Loading...
HomeMy WebLinkAboutBLD2005-01107 - BLD Application - 7/5/2005 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, WA 98584 (Its I (/ ' RESIDENTIAL BUILDING PERMIT BLD2005-01107 OWNER: RAYMOND BEDFORD RECEIVED: 7/5/2005 CONTRACTOR: STANBROOKE CUSTOM HOMES 253-841-3900 253-841-3901 LICENSE: STANBCH983PP ISSUED: 8/2/2005 SITE ADDRESS: 251E GREAT BEND DR UNION EXPIRES: 10/27/2006 PARCEL NUMBER: 322314290124 LEGAL DESCRIPTION: TR 12-D OF GOVT LOT 2 PCL 1 OF BLA#01-93 AF#1742561 PROJECT DESCRIPTION: DIRECTIONS TO SITE: New SFR N. Hwy 101 to right on Hwy 106 to right on E. Main, left on 3rd, 3rd becomes E. Alder. General Information Construction&Occupancy Information Square Footage Information o.of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp.Area: No.of Bathrooms: 2 Occ. Group: R3U Lot Size: Deck: Type of Work: NEW Fire Dist.: No.of Stories: 1 Occ. Load: Building:1,738 Garage-Attached 748 Valuation: Building Height: Occ. Status: Primary Basement: cov porch 138 Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: E 60.0 Ft. Shoreline: 15.0 Ft• Water Body: Rear: W 400.0 Ft. Slope: Ft. SEPA?: Model: Width: Ft. Shoreline Desig.: Side 1: S 33.0 Ft. Year: Serial No.: Side 2: N 10.0 Ft. Comp. Plan Desig.: Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Plan Check Fee KKK 7/5/2005 $784.26 S22005000 HOsebibs 2 Furnace<100K 1 Planning Review Fee KKK 7/5/2005 $155.00 S22005000 Kitchen Sink 2 Gas Outlets 5 EH Plan Review TW 7/15/2005 $75.00 S22005000 Lavatories 2 Propane Tank 1 Adjust Plan Check Fee DLC 7/20/2005 -$7.28 522005000 Showers 2 Ventilation Fan 3 Building State Fee DLC 7/20/2005 $4.50 522005000 Water Closets (Toilets) 2 Heat Pump 1 Building Permit Fee DLC 7/20/2005 $1,195.35 522005000 Water Heaters 1 Propane Stove 1 Mechanical Fee DLC 7/20/2005 $65.10 S22005000 Bath Tubs 1 Dryer Vent 1 Mechanical Base Fee DLC 7/20/2005 $23.50 S22005000 Clothes Washer 1 Plumbing Fee DLC 7/20/2005 $89.00 S22005000 Plumbing Base Fee DLC 7/20/2005 $20.00 S22005000 Public Works Review AT 7/26/2005 $39.22 522005000 Mechanical Fee KKK 3/16/2006 $10.65 522006000 Mechanical Base Fee KKK 3/16/2006 $7.50 522006000 Total $2,461.80 BLD2005-01107 Please refer to the following pages for conditions of this permit. Page 1 of 5 CASE NOTES FOR BLD2005-01107 CONDITIONS FOR BLD2005-01107 1) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit rev o n. X 2) A Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at (360)427-9670, ext. 450. The building permit will not be"finaled" until the permit holder can show proof that the access permit from Public Works has been "finale%" approved. X 3) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspectors a made prior to requesting additional inspections. X 4) The internationnl code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X , 5) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X 6) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department pr4orjo any further inspections being performed or approvals granted. X BLD2005-01107 Please refer to the following pages for conditions of this permit. 2 of 5 7) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads,"all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspections. X 8) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-09� a son signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X S 9) Retaining walls needed to contain slopes require a seaparate permit and approval prior to construction. Retaining wall shall be designed in accordance to geotechnical report recommendations. w X 10) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 11) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Depagme , prior to any further inspections being performed or approvals granted. X 12) Washington State Energy Code Compliance has been approved using the following: Heat Type: Heat pump with Electric forced air furnace, Compliance Method: IV, Window(Max U-Factor):0.40, Skylight (Max U-Factor):0.58, Doors (Type/ :tol):0.40 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38. X 13) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X� 14) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and sha collected by the Building Department prior to any further inspections being performed or approvals granted. X / BLD2005-01107 Please refer to the following pages for conditions of this permit. 