Loading...
HomeMy WebLinkAboutPAR2008-00052 Pre Submission Conference - PLN General - 8/6/2008 TO BE KEPT IN THE PARCEL, FILE PRE SUBMISSION CONFERENCE SAFE WAY EXPANSION PROJECT IN BELFAIR UGA JOANIE THOMAS/LU WEI HIOE — (AGENTS) AUGUST 6, 2008 The applicant can obtained all the information provided at the Pre App meeting by going to the Mason County Website and doing a search using online services under permit information(use the permit#PAR2008-00052)this will allow you to access the information the different departments have recorded in the case file. A compilation of these notes will be mailed to the applicants after all departments have added their pre- submission conference information. PAR2008-00052 Parcel# 1232941-00010 Site Address: 23961 NE State Rte 3,Suite A,Belfair WA Project Description: The proposed development is for the 7863 square foot expansion of the existing Safeway Store located in the General Commercial District of the Belfair UGA. ➢ Chapter 17.24.100 Information on the"GC"- General Commercial District in the Belfair UGA. ➢ Chapter 17.27 Interior Vehicular Access in the Belfair UGA. ➢ Chapter 17.28 Off-Street Parking in the Belfair UGA. ➢ Chapter 17.30 Building Design requirements in the Belfair UGA. ➢ Chapter 17.31 Landscaping in the Belfair UGA, ➢ Chapter 17.34 Signs in the Belfair UGA While some of the information I have provided you may not apply to the expansion process I wanted you to be aware of any requirements that may affect this development. ZONING: (#1232941-00010)the parcel is zoned General Commercial(GC)in the Belfair UGA. The proposed development(the expansion of the Safeway is allowed)fits with permitted allowed uses in the Belfair UGA General Commercial District but the total size of the store with the proposed expansion can't exceed 50,000 sq ft as stated at the beginning of 17.24.120. From the information that the applicant has provided,the existing area(43,625 SF) and the proposed development area(7863 SF)is a total of 51, 488 SF about 1488 SF over allowed total building size in the General Commercial District. SETBACKS and HEIGHT REQUIREMENTS: Height Restriction and Required Setbacks are located in 17.24.150 of the information on the"GC"-General Commercial District in the Belfair UGA. LANDSCAPING REQUIREMENTS: Landscaping Requirements are in Chapter 17.31. BELFAIR UGA PARKING REQUIREMENTS: According to Chapter 17.28 Of the Belfair UGA Zoning Code(Off Street Parking in the Belfair UGA) an additional 24 ,. . .. v parking spaces would be required but this may already be included in the total parking spaces now available on site. See-Off Street Parking in the Belfair UGA)requirements (minimum 3 per 1000 sq. ft.). CRITICAL AREAS: The proposed development does not appear to impact any critical areas,streams,wetlands; slopes are around 6%to 7%. Planning will not require a geo- report or assessment but the applicant will have to submit a soils report/impact analysis. SEPA: From the information provided by the applicant I cannot determine if SEPA would be required, (both the size of the proposed development 7863 sq ft and the additional parking required 24 parking spaces would be SEPA exempt)more complete information regarding the overall proposed development is needed prior to making this determination. POSSIBLE PERMITS,REVIEWS,ETC Building Permit Possible Grading Permit Possible SEPA Review The information provided above is based on details provided by applicant concerning the proposed development, additional permits or reviews may be required depending on the actually development at the time of application. Please call(James Scholz) at(360)427-9670 extension 294 if you have further questions concerning the proposed development. (12/16/2009)Terry Ryan -final Ittr.pdf Page 1 1 � KraZan & ASSOCIATES , INC . SITE DEVELOPMENT ENGINEERS October 6,2009 Project No.: 106-09040 Mr.Mark Core Mason County PO Box 186 Shelton,WA 98584 RE: Final Letter Regarding Special Testing&Inspection Permit No.:PAR2008-00052 Safeway Store#1571 Remodel&Expansion/Belfair,WA Dear Mr.Core: In accordance with our client's request and authorization, we have performed special testing and inspection services for the above referenced project.The special inspections for this project were: Special Inspection Required Performed Structural Steel: Welding Bolting Reinforced Concrete Structural Masonry Soils: Fill placement/compaction Expansion/Epoxy Anchor Bolts Seismic Resistive Systems: Suspended Ceilings Steel Storage Racks All construction activities normal &acceptable,with the exception that CMU wall grout strengths were higher than normal. To the best of our knowledge,all work and noted deficiencies have been tested and/or inspected and have been found to be in accordance with the approved plans and specifications. The engineer of record was informed of grout breaks exceeding 300% of design strength and noted as "non-conforming"in the associated lab reports. No response was received by this office. If you have any questions or if we can be of further assistance,please do not hesitate to contact our office at(360)598-2126. Respectfully submitted, KRAZAN&ASSOCIATES,INC. -' JeTftey M.Bowers Construction Services Manager Poulsbo Division cc Safeway Store,Inc.—Sharon Bredeson Woodman Construction—Joe McLaughlin Woodman Construction—Rick Hendrickson 1230 Finn Hill Road NW Suite A•Poulsbo,Washington 98370•(360)598-2126•FAX(360)598-2127 With Offices Serving the Western United States