rrlbAli
r,L,�, I Ir'.e Nor
•®! 7 -. � 9eo ate•
rwr r-rr �.wr Gr tiro- - a r
�,Z4rC;
asw ■ /ar/rru11 a�sn w ry IY ':arAril S7. , MFM yC:12 lunw�,
® ■`wrwww/rv=IqO L�urJl nr/rS/G Cr�IrSo1�13'!ii'I Man
�rwr iw.mmm,j wwsarr x:xr�aal�cbwn �aanmw r 41111111.7FAI
wwwl I■as wa-■tort/I rr OPi CC �a�n� 7ria�'R 11C���/��ar ,MAeE
ra■II/Iar ma !/A Olf]d•�/rrlFil�L,I■Ir QlltifA LG7 rli lr
rwr7■■asw�F0 =FY i iOa .ATs1',�rr1.:•'nm �.1AI [Sc ,aa%Y
■w/r/I�II�r.r,l!•1 N/ wftQRB��f:'taa"a/R1 �Mf,1'ar��r �-
u°/.,v�w��wrr� ■m lrnaal' .rr: rre■fwr i►Ia4m,n r9e
rwrwrrlwr,� slrr ♦ "al f /favQaarall.�■ rnp
r.Irurar�,w,'rlim � arm
Crtemzlrv.lrfl�v sway nlr�3 ,
r rwwl�rr_,•�.f.rr ! n.•avrrrmrr�v.r.�n��.rl�C,rB.M wl�� I���•/
rrrw.�rrr.rw..r�.r .f..a�r.++r n,_e.w wr t.a Irrl •Y
-rrw�rr_—..__..w�.r
i=r.:.fis�r.wr'� r� p�w -ter=•�=,aFr��,Yn7i,alb—i,g-�snlr��t'y;Qi:�r�
Azz
rwr��r... =•� r+..e�rr.rr rear° w r.-aonr rrr
.=..���._°l��__. •a�7w �r„-.:�,...�rr r�,bN.arrr���_w..°�!-._'� 'i- C.rrzt
-c=s=====-_ �'3 ��k_?-c c�_e is Yr���a�cc•��f�� '
291FA owl ca
FdfA Wri,!ar, W WON �6v11ff•,4 !'
'Pd=Fj ri►.�r�arrior r;�r,�-gin/ •eft 4.�� �
Ilri® a��r�■ 9FA N. r1�6/a r B ■ �tlgi f}�I
F9JFA I'MMAINAM Al IN
4. .J
��iira��rasr.� nrF.su ,1cxs,vn r�w� ,�c,A d�i �r n
E�/1i"ii"mmi�m"�r■��i�`�,�I J Q�t=AVIVIN_`C �"�5e"i"�paiv'r�
f./Sfl jl�,
m 07a �c�]p�Iii7mmAmnl -IN, WINJ ?litb
umpV7.C1 t l�i6Tl�n, r5 .r .I� n3.TT'. IIaIAII]r■ (� fmW -ffvVco.r'11 'try Jr ll■r M,i>:il��n r n.-rlm en r��rra��/tl'► I9F(':
..rn r �nvr, • , v�mnilmI •1 ,r/azr■r ln�r , �v �n 1 '•LVwr
rs1 w.a.'Il�realrlN wY p r rRr err -r r-r:,O a)
.rrr�■r-u1lra•rr r,will mrs:,wfrle" Br =dr�� 1
-_��tAr_�rw_r.O wwil 1 I�Irr d..rtn..1_I w i
!� �r 11 IL1 ■!! sl pet/ I 1pq r
wr.�.r.wrrrli ♦j�r', .rl�i rar=rrwre.w,r�rr �rQa�I��� r
rrrrir�r/•rilr•rrw Ir1 I�r•�frr••-rO�1 r�r 1e.rZ♦. 1.N r
=rim-.—Ilrrw■ _ r.+rr rrl m+•r r/� . �.rrr . vw
w l.w.aP 1.. = •rYir N - �rrlYa ,a_rrr.l7lrx
g_ �;���,- -
v�a�■yM67gNq�N%:Y �=rlM,F11,x ^�e�79.7N� 'A61'
a6747�a■1/"F]wl�/lt� �r Ia�S"wtY�'C �w tR., n .7 i71 rGEW.
