Loading...
HomeMy WebLinkAboutBLD2007-00478 Final MFG Home - BLD Permit / Conditions - 7/21/2008 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 o Shelton, WA 98584 1 RESIDENTIAL BUILDING PERMIT BLD2007-00478 OWNER: LEONARD SAYERS RECEIVED: 3/22/2007 CONTRACTOR: MODERN LIVING LICENSE: MODERLL972DO EXP:4/14/2009 ISSUED: 5/4/2007 SITE ADDRESS: 121 NE MOUNTAIN VIEW PL TAHUYA EXPIRES: 11/4/2007 PARCEL NUMBER: 223315200070 LEGAL DESCRIPTION: COLLINS LAKE #3 TR 70 PROJECT DESCRIPTION: DIRECTIONS TO SITE: Replace Manufatured Home (2 BEDROOM WITH DEN) General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: 2 Type of Constr.: Type of Use: MH Insp. Area: No.of Bathrooms: 2 Occ. Group: R-3 Lot Size: Deck: Type of Work: Fire Dist.: 2 No. of Stories: Occ. Load: Building: Valuation: Building Height: Occ. Status: Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make:Liberty Length: 40 Ft. Front: E 125.0 Ft. Shoreline: Ft. Water Body: Maggie Lake SEPA?: No Model:Anniversar Width: 26 Ft. Rear: 1N 231.0 Ft. Slope: Ft. Shoreline Desi Side 1: N 45.0 Ft. 9•: Not Applicable Year:2007 Serial No.: Side 2: S 10.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty, Type By Date Amount Receipt Mobile Home Submittal Fee KKK 3/22/2007 $235.00 S22007000 Planning Review Fee KKK 3/22/2007 $170.00 S22007000 Building State Fee LDK 3/29/2007 $4.50 522007000 Mobile Home Issuance Fee LDK 3/29/2007 $235.00 S22007000 EH Plan Review CMH 5/4/2007 $75.00 S22007000 Total $719.50 BLD2007-00478 Please referto the following pages for conditions of this permit. 1 of 5 CASE NOTES FOR BLD2007-00478 CONDITIONS FOR BLD2007-00478 1) This parcel is located in a smoke management zone. Please contact a fire warden at(360)427-9670 ext. 459 for further information. X 2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X ' 3) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X 4) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X 5) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads,"all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspections. X 6) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X 7) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved"site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X BLD2007-00478 Please refer to the following pages for conditions of this perrnit. 2 of 5 8)• Any retailer, manufacturer or contractor who installs a manufactured home warrants that the manufactured home is installed in accordance with the State Installation code, chapter 296-150M WAC. All installers hired to do installation work shall be certified manufactured home installers and shall be present to supervise the installation of all on-site work. An Installer Tag shall be posted on site giving the certification number and signature of the certified installer responsible for each major part of the installation. RCW43-63B.090 An approved Installer cerification tag shall be placed on the end of the manufactured home directly above or below the HUD certification tag or temporarily located in plain site within three of the home's front entry. There shall be one certification tag for each certified installer accounting for the work that each installer performed or installed. certification number and signature of the certified installer responsible for each major part of the installation. WAC365-210 X ' .. 9) If you are installing a manufacturing home and no longer have the installation manual for the home, you must use the instructions of the American National Standards Institute (ANSI).To order the ANSI instructions you may either get an order form from the Mason County Building Department or you can contact the Offfice of Manufacturing Housing (360) 725-2800. 10) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X 11) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X 12) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X 13) REQUIRED INSPECTIONS (Footing Inspection-prior to pour, Set-up Inspection-prior to skirting, Final Inspection-prior to occupancy). I hereby assume all responsibility for the scheduling of my required inspections. If the required inspections are not requested, inspected and signed off(approved) by the inspector in the prescribed order, I understand that reinspection fees and an hourly investigation fee pursuant to the current fees adopted by the Mason County Building Dept., and will be assessed in addition to my original permit fees to resolve any questionable practices or problems that have been discovered. I further understand that this investigation will be scheduled as time allows. Until resolution of any/all problems no occupancy(Final Inspection)will be granted for the residence. OWNER/CONTRACTOR(indicate which) Signature X 14) Applicant has indicated this is a replacement unit. Prior to Mason County allowing any occupnacy of the new proposed unit, the existing unit which is on-site and is being replaced MUST be removed from the parcel. X ' 15) This permit is for the placement and installation of the manufactured home only and does not imply approval or review for any other items indidcated on the plot plan. X BLD2007-00478 Please referto the following pages for conditions of this permit. 3 of 5 16) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project., X 17) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. X 18) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. X 19) The installation permit shall be displayed in clear view of the site access road. The approved site plan and other applicable instructions, including installation instructions, shall be available in this location OR placed in the location specified by WAC 296-150M-655. Support configuration shall be clearly marked in the installation instructions. 20) All property lines shall be clearly identified at the time of foundation inspection. X , 21) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X 22) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X 23) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X x- 24) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X BLD2007-00478 Please referto the following pages for conditions of this permit. 4 of 5 25) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. X 26) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 27) The existing cabin/dwelling on property must be removed prior to construction of propsed new single-family residence X 28) Water quality is not to be degraded to the detriment of the aquatic environment as a result of this project. X 29) Prior to final approval, all upland areas disturbed or newly created by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 30) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied.Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and infection. OWNERORAGENT: �� r A'-r' DATE: BLD2007-00478 Please refer to the following pages for conditions of this permit. 5 of 5 W o CONCRETE MECHANICAL MANUFACTURED HOME ,Ny Footings!Setb cks Date By Ribbons . M Gas Piping C) Interior Date y Interior-Date By Date S Z y v gy�I Cl) 0 4 Exterior Date 8Y Exterior-Date By - Co Set-up r Point load!isolated Footings INSULATION Gate /�C. By M Q BG!SLAB INSULATION Z Date By Data By FIRE DEPARTMENT y Foundation Wails Floors Date By Date BY Data By DECKS FRAMING Walla Date By Date By Data By PROPANE TANKS PLUMBING vault Data By Dow By —._.. ---------_ OTHER Groundwork Attic Type_ Date By Date _ By Date By Mw.v DRYWALL Type: Int.Brace Wail Date By 03 Dale By Date By FINAL INSPECTION Water Line Fire Seperation Date By Date By Date 2 2V--CO B� / p Pass or Request Inspect. c Type of Insp. Fail Date Date Done By Comments y m O b o.Ss S 23 D S Z 0� Go , rem C.e.r.{tN r--�Ve_ So-+ pp 0 -/S•O? �.,( Lam. -?,off' (- 7-A, . a _ f r—EE //,w ,2--/ �9ixv CiyoJ o 0 c,in cn O.