HVAC PLAN NOTES
DANIEL SULLIVAN
EQUIPMENT&DIFFUSER SCHEDULE President
{ A/C- 1 Carrier 38CKC060-3 split system cooling unit-5 ton
Cooling 54,500 BTUH's,208V/ 10 IRA 169 M.O.C.P. 60A
F- 1 Carrier 58RAV115-1-20 gas furnace with DX coil
1880 CFM, 80%A.F.U.E. (360)405-0723
950 West Hills Blvd. 1-800-443-0723
CD- 1 Shoemaker MA0700 2'x2'4-way T-Bar supply diffuser. Bremerton,WA 98312 FAX(360)405-0831
CFM as noted.
RAG- 1 Shoemaker 105P 2'x2'T-Bar return grille
NOTES 1)Flex duct max. length 10'
2)Insulate all exposed duct to R-8
3)Vent all exhaust fans to roof
4)All locations for units &diffusers are approximate
5)Drain pan to be installed under F- 1
6)0-25%manual dampers for outside air provided through
F- 1
AIR CONDITIONING NOTES
1. ALL WORK AND MATERIALS SHALL PERFORMED AND INSTALLED IN COMPLIANCE
WITH THE FOLLOWING CODES AS AMENDED AND ADOPTED BY THE INSPECTION
AUTHORITY. NOTHING IN THESE PUNS IS TO BE CONSTRUED TO PERMIT WORK
NOT CONFORMING TO THESE CODES OR OTHERS APPLICABLE TO THIS PROJECT.
A. WASHINGTON STATE BUILDING CODE
B. UNIFORM MECHANICAL CODE
C. UNIFORM PLUMBING CODE
D, NATIONAL ELECTRICAL CODE
E. WASHINGTON STATE ENERGY CODE
F. NATIONAL FIRE PROTECTION ASSOCIATION
G. OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA)
2. DRAWINGS INDICATE DIAGRAMMATICALLY THE ARRANGEMENT OF PRINCIPAL
APPARATUS, PIPING, DUCTWORK, AND OTHER MATERIALS. FOLLOW DRA'MNGS AS
CLOSELY AS POSSIBLE IN ORDER TO ACHIEVE A NEAT ARRANGEMENT OF
PIPING, DUCTWORK, AND EQUIPMENT WHILE STILL OVERCOMING OBSTRUCTIONS.
3. DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH THE
LATEST EDITION OF THE SMACNA LPOC STANDARDS.
4. ALL DUCT JOINTS SHALL BE MADE WITH MASTIC SEALANT. SHEET METAL SCREWS,
AND TAPED AIR TIGHT WITH DUCT TAPE, MINIMUM 2 1/2" IMDTH.
5. ALL BRANCH DUCTS SHALL HAVE BALANCING DAMPERS WITH ACCESSIBLE, LOCKING
TrPE QUADRANT.
6. ALL VISIBLE SURFACES BEHIND GRIIIE FACES SHALL BE PAINTED FLAT BLACK.
7. SHEET METAL DUCTS SHALL BE INSULATED EXTERNALLY WITH .75 LB/CU.FT.. 1 1/2"
THICK FIBERGLASS BLANKET, UNFACED, EXCEPT THOSE DUCTS INTERNALLY LINED.
ALL DUCTS NOTED OR SHOWN "ACOUSTICALLY LINED" SHALL BE
INTERNALLY INSULATED WITH BLACK MAT FACED FIBERGLASS 1 1/2' THICK, 1 1/2
LB/CU. FT. DENSITY. DUCT DIMENSIONS ARE NET INSIDE.
8. INSULATED FLEXIBLE DUCTWORK: CONTINUOUS INTERNAL LINER BONDED TO
GALVANIZED STEEL WIRE HELIX. 1 LB/CU.FT. FIBERGLASS INSULATION, 1" THICK
SEAMLESS VAPOR BARRIER JACKET. EACH LENGTH SHALL HAVE A FACTORY
INSTALLED METAL SLEEVE AT EACH END. DUCT SHALL COMPLY WITH UL-181 AND
NFPA 90A AND 90B. MAXIMUM LENGTH 7 FT., SINGLE PIECE AT RUNOUTS TO AIR
TERMINALS. GENFLEX, LAMBORN.
9. ALL INSULATION SHALL HAVE A MAXIMUM FUEL CONTRIBUTED OF 50, MAXIMUM
SMOKE DEVELOPMENT OF 50, AND MAXIMUM FLAME SPREAD OF 25.
10. COORDINATE EXACT LOCATION OF AIR TERMINALS WITH THE ARCHITECTURAL
REFLECTED CEILING PLAN AND STRUCTURAL FRAMING.
I
CURVES & COFFEE SHOP '
M
BELLTOWN SQUARE BELFAIR WA.
I
E
1
E i.
_1
O4J4nl:1 t,G,
j 8• IN E)(Ft SIN
N MECH. ROOM TOUEr/FANS ` CiF
:t DRESSINU RESS NO-RM
513'x5' 513'x5'2'
o BENCH 2668 BENCH 3068SCfC68
j SC
4068
SC
j 20'
limoo" wwqpwupw�
39'- w
i
CURVES /o"o 7 YP. o ij N
.h•C�
ER4c1t51 Tv�✓�/ � �
Iq
in (aV !I s DESK z
EXISTING CONC. FLOOR
FINISH FLOOR TO TENANT SPEC. <6 � 1
4,e
"T-BAR' CEILING
WC 4'
3068 HC TOILET ` t°STORAGE
I HC o FI.A C>.�� 7'-7~ I
-f -w►- EXH.
� FAN IN
INTERIOR WAIL. ,>° �1 .~_.�`
lYP ,� .,06$
Z 2x4 STy05 16" O.C. _ 1`" 30688 HC
SOUNDPROOFING IF REQ. ti
5/8- GYP r HCIn
c
Ar
O v
1 WI1'-5"+- .
Al1GN WALL W ND. 11UL1JON f� !y 4'-2" N d •�"
MOI F REP SIN
Q. p�p� �, `�� 6068 MEETING ROOM
8 -4" J DBL
r-
STORAGE
In .
t 6 -4w FRENC
3'PKT
DOOR
to •f►' 12'-1"
j �� EXISTIN �ci
$ ;•� 6060 N o-
�. 6#4" GLASS EXISTING EX. WALL
c ` DOORS
{ 2'1' WIDE COUNTER � 20'
8'
COFFEE OP
.a-r+►- - a- w.F- a
i
00
FLOOR PLAN
20' SCALE 3/16"= 1 FT.
2000 SQ . FT.
DANIEL SULLIVAN
President
CURVES & COFFEE SHOP (360)405 0723
950 West Hills Blvd. 1-800-443-0723
BE L LT O W N S Q U A R E B E LFAI R WA. Bremerton,WA 98312 FAX(360)405-0831
I