INS w �' AwOr.IIMI er1 ■ Rwd Fr.t,..11.+/' rY9► CJ rw:61 r.+xR
%�i- IIrYI Ir]aPo A� rsl�ir•w1. e, t.�Ir.r '■Iwal Vi /rl
fi '41sIrON
BwL/,Fst^+.0 eL CH/1'/dOwlal r102h 61vri
�w■arrl ■rrl,I,w r1 ImrBJ/.b1Ir BCIn■�,mvrglrni111?rp/d': rr��
�r11� malm:jI W.O I 1 ■1 ■r 111 Blvwrr/cM19 w�►a�7t (RaI1R'
.Bmaa t ►EM gwa Ra1T ► rTR ! ® eI I-' '�l��1!■.
r ol� . •lmra■r•rw d•� v�:1=.n...w.../wrr.n l��'v^fp'rr.�ell�r/1 p�i•rfe,
re ,1rr'r•r-a1 �*. r ru r.o rr.w. -
rr-� sp a •r nr01r kvRr. 1�1lrr rr 4■E 1d51I N1iI A br�' u
r- "' jrv, wRR , �o C ,.
aE�m r.'_,P—__H— rl�tc�
®® pp�r yI 71 p ,p Ip1q 1�/ ■
r-/V/,I/e/IOral,,�lA► �C ..,Qr► /r♦rY �iG p@t1lq�lww5 �1T®i,.
r. b7 rr� �' IfFM9lvArn �L"c r
1/.AIIW1111A��llldll7 �l /@7r' IF I KIP 6f/i/`?!�s s"• �rt1�? r;
lii�=o�elswr��ra ' ► 'crs�rh��F;� 111F, �e�s�!r art ■=ar r,fi
wFir 2
�1�7/1 Ar/lryPRwr]� c7 "1 r�I / ^ �� r 9 4 "!�W3
eer PA 1r 1110�i t ) t ay E-��CIE,., r M
®.�m�eli� z� ♦� D' �tt+t.7/�'br1�IrN k'.1lrcldj ( Why)
�BasrlDLRi.yr,aatl.:lAlffi 't(sr u.c ■a4C=^1n°a`I err,
►Ir Ir Irl-A/l.f pr .f .., IIU ,r, • ...•1��7 rs C, "'rn
.yt a rr naA• / , wnv Ipf , alir.♦m� -'+
o Tl id➢!)01 �lIIr kcl
�! ..r`i, r NrAB rrrlr
_fir 3Iowa
:� .rr ! 0_
.. w:i 1 �farr ==!=w.r. t Im-AMR, Mr trrrr'-
=a�■.,E_RM..car„ sa L�I _ .�wrrn17j Ov at •■:,1�
•ww .rw �_ -+r.—n.iL w.Paw,eul arm •V r.•
�riwrw�r�r_rrr- r rrww•r�swr-r,r E ]•siltw w:ww
wr-. rrwr�r=•� •r,v.aw w.... r n• . rn�
MR
w �r�of�°�sas =wirer
• I�wwrllwl�..►®��� r� a7�r 7ar■iC"/"Ir 9■�7Ica4...I, Mill r Plw -
lua.I®r�:aorl.�l �rr aw
Ira
ST. I
mown
e =?MWIRPMA aq I lg5 aL4 .ear. `r IU"lli9 6ti:!■ ■:11■a
■ww■/te� Qa'a P■awirr *zfr■ ■r vrl aurr' ,rrur
■..r°■®► L'rw:v or.-��■r*arl•I.a t asr■w ■rc■r:.
• ■1rI1II—G rwrl'_al rr pR'mzer■rr-rf.M (It�l pp1wB// rw■-r
11�I iaa�1�1/1.y' C.N+•4a�IPs9rNfrT� 0.v�lailr■Bl■1 1B1■
11r I 1■s/Ir■�.wrl® (-J■xlla�l•t,1 rw■ r�reTr�� �1 ! O/•//
rr! ��rarurrl rI .�.-xn wr�''�f:r I I LNlrr,asil tw�FEE
.rrr rr.��r�nr rr u�sar.�� ' -.•- ,.��, rrr-1���1wrw=_rui•=..r.._���swr wr1.l.rl r.r.ri�G��s��r.:rv�����.l�'orsarwr,�i{. _i111�Q_�r1�•wea■l c�Irarmy^u��r�r�v•r.m.r^r�wn•.�l.t�vw.i� Ii C��.r=r
'.r_c
.
