Loading...
HomeMy WebLinkAboutBLD2004-01862 - BLD Construction Plans (Blue Prints) - 10/3/2005MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Permit Assistance Center SHELTON (360) 427-9670 BELFAIR (360)275-4467 SEATTLE (206)464-6968 ELMA (360)482-5269 FAx: (360) 427-7798 WEB SITE: wvvw.co.mason.wa.us P.O. Box 186, SHELTON 98584 W1 Washington State Energy Code (WSEC) sZi effective July 1, 2002 2000 Ventilation and Indoor Air Quality Code (VIAQ) Code Compliance Application Form The following information will be required for the WSEC and VIAQ plan review: 1. Complete the Washington State Energy Code/ Ventilation and Indoor Air Quality Code (WSECNIAQ)application located on the reverse side. 2. Complete the window and door schedule on the reverse side. Include all windows, skylights, sliding glass doors, french doors and any door that is more than 50% glass. Use rough opening dimensions of the windows and doors. Information about the U -factor of the window will also help to expedite the energy code review. If you are complying with the WSEC by prescriptive path and are using the area weighted average method you must include your calculations. 3. On your building plans note the location and fuel type of water heater, location of exhaust fans (bathroom, laundry, kitchen, etc.) and R -factor of insulation proposed for walls, floors, ceilings and slabs, 4. Questions? Call Mason County Community Development at (360) 427-9670 ext. 284. Additional WSEC and VIAQ compliance information is available on the Internet at: www.energy.wsu.edu/buildings/ Option Glazing Area % of Floor 10 Prescriptive Requirements "for Group R Occupancy Climate Zone 1, Table 6-1 Glazing U -factor Vertical Door Overheadil Factor9 Wall Wall Wall Ceiling Vaulted Above interior4 exterior SIab4 2 Ceiling3 Grade below 4 Below Floors on 12 grade Grade Grade 12% .35 .58 .20 R-38 R-30 R-15 R-15 R-10 R-30 R-10 15%* .40 .58 .20 R-38 R-30 R-21 R-21 R-10 R-30 R-10 Unlimited Family Res „...// Single (R-3) Only *Reference Case/ Call (360)427-9670 ext. 284 for footnote information. Log & solid timber wall with a min. avg. thickness of 3.5" are exempt from the above grade wall insulation requirements. .40 .58 .20 R-38 R-30 R-21 R-21 R-10 R-30 R-10 MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Laika,..1.60--ualfrpritylAQ Compliance Application Owner:�f ,V�c I Telephoner 1 z Parcel#: fl )- 7 q 60/4 Type of project Total Sq. Ft. of heated area:: Heating System Electric wall heater 0 Electric Central Furnace OLPG Furnace O Heat Pump with Electric Furnace 0 Heat Pump with Gas Furnace 0 Boiler, specify fuel type O Other: Specify: Glazing Percentage: ew Residence 1' Floor : ) 420 ( ) Addition 2ntl floor: ) Remodel Heated Basement: OA Ventilation System Check one Manufacturer Windows: Doors: Compliance Method Check one:: Prescriptive Option (see reverse side) circle one: I II IV O Component Performance , Chapter 5 — Calculation worksheets required O Systems analysis, Chapter 4 Whole House Ventilation system using exhaust fans & window or wall fresh air vents (VIAQ 303.4.1) O Whole House Ventilation Integrated with a Forced Air System (VIAQ 303.4.2) O Whole House Ventilation using a Heat Recovery Ventilation System (VIAQ 303.4.4) O Whole House Ventilation using an inline supply fan. (VIAQ 303.4.3) Window & Door Schedule (If needed, attach an additional sheet) Room/location U -Factor Size Quantity Windows: Total Sq. ft. Doors: Total Sq. Ft Total window and door area Total Square Feet Total window & door area / (divided by) total sq. ft of heated area = %of glazing