3 of 5 15) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. , X 16) All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. X 17) All property lines shall be clearly identified at the time of foundation inspection. X 18) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason Countysrdipancep and building regulations. X .._ 19) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder havelarevented action from being taken. No more than one extension may be granted. X .,SI 20) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, hirig. Install metal connectors approved for contact with the new types of pressure treated material. X � i— 21) Approved pi�r­dim" ion,; and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 22) The approval of this project is subject to the recommendations and specifications outlined in the attached geotechnical report or assessment. Structures and/or land modifications (grading, cuts,fills, etc.) required in the geotechnica t/assessment, may require a seperate permit. The geotechincal report/assessment shall remain attached to the approved building plans. X 23) The Mason County Resource Lands and Critical Areas Ordinance requires vegetative management of the site. There shall be a minimum disturbance of trees and vegetation in order to minimize erosion and stabilize Landslide Hazard Areas. Limbing trees for view purposes is preferred over tree removal. X BLD2005-01107 Please referto the following pages for conditions of this permit. 4 of 5 This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at anytime after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for revi ins tion. OWN ER OR AGENT: DATE: BLD2005-01107 Please referto the following pages for conditions of this permit. 5 of 5 1 C COtt BETE, MECHANICAL MOBILE HOME Footings-Setback date by Ribbons date by Gas piping date by Foundation Walls date by Set Up ' date INSULATION date by BG/SLAB Insulation Floors Final date by date by date by FRAMING Walls FIRE DEFT. date by date by date by PLUMBING Attic OTHER Groundwork date b date by D.W.V. WALLBOARD NAILING date by date by Water Line FINAL INSPECTION date by date by date by I d - iv- 4w e PA o's 0,- 4ec. I-toI— ,',A4 cot st°c�( — Cain Le I c, C4 i k a hrS\cJ:n r L u� G•G s �%� I� i co NI CONCRETE MECH CAL "MANUFACTURED HOME C) Footings r Setbacks pat® 1 �� By Ribbons Date By Gas ibiping ?: , -r 9 0 Zt�oS (;" ,P []ate By 4 Foundation Wails pate /0j1% By L r— 455 Set-up Date v B ` INSULATION Date By BG I Blab insulation Floors FI NA L I NSPECTION Date By Date "modVffO y pate By FRAM INO,,,,//�� Wall* FIRE [DEPARTMENT pate b (�{�� Dated (p MY Date By PLUMBING o ' i -OTHER Groundwork pate 2 I 1y � By r" - l u N �� � 0 Date By WALL130ARD NAILING Date By OWN Date `rkwr'"�`�, h"3'� �r�. , -U — 12�6 w Watert_ FINAL.INSPECTION Dat t)ale Bytzx Date By s Type of Insp. Pass/Fail Request Bate Inspect. Date Gone By Comments 61 CD '' w o lt�11or o o� twer w� owe CD cv�k.ri Il3i O6 Z �?Alk2l��Sf�u�3 �xt7'% W rn -1Vr ' L`k�e s v v 8 0 / V1 X T ►N i e - �T wo to :c /Yi C o Q w�l! �a,•��, e o v /- /, t f'� ✓11''�i? •r�' Z 644 -was s' o..a l 4-D u v� X ;Z, 40 ��� 5�- F}; I 7— � o(� 2 u Ago" ,,,,f 1 X y `i r Ii'� eS 3� 2Y d�RR ,&�tWJ Q, yl- 1 12T o� Erg Sbrr,,r> o to 57 iV\ w u 5/10/6(. L+�� �mfxm� Ire Building Permit # MASON COUNTY 007 BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location z/ C r"-r ew cl � R, This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance l . a;4541-A'r'rdN AT- skti, I itzs d LcsT ,RrL iA �r h You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing eke corrections, items will be checked on next inspection U�-�to '0 Lzw',"W/ 444R -L4--60"V'- 6"10(Q-4w- ID ❑ This is not a co plete inspection Department Dat6 Inspector n DO NOT REMV THIS TAG MASON COUNTY FIRE MARSHAL Mason County Bldg.III 426 W Cedar St PO BOX 186 Shelton,WA 98584 (360)427-9670.Ext.273 CODE ENFORCEMENT FIRE INSPECTIONS FIRE INVESTIGATION PUBLIC EDUCATION To: Grace Miller L Fm: Craig Haugen k1pbe: t: 11-14-2007 Hydrant Flow @ 251 E Great Bend Dr. Grace Miller: This is the observed fire flow performed at the hydrant located adjacent to 251 E Great Bend Dr. on November 6, 2007•@ 1400. The static—residual hydrant was located at E Union Heights PI N. The `projected available hydrant flow' was not calculated due to the residual pressure dropping below 20 psi. The static—residual hydrant pressures are low due to the test hydrant's minimal elevation drop in relation to the storage tank. Cr 'g Hau3unty r _ *BETA Version* Mason Fire shal Fire Hydrant .Flow Calculator ®2006,Willis Lamm • Use the tab key to navigate. . Tab between each box to update the calculation. . Be sure to tab past your final entry for a correct calculation. Static: 122 1 psi before flowing Residual: 16 . psi while flowing I Pitot: 14 pitot gage reading Diameter:. 