HomeMy WebLinkAbout161 E Johns Creek Road - SWG Application / As-Built - 7/21/1975 SITE NO. w PARCEL NO. ' 30 S
DATE BASIS FOR FEE AMOU4F - - �MIBER
THURSTON-MASON HEALTH DISTRICT Q q j
DIVISION OF ENVIRONMENTAL HEALTH `�I- L5 ` �_ `P� 68q
529 WEST FOURTH 110 W.K ST P.O.BOX 746 d
PHONE 753-8073 PHONE 426-4407
OLYMPIA,WA 98501 SHELTON, WA 98584
OWNER �•
4FS NE �.S DIRECTIONS TO SITE. TOTAL
``'.11 D FEES
1D _ . I�Y0.U/Yl�
SEWAGE V, j C JOWKl
CONTRACTOR QYU ��•5 -�-(L�� �C'tt I�1 P`-' CO � �O Q
ADDRESSOR YCLY�I �G •>• V(
LOCATION
NAME OF PLAT LOT `(C yO•� �`Y
NO. SOIL TYPE
TOWNSHIP RANGE 3 SEC. 5
DEPTH TO WATER TABLE_FT.
WATER ❑PUBLIC PRIVATE PERC. TESTS: INCHES PER HOUR
SOURCE
TYPE OF I ^,e•�Iy LOT BY: DATE
BUILDING r,T`�" e-' kn��ASEMENT 16 -SIZE—X
.OF GARBAGE PRIMARY GAL SECONDARY
NO.OF NO
BEDROOMS BATHS DISPOSAL SEPTIC TANK ISI AERATION GAL.
SPACE RESFRV ED FOR DISTRIBUTION TILE TOTAL FEET
REPLACEMENTS DISTRIBUTION FIELD SQ FT.
�. NORTH - SITE PLAN AND SPECIAL STIPULATIONS: TRENCH BOTTOM AREA SQ. FEET
QUANTITY OF
I', APPROVED� APPROVED STONE CU. YD. SAND CU. YD.
FILL REQUIRED CU. YDS.
THE ELEVATION OF THE BUILDING SEWER SHALL BE SUCH THAT
THE MAXIMUM DEPTH OF THE DISTRIBUTION TILE SHALL BE BE-
TWEEN 12 INCHES AND 36 INCHES FROM FINISHED GRADE TO
TOP OF TILE UNLESS OTHERWISE STIPULATED BY THE HEALTH
M OFFICER. IF THE ELEVATION OF THE BUILDING SEWER IS TOO
LOW TO MEET THESE ELEVATIONS,A SEWAGE EJECTOR MAY BE
.; REQUIRED.
ISOLATION STANDARDS FOR PRIVATE WATER SUPPLIES:
BETWEEN WELL AND TANK OR ANY PART OF THE TILE FIELD,
100 FEET FOR SINGLE RESIDENCE, MOBILE HOMES, DUPLEXES
AND MULTIPLE DWELLINGS. NO DRAINFIELD WITHIN 100 FEET
OF ANY WELL, FRESH WATER LAKE OR STREAM)00 FEET FROM
(�yy' ANY SALT WATER BODY.
NOTE: FOOTING DRAINAGE, DOWNSPOUTS, WATER SOFTENER AND ANY
a OTHER WASTE WATER NOT DEFINED AS SEWAGE SHALL NOT BE CONNECTED
TO OR DISCHARGED INTO THE SEPTIC TANK SYSTEM OR THE SEWAGE DISPOSAL
I AREA ALL SEWAGE, INCLUDING SINK AND LAUNDRY WASTE, MUST BE
CONNECTED TO THE SEPTIC TANK.
FINAL INSPECTION REQUIRED BEFORI 1CKFILLING
OFFICE USE ONLY TO BE BACKFILLED y
AFTER INSPECTION @•�
DATE APPLICANT MUST CALL FOR INSPECTIONS LISTED BELOW rETp • ,
SITE: El APPROVED ❑ NOT APPROVED y STRAW
�
�>p,, v
BY: �� STONP0
��fj NOT OVER TILE�J
EWAGE: APPROVED ❑ APPROVED
BY: -/1 E� STONE
N T BY: UNDER TILE
WATER: ❑ APPROVED ❑APPROVEDto
CROSS SECTION OF TRENCH 0•
THURSTON-MASON HEALTH DISTRICT
5Z9 W.4-TH PHONE 753-8073 P.O. BOX 746 110 W."K" ST. PHONE J26-4407
OLYMPIA, WA 98501 SHELTON, WA 98584
RECORD OF FINAL INSPECTION OF YOUR SEWAGE DISPOSAL SYSTEM
OWNER.."� TOWNSHIP RANGE _j SEC.`
J'
THIS RECORD IS NOT A GUARANTEE OF PERFORMANCE. NAME OF LOT
A SEPTIC SYSTEM IS NOT A MUNICIPAL SEWER. HOWEVER PLAT NO.
