HomeMy WebLinkAboutBLD21887 Final SFR - BLD Permit / Conditions - 8/31/1989 BUILDING PERMIT APPLICATION
MASON COUNTY
DEPARTMENT of GENERAL SERVICES
P.O. BOX 186 SHELTON, WASHINGTON 98584
427-9670 DATE ISSUED
'-s-w'0
PERMIT NO.
NAME 11 MAILADDRESS j� CITY BSTATE /3reMfP D/1 ZIP PHONE
OWNER EHrlis G- 4CR f Z Su G'S t' rl t�As i
DIRECTIONS �/ a
TO JOB SITE PR!5-t el / c hat
PARCEL LEGAL
NUMBER 233o 50 a0/� DESCR. NAven ,Lake TP, I/
NAME MAILADDRESS CITY&STATE LICENSE NO. ZIP PHONE
CONTRACTOR '9
USE OF �o
BUILDING /1 ESidel1 iQ S Sc
CLASS OF NEW ADDITION ALTERATION REPAIR MOVE REMOVE
WORK ✓
DESCRIBE n
WORK By) l v boil, Zc-'xgy
BEDROOMS DECKS ---L— CARPORT NOTICE
SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, HEATING, VENTILATING OR AIR
BATHROOMS TOTAL SQ.FT. 22^r GARAGE CONDITIONING.
NO.OF STORIES BASEMENT X ATTACHED THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT
pC COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR
TOTAL SQ.FT. DETACHED ABANDONED FOR A PERIOD OF 180 DAYS AT ANYTIME AFTER WORK IS COMMENCED.
PERMANENT SHORELINE .o—
SEASONAL
OWNERS AFFIDAVIT CONTRACTORS AFFIDAVIT
I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF THE CONTRACTORS I CERTIFY THAT I AM A CURRENTLY REGISTERED CONTRACTOR IN THE STATE OF
REGIS T ION LAW RCW 18.27,AND AM AWARE OF THE MASON COUNTY ORDINANCE WASHINGTON AND I AM AWARE OF THE ORDINANCE REQUIREMENTS REGULATING THE
REQUI MENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL WORK DONE WILL BE WORK FOR WHICH THE PERMIT IS ISSUED AND ALL WORK DONE WILL BE IN
TR
IN CJIINFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT FIRST CONFORMANCE THEREWITH.NO CHANGES SHALL BE MADE WITHOUT FIRST OBTAINING
OB INING APPROVQfAL FF�QM THE BUILDING DEPARTMENT. APPROVAL FROM THE BUILDING DEPARTMENT.
X OWNER DATE �� /y g X BY DATE
FOR OFFICE USE ONLY
APPROVED DEPARTMENT APPROVED BUILDING VALUATION
DEPARTMENT YE
S 3�,!!
YES NO IO 7'
HEALTH PUBLIC WORKS FEE
PLANNING FIRE BUILDING PERMIT
D.O.T.
BUILDING PLAN CHECK
SPECIAL CONDITIONS BUILDINGGROUP PRE-INSPECTION
SHORELINE
WOODSTOVE
tetc,, ��� � ��� PLUMBING
L' MECHANICAL
STATE BUILDING FEE 6
STATE SURCHARGE
APPLICATION CEPTED BY PLANS CF}�CK BY APPR:�W
FORSUANCE PERMIT VALIDATION TOTAL
/�r.,-� ' IBY CASH CK MO
PLUMBING & MECHANICAL PERMIT APPLICATION
MASON COUNTY
DEPARTMENT of GENERAL SERVICES
P.O. BOX 186 SHELTON, WASHINGTON 98584
427-9670 DATE ISSUED
PERMIT NO.