2.25 Size of opening tested This.hydrant is flowing: 509 GPM from the test outlet Projected available hydrant flow: GPM Note 1 2nd Static: I l secondary psi before flowing 2nd Residual: secondary psi while flowing The main can be expected to flow about: NaN GPM Notes: 1. Projected available flows calculated at 20 psi residual, or %2 the static pressure for low pressure hydrants having static pressures of less than 40 psi. 2. This calculator is based on established Hazen-Williams formulas and is provided for convenience and estimation purposes only. The author and,FireHydrant.org express no warranty for its suitability for any particular purpose. Click for Legal Disclaimer Wage 1 of 6 2006-02-06 18:27:01 (GMT) 14197304046 From:Owens Corning Web Site ■ ti FAX COVER SHEET TO COMPANY FAX NUMBER 13604262698 FROM Owens Corning Web Site DATE 2006-02-06 18:28 : 13 GMT RE Document/Literature Request from Owens Corning COVER MESSAGE The following information was requested to be sent from the Owens Corning website. Publication Title: OakridgeAD PROa„4 Series Laminate Shingles Publication Type: Installation Instruction Publication No. : 15-RR-15959-E This information was requested by: First Name: Johnnie Last Name: Ponzie Comments : Per your request. Do not reply to this e-mail . If you need any additional information, please visit www.owenscorning.com or call 1- 800-GET-PINK (1-800-438-7465) to speak with one of our representatives. *******************Electronic Mail Confidentiality******************** The information contained in this communication, and its attachment(s) , is intended only for the use of the individual to which it is addressed and may contain information that is privileged, confidential, or exempt from disclosure. If the reader of this message is not the intended recipient, you are hereby notified that any dissemination, distribution, WWW.EFAX.COM To: Page 2 of 6 2006-02-06 18:27:01 (GMT) 14197304046 From:Owens Corning Web Site i or copying of this communication is strictly prohibited. If you have received this communication in error, please notify us and delete the communication without retaining any copies . Thank you. WWW.EFAX.COM To: Page 3 of 6 2006-02-06 18:27:01 (GMT) 14197304046 From:Owens Corning Web Site Installation Instructions Oakridge PRO' Series Laminate Shingles i These laminated shingles are designed for new or reroofing work over any properly built and supported wood roof deck having ade- 1 a Deck Preparation quale nail holding capacity and a smooth surface. For standard slope Decks(a"in 12" or more) UL Class A Fire Resistance Application of underlaymenL,metal drip edges and eaves flashing: & Wind Resistance P g Ratings (A)Apply one layer of underlaymenL over metal drip edge at eaves. 9 Use only enough fasteners to hold in place. Mien applied in accordance with these instructions,Lhese shingles (B)Overlap successive courses 2'Overlap course ends 4' carry the Underwriters Laboratories Class A fire resistance rating. Side laps are to be sLaggered 6'apart. the Lop rating for residential shingles.They will resist exposure to (C)Apply metal drip edge over underlayment a rake. PP Y P g lire in accordance with UL Standard 790.When applied properly, Note:Where Ice-damming may cause leaks.apply Owens Corning these shingles _ g .. � e s g es also meet UL wind resistance Standard 997.All]amI WcathcrLock°underlayment.or c trivalent caves flashing at least.24 q !; nated shingles have a factory-applied strip of special thermoplastic beyond the inside wall line.When using a coated smooth roll or mineral adhesive on each shingle.After direct exposure to the sun's heat, surfaced roll roofing.apply over the underlayment..When using a spe- clall.y eaves flashing product,foll(nv the manufact.urer's lnstrucuons. each course bonds securely to the course below(a matter of days in spring d ough fall seasons,in winter it varies depending on geographical location,roof slope and orientation of the house on the site,in relation to Lhe sun). Other Roofing Materials • iBl .. .....Rake. .. Metal Drip Edges-are recommended along rake and eaves edges of all decks. (A).. Eaves underlayment-is recommended for roofing over any bare deck, and is re qulred for a UL(,lass A fire rating.Use only"breather type'material such as Asphalt Saturated Felt or Shingle Underlay- 1 b peck Preparation merit classified by UL as a Prepared Roofing Accessory to assure Class A fire performance and watertight performance from For Low Slope Decks(2"in 12" to less than 4" in 12") wind-driven rain. Application of underlayment,metal drip edges and eaves flashing: Nails-must be galvanized,I I-or 12-gauge,with heads at least (A)Apply 19'starter strip of underlayment over metal drip edge a 3/8"in diameter.Staples must be 16-gauge minimum, 15/16' eaves.Use only-enough fasteners to hold in place. minimum crown width and sufllcienL length to penetrate 3/4'into (B)Use 36'strip of underlayment for remaining courses,overlap- wood decking or through APA rated roof sheathing.Staples are ping each course 19"'Side laps are to be staggered 6'aparL. Lo be corrosion protected. (C)Apply metal drip edge over underlayment at rake. All Fasteners-must penetrate at least 3/4"into wood deck or Now:Whcre caves flashing is required apply Owens Corning Weather- completely through plywood sheathing. Lock underlayment or equivalent specialty eaves flashing product or Note:Owens Corning recommends the use ofnalls as the apply a continuous layer of asphalt plastic cement.between the plies of underlayment at.least.21 beyond the inside wall line. preferred method of attaching shingles to wood decking or other nallable surface. Plastic Cement-where required must meet ASTM D 4586 Type 11 (As besLos Free). (Cl Rake. . (B1.. Ask.'