'wn;ZfdORIONr r i11■■i.�
.mA
2259.� _ - r=vrm r
- �-._ _� �_ �.Cry�O h"• :G�•.a�:O�L7r.. .�i'iL.'I "w .0 G
R - - mom
c)ddr� z
309
rp
-TV o- ra, lo�rn'
s lC�ani lurt7ri r,�o��
0 -f fern 23'�S 1, � �� � ya
%it lVrStZ� « Soil 6a`�C 9
c� Rod6 (� `� 8 0—y 0lo?Ws V y! '�
�Sa �oarn wi?�p�s�y
sl sorn
qPY09,001 J(.ft,572 b7& ;
1,11tvivO� tcr � `� 5 'r '-¢brEr��l
la—el Q)v4r
v F�n6 Uy 3�t ,iq� CEO l d allyee�64061
l:!/�k%
A. 75 ' �
W � !Et'LS•35--.57 C�Pmy �>� 5�� �� /7T/�s Sevre�►�y� m��C�
AY m Yr7yfc3�Ow a-
"tt
4*W M OFA
4S L6a4FQ AIv
boo&tp 130 a &fij_.g2" &t�-- 04
----------
-H-N-E SETLEZ29OZ
gc:ol 9z �Rm BOO/Loo-d GEC�l 6zs-j
DUSK ROED dC MCHUNGS,INC.
9 Woor A Venn FAR . ..
sane.ww9s102 c �cuwrme. Neer. q r 3 2c7`94
(206)323-4144 OSUM m aoe
E3FiM C^313-713S Am
®oAL9
Ok-
fff
—� I I ! ��r� -••F{..'--{--f T� I -i--i»•-ti-•-"v—�-�--j--t^��y-�"}{"f-•--�T a—r-.r_•_
__TJ'•" !.. i li/!^.= J,-al 1 ! 1 �—�—� i i n ! i �1 � 1 �•'.Z�(/.��j p(�� i ,,.......��...�,..—i__
Z ,
I i I i I
- i— ' - .
a..
-I�� �� 1 ,
it it
•• ! • 1 ! ! 1 ' i • � , •1
� ! O
it
it
--+ i i 1- i ; r--+---a-----1-•--�-.. .. 1. `. � .�—ice.—�..._{. ;_J.__-:_
�y L I • 1 1 1 !
• , ' 1 ' T� i-- �.i�..j..—i �.n—,.f••rv,p.•..•n.�r_-..a}_—i__.._i—.y-- 1 1
1 T t i i s
--�--,.+_--�. ` —+1,-1''�+'n.-,V. ' �_�;_._�-.iy'nti..v..l.w. � 1 .1_�._..i-.._•L__.r•W,�nnn•..__-1-_.i—...�._.�.._p y. _.•'_•win�...,x.._
—.+Mj.--i--_Y A_...y.r.. � � "p ...i .—L...,•n:.....,_.I...- ._� .._...i._.._y'.._.�,n-,..al...._..... q....._.�:.__...�i_.�_-1.. i
1 • ; • - y....iu...'.•.n._mil.._..._•__.� • ! a.l.... ._...� ..'n—....1...._-•J__•.:1,_.nN.'-n. .i-.
: r
I j • � ! 1 � I i � 1 : ! i !
I ! i
... �' __r—nn_rvny'u•.•J..-_.1___..}--M..•,.•x.;.w nr.l.—_r � --i-..—.p,n—..1.._.•i••—x�_•f•••_�._._--,•x"u—+--rL—� _�._... _
1 1
,-�' i.-.. --.,.i-i._-t-':_.-5...�_i__L-_.,.�_._.i_- ..•..'F'��.-yl...- .z_..i.•._n_L_ i._-• -:-•p--�:..•....i._._ _-.i_--Tom..-i...,-
j
, 1
9£:07 96, 9Z 6 44 800i800-d 8£S-1 6zS-d 'H-8'H ssir zs9ez
DOU GI " 9 ASSOC. - Fax' 2D6=72 -6 Wl .,� . hkx 12 15a26
L
i f
FAX LDim M-yW ee 1
TO: M"ice
om Owfta&
f825PbstAhey
8sat8e, WlwiOn
08101
HIone
Fix/fiats . M-4144 PjWw 208 4414M
OC: �t 20Q 1
RguAim. ® uvwM p For yourrovisw C7PaPYA&W C] Phw&Gamment
Mal. Please note the following water lbws. Th"was no f ong forthe month of AWCh.
