HomeMy WebLinkAboutFIR2004-00021 - FIR Permit / Conditions - 4/26/2004 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262
Phone: (360)427-9670,ext.352
Mason County Bldg. 3 426 W. Cedar P.O. Box 186
Shelton,WA 98584 C?ew
Irp, FIRE PROTECTION PERMIT FIR2004-00021
APPLICANT: NORTH FORTY LODGING LLC RECEIVED: 4/15/2004
CONTRACTOR: SMITH FIRE SYSTEMS INC. 253.926.1880 LICENSE: SMITH FS1360T E,' ISSUED: 4/26/2004
SITE ADDRESS: 7101 ESTATE ROUTE 106 UNION EXPIRES: 10/26/2004
PARCEL NUMBER: 322335000014
LEGAL DESCRIPTION: SUNNY BEACH LOTS: 10-11 &8-9 EX ALL N OF HWY
PROJECT DESCRIPTION: STANDPIPE (DRY)
GENERAL INFORMATION System Information
Type of Use: COMM Sprinkler Heads: 0 Audible Switches: 0 Pull Stations: 0
Fire District: 6 Flow Switches: 0 Visual Devices: 0 Door Releases: 0
Hood& Duct?: N Pressure Switches:: 0 Smoke Detectors: 0 Duct Detectors: 0
Dry Chemical?: Y Zones: 0 Heat Detectors: 0
Wet Chemical?: N
Sprinkler?: N
Standpipe?: Y SQUARE FOOTAGE FEES
Monitoring Company: First Floor: Type Amount Due Amount Paid
Monitoring Phone No.:()- Second Floor: Standpipe Permit Fee $441.75 $441.75
Auto Fire Alarm?:N Third Floor;:
Standpipe Plan Check $287.14 $287.14
Total: $728.89 $728.89
I R2004-00021 Please refer to the following pages for conditions of this permit. 1 of 3
V&
CASE NOTES
FIR2004-00021
CONDITIONS FOR
FIR2004-00021
1.) PURSUANT TO 1997 UNIFORM BUILDING CODE, ALL SITES MUST HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A
POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. MASON COUNTY BUILDING
DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS. A REINSPECTION FEE, BASED ON
RATES AS ADOPTED BY THE JURISDICTION AND THE 1997 UNIFORM BUILDING CODE WILL BE ASSESSED IF OWNER/CONTRACTOR FAILS
TO POST ADDRESS ON SITE PRIOR TO REQUESTING INSPECTIONS.
i
X ii1)
2.) Functional flow test will be required for permit sign off. X LID
This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is
commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is
by means of a progress inspection.The ownerorthe agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above
described property and structure for review and inspection.
'W OWNERORAGENT: 'f �/U�C 1 DATE:
i
i
i
i
4FIR2004-00021 Please refer to the following pages for conditions of this permit. 2 of 3
I
N
O
O —
J CONCRETE MECHANICAL MANUFACTURED HOME
0
o Footings / Setbacks Date B y Ribbons
0
N Date By Gas Piping Date B y
Foundation Walls Date B y Set-up
Date By INSULATION Date By
B G / Slab Insulation Floors Final
Date B y Date B y Date B y
FRAMING Walls FIRE DEPT
Date By Date B y Date B y
PLUMBING Attic OTHER
Groundwork Date By
Date By WALLBOARD NAILING
D.W.V. Date By
Date By FINAL PECTI
`D Water Line Datelic>1WOqB
Date By Date By
O
00
co
0
f
3
f0
d
O
O
o N /�
a O x
w O �
N O
O
rA7
�1 1
1
W
O
W
FIRE & LIFE SAFETY INSPECTION: STATEMENT OF DEFICIENCY & CORRECTIVE ACTION
FACILITY ADDRESS CITY ZIP PHONE
NAME C
INSPECT W: AGENCY DATF
DAVE-WA�> 360-427-9670 X-273 MASON COUNTY FIRE MARSHAL FD " I
ITEM STATEMENT OF CODE OR WAC CORRECTIVE ACTION CORRECTION
NO. DEFICIENCY REFERENCE REQUIRED REQUIRED BY
DATE
k�
Coo
am
Q .� 3v n �
X0 0 (0 /
Q cn«0 fir/
W
00
00
LA- x � 6o�
Z C4
N
U m x )(Coos
Z > o o00 C�
lo
O O W P
cn ) x N )( cy
Q � I
�dCjs3
IILI--.1) S�
THE DEFICIENCIES DESCRIBED ABOVE HAVE BEEN SIGNATURE REINSPECTION DATE
EXPLAINED TO ME, AND I AGREE TO MAKE CORRECTIONS
NO LATER THAN THE DATES INDICATED /)
PAGE OF PAGES
White Copy: Occupant— Yellow Copy: Fire Marshal — Pink Copy: Fire District
FIRE & LIFE SAFETY INSPECTION: STATEMENT OF DEFICIENCY & CORRECTIVE ACTION
FACILITY ADDRESS CITY ZIP PHONE
NAME
INSPECTOR C AGENCY DAT
s DAVE SAt7ER 360-427-96 0 X-273 MASON COUNTY FIRE MARSHAL FD -7
ITEM STATEMENT OF CODE OR WAC CORRECTIVE ACTION COMEC110IN
NO. DEFICIENCY REFERENCE REQUIRED REQUIRED BY
DATE
d
Q-
= wc►.�� . ��.�� � �� car� �,, < ;
W00
ao
0
_ � C
Z CN
L
O
p - K
c0 L W
Z .0
O o - a
U x
m <1
a 0 �
10
THE DEFICIENCIES DESCRIBED ABOVE HAVE BEEN SIGNATURE REINSPECTION DATE
EXPLAINED TO ME, AND I AGREE TO MAKE CORRECTIONS 1
NO LATER THAN THE DATES INDICATED
PAGE OF PAGES
White Copy: Occupant— Yellow Copy: Fire Marshal — Pink Copy: Fire District
04 fHU 10:09 FAX 253 926 2350 SMITH FIRE SYSTEMS Z 001
SMITH FIRE SYSTEMS, INC.
April 1, 2004
Mason County Fire Marshal
Mason County Bldg. III
426 W Cedar St
PO Box 186
Shelton, WA 98584
Attention: Steve Swarthout
Re: Alderbrook Dock Fire Protection
Steve,
The purpose of this letter is to document the fire protection we are
proposing for the docks at Alderbrook.
P g
NFPA 303 Section 4-5.1 requires Class 1 standpipes where hose
lay distance from the fire apparatus exceeds 150 feet. The
exception states hose racks, hoses and standpipe cabinets shall not
be required on piers and bulkheads. NFPA 14 Section 5-6.1
requires Class 1 standpipes shall be a minimum 4" in size.
Lion we are pro posing the following.
Based on the above information p p g
Installing 2 '/z FHV 18" above the dock spaced a maximu
feet between them l��n
Main standpipe will be 4" galvanized schedule 40 pipe
Branches to FHV's will be 2 '/2" galvanized schedule 40 pipe
All fittings and hangers will be galvanized
Water supply will be provided through the fire department
connection
Fire extinguishers will not be provided
South Puget Sound 1106 - 54th Ave. E • Tacoma,WA 98424 • Phone: 253-926-1880 • Fax: 253-926-2350
North Puget Sound - 3813 - 168th St. NB Ste#1 - Arlington,WA 98223 Phone: 360-651-7701 - Fax: 360-651-2419
04 FU 10:09 FAX 253 926 2350 SMITH FIRE SYSTEMS Q 002
Please let us know as soon as possible if this proposal meets with
your approval.
Sincerely,
Robert Hinton
Designer