.:.'•••.. Eaves. (A). To: page 4 of 6 2006-02-06 18:27:01 (GMT) 14197304046 From:Owens Corning Web Site Laminate Shingles Oakridge PRO''' Series 2 Shingle Application Apply shingles over properly prepared roof deck,starling al bottom of roof and working across and up.This will blend shingles from one bundle into `. Lhe next.and minirnizes any normal shade variation. Lanunated shingles are applied with a 6-1/2"oll'seL.While a 6-1/2"of lseL is recommended,any ,- repeatable offset pattern from 4" Lo 8"is acceptable.Caution must be exer- (A)-' Eaves 5°/yam cised to assure that end joints are no closer than 2"from a fastener in the shingle below and that side laps are no less than 4"in succeeding courses. Refer to course applications steps for specific instructions. Starter Course(see illustration on the right) (A)Trim Labs off all sLarLer course shingles. (B)Trim 6-1/2"o[T rake end of lirsL shingle.ExLend 3/8"beyond rake and te) ls) (A) eaves,and fasten. (C) L f L L l C:om ee res o sarLer course. p 5eh".....'......... Note:Start.at rake edge.Use flue fasteners for each shingle,placed 2'to 3-lipwith rake from the eaves. First Course (A)Apply first.course sLarting wilh a full shingle,even with the sLarLer course.Fasten securely according Lo inductions. Not.e:Coniplet.e course with full shingles.The fastening line should not.be used for course alignment.of shingles. Second Course (B)Begin second course by positioning IirsL shingle 6-1/2" li•om Lhe end o1' Lhe underlaying shingle,and flush with the Lop of Lhe overlay Lab (dragon tooth). (C)Leave 5-5/8"exposure,fasten securely,and trim excess overhang at rake. Not.e:Coniplet.e course with full shingles. Third Course (D)Begin by positioning Lhe first shingle 6-1/2"from Lhe end of Lhe underly- ing shingle,flush wiLh the Lop of the dragon LooLh paLLern. CompleLe by repeating step (Q. Note:CompleLe course with full.shingles. Fourth Course (E)Begin the fourth course by positioning Lhe IirsL shingle an additional 6-1/2"li•om Lhe end of Lhe underlying shingle, [lush wish Lhe Lop of Lhe dragon LooLh paLLern CompleLe by repealing sLep (C). Note:Complete course with full shingles. Fifth Course (F)Begin fifth course by positioning full shingle flush with rake edge and leave 5-5/8"exposure. CompleLe by repealing sLep (C). Note:Coniplei.e course with full shingles.For succeeding courses repeat.steps for second.third.fourth and fifth courses. To: Page 5 of 6 2006-02-06 18:27:01 (GMT) 14197304046 From:Owens Corning Web Site 3 Valley Construction .:.'.Vetiey.un.r: =-- B•Mtn. A closed cut valley is recommended and is applied as follows: Extra Na.'*IS Asphaltp4utlp•,•• •.. (A)Lay a 36"wide valley liner of smooth surface roll roofing or updprtay+nent:• Cement,•: ;,'• Owens Corning ReatherLock underlayment or equivalent.product. Fasten on outer edges only. °x g Clip_corner.' (B)Lay all shingles on one side of valley and across centerline of valley a minimum of 12' Fasten a minimum f u o 6"away from centerline on each side of valley. :<; Centerlin:: r (c)Strike a chalk line 2'from the centerline of the uishingled side.Apply shingles on the unshingled side up to the chalk line and trim,taking care not Lo cut the underlying shingles.Clip upper corners of these shingles, cement and fasten. (D)A metal valley is an acceptable alLernadve.A woven valley is also acceptable for OakridgeO PRO30". 4 Fastening Instructions "StarKiardArea High Wind,. Mansard or Place fasteners 6-1/8"from bottom edge of each shingle and 1'from each end. Steep Slope (A)Use four fasteners in normal wind areas. Q.e h fi=(B)Use six fasteners per shingle for mansard construction Use of six ,,< ` ' --- ' .:.. w ems:: fasteners is recommended in high wind areas. svr 5v. Expesnre ex•..........:: Dragon Tooth--"'"Shingle ....... ... Note:Fast.en on the 6-18'nall line to penetrate both segments of the shingle. Side View Fastener Through teen Ltti•': 5 Hip & Ridge Application Higli Ridge Hip&Ridge and High Style'Hip&Ridge available by region. Hip and ridge cut from If cutting three Labs for Hip&Ridge shingles,adhere Lo the following 3-tab shingles. instructions. Prevailing Cut full three-tab shingles into three 12'x 12' (13-1/4"x 13-18"metric) Wind Direction r— Hip&Ridge shingles.Start hips at the eave and work up to ridge.Apply 5-5j8'•Fastaniny Distance ridge only after hips have been applied,beginning