These are from Sheldon Public Library which is the one we are using as a model.
Wittier Avg. 248d Cu &
April 1233 January 1440
May 1510 February 1120
June 6190
August 7490 30 = ??1�3 �' 3o X 9oG .
Sept. 11 740
oa. 960
Nov. 6890 V/30
Use, 1920
9£:0T 96, 9Z am 800/GW-d 8£S-1 EZS-d 'H-8'El S£TL£Z£902
09-14
MSON 6 ASSOC. 7�e-46f,1 �. ,� 2939 p.2
Fox : 206-
MiiR.20 P96 6=N2PM W" REO LI SHELTM WA '�
M ncb 2% 1996
in ltl�q�llca-SA
tOMC- C ePdd.-A1x
im wwrumvirhbp Aw9LAmY.
E
f wpob 1p Ado Aadsa as v4ftticRSW of AbMbw*s WeNrC7OMW GK"00
pepMeoasalt 11CsNdtst�sAti01d0eeL�rdoeseOcLur09w00nr10e1oradddYpthC
C!y doa aots�oefenr�a�x��-
Hoaaver.bedldsgr�litoMCw marodwowon&toaboutlowa"leetparMoo
Mpealbtro .Laa�lond�e.ua6woe,tetsa�►ato9a.ne ZS�G3 �
HaW bo�a�a.ayaae.eont+43a a� Z�ie a.a ba naiad at t�ss3-�tao .
cst22&
is
5£*0T 96, 9? 2 W 900/900-d SM-1 6M-4 -H'd'El S£SL£Z£90Z
�" J DONALD CARLSON
AND ASSOCIATES
ARCH. IT. ECTS
mn-uN
Mmd►6,1996 RECEIVED
tw�sctrrnwi
. MAa o r nss
ease, aoEn a HIMUNGs Ir c.llsl Hagamoa
sash.Road aad F oftgs,Im
cWu aodl.raasarv"W
2009 Wmor Mom Fast
Scs"WA 99102
I(a Mmberland Nomb Masan Library-septic Syarem L>eaigu
tzar list.
Plann W enclosed.copy of a fax Pwm Kitty SdMhz sad our reply. Please review the numbers we
genetated. I feel these me somewhat wma+Ative sad sboold be good numbea b ase ion AEhq the Septic.
s gam Let ma know if you sae anything contrary to rids. As you Fab.@*know we peed the men of dte
symm as won as poedble.
• Average pmroas per Haut so
• patim per 11 boar day 550
L Can me 9 you have any questims or commma regarding dw"attmhas.
sincerely
Mark wilhraw
i
K:OS 96, 9? 2W 800/£00-d 8£S-1 6ZS-d •H-8'H S£SL£2£
DONALD CARLSON .
AND ASSOCIATES I
ARCHITECTS
atananAulaml
Imtutam j
Aaq(aalarnA
nI1F1111
Much 8.1996 Ip[nallta Nl]Nt
atal111E Alf ILNtl
AFICHOMMUM
Schdhs
Timberland Region Ubrary
Savic¢Cener..415 Airdusiria►Way S.W.
Olympia,WA. M01
Re. Patron Count North Mason Library
Dear Siuy.
We meeived a Copy,of the lew mgarding the patron count of the throe existiull libraries. We revlew
inch and decided to use the Shelton Library as the basis for the memory septic calculations.Since the
alraaaw liguro of 33.8 was calculated dudug a bdW Per 7lmills iateas�iauo daily use /;e SOV J l
mom accamw emu for nomlal day to day operate
count of 530 during the 11 hour period the library is open. `)J
Thank you for the rMarch ciforts. These figures will be fornarded to the civil engineer for his use in
determining the size of the drain field.
please don't heshate to call if you have any comments or questions regarding this.
�1Sinemly,
bon Carlson
pe; Victoria Rexford;Librarian
Hal Hagmson,Bush Rood Hitchinp
R�CErv�o
WAR 12 i9W .
ggSN.ROM r N11CN►M6S iM(r
V£'01 96, 9Z 8bu 800/V00-d 8£S-1 6ZS-d 'H'd'El S£iL£Z£90Z
t .. Bz.ar.issa ' r
A BELFRIR IIBRRRV _
TO: VICMN A MMIOM
FROM: KITTY MMIZ<
IM PROJBCM USE OF NnWW BMDINO AT I1Fd.I+AIK
MMRUARY 27, 1996
To the bet ofmy abi ty I have been uying to lied the statistics needed to determine projected
avetaae occupancy of the Mrary. I think I can Dome up with a good projaotion of that figure.
