July 24,2009 KA Project No.: 106-09040
Safeway,Ine.Seattle Div.Construction
Attn:Sharon Bredeson
1121- 124'Ave NE
Bellevue,WA 98005-0990
RE: Safeway Store# 1571 Remodel&Expansion-Belfair
Belfair,WA
Dear Ms.Bredeson:
in accordance with your request and authorization,the following test data are presented on the following reports,
which are enclosed:
June 10 Concrete Report No.46825—28 Day
June 11 Concrete Report No.33859—28 Day
Concrete Report No.33860—28 Day
Referenced concrete reports and compressive strength data will be mailed following 28-day tests,if applicable.
If you have any questions,or if we can be of further assistance,please do not hesitate to contact our office.
Respectfully submitted,
Penn Seely,Laboratory Manager
Peninsula Division
PS: sw
Enclosures
Cc:AtddW-t.0 w«H00-
Genaal Contractor Joe McLaughlin
General Contractor Rick Hendrickson—
Mason County
With cme m Serving The Western united States
1230 Finn HM Road NW,Suite A•1'mMo,Washington 98370•(360)598-2126•Fax:(360)598-�2127
Krazan&Asdoclates,Inc. 1230 Finn Hill Rd NW Suite A, Poulsbo, WA 98370 (360)-598-2126
Project No. 106-09040 Cyi.code P18857 Pour Date 6-10-2009 Report No. 46825 -
weather OVERCAST .jurisdiction MASON CO Permit No. 2008-00121
Project SAFEWAY BELFAIR Engineer _
Location BELFAIR Architect
Client WOODMAN contractor WOODMAN
Field Data Site Mix Reported Batoh Data
Supplier KRM Plant No. 4 cement Type I-I I
Design Actual X
Concrete X Mortar Grout Flex Beams
Prisms
Grouted Ungrouted Oar Mix No. M4060B
Cone. Air Cem.lbs. C250 560
Temp. Temp. Unit F.Ash lbs. -
Time Truck 0 Ticket# %Air Slump (F) (F) Wt.
0745 69 46491 - 6 74 61 - C.agg.lbs. C220 948
C.agg.lbs.2 C210 948
C.agg.lbs.3 -
�I Sand lbs. C200 1373
L water B282 31 gal
Piao®ment Area Admixture A340 26.1 oz
Footings Wails Columns Grade Beams Other _
Slab/Deck X Slab Pilings Other Air Ent(oycwt.) -
Grids INTERIOR SLAB 7-8/A-E.5 Water Added on Job(gals.) 18
SAMPLED @7.5/A.5
Field Test Methods
Remarks PLACED BY LINE PUMP, 15 OF 82 ds PLACED ASTM C1 M. ASTM C1 (3.Y ASTM C10 6 4 N. ASTM C173 ❑.
W/C .46 ASTM C31 ®. Other —�
inspector LOWELL DAVIS Reviewed ByR.