on end of ridge opposite prevailing wind direction.Leave 5" (5-,Y8"metric) exposure per shingle for Hip&Ridge application.Bend over the ridge;fasten on each side 5-518' _ (6-1/4'metric) from exposed end, 1'up from the edge.Cover exposed nails Hip and ridge cut from with asphalt plastic cement. metric three-tab shingles For more in/ormalio .on Hip&Ridge shingle applicalion refer to 5-518" Owens Coming's'How to Apply Hips&Ridges"(Pub.No. 5-RR-I8491). wind Direction Note:For best.appearance,when using three-i.ab shingles for Hip&Ridge,apply 'A__ double thickness(two 12'x 12'shingles or 13-1/4'x 13-18'if using meirlc-sized a-,�a'"Fastening Distance products).Do not cut.Hip&Ridge shingles from fill size laminated shingles. To: Page 6 of 6 2006-02-06 18:27:01 (GMT) 14197304046 From:Owens Corning Web Site Laminate Shingles Oakridge,) PRO''' Series 6 Precautionary Notes the entire head is flush against the shingle but does not cut The manufacturer will not be responsible for problems the shingle surface.An improperly adjusted pneumatic gun resulting from any deviation from the recommended can result in raised fasteners causing sealing failure,raised application instructions and the following precautions: tabs,leaks or blow-off. (A)Roof Deck:Recommended roof decks are 6"maximum width, Guidelines on fastener size,number and location must be 25/32"minimum thickness wood sheathing,or 3/8"minimum followed.Failure to follow these instructions seriously reduces thickness plywood sheathing.Use plywood decking wind resistance. Owens Corning will not be responsible for any recommended by the American Plywood Association, wind damage that occurs with shingles which have not been Underwriters Laboratories,Inc.,or local building codes. applied in accordance with these instructions. These Owens Corning shingles have been tested and rated as (D)Mansard or steep slopes:For slopes exceeding 60 degrees or Class A by Underwriters Laboratories when these shingles are 21 inches per fool,use six fasteners and four spots of asphalt applied over recommended decks.If other decks are used, the plastic cement per shingle.All six fasteners must be spaced resulting construction may not qualify as Class A. equally and placed in the fastening line.Place four-spots of Regardless of deck type used, the roofing installer must: asphalt plastic cement, 1"in diameter,under each shingle 9.Install the deck material in strict compliance wlLh Lhe deck immediately upon installation. mantiraclurer's instructions. (E)Storage:Store In a covered ventilated area at a maximum .2.Prevent the deck from getting wet before,during and after temperature of 110"17.Stack in a flat fashion (maximum of 16 Installation. bundles high).Protect shingles from weather when stored at 3.Insure the atric ventilation meets or exceeds FHA Minimum Lhe job site.Do not store near steam pipes,radiators,etc. Property Standards. (F)Hip&Ridge Shingles:These shingles should be cut from the back(smooth) side.In cool weather,shingles can be formed Kole:All roof structures,especially Mansard style construction.must. more easily to fit the ride if the are stored in a warm indoor have cnmplel.e through ventilation from bottom to top In prevent Y g Y entrapment.of mnrstllre-laden air(winter) and hot air (summer).Both area,then Laken out immediately before application. conditions may cause premature shingle failure.It.is extremely impor- (G) All exposed material must be rated Class A by Underwriters tans in maintain adequate ventilation when reinsulat.ing or reroofing. Strttclllres with bath and kitchen vents.which are vented directly Intn Laboratories, to maintain a Class A system. the at Uc space.may require additional ventilation I.o remove excess moisture vapor. (e)Handling:Use extra care in handling shingles when the temperature is below 40°F.Do not drop bundles.Shingles can 7 Reroofing be broken easily In cold weather or Lhelr edges damaged In hot If old asphalt shingles are to remain in place,nail down or cut away weather.Do not attempt to separate shingles by`breaking" all loose,curled or lifted shingles.Sweep the surface clean of all them over another object such as a ridge. loose debris just prior to applying the new roofing.Ensure proper (C)Fastening:Owens Corning recommends nails as the preferred size and length of fasteners.If roofing over old wood shingles,cut method of attaching shingles to wood decking or other nallable back the old shingles at eaves and rakes and apply wood edging surface.Drive all fasteners until they are flush with the surface strips.Some local building codes may require the use of a No.30 of the shingle.Special care must be Laken in the use of asphalt saturated felt over the old wood shingles prior to reroofing. pneumatic staples or nail guns.Staples are to be driven with a Consult local building code