Norm this projeetbnl an tau olm that to *will the peak use oftbo library be nwm than the
paridrtg(60 spaces) times two because even when the meeting has a spwW event thin will only
be so 1n A parking. This would not be the Case for a dqH m%program where dn'ldran sre often
dropped off and no one parks. Duma the xuntner what dtHdron oome fbr s mwW reading
programs, the peak might be 150 once a week for ebr weeks fbr children and theft driven to be in
tho building.
The 1995 Timbaland annual atatiatica and patron count in brarles w&door counters:
patron Circulation Hold'atgs Population Card Daily
coder holder paum
Aburdeen 190.607 258,974 86,137 16,700 . 15,666 633
Cfttfda 224,125 301,904 $00349 120730 1s,796 744
`Shelton no counter 355,437 770119 70555 17,439 510
Tho Public Library Data Setvk A Se d.tleal lteo= No the annual number of library visits
(nudlber of individuals entering the Wary).
South County 24,060 763
Limey( 294,503 89,680
the oaks of ycbnmry 5 and 20 the Sbdton Hbnuy staff did counts ofpeople in the
One of those week was arceptloasfly buoy due to a holiday and the oldldron being on
winter break The average fbe the two weeks+Has 53.8 people in the bundle$. The peek was 82
po0pho at 11 am the day fbhlowmg the holiday, 11*lowest daily average was 39.7 and the
highest was 69.7.
££:01 %. 9Z 8 W E Z00-d E3£S-1 6ZS-d 'H'd'El S£SL£Z£90Z
2053237 F-063 T-725 P-004 PPR 09 196 17:28
135 H.R.H.
y�:— ' : .1.M1 .:.:., .. .•�`��..•.. .\\ '� � Vie. � �. .; M1"
+.: .. +1.•�`��.:-:': {( � �\ ' jam\ _ �
♦ l.:
.: •�: 1 '... `..�. ';r'+^..:. .\� .. d.r• f �,(�(l.•(fey -,'(�'�^•s' ^�5.. �t:
IL
•�Y,"^M1.' .�V.!'� "` y'` •: ... ♦ '. '.:,.�+�.y.�.�r. .• •A`. y '•:Y ,. .wl-' , fij` • ,•l�.v..:1 LJ.^'•��,.���R !, ��+fl-• f \/J�
TA 1
�k
t t�r � ♦ � 'TT 'L,Y,,, I O. s
Pip
vw
I • � 0
IL
.. t
29
is
tat
BZ,LS %. 60 21dF1 £06-d SZL-1 £96-d
ON-SITE SEWAGE INSTALLATION
FINAL INSPECTION
7
77
DATE CALLED IN:
Tam
INSTALLER:
APPLICANVOWNER:—�
CALLER.
PHONE#OF CALLER:
SWG#: c�
PARCEL NUMBER:
SUBDRUSION:
Div: Lot.
SYSTEM TYPE(CHECK ONE):
PRESSURE GRAVITY
INSPECTION SCHEDULE(CHECK ONE):
APPOINTMENT PLUG IN
AS-BUILT ON-SITE(CHECK ONE): Ll
y No
STAFF INITIALS:
APPOINTMENT
r
AS or SY NAZO 1p-
COMMENTS.
121610? 0tv by Al'T Cale
A�M At
iatuo 64 Sk MIT ASS "Mm,
ON-SITE SEWAGE INSTALLATION
STAFF INSPECTION REPORT
Yes No Comments
I. SEFnC TANK
A) >5 ft.from foundation?
B) >50 ft from wells and surface water?
C) Bldg stub-out to septic tank:clean-out if not 1-2v/v?
D) Baffles intact and clean?
E) Dividing wall intact? _
F) Risers installed for access? _
U. D-Box Leveled with water and/or speed leveler(circle)?
III. DRAIEWDr D
A) >10 ft from foundation and>5 ft from perceived properly lines?
B) >100 ft from wells and surface water?
C) >10 ft from potable water lines? ,
D) Laterals level to±1 inch&end caps present if not looped?
E) Gmvelless chambers utilized?
F) System dimensions the same as shown on the design?