Laboratory Data Design Strength 4000 Date Specimens Reed. 6-11-2009
Cyl. Test Die Length Max. Comp. Tested Break Lab Test Method
Code Date Age Dim. Area Load Str.(psi) Set a By Type ASTM C39
P16657- 06/17/09 7 4X8 12.56 58385 4,650 ZL 1 ASTM C109 ❑
P16657- 07/08/09 28 4X8 12.56 69455 5,530 ZL 2 ASTM C617 0
ASTM C1231
P16657- 07/08/09 28 4X8 12.56 72520 5,770 ZL 3 ASTM C1019 0
P16657- 07/08/09 28 4X8 12.56 70990 5,650 ZL 2 Other
P16657- Compressive X
P16657- Flexural
P16657-
Test Results
P16657- X Conforming
Remarks FR#116878 Non-Conforming
Results Reviewed By VIA Date Reviewed k fsoh
Codes for Break Types: 1.Cone 2.Cone&Split 3.Cone&Shear 4.Shear 5.Columnar(Split)
Krazan &Associates, Inc. 1230 Finn Hill Rd NW Suite A, Poulsbo, WA 98370 (360)-598-2126
Project No. 106-09040 cyl.Code P16655 Pour Date 6-11-2009 Report No. 33859 -
weather CLEAR Jurisdiction MASON CO Permit No. 08-000121
Project SAFEWAY Engineer
Location BELFAIR Architect
Client WOODMAN Contractor WOODMAN
Field Data Site Mix X Reported Battoh Data
Supplier MUTUAL MATERIALS Plant No. cement Type 1-11
Design Actual X
1 Concrete Mortar Grout X Flex Beams
i Mix No. 80# BAGMIX
Prisms Grouted Ungrouted Other
Conc. Air Cem.lbs. - -
Temp. Temp. Unit F.Ash lbs. - -
Time Truck# Ticket# %Air Slump (F) (F) WL
0920 - - - FLUID 74 58 - c.egg'lbs. - -
C.agg.lbs.2
C.agg.lbs.3 - -
Sand lbs. - -
Water - -
i
PIi6lOemawd Area Admixture - -
Footings wails X Columns Grade Beams Other - -
Slab/Deck Slab Pilings Other Air Ent(oz/cwL) - -
Grids CMU WALL G/7-7.4; FIRST 4' LIFT water Added on.lob(gals.) -
Field Test Met>Iods
ASTM C106 N. ASTM C173 [3.Remarks PLACED BY BUCKET SITE MIX
ASTM C 14 W. ASTM C1 ❑.
ASTM C31 ®. Other -7
Inspector BILL UGOLINI Reviewed By
v low Laboratory Data Design strength 2000 Date Specimens Reed. 6-12-2009
Cyl. Test Dia Length Max. Comp. Tested Break Lab Test Method
Code Date Age Dim. Area Load Str.(pal) Set# By Type ASTM C39 181
P16655- 06/18/09 7 3X6 11.19 26785 2,390 AT 2 ASTM C109 13
P16655- 07/09/09 28 3X6 11.19 31165 2,790 AT 2 ASTM C617
ASTM C1231 ❑
P16655- 07/09/09 28 3X6 11.19 33320 2,980 AT 2 ASTM C1019 ❑
P16655- 07/09/09 28 3X6 11.19 32240 2,880 AT 2 Other
P16655- Compressive X
P16655- Flexural
Test Results
P16655- X Conforming
Remarks FR# 113695 Non-Conforming
Results Reviewed By W Date Reviewed
Codes for Break Types: 1.ConeF] 2.Cone&Split U
3.Cone&Shear 4.Shear S.Columnar(Split)
Kmzan &Asdociates, Inc. 1230 Finn Mill Rd NW Suite A, Poulsbo, WA 98370 (360)-5$8-2126
Project No. 106-09040 cyi.Code P16656 Pour Date 6-11-2009 Report No. 33860 -
weather CLEAR Jurisdiction MASON CO Permit No. 2008-06121
Project SAFEWAY Engineer _
Location BELFAIR Architect
Client WOODMAN contractor WOODMAN
Field Data Site Mix Reported Satoh Data
Supplier KRM Plant No. 4 cement Type 1-II
Design Actual X
Concrete X Mortar Grout Flex Beams
Prisms
Grouted Ungrouted Other Mix No. M4060B
Conc. Air Cem.lbs• 561
Temp. Temp. Unit F.Ash lbs. -
Time Truck# Ticket# %Air Slump (F) (F) WL C.agg.lbs. 3/8 948
0710 226 46538 - 5 - 58 C.agg.lbs.z 3/4 950
C.agg.lbs.3 -
Sand lbs. 1382
Water 28gal
placement Area Admixture POLY 23.6oz
Footings Wails Columns Grade Beams Other _
Slab/Deck X Slab Pilings Other Air Ent.(ozlcwt.)