authorities.The surface must be smooth pneumatic stapler with crown parallel to length of shingle so before shingles are Installed.Make deck smooth by nailing down all that the entire crown bears lightly against the shingle but does loose and curled shingles,protruding nails,etc.install beveled wood not cut the shingle surface.Nails are to be driven straight so feaLhering strips.If necessary. • • OWENS CORNING WORLD HEADQUARTERS ONE OWENS CORNING PARKWAY TOLEDO,OHIO,USA 43659 Pub No.15-RR•15959-[ Printed in U.S.A.,December 2001 Cg7yriyht 0 Z001 Omens Coming To: Page 3 of 3 2006-02-06 18:38:00(GMT) 14197304046 From: Owens Corning Web Site High Ridge Installation Instructions MQD Hip & Ridge Shingles Owens Corning High Ridge Hip end and 1"in from the side edge.All S. Fasten each shingle through the top & Ridge Shingles are designed nails must be covered by succeeding laminated piece with one nail m each to complement laminated and shingles at least V All fasteners must side,place 9"from the exposed end and laminated-looking shingles. They penetrate at least 3/4"into wood deck or 1"in from the side edge.All nails are a high profile shingle which completely through plywood sheathing. must be covered by succeeding adds dimension to your home's In high vend areas apply a spot of asphalt shingles at least 1" hips and ridges. roof cement,the size of a quarter,on each 4. Apply remaining hip and ridge shingles side of the hip or ridge,on the top in the same manner with 8"exposure. laminated piece prior to installing the Before you begin succeeding shingle.Cover exposed 5. When finishing the ridge,leave no Complete shingle application on roof deck fasteners with asphalt plastic cement. laminated portion of the last hip and before applying hip and ridge shingles.IIip Plastic cement must meet ASM ridge shingle exposed.One option is to D-4586 Type I or II(Asbestos Free). use the 8"exposed portion of a hip and shingles must lie applied before applying ridge shingle,cutting a piece the ridge shingles.All hip and ridge shingles are Installing appropriate length to extend over the applied with an 8"exposure.Note:jf a new 1, Begin hi application at the cave laminated portion of the shingle roof is being applied over an existing � p P urtgle to the working toward the ridge. end of the ridge. roof,re-move the old)pip and ridge shiny4;s to obtain a level application. la.Begin ridge application opposite the 6. Fasten final piece with two nails,cacti prevailing wind direction. 1"in from the side edge and 1"in from Fastening s. Arrange the end of the ridge.Cover exposed High Ridge flip R Ridge Use nails orily when installing this product. shingles along the center line so that fasteners with asphalt plastic cement. Nails must be galvanized,11-or 12-gauge, both halves of the laminated piece fall with heads at least 3/8"in diameter.Nails on opposite sides of the hip or ridge. should be placed 9"back from the exposed (Fig.B) 4 Fig.A Prevailing Wind "�� Fig.B Top Viow Sid.View Direction Nail 4 Top laminated Piece t' I ! 4• Neil I Nail I I • • 1 A I I { t_ t" { \\ I I I I B �pesun U i i i i 72' - OWENS CORNING WORLD HEADQUARTERS ONE OWENS CORNING PARKWAY TOLEDO,OHIO,USA 43659 ROOFING SYSTEMS BUSINESS System Thinking'is a trademark of Owens Corning. The Pink Panther is a-"and a of United Artists Corp.Licensed by MGM Consumer Products. Printed U.S.A.,March 2000 Copyright 0 2000 Owens Corning. Mark Core Mark -� Page 1 1117 From: Larry Waters To: Mark Core Date: 11/4/2005 8:27:13 AM Subject: Mark, Mark, I need you to do me a flavor, you did a foundation inspection at 251 Great Bend Dr, It was a mono pour footing and 4 ft.wall. Do you remember if it had vert. rebar. The owner of the house had me out to the site to look at the way it was poured, there appears to be a cold joint part way up the wall for about 80% of the perimeter. Way caused this ?To much time between pours, a hot load ? But what I told him was once we have determined weather or not the there is vert. bar in place than one of two things will occur. Either, if the bar is in place a cold joint can occur between a footing and a wall and I would just want a special inspection report on the concrete, they can check the psi of the concrete. If no bar is in place then a special inspection report will need to be done as well as have an engineer evaluate the foundation and determined if it can be built on and meet all the current requirements set by chapter 16 of the IBC. November 7, 2005 We met with Larry Waters regarding the foundation at 251 E. Great Bend Drive, Union. Larry met with my husband on site and once he looked at the foundation and saw the massive cold joint that was completely around the foundation inside and out he advised us that he wanted further inspections done. Larry spoke with Jerry Waldon superintendent