Loading...
HomeMy WebLinkAboutWellhouse, Control Bldg Concrete and Field Report - BLD Engineering / Geo-tech Reports - 4/18/2002 KraZan & ASSOCIATES., INC . GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION April 18,2002 KA Project No.: 106-02008 Belfair Water District Mr.Jerry Hukill P.O. Box 563 Belfair, WA 98528 RE: Belfair Wellhouse,Control Building/Belfair,WA Dear Mr.Hukill: In accordance with your request and authorization,the following test data are presented on the following reports, which are enclosed: February 15 Concrete Report No. 2630 March 3 Field Report No. 5932 Referenced concrete reports and compressive strength data will be mailed following 28-day tests,if applicable. If you have any questions,or if we can be of further assistance,please do not hesitate to contact our office. Respectfully submitted, l.� Penn Seely,Laboratory Manager Peninsula Division PS Jm Enclosures Cc: Mason Cty.Building Dept.—Mr.Lary Waters � L � c7 � APR232M2 �• ,� COMMUNITY DEIIELQPIVIEN� With Eleven Offices Serving The Western United States 20714 State Hwy. 305 NE,Suite 3C 9 Poulsbo,Washington 98370•(360)598-2126 9 Fax: (360)598-2127 Krazan &Associates, Inc. 20714 State Hwy. 305 N.E. Suite 3C, Poulsbo, WA 98370.(360)-598-2126 Project No. 106-02008 Cyl.Code P3005 Pour Date 2-15-2002 Report No. 2630 Weather CLEAR Jurisdiction MASON COUNTY Permit No. Project BELFAIR WATER DISTRICT Engineer Location HWY 3, NEAR BELFAIR, WA Architect Client Contractor MASONRY ASSOC. Field Data Site Mix Reported Batch Data supplier KITSAP READY MIX Plant No. Cement Type TILBURY I Concrete Mortar Grout X Flex Beams Design Actual X Prisms Grouted Ungrouted Other Mix No. 570A30 Conc. Air cam.lbs. 661 Temp. Temp. Unit F.Ash lbs. - Time Truck# Ticket# %Air Slump (F) (F) Wt. 8:20 223 41213 - FLUID 55 35 - C.agg.lbs. - C.agg.lbs.2 SAND 995 C.agg.lbs.3 1062 Sand lbs. 1083 Placement Area water 19.4 gal. Admixture POLY 40.1 oz. � Footings Walls X Columns Grade Beams Other - Slab/Deck Slab Pilings Other Air Ent.(oz/cwt.) 7.1 oz. Grids CONTROL HOUSE WALLS TO FIRST BOND BEAM. REINFORCEMENT PER NOTES/DETAILS, SHEET 3. Water Added on Job(gals.) 10 Remarks PLACED BY PUMP, CONSOLIDATED BY Items Inspected VIBRATION. X Conforming 3.25 CYDS PLACED. W/C = 0.46. Inspector P. SEELY Reviewed By Z Non-Conforming Laboratory Data Design Strength 2000 Date Specimens Rec'd. 18 FEB 02 Cyi. Test Dia Length Max. Comp. Tested Break Test Method Code Date Age Dim. Area Load Str.(psi) Set# By Type P3005-1 2/22/2002 7 4X4X8 17.64 43520 2,470 JLM 1 ASTM C39 P3005-2 3/15/2002 28 4X4X8 14.88 40810 2,740 TR 2 C-1231 P3005-3 3/15/2002 28 4X4X8 15.50 43620 2,810 TR 2 Other C1019 P3005-4 P3005-5 Compressive X P3005-6 Flexural P3005-7 P3005-8 Test Results X Conforming Remarks REFERENCE: FR# 5131 Non-Conforming Results Reviewed By Date Reviewed Codes for Break Types: 1.ConeF] 2.Cone&Split 3. Cone&Shear 4.Shear 5.Columnar(Split) I i & Associates , Inc . FIELD REPORT NO: 5932 KraZan GEOTECHNICAL ENGINEERING - ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING AND INSPECTION • NATURAL RESOURCES I WETLANDS DATE:���1,1 CONTRACTOR: ,1 -,I✓er { Ans PROJECT#: '0 0 CiFi$ JURISDICTION: /}'j/Q-S.4o(/ �yuy►_7� PROJECT: & L PERMIT#: CLIENT. k'. INSPECTOR: �-fFr— KRAZAN PROJECT MANAGER: ? WEATHER:.. G�� TEMP: S��;n r� 13 l�ls 1U P-1 S � . ,Fl-,�1� �(' Ur�G -h� — 1 Cis? a4 4r Ica data Ayo AT p -,t/. a4 Lam, !1'-a 945i:bQT 6OmAIMSsE-L /G&c.aZ4,1 6)- r-e— i To the best of my knowledge,the above WAS NOT performed in accordance with the approved plans,specifications,and regulatory requirements. Super!ntendent/Representative: Technician: xvi 215 West Dakota Avenue Clovis,CA 93612 (559)348-2200 01-15th St.NW Suite 106 Auburn, WA 98002 (253)939-2500 4231 Foster Ave. Bakersfield,CA 93308 (661)633-2200 20714 State Hwy 305 NE Suite 3C Poulsbo,WA 98370 (360)598-2126 1025 Lone Palm Ave.#8G Modesto,CA 95351 (209)572-2200 19501 144th Ave.NE#F-300 Woodinville,WA 98072 (425)485-5519 545 Parrott St. San Jose,CA 95112 (408)271-2200 11913 NE 103rd Ave. Vancouver,WA 98662 (360)254-3200 123 Commerce Circle Sacramento,CA 95815 (916)564-2200