HomeMy WebLinkAboutPAR2012-00008 - PAR Application - 4/4/2012 COMMUNITY DEVELOPMENT ENVIRONMENTAL HEALTH REVIEW
Mason County Public Health Officuse only
415 N. 6th Street Permit Number: edA_'�(o
I ( !I Z Box 1666
`t-- Shelton, WA 98584 Date Received:
Shelton: (360)427-9670, Ext. 400 I �, —
i Amount Received
Belfair: (360) 275-4467 Ext 400
Elma: (360)482-5269 Ext. 400 Receipt Number Qf,
Fax (360)427-8442
Applicant Information / Type of Review
Applicant ��t 4y, /� c �th S Date ! IL O Building Permit
Mailing Address, S-r 6, y S>� lt7 D New 0 Replacement
Z�k . 9'r-r�ti yii� q c�37 I Commercial Building Permit
—7 City State Zip O New 0 Replacement
Daytime Phones36q `7a Other Phone 8,�O 5oo,5- 0 Building/Commercial Permit Revision
0 Tenant Review
E-Mail Address h Oo7� A�114 h , r Pre-Application
Parcel Information
12-Digit Parcel Number 2 3� ^SO' U 00
Site Address S-/0 1 S*R 10 6 VMI 0:, , LC/ czy
Street Number Street Name ' City
Type of Job Please submit a scaled plot plan
Describe work pui lelr'7 Ve'-1 v Cig showing all existing and proposed
building, on-site sewage system,
Number of Bedrooms N and well.
On-Site Sewage Information Water System Information
`4 On-Site Septic System 0 New 0 Existing Plumbing in structure? 0 Yes 0 No
0 Sewer Name of Sewer System If yes:
Using an existing on-site septic system will require a current Please submit a completed Water
maintenance report and a Record Drawing (Asbuilt). Documents Adequacy Form.
for both of these requirements may be on file with Mason
County Public Health. Other requirements may apply.
Applicant Signature
's�i'��� /
Date
Official use only
Departmental Review Approved Denied Notes
Water Adequacy
On-site Sewage System
Tenant Review
Revision
Revised 12/17/09
Case Activity Listing
Case #: PAR2012-00008
Parcel #: 322325001001
'Description: RENOVATION OF EXISTING MARINA BUILDING FOR OFFICE,RETAIL AND STORAGE I
POTENTIAL OF AN EASMENT INTO THE PUBLIC BOAT LAUNCH AREA, TO ALLOW FOR AN UPGRP
POTENTIAL TENANTS
Assigned
Activity Description Date I Date 2 Date 3 Hold Disp To
PARA10 Application Received 4/4/2012 None
PARB50 Public Works Review 4/4/2012 None DONE FJP
Since access is to a State Route all access issues and approvals need to be done by Washington State Department of Transportation
PARB60 Fire Marshal Review 4/4/2012 4/25/2012 None DONE
The application was none specific on the types of use's that may be occuring in the building,a code analysis is required to show compiance with the 2009 IFC.
the applicant.
All of the following items need to be addressed:
1.Fire extinguishers installed per chapter 9 of the 2009 IFC and NFPA 10.
2.A knox box per section 506 of the 2009 IFC is required to be installed.
3.The fire apparatus access road standards under ordinance 31-04 title 14 chapter 14.17 of the Mason County code.
4.Automatic fire alarm under NFPA 72 and chapter 9 of the 2009 IFC.
5.Fire sprinkler systems per chapter 9 of the 2009 IFC and NFPA 13.
6.Types of commodities,amounts stored and max.storage heights.
7.Shevling,racks and pallet storage needs to be shown,and if they are metal,plastic or wood units.
PARB20 Building Plan Review 4/4/2012 4/25/2012 None DONE
The applicant was none specific on the types of use's that would be in the building.A copy of the pre-application submittal standards was given to the applicant
with the plans showing how the proposed design complies with the current codes,all of the following needs to be addressed but not limited to
1.All structural modifications such as new windows and doors need to be engineered.
2.Set backs and rated fire wall requirements based on the distance to the property lines.
3.Wa.St.energy code compliance.
4.Full mechanical and plumbing drawings.
5.Compliance with chapter 11 of the 2009113C and ADA requirements.
6.Compliance with chapter 10 of the 2009 IBC for exiting.
7.Compliance with chapter 8 of the 2009113C for interior finishes.
8.Compliance with chapter 29 for number of required bathroom fixtures.
PARB40 Environ.Health Review 4/4/2012 4/26/2012 None DONE
Need a letter from a licensed septic designer addressing any changes in flows or waste strength. Need to designate a reserve drainfield area on the plot plan.
You will need to contact the state Department of Health regarding transient accomedations if you decide to have bunk house.
FIRE