Grids SLAB ON GRADE,7-8/E.5- G. Water Added on Job(gals.) 10
Field Test Methods
Remarks PLACED BY PUMP, SAMPLED @ 9 Yds TOTAL OF 27 ASTM C143 M. ASTM C138 [3.ASTM C1064 N. ASTM C17373 13.
W/C .43 ASTM C31 ® Other
inspector BILL UGOLINI Reviewed 1511*
Laboratory Data Design Strength 4000 Date Specimens Reed. 6-12-2009
Cyl. Test Dia Length Max. Comp. Tested Break Lab Test Method
Code Date Age Dim. Area Load Str.(psi) Set# By Type ASTM C39
P16656- 06/18/09 7 4X8 12.56 48880 3,890 ZL 5 ASTM C109 0
P16656- 07/09/09 ASTM C617 0
28 4X8 12.56 70510 5,610 ZL 1 ASTM C1231
P16656- 07/09/09 28 4X8 12.56 71085 5,660 ZL 2 ASTM C1019 0
P16656- 07/09/09 28 4X8 12.56 70800 5,640 ZL 1 Other
P16656- Compressive X
P16656- Flexural
P16656-
Test Results
P16656- / X Conforming
Remarks FR# 113767 Non-Conforming
Results Reviewed By Date Reviewed
Codes for Break Types:
1.Cone 2.Cone&Split 3.Cone&Shear 4.Shear 5.Columnar(Split)
7%28/200 _
( 9) Debbera Coker- David Fredrickson parcel No. 31914-12-00010 __ _ _ Page 1
From: Grace Miller
To: Debbera Coker
Date: 7/28/2009 12:52 PM
Subject: David Fredrickson parcel No. 31914-12-00010
Mother thing he asked is does he need an inspection for the grading for the road that he has finished?
I told him I did not need to do an inspection at this time.I only remember an MEP for that road but if there was also a grading
permit maybe he does need a building inspector to look at it and you could let him know??
Thank you!
+• PLAN REVIEW CHECKLIST- FOR STAFF (RESIDENTIAL AND SMALL PROJECTS)
1. In tidemark,check parcel for enforcement cases,additions,permits that have not had a final inspection,etc.
Determine relevance to project. If an enforcement case exists and applies to the project,note fees on the blue file
copy including site investigation fee,and add enforcement case number next to `violation le".
2. Review site plan. Check for slopes,the structure represented on the site plan matches builg plan layout, size
(including roof overhang,etc.),and location to adjacent structures and possible need for fire resistive
construction. If the site plan does not represent entire building notify the planner.
3. When applicable read and review the geotechnical assessment or report. Add conditions when needed
(foundation,retaining walls,etc.) If special foundation requirement specified make sure that building plans also
specify.
4. Review plans for general compliance looking for things that may require special attention. Verify use. Make
notes on a pad so that you can review at end.
5. Check braced wall compliance as follows:
a. If prescriptive: Check shear wall compliance to IRC 301.2.2.2 and Chapter 6. Det rmine seismic design
category. Shear walls should be marked on at least one set of plans. Calculate shear wall lengths and
compliance to 602.10.1 and other applicable code sections. Where foundation are greater than 50-ft in
any direction note continuous footing required.Add shear wall label.
b. If a lateral analysis is supplied verify that engineer calculations and engineers pages are stamped
including signature and expiration date. Review design calculations to verify that engineering prepared
with correct design criteria and that calculations prepared in accordance to IBC Chapter 16. In addition,
verify seismic loads(See 2305.3.10). Remember that if seismic load exceed 350 plf/490 LRFD up to
600 plf/840 LRFD ok to reduce anchor bolt spacing provided calculations verified. After 600 plf 3x
framing members required, including 3x sill plate(not 2-2x).
6. Check structural including location in county for snow load values. Review roof framing,trace point loads as you
review sections,headers,floor framing,foundation,etc.
7. Using plan review checklist review life-safety,foundation,and WSEC compliance. Add number relating to code
compliance in appropriate area. Add labels pertaining to WSECNIAQ compliance.