WITH PROPER MAINTENANCE AND CAREFUL USE OF SOIL
WATER IT CAN GIVE MANY YEARS OF TROUBLE FREE SER- COMMENTS
VICE. MANY PROBLEMS WITH SEPTIC TANKS ARE CAUSED SITE AERATION FIELD X
BY FLUSHING EXCESSIVE AMOUNTS OF PAPER, CLOTH NO. SIZE
AND PLASTIC MATERIALS DOWN THE DRAIN, OR BY LARGE DEPTH TO MONTH GARBAGE Q YES
AMOUNTS OF WATER FROM LEAKY FAUCETS OR FAULTY WATER TABLE OF YEAR DISPOSAL LJ NO
FIXTURES. INSTA R
THE SEPTIC TANK ITSELF SHOULD BE CLEANED EVERY
TWO OR THREE YEARS DEPENDING ON THE HABITS OF THE SIZE
FAMILY, THE NUMBER OF FIXTURES IN THE HOUSE, AND SEPTICTANKISI
THE AMOUNT THAT A GARBAGE DISPOSAL IS USED. DRAINFIELD TOTAL FEET
CLEANING AT THE RIGHT TIME WILL AVOID THE RISK OF LENGTH
INJURING OR DESTROYING THE DRAINFIELD DUE TO TRENCH AREA , TOTAL SO. FT.
SOLIDS CARRYING OVER INTO THE DRAINFIELD. CALL THE
THURSTON-MASON HEALTH DISTRICT FOR A LIST OF LIC- TILE CORRUGATED ❑ SOLID ❑ CEMENT
ENSED SEPTIC TANK CLEANERS IN YOUR AREA. THE CLEAN- DEPTH
ER CAN SERVE YOU BEST IF YOU SHOW HIM THIS RECORD ROCK
WHEN HE COMES. CU. YDS. DEPTH INCHES
HEAVY TRUCKS OR EQUIPMENT SHOULD NEVER BE SPACE RESERVED FOR
DRIVEN OVER THE TANK OR DRAINFIELD. CONSULT THIS REPLACEMENT DISTRIBUTION FIELD: SQ. FT.
RECORD IN CASE ANY BUILDINGS, DRIVEWAYS, SWIM- NORTH.
MING POOLS, OR EXTENSIVE GRADING OR FILLING ARE
LATER CONTEMPLATED.
SHRUBS OR TREES SHOULD NOT BE PLANTED CLOSE TO
THE SEPTIC TANK AS THEY WOULD INTERFERE WITH
CLEANING OF THE TANK. THEY CAN BE PLANTED IN THE
DRAINFIELD AREA PROVIDING WILLOWS ARE NOT USED.
THE YARD GRADE IN THE DISPOSAL AREA SHOULD BE SUCH
THAT SURFACE WATER IS NOT POCKETED ON THE DRAIN- ^
FIELD. ANY SETTLING OF THE GROUND OVER THE TREN-
CHESSHOULD BE FILLED IN WITH SOIL. DO NOT EXCES- \
SIVELY WATER THE LAWN IN THE DRAINFIELD AREA.
WATER EVAPORATION FROM THE DRAINFIELD IS ABOUT
EQUAL TO ONE HALF INCH OF RAIN PER DAY. \ '
FOOTING DRAINAGE, DOWNSPOUTS AND WATER
SOFTENER RECHARGE WATER SHOULD NOT BE CONNECTED
INTO THE SEPTIC SYSTEM OR DISCHARGED INTO THE DRAIN-
FIELD AREA. - --- -----
THE TYPES OF BACTERIA NEEDED IN A SEPTIC TANK ARE
ALWAYS FOUND IN SEWAGE. THERE IS NO NEED TO ADD ._----
YEAST OR OTHER STARTERS TO A SYSTEM. THE USE OF RE-
JUVENATORS OR CHEMICALS TO CLEAN A SEPTIC TANK
HAVE NOT BEEN PROVEN TO BE BENEFICIAL AND MAY
BE HARMFUL BY FLUSHING SOLIDS OUT OF THE TANK OR
BY CHANGING THE CHARACTERISTICS OF THE SOIL. THE
NORMAL USE OF BOWL CLEANERS OR CLEANING COM-
POUNDSWILL NOT KILL THE BACTERIAL ACTION OR SLOW
DOWN THE OPERATION OF THE SEPTIC TANK. Z
�.�� BY
DATE '^`L BY
THIS IS AN IMPORTANT DOCUMENT
KEEP IT WITH DEED OR OTHER DATE CERTIFIED BY
ESSENTIAL PAPERS.
OM