HomeMy WebLinkAboutFLoat Specs - BLD Engineering / Geo-tech Reports - 5/10/2021 Brett Ross Residential Float
462 E Treasure Island Dr
Allyn, WA 98524
CALCULATIONS
PREPARED FOR
MARINE FLOATS
313 EAST F STREET
TACOMA, WA 98421
G. L I�
WAsy
0
a � r
a
0 35799
+t' TURAL
NAL E�Gl
05/10/21
PREPARED BY
Ep,9 SittS&hiii
4815 Center Street
Tacoma, WA 98409
May 10, 2021
S& H Job Number: 19,193
SITTS&HILL ENGINEERS, INC. DESIGNED Tic DATE 4/12/2021 JOB 19,193
TACOMA,WASHINGTON (253)474-9449 CHECKED UT DATE 4/12/2021
PROJECT Brett Ross Residential Float
CALCULATION INDEX
BASIS 1
GEOMETRY 2
LOADING 3
GRAVITY DESIGN 4-6
LATERAL DESIGN 7-9
CONNECTION ANALYSIS 10-12
SITTS&HILL ENGINEERS, INC. DESIGNED TJC DATE 4/9/2021 JOB 19,193
TACOMA,WASHINGTON (2S3)474-9449 CHECKED CJT DATE 4/12/2021
PROJECT Brett Ross Residential Float PAGE 1
BASIS FOR DESIGN
BUILDING CODE: 2018 Edition of the International Building Code with State of Washington amendments
shall be used and supplemented with ASCE 7-16.
GRAVITY LOADS: Float Dead Load= 10 psf
Live Load=40 psf
Buoyancy Live Load =20 psf
LATERAL LOAD CRITERIA: Wind Speed = 110 mph, Exposure: D
STRUCTURAL STEEL• Plates,Channels,Angles and Misc.Shapes: ASTM A36 (Fy= 36,000 psi).
Bolts:ASTM A307 Unless Noted Otherwise
WOOD: STRINGERS- DF#2
RFAMS• DF#2
QUI
Sills8thill Designed: TJC Date:3 22 21 Project Number: 19,193
Tacoma,Washington 253-474-9449 Checked: CJT Date:3 22 21 2
Project: Brett Ross Residential Float
Float Layout
20'-0*
z'—o'lil a'—o'
2x8 BLOCKING
GRATING PER DECKING MIN TYP. FLOAT TO
106 MARINE FLOATS PER GSN STRINGER
TYP. AT CORNER 102 CONNECTION
�- 4x10 D.F #2 P.T. FASCIA® ENDS
o
i
N
m 107 ANCHORAGE CONNECTION PER
DETAIL AND NOTE 8
1
0
TYP. AT END
105 MEMBER
104 TYP AT BLOCKING
4x8 D.F #2 P.T. STRINGERS 101 CONNECTION
J
FLOTATION TUBS
PER MARINE 2XIO D.F. 12 P.T.FLOATS DRAWINGS FASCIA, TYP.
BLOCKING/END STRINGER
CONNECTION, TYP.
E� Designed:
S�lls8ch��� TJC Date: 3 22 21 Project Number: 19.193
Tacoma,Washington 253-474-9449 Checked: CJT Date:3 22 21 3
Project: Brett Ross Residential Float
Loading:
Lfroat:=20 ft Length of Float
H:=7 ft Wind projection height
DL:=10 psf Dead load superimposed on framing members
LL:=40 psf Float live load
V:=110 mph Risk category II wind velocity
KZ:=1.03 Velocity pressure coefficient per ASCE 7
Table 26.10-1, Exposure D
KZt:=1.0 Topographic Factor per ASCE 7 Section 26.8.2
Kd:=0.85 Directionality factor per ASCE 7 Table 26.6-1
qZ:=0.00256•KZ•Kt-Kd• V psf=27.12 psf Velocity pressure ASCE 7 Equation 26.10-1
G:=0.85 Guest effect Factor per ASCE 7 Section 26.9
Cf:=1.39 Force coefficient per ASCE 7 Figure 29.3-1
WL:=0.6•qZ- G- Cf=19.2 psf Wind load per ASCE 7 Equation 29.4-1
WWL:= WL•H=134.6 p!f Lateral wind load
Anchor Lateral Loading:
WWL.(Lf(oatl=1346 lbf
2
NOTE: Design anchor 2000 lb lateral load in any direction.
CpDesigned:
S�lls8ch��� TJC Date:3 22 21 Project Number: 19,193
Tacoma,Washington 253-474-9449 Checked: CJT Date:3 22 21 4
Project: Brett Ross Residential Float
GRAVITY DESIGN
Typical 8'x20' Float Stringers:
L:=8 ft Stringer span (between tubs)
w:=3 ft Interior stringer tributary widths (max.)