OWNER NAME MAIL ADDRESS r CITY&STATE pre'v%er top ZIP PHONE
DIRECTIONS pK�
TO JOB SITE r ' S Oo e
Approx
Aquen tgl'c i v
LEGAL 1 1 3-2 96 .Sc'gbee q$3f�
DESCR. E�-qr/IS G u Hw,v IV,Lc-, 13 remer i w LL U '19"C)
CONTRACTOR NAME MAILADDRESS CITY&STATE LICENSE NO. ZIP PHONE
S 0
USE OF
BUILDING ifes i (sjfv--�v
PLUMBING FIXTURES MECHANICAL FIXTURES
NO. 2.00 PER FIXTURE OR TRAP FEE NO. TYPE OF FIXTURE FEE
! WATER CLOSETS G z+ FORCED-AIR/GRAVITY TYPE FURNACE 6.00
BASINS FLOOR/SUSPENDED FURNACE 6.00
BATH TUBS BOILER/COMPRESSOR 6.00
SHOWERS e1 REPAIR/ALTERATION 6.00
WATER HEATERS r c REFRIGERATION COMPRESSOR SYSTEM 6.00
AUTO.WASHER e,r AIR HANDLING UNITS 7.50
SINKS �, �, HEAT-PUMPS 6.00
FLOOR DRAINS EACH GAS PIPING SYS.2.00 PER OUTLET
DRINKING FOUNTAINS VENT.FAN SYS.3.00 PER UNIT
LAUNDRY TRAYS WOOD STOVES 5.00
CONNECTTO CITY SEWER WOOD FURNACE 5.00
DISHWASHER
DISPOSAL
URINALS
PERMIT BASIC FEE 3.00 PERMIT BASIC FEE 10.00
TOTAL 115ele TOTAL
SPECIAL CONDITIONS: NOTICE: THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION
AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS,OR IF CONSTRUCTION OR WORK IS
SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS
COMMENCED.
OWNERS AFFIDAVIT: I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF CONTRACTORS AFFIDAVIT: I CERTIFY THAT I AM A CURRENTLY REGISTERED
THE CONTRACT OR REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON CONTRACTOR IN THE STATE OF WASHINGTON AND I AM AWARE OF THE ORDINANCE
COUNTY ORDINANCE REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL REQUIREMENTS REGULATING THE WORK FOR WHICH THIS PERMIT IS ISSUED AND ALL
WORK DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WORK DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE
WITHOUT FIRST BTAININ APPR L FROM THE BUILDING DEPARTMENT. WITHOUT FIRST OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT.
X OWNER DATE / X BY DATE
FOR OFFICE USE ONLY
APPLICATION ACCEPTED BY PLANS CHECK BY BUILDING GROUP APPROVED FOR ISSUANCE PERMIT VALIDATION
BY I CASH CK MO
MASON COUNTY
DEPARTMENT of GENERAL SERVICES
Courthouse Annex I N. Fourth & W. Cedar
P.O. Box 186 Shelton, Washington 98584
(206) 427-9670
building environmental health maintenance landfill parks&recreation fair/convention center planning sewer&water
April 27, 1988
Earlis Sullivan
3290 Seabeck Highway NW
Bremerton, WA 98312
Dear Ms. Sullivan:
Yesterday I conducted a site inspection of the proposed location for
your residence. The residence location is acceptable but while on site I
noticed that you have a new dock and float.
A Building Permit is required for the dock. Please complete the
enclosed forms for the dock and return as soon as possible.
Thank you,
Patti Miller—Crowley, Planner
DEPT OF GENERAL SERVICES
PMC/jw
Encl.
ARCHITECTS KLAASSEN/DALKE, AIA
P. 0. BOX 1306 / 203 RAILROAD AVE.
SHELTON, WASHINGTON 98584
(206) 426-2550
DATE April 21, 1988
NAME Earlest and Renae Sullivan PH. 470-8077
ADDRESS 3290 Seabeck Highway NW, Bremerton, WA 98312
PROJECT ADDRESS
H E A T L 0 S S C A L C U L A T I O N S
MAIN FLOOR AREA 567 S .F.
SECOND FLOOR/LOFT AREA N/A S . F.
BASEMENT FLOOR AREA ( if applicable) 480 S .F.
MAIN FLOOR VOLUME 5 , 070 C .F.
SECOND FLOOR VOLUME N/A C . F.
BASEMENT FLOOR VOLUME 3L_720 C . F.
WALL AREAS : MAIN FLOOR 888— S •F •
SECOND FLOOR N/A S . F.
BASEMENT 837 S . F.
WINDOW AREAS : MAIN FLOOR 268 S .F.
(Total 19 .4%) SECOND FLOOR N/A S . F.
BASEMENT - 67_ S . F.
ROOF AREAS 624 S .F.
DOOR AREAS 37 S .F.