of Stanbrooke Homes and advised him of this . Jerry Walden contacted the sub that poured the foundation and Thursday afternoon November 3ra 2005, Jerry left a message on our answering machine stating that the sub had sent a crew to the site to "SACK" the bad spots . We feel that this was done to cover up before further inspections . Jerry Waldon was fully aware of what was to be done and he still allowed this to be done. We understand that Larry is on vacation and your handling the problem. Due to the fact that Stanbrooke has not been truthful to us we would like to be present at any meetings that you may have with them concerning our foundation if this is possible. Unfortunately, we took only one photo showing the cold joint not realizing that Stanbrooke Homes was going to cover this up. This is not the worst spot, and this cold joint was continuous around the entire foundation, it follows the same line on the inside as the outside. We appreciate the Mason County Building Dept taking the time to insure our home is built properly. We have owned and operated a Concrete Pumping business for 10 years and Ray has recently retired after 20 years as a ready mix driver. Thanks you for your time. Our cell #Is are Ray 360-490-8965 or Connie 360-490-8955. Ray & Connie Bedford 2 v * INNOVATIONS FOR LIVINGTill _- --- Roofing 5ysterr F- ar MAP PRODUCTS ] SERvIrES LITERATURE CORPORATE OC CAREERS OC YMORLDIMDE CONTACT Us KEYWORD SEARCH Oakridge PRO 301 Shingles ROOFINGHOME Oakridge PRO 304D shingles feature muted color blends and ABOUT ROOFING T a subtle single shadow for an understated complement to home exteriors. Their durable, laminated shingle design f'KUDUCTS features rugged, weathering-grade asphalt and atough -WHERE TO BUY-- - _— Fiberglas® mat core. Oakridge PRO 30 shingles are backed by a 70 mph wind-resistance warranty and cant' a UL Class - TOOLS aMISOURCEB 71 A Fire Rating. PERSONAL PROJECT FILE 3-Part Specification CHAMM2IPCODE Data Sheet Current ZIP code Installation Instructions 58682 hinking ab-outZ adding :`: SHINGLE MORS Nominal Size: 13 1/4"x 38 3/4" ASTM D 228 Exposure: 5 5/8" ASTM D 3018, Type I Shingles per Square:66 ASTM D 3161 Bundles per Square:3 ASTM D 3462 Coverage per Square: 99.9 sq. ft. ASTM E 108, Class A -soo-ceT-PINK UL 790, Class A UL 997 You are here: I For Your Home I Roofing System I Roofing System ' 1 1 io my Personal Pr1 Privacy Policy 0 1996-2006 by Owens Coming IT'S THAT EASY! .-'i y'A`Ry'� i�'� '. ' � 1� I' 1 ��' il. :+�' f e� �J.. �. ��. � ' + iiuL"'f _ ++ ,� '�� ,- r � .�t R - R a � =y t i �•� lam', i e, - f.rt � Y. _.ati r .SS r _ - �i Mom. ��� - t � - 1 �� r i r .�-- .� '� ' .. � _ � RK`h . ��!�► ^. `\ ,� t. t''. ��� ,'' �. . .`� �.> s • wa. r ' I {, f • ti _ � Tl v � � r+ � _ � __ .. _ .. _ fib+I _ 't 11 s �:��� � . ;� .�' �j � � e�a e __ � 4 �' '+ _ a., + 1 �� _ " - ��_-- - - , 'S; �o _ "_ _ _,4 __` -�_�- - - �. �� __ i ." _ p i� r Y y� MASON. COUNTY PERMIT NO. ..J�L o BUILDING PERMIT APPLICATION - . 426 W.Cedar• P.O. Box 186, Shelton,WA 98584 - Shelton (360) 427-9670 9 Belfair(360) 275-4467• Elma (360) 482-5269 On the web www.co.mason.wa.us , APPL CANT INFORMATION CONTRACTOR 1 OR ION Owner raNm S Sz.CJ Company Nameme Mailing Address 'O 1 - e fj�T= �.r t7 n V- Mailin Address City ,�.41�13 State .Zip Code��"W 7- City. State Zip Code Phone Ukg9O- Other Ph.ab-N-dm -89!5S Phone Othr Lien/TitleHolder Contractor Reg. xp. f E mail address E Mail Address l-xZ,, :2 r�Y�r tt_A . CoN�.- t Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC/WATER SYSTEM INFORMATION- Connect to ew Lptic -'X Fxisting`Septic Connect.to.Water System Name of Water System Well ,.,._Water System Name of Water System �O I PARC L INFOR TION- 12 Digif P el Na. F' a bistrict Legal Description - Site Address(Please i elude street name, st eet number and city) w Dire tions to site tDl - 0 r Will timber be cut and sold in parcel preparation?Yes 40 Is property within 200'of Saltwater Lake ----,River/Creek - Pond Wetland, Seasonal Runoff_Strearn..j. "Sopes or Bluffs > 15% Is this permit submittal the result of a St INOrk Notice,'Correctio otice or other enforcement action?Yes/No I TYPE OF JOB -New Add Alt Repair Other PRIMARY RESIDENCEN SEASONAL ❑ Use of Building Q- nescribeVyork W 4 L..\ C Q csN I-r u( "n A r`J No.of Bedrooms--::� _No.of Bathrooms • Y, .Square Footage- 1 t Floor � '►3 2nd Floor. r Ord Floor Basement Deck Covered her Sq.ft. Gara e_TA X Attached .— X_Detached Carport Attached _ Detached f MANUFACTURED HOME INFORMATION -Make Model YearY`r Length - Width Serial No. No.of Bedrooms No.of Bathrooms, Type of Heat Purchase Price$ IF Replacement Unit? Yes/No Installer Name Certification No. CWNER/BUL DER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of Psuch is by signature below.I declare that'I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained i permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the inkirmation provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. E PROOF OF CONTINUATION OF W IS Y MEANS OF A PROGRESS INSPECTION. 