WDL:=DL• w=30.0 p[f Distributed dead load
w«:=LL• w=120.0 plf Distributed live load
Per attached Enercalc report, DF#2 4x8, P.T. OK
Typical Joist:
L:=4 ft Joist span (between tubs)
W:=3 ft Tributary widths (max.)
WDL:=DL• w=30.0 p!f Distributed dead load
WLL:=LL• w=120.0 plf Distributed live load
DF#2 2x8, P.T.OK
Ep9
sitts& hill 5
Wood Beam File: 9193.eo6
Software copyright ENERCALC,INC.1983-2020,BiId:12.20.8.24
0.ii
DESCRIPTION: Int Stringer
CODE REFERENCES
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set:ASCE 7-16
Material Properties
Analysis Method: Allowable Stress Design Fb+ 900.0 psi E:Modulus of Elasticity
Load Combination ASCE 7-16 Fb- 900.0 psi Ebend-xx 1,600.Oksi
Fc-PHI 1,350.0 psi Eminbend-xx 580.0 ksi
Wood Species : Douglas Fir-Larch Fc-Perp 625.0 psi
Wood Grade : No•2 si
Ft 575.0 psi Density 31.210pcf
Beam Bracing Beam is Fully Braced against lateral-torsional buckling
D(0.03)L(0.12)
4x8
Span=8.0 ft
Applied Loads Service loads entered.Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Uniform Load: D=0.030, L=0.120, Tributary Width=1.0 ft
DESIGN SUMMARY - •
Maximum Bending Stress Ratio = 0.520 1 Maximum Shear Stress Ratio = 0.218 : 1
Section used for this span 4x8 Section used for this span 4x8
fb:Actual = 486.86psi fv:Actual = 31.40 psi
Fb:Allowable = 936.00psi Fv:Allowable = 144.00 psi
Load Combination +D+L Load Combination +D+L
Location of maximum on span = 4.000ft Location of maximum on span = 7.416ft
Span#where maximum occurs = Span#1 Span#where maximum occurs = Span#1
Maximum Deflection
Max Downward Transient Deflection 0.066 in Ratio= 1458> 360
Max Upward Transient Deflection 0.000 in Ratio= 0<360
Max Downward Total Deflection 0.085 in Ratio= 1125-180
Max Upward Total Deflection 0.000 in Ratio= 0<180
Maximum Forces &Stresses for Load Combinations
Load Combination Max Stress Ratios Moment Values Shear Values
Segment Length Span# M V C d C FN C i C r C m C t C L M fb F'b V fv F'v
D Only 0.00 0.00 0.00 0.00
Length=8.0 ft 1 0.132 0.055 0.90 1.300 0.80 1.00 1.00 1.00 1.00 0.28 111.15 842.40 0.12 7.17 129.60
+D+L 1.300 0.80 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length=8.0 ft 1 0.520 0.218 1.00 1.300 0.80 1.00 1.00 1.00 1.00 1.24 486.86 936.00 0.53 31.40 144.00
+D+0.750L 1.300 0.80 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length=8.0 ft 1 0.336 0.141 1.25 1.300 0.80 1.00 1.00 1.00 1.00 1.00 392.94 1170.00 0.43 25.34 180.00
+0.60D 1.300 0.80 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length=8.0 ft 1 0.045 0.019 1.60 1.300 0.80 1.00 1.00 1.00 1.00 0.17 66.69 1497.60 0.07 4.30 230.40
Vertical Reactions Support notation:Far left is#1 Values in KIPS
Load Combination Support 1 Support 2
Overall MAXimum 0.622 0.622
Overall MINimum 0.480 0.480
sitts&hill 6
Wood Beam FIe:19193.ec6 '
Software copyright ENERCALC,INC.1983-2020,Build:12.20.8.24
0.i
DESCRIPTION: Int Stringer
Vertical Reactions Support notation:Far left is#1 Values in KIPS
Load Combination Support 1 Support 2
D Only - - - - - - 0.142 - 0.142 - - - - - ------
+D+L 0.622 0.622
+D+0.750L 0.502 0.502
+0.60D 0.085 0.085
L Only 0.480 0.480
CP'
S�lls&h�ll Designed: TJC Date: 3 22 21 Project Number: 19,193
Checked: CJT Date: 3 22 21 7
Tacoma,Washington 253-474-9449
Project: Brett Ross Residential Float
LATERAL DESIGN
Typical Edge Stringer Chord Analysis:
d:=8 ft Minimum depth of float
Mf(oat:=
z
WwL-Lfroor =6728.8 ft. (bf
8
Pchore'= Mf�or =841 (bf Maximum chord force in float
Per attached Enercalc reports, DF#2 4x8, P.T. edge
stringer OK for chord forces - low utilizations indicate
interaction between edge stringer gravity load and
chord force is OK by inspection
Ep9
sitts& hill B