8. Scale structure to verify size. Make corrections in Tidemark case where applicable.
9. Enter information in Tide mark as follows:
a. Edit case(size,code,use(primary or seasonal),plumbing,mechanical etc.
b. Conditions
c. Valuation.Add valuation to the section on the blue building permit application.
d. Fees,add fee to the blue permit application
e. Activity
10. Prepare comment letter,or call applicant as needed
11. Copy plans. Prepare site and file copy.
12. Send file to case manager when permit review is complete.
11/13/2008 Jim Scholz-RE: Geo-Re ort Submittal Checklist-Saifmaj#1571 at Belfair,WA Pa e 1
From: Lu Wei Hioe<luwei.hioe@mulvannyg2.com>
To: "Jim Scholz"<JimSc@co.mason.wa.us>
CC: "Sharon Bredeson"<Sharon.Bredeson@safeway.com>, "Gregory Roybal"<Grego...
Date: 11/11/2008 11:38 AM
Subject: RE:Geo-Report Submittal Checklist-Safeway#1571 at Belfair,WA
Hi Jim,
How are you?
Although we've discussed the issues in from your email over the phone, I
thought I'll send you an email to confirm them anyway.
Associated Earth Sciences Inc is working on the submittal checklist,and
they will be getting back to you shortly.
As for the building square footage,we did revise the number such that
only the building footprint is reflected, by removing the square footage
of the mezzanine from the number we provided during the pre-submission
review, and we have also reduced the building footprint so that we are
at 50,000 SF.
Thank you for your help,and please feel free to contact me if you have
any other questions or concerns.Have a great day!
Regards,
Lu Wei Hioe I Associate
MulvannyG2 Architecture
601 SW Second Avenue Suite 1200 Portland,OR 97204
D: 503.419.4695
T: 503.223.8030
F:971.998.1615
E: luwei.hioe@mulvannyg2.com
W:www.mulvannyg2.com
Celebrating 37 years of DESIGN AT WORK
Bellevue,WA I Portland,OR I Irvine,CA I Washington, DC (Shanghai,
China
The contents of this e-mail and any attachments are confidential and the
property of MulvannyG2 Architecture.
----Original Message
-----
From:Jim Scholz[mailto:JimSc@co.mason.wa.us]
Sent:Tuesday;October 21,2008 8:40 AM
To: Lu Wei Hioe
Cc:Jim Scholz
Subject:Geo-Report Submittal Checklist
Good Morning Ms. Hioe,
Please find as attachments a Submittal checklist for both a Geo-Report
(11/13/ 8 Jim Scholz-RE: Geo-Re ort Submittal Checklist-Safeway#1571 at Belfair,WA Page 2
and a Geo-Assessment, it is my feeling from looking at the report that
was submitted as a Geo-Report that the Geo-Report Submittal checklist
would be the one you want to send on to Associated Earth Sciences Inc to
have them fill out and send directly back to me @:
Mason Co. Community Development
Planning Dept
Attn:James Scholz
P.O. Box 279
Shelton,WA 98584
1 will then use that submittal checklist to review the Geo-Report. If I
need additional information I will contact AES Inc.directly(I will
also send you out a letter)for the needed information so please have
them list a contact person.
Concerning my other question on the total square footage allowed at
50,000 sq.ft. I feel that you answered my question concerning that
issue yesterday on the phone with the mezzanine information but if you
could send me an e-mail addressing this I will have it in the file in
case any questions arise on the total square footage.Also from looking
at the remainder of the information provided in both the building permit
(7493 sq ft expansion)and the grading permit(estimated 375 cu yds)
both of these would be SEPA,exempt so SEPA is not needed. My only other
concern from idoing a preliminary review of the applications centered on
parking but that has also been satisfied by the information provided on
the site plan.At this point that is all that 1 need(Geo-Report
Submittal checklist)but I will keep you posted as more questions arise. r
Please send a return e-mail noting that you received this information
and the attachments came through okay if not I can fax them to you.
Regards,_
James Scholz
Mason County Planning