'r X Date- Owner/Ch ners Re resen ive Con ra or indicate which one FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date DEPARTMENTAL REVIEW APPROVED DENIED NOTES 3 r Building Department t2 -s A - POL� Plannini Department I Environmental Health Department Public Works Department i Fire Marshal _ side atA 101, t FEES Y Building Permit Fee _ Site Inspection Plan Review Fee a� `?7 6P EH Review Fee Plumbing&Base_Fee Planninq Review Fee Mechanical&Base fee Other Wood`/Gas/Pellet Stove Fee State Fee 4r- Violation Fee Pre-Paid at Submittal Valuation$ TOTAL FEES FORM MUST BE COMPLETED IN INK PERMIT NO. i :2� PLEASE FFESS HARD MASON COUNTY PLUMBING/MECHANICAL PERMIT APPLICATION C) 426 W.Cedar•P.O.Box 186, Shelton,WA 98584 Shelton (360)427-gg67�•Be air((360)275-4467•Elma(360)482-5269 On the we�wJvw.co.mason.wa.us APPLICANT INFO MATION CONTRACTOR INIFORMATION Owner Aa 1 Company Name T Ste►'j rime t1 d o* ss/ Mailin Address f`I Mailing Addres 9 City u H lOLA State L✓H Zip Code 9g5�-f Z City i at S�7i 4 Zip Code Phone .3L a y17 Ny �- Other Ph, Phone Other P . Lien/Title Holden °C) �-�a r�� Contractor Reg. G� 'J E mail address i j 16 S yAko* •G'^ E Mail Address Drivers Lic.# S"�'�d u D06 t r-ir Drivers Lic.# DOB SEPTIC INFORMATION - Connect to New Septic— Existing Septic Connect to Sewer System Name of Sewer System PARCEL INFORMATION- 12 Digit Parcel No Fire District Legal Description -3 O T Site Address (Please inc de street name street number and city) Directions to site Is property wi 200'of Saltwater Lake River/Creek Pond Wetlai Seasonal Runoff Stream Slopes or Bluffs > 15% TYPE OF JOB - NewX Add Alt Repair Other Use of Building Location of Fixtures/Units- 1st Floor 2nd Floor. Basement Garage-Closet PLUMBING FIXTURES(Show Number of each) MECHANICAL UNITS ype of Fixture No. of Fixtures Fees Fuel Type:Electric— LPQ_ Natural Gam_ Heat Pump_ Toilets Type of Unit No.of Units Fees Bathroom Sink Furnace Bath Tubs Heatpumps Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer Gas Outlets Kithen Sinks Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hosebibs Dryer Vent Other Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL CV*4ER/BULDER AckxwAedges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from thorn to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants ernployees of Mason Courtly access to the above described property and stricture for review and inspection. PROOF OF I N JOFWOR MEANS OF A PROGRESS INSPECTION. X Date: 3 '1 G-a 6 00 r/Owners Repr entative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by:-Planning Pd Ck# Date Bid Pd Receipt No. DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department k n -r,�1I_vS �6 &A)P Occ Gr T Constr. l �T( Planning De artment Environmental Health Department FEES Plumbing&Base Fee Site Inspection Mechanical&Base fee UFC Plan Review Fee Wood/Gas/Pellet Stove Fee Other Violation Fee TOTAL FEES Permit number BLD- of/o' Mechanical Permit Checklist ► Name of owner: Name of Installer:®Y i..-r Sr-im J 6 1111,fwr ► Fuel Type? LPG Nat Gas Electric Other I� ► ff propane,what is the proposed size of tank(s)? 2 S-V ► What type of mechanical unit will be installed?(i.e.freestanding stove,forced air furnace, etc.) C&w f--j57-1 y-c- ► What is the use of the structure? (Circle one) esid Commercial (A permit application for a commercial mechanical permit will be issued upon satisfactory review by staff. Include a floor plan showing the location of unit(s)and layout of ducL=d with the permit application.) ► Type of structure:((circle one) Site Built Home Manufactured Home Other ► What room will the mechanical unit be located? 167 c A e h ► Will the unit be located in a basement?(circle one) Yes No ► How will combustion air be supplied to the mechanical unit? (Describe, i.e.direct vent,air inlets,etc.) DrkeeT Vem f ► How will the mechanical unit be exhausted to the outside? Applies to appliances using gas,oil or wood fuel. (Indicate B-vent,direct vent,L vent,etc r— ► What year was the structure constructed?2d_Was this structure part of a PUD upgrade? A-v ► What type of controls will be installed? (i.e.thermostat,etc.) P7 Of 0,1g.L j/.' IVOOTIN ► Will the proposed mechanical unit be a heat source?(circle one) Yes No ► Additional information: Typical mechanical fees: Forced air furnace $ 14.80 Heat pump 10.65 Propane tank 10.65 Gas Outlets 10.65 additional outlets over 5, $1.00 each Mechanical base fee 23.50 or$ 7.25 if base fee was paid on an active building or mechanical permit Freestanding unit, fireplace,pellet stove or wood stove $52.30 $4.50 state fee will not be collected on mechanical permits