G) Gravel clean,properly sized,and proper depth?
H) PREssuRE SYsrmim
1) Sand quality ASTM C-33?
2) Head height uniform and z24 inches?
3) Clean-outs and observation ports present? —
4) Mound: Side Slope 3:1?
5) Owner informed electrical connections must be made _
by owner or licensed electrician and inspected byL&1?
IV. PE2"/PUW CBnmmER
A) Screen basket or effluent filter(circle one)installed? elk TA!NL
) Riser installed for access?
C /�
C Alarm installed?
D) Pump on timer or demand(circle)? bl l
V. As-BUILTREQUmm? golMiir N
VL OTIUM C0hMffMW0BSFRVAT10M C '
NIALAr
SLOW
The undersigned has reviewed this installation and verifies these findings on behalf of MM
ounty Department of Health Services.
S[nitanan
C:\fyFi1=Td stcheckwpd
A Revised 9/261"
AS-BWU FORM w"W-SatJ I-AGO)CY Revised&28/97
Applicant's Name -r(0A15C,4,Q4— L-f 8WOLL4 Assessor's Parcel No.
PermitNumber EW& 91 Subdivision Aw"
Installer's Name
Designer's Name
r7M77=-
".0
AM
M
IUM EE
NIA Yes Prior to Completion
I SEFUC TANK
>5 ft.From foundation?
B11 stub-out to septic tank,clean-out if not l-2Ve?
Baffles intact
and clean?
Dividing wall intact?
>50 ft from wells and surface water?
Risers installed for access?
I D-Box Leveled with water and/or speed leveler(circle)?
Ill. DRAWFIRM
EJ* >10 ft from foundation and>5 ft from property lines?
* >100 ft from wells and surface water?
* >10 ft from potable water lines?
* Laterals level to±I inch&end caps present if not looped?
Gravelless chambers utilized?
F System dimensions the same as shown on the design?
Gravel clean,properly sized,and proper depth?
PRESSURE SYSTEMS
I Sand ualityASTMC-33?
2 Head=uniform and k24 inches? Actual head height, 33
3 Clean-outs and observation ports present?
4 Mound: Side Slope 30
5 Owner informed electrical connections must be made by
owner or licensed electrician and inspected by L&I?
IV. P[nvm/Prms
AI P Pump model SC- 15-0
B Screcn circle one)i
C Riser
installed or access
' A
Alarm installed?
E) Pump gallons minute 3
F Pump on time?:
Timer On L Timer Off 1) If timer.RclfroOm CI
...............
...........
... .. ........
..........
CHECKLIST
❑ Drauffield&manifold orientation TOY LAIC- I D/P 4-4V 0,r 4S W-"'-CAS'-'%C'EP3
&layout 31
El Traich/W dirm==and
mtuW distanon wAm layout 37
Q Seocipurop tank placement V 37. 5
❑ Location of buil&w. 1+3. Ti-
❑ Obwrvaltoa poit&cleanout
location.
❑ Location of wells&rroaW&S. B if S.W-
❑ q Undisturbed native sail between I
trenchm .3-7
LI NoM arrow 37,5-
37--T' DEC 0 8 W
CO)
I-PUIT ASSISTANCE CFWITC-
CAUTM.Mbar adjustmems to septic tank location mddrai Ld orismadon made ja&)7eld by the installer am gaway,aocoptabk to both the department and the
d btu�, M, a - khe health
'&� ="' *dW "'%Z laal:Aecit mthe sUyvst�*7vfa;milidfybiUZytodombIgotArthT�ap=P4nei=be shown above.
A= rh,�dadgar 9M. g ,y d,*W I= om the Wiegnnth
... ....... .............
..........
........
Installer, Check a box from Row"A7 and"B7,sign and date the certification
A. installed the deviations
g=��nth - I=4gLall d the stamped
design stamped" by e; from above.from desiJ by 'hot' E] CD design
R E) I certify t*I contacted the designer and left the system W� . -prior to final cover because the
I dill not contact the pier
pen W inspection up to 48 his Prior to cover.' designer waived the 9:Wcffa&requirement
I further certify that all information continued on this form is accurate. I understand if lion
:Xtion contained herein is not accurate,tfiere
will be just cause for immediate suspension of my installer certification. �& ,
5 0 7 -
MMI ILO
The undersigned approves this installation on behalf of Mason County De" th Services.
"-- A W&V
7