INFILTRATION (Number of Air Changes Per Hour) 1 . 5
INSIDE TEMPERATURE 70OF
OUTSIDE TEMPERATURE 240F
Page 2 - HEAT LOSS CALCULATIONS
1 . HEAT LOSS THROUGH AIR LEAKS
01 = . 018 x V x l6T x ACH
(constant) (volume) (temp. diff . ) (air changes)
= .018 x 8, 790 x 46 x 1 . 5
= 10, 917 BTUs/hour
2 . HEAT LOSS THROUGH WALLS
WALL COMPONENTS - MAIN FLOOR
Qc = A x AT Inside Air Film 0 . 68
R Gypsum Board 0 .45
Insulation 13 . 00
888 x 46 Exterior Sheathing 5 .40
20. 49 Exterior Siding 0 . 79
Outside Air Film —2�
= 1, 994 BTUs/hour TOTAL 20 .49
WALL COMPONENTS - SECOND FLOOR
Qc = A x 4T Inside Air Film
R Gypsum Board _^
Insulation
_ x 46 Exterior Sheathing
Exterior Siding
Outside Air Film _
= BTUs/hour TOTAL N/A
WALL COMPONENTS - BASEMENT
Qc = A x A�N T Inside Air Film 0 . 68
R Gypsum Board 0 .45
Insulation 13 . 00
= 837 x 46 Exterior Sheathing 5 . 40
20. 49 Exterior Siding 0 . 79
Outside Air Film 0- 17
= 1, 879 BTUs/hour TOTAL 20 .49
3 . HEAT LOSS THROUGH ROOF/CEILING
ROOF/CEILING COMPONENTS
Qc = A x AT Inside Air Film 0 . 68
R Gypsum Board 0 . 56
Insulation 33 . 00
= 624 x 46 Exterior Sheathing 0 . 68
Roofing 0 .44
40. 53 Outside Air Film 0 . 17
= 708 BTUs/hour TOTAL 40 . 53
Page 3 - HEAT LOSS CALCULATIONS
4 . HEAT LOSS THROUGH FLOOR
FLOOR COMPONENTS
Qc = A x AT Inside Air Film 0 . 68
R Floor Covering 0 . 05
Underlayment . 1. 05
= 567 x 46 Sub-Floor -0-
20. 95 Insulation 19 . 00
Outside Air Film 0. 17
1, 245 BTUs/hour TOTAL 20 . 95
5 . HEAT LOSS THROUGH GLASS
GLASS COMPONENTS
Qc = A x j4 T Insulated Glass (double) ,
R Class 60 with electric
resistance . 1 . 82
335 x 46 TOTAL 1�2--
1. 82
8 ,467 BTUs/hour
6 . HEAT LOSS THROUGH EXTERIOR DOORS
DOOR COMPONENTS
Qc = A x4iT
R Solid Core Doors 2 . 78 _
TOTAL 2 . 78
37 �5 46
2. 78
612 BTUs/hour
TOTAL ESTIMATED HEAT LOSS 25 ,822 BTUs/hour
N/A = Not Applicable
All above based on drawings received April 19 , 1988 ,
and components shown above . If all above requirements are met ,
this building will conform to Chapter 4 of the State Energy Code .
Should you have any questions , please let me know.
Sincerely,
l / ;
Darold E . Dalke, AIA
Shorelines: Plumbing: e�-,
Setback:r/<' NL-chanical:
Special Interior:
Conditions: FINAL: 7
Mobile acne:
Smoke Detector:
Remarks: Ales 7 c��t✓—�tJc
0o ing• .ems -UN el
Setback:
Foundation
Walls: N ?r icy ��'c t Pay
Framing: �,r
Fireplace:
Wood Stove:
Togh.2 rtS >Zo
TYPE ---E=,�DENCE
Permit Nb. 1 R R 7 No. Floors , Sq Ft9
Owner Ri7LLTVAN, Earlis & CharA91 479-8077Date 5-2-88
Address 3290 Seabeck Hwy NW Bremerton Zip 9R312
Contractor SP1f
Address Zip
Iagal Description
Direction to project site =act Ralfair Gtata Par1r - turn r
right RP fai r-Tahiiz a PH - 3 rnx F, Myles - 1-jjgn I Qft
P Ing M- anic Sewer Wood Stove
Fireplace Deck Garage Carport
Basement Loft Other