✓ f c�4G�F0 T Jed /.,� � sc/t,G,c2xG G�v�.o cigcL / 0 Mason County Dept. of Community Development Mason County Bldg. 3 426 W. Cedar P.O. Box 186 (360) 427-9670 Local (360) 482-5269 Elma Shelton, WA 98584 (360) 275-4467 Belfair Notice to Obtain Final Inspection December 24, 2007 LEONARD SAYERS P. O. BOX 983 BELFAIR WA 98528 Case No.: BLD2007-00478 Parcel No.: 223315200070 Protect Description: Replace Manufatured Home (2 BEDROOM WITH DEN) The Mason County Department of Community Development is currently reviewing all permits that are expired and have not been approved for occupancy and use. Pursuant to Mason County Code, Title 14 Building and Construction, a permit and final inspection for this type of activity is required under the 2006 International Building Code or the code your permit was issued and your property is currently in violation status of occupancy and use. Please contact our office to make the necessary arrangements 21 days from the date of this letter. Failure to contact our office to make the necessary scheduled inspections will result in enforcement actions. To bring your site into compliance, you must schedule an inspection. One (1) $64.00 site investigation fee will need to be paid prior to inspection along with any outstanding fees currently due on your building permit. For every inspection required after that, you will be charged $64.00 again, per inspection until final inspection and conditions are met. To schedule an inspection, please call (360) 427-9670 ext. 262. If you should have any questions regarding this notification, please contact me at (360) 427-9670 ext 359. Sincerely, Ar-_ Terry Ryan Mason County Department of Community Development Cc: Property File December 24, 2007 BLD2007-00478 MASON COUNTY PERMIT NO. Lf BUILDING PERMIT APPLICATION Oc _ 426 W. Cedar•P.O. Box 186, Shelton, WA 98584 Shelton (360)427-9670 Belfair(360) 275-4467•Elma (360) 482-5269 � On the web www.co.mason.wa.us [APPLICANT INFORMATION CONTRACTOR INFORMAT ON .wnerCompany Name • v r 1ailin Add essMailin Address.2�1-(��R 0/�ity ' ` State G din s!'.,.ae �' � City �-ref��R._ State ,+vvuc y �Zt 13��Other Ph. Phone '-q IL ZQO L "=, Other Ph. Lien/Title Holder_ Contractor Reg.# M t)U t? 1 t� �Exp.�, y l E mail address E Mail Address Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC/WATER SYSTEM INFORMATION -Connect to New Septi Existing Septi t� Connect to Water System � c_Name of Water System a I ) Well Water System Name of Water System 11 PARCEL INFORMATION-12 Digit Parcel No / Legal Description.,Cc, y$ 3­0Fire District Site Address(Please include street name,street number and city) / — Directions to site - Will timber be cut and,sold in parcel preparation?Yes No Is property within 200,of Saltwater Lake River/Creek Wetland Serssonal Runoff Stream oPond Slopes or Bluffs � 15/a Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No TYPE OF JOB -Ne'w Add Alt Repair Other Use of Buildin PRIMARY RESIDENCE E]9 ❑ Describe Work No. of Bedrooms No. of Bathrooms Square Footage- 1st Floor 3rd Floor Basement Deck 2nd Floor Covered Deck Other Sq.ft. Garage Affached Detached Carport Attached Detached MANUFACr�URED(HOME INFORMATJQN -Make Model 1- vL Length Width: `�`Serial No. L-10 No.o Years Type of Heat-�CG�2; Purchase Price$ '/N No.of Bathrooms_ Installer Name � 11,E h Vlp ✓ t e o OWNER/BUILDER Adw-wledges submission of inaccurate information may result in a stop work order or such is by signature below.I declare that I am the owner,owners I�representative wit revocation• enowledgement of permit and to do the work a s proposed in the ,or the contractor.I further declare that I am entitled to receive this required from any a work art holder a application.I declare that I have obtained the permission from all the necessary parties.If permission is �other party in interest regarding this application or the work proposed in the application,I have obtained apply for this permission from them to permit and conduct the work proposed. The owner or agent on owners behaff, provided is accurate and grants employees of Mason County access to the above described o represents a that the information PROOF O•F O, N1INUATION OF W RK IS BY MEANS OF A PROGRESS INSPECTION.property and structure for review and inspection. X .3laaly Owner Owners Flo resentative/ ntra indicate which one Date FOR OFFICIOUS E BEYOND POINT Accepted b DEPARTMENTAL RIEVIEW APPROVED DENIED p y Date Building Department NOTES Planning Department 2 ( k Environmental Health Cepartment Public Works Department Fire Marshal L FEES Buildin Permit Fee Site Inspection Plan Review Fee EH Review Fee Plumbing&Base Fee PlanningReview Fee Mechanical&Base fee Other Wood/Gas/Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal Valuation$ TOTAL FEES