Wood Column FIe:19193.ec6
Software copyright ENERCALC,INC.1983-2020,Build:12.20.8.24
0.00
DESCRIPTION: Edge Stringer Chord
Code References
Calculations per NDS 2018, IBC 2018, CBC 2019,ASCE 7-16
Load Combinations Used :ASCE 7-16
General Information
Analysis Method: Allowable Stress Design Wood Section Name 4x8
End Fixities Top&Bottom Pinned Wood Grading/Manuf. Graded Lumber
Overall Column Height 20 ft Wood Member Type Sawn
slender calculations) Exact Width 3.50 in Allow Stress Modification Factors
Wood Species Douglas Fir-Larch Exact Depth
Wood Grade No.2 p 7.250 in Cf or Cv for Bending 1.30
Area 25.375 in12 Cf or Cv for Compression 1.050
Fb+ 900.0 psi Fv 180.0 psi Ix 111.148 inA4 Cf or Cv for Tension 1.20
Fb- 900.0 psi Ft 575.0 psi ly 25.904 inA4 Cm:Wet Use Factor 1.0
Fc-Prll 1,350.0 psi Density 31.210 pcf Incising Factors: Ct:Temperature Factor 1.0
Fc-Perp 625.0 psi for Bending 0.80 Cfu:Flat Use Factor 1.0
E:Modulus of Elasticity... x-x Bending y-y Bending Axial for Elastic Modulus 0.95 Kf:Built-up columns 1.0
Basic 1,600.0 1,600.0 1,600.0 ksi Use Cr:Repetitive? No
Minimum 580.0 580.0 Brace condition for deflection(buckling)along columns:
X-X(width)axis: Unbraced Length for buckling ABOUT Y-Y Axis=3 ft,K=1.0
Y-Y(depth)axis: Unbraced Length for buckling ABOUT X-X Axis=20 ft,K=1.0
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Column self weiqht included : 109.994 Ibs*Dead Load Factor
AXIAL LOADS.. .
Axial Load at 20.0 ft,W=0.8410 k
DESIGN SUMMARY
Bending &Shear Check Results
PASS Max.Axial+Bending Stress Ratio = 0.05893 :1 Maximum SERVICE Lateral Load Reactions..
Load Combination +D+0.60W Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k
Governing NDS Forumla Comp Only,fC/Fc' Top along X-X 0.0 k Bottom along X-X 0.0 k
Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections...
At maximum location values are... Along Y-Y 0.0 in at 0.0 ft above base
Applied Axial 0.6146 k for load combination: n/a
Applied Mx 0.0 k-ft
Applied My 0.0 k-ft Along X-X 0.0 in at 0.0 ft above base
Fc:Allowable 410.992 psi for load combination:n/a
Other Factors used to calculate allowable stresses...
PASS Maximum Shear Stress Ratio= 0.0:1 Bending Compression Tension
Load Combination +0.60D
Location of max.above base 20.0 ft
Applied Design Shear 0.0 psi
Allowable Shear 230.40 psi
Load Combination Results
Maximum Axial+Bending Stress Ratios Maximum Shear Ratios
Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location
D Only 0.900 0.380 0.01118 PASS 0.0 ft 0.0 PASS 20.0 ft
+D+0.60W 1.600 0,227 0.05893 PASS 0.0 ft 0.0 PASS 20.0 ft
+D+0.45OW 1.600 0.227 0.04684 PASS 0.0 ft 0.0 PASS 20.0 ft
+0.60D+0.60W 1.600 0.227 0.05471 PASS 0.0 ft 0.0 PASS 20.0 ft
+0.60D 1.600 0.227 3.006328 PASS 0.0 ft 0.0 PASS 20.0 ft
Maximum_Reactions Note: Only non-zero reactions are listed.
X-X Axis Reaction k Y-Y Axis Reaction Axial Reaction My-End Moments k•ft Mx-End Moments
Load Combination @ Base @ Top @ Base @ Top @ Base @ Base @ Top @ Base @ Top
D Only 0.110
+D+0.60W 0.615
Eg9, sitts& hill 9
Wood Column F1e:19193.ec6
Software copyright ENERCALC,INC.1983-2020,Build:12.20.8.24
0.
DESCRIPTION: Edge Stringer Chord
Maximum Reactions Note:Only non-zero reactions are listed.
X-X Axis Reaction It Y-Y Axis Reaction Axial Reaction My-End Moments k-ft Mx-End Moments
Load Combination @ Base @ Top @ Base @ Top @ Base @ Base @ Top @ Base @ Top
+D+0.450W 0.488
+0.60D+0.60W 0.571
+0.60D 0.066
W Only 0.841
Maximum Deflections for Load Combinations
Load Combination Max.X-X Deflection Distance Max.Y-Y Deflection Distance
D Only 0.0000 in 0.000 ft 0.0000 in 0.000 ft
+D+0.60W 0.0000 in 0.000 ft 0.0000 in 0.000 It
+D+0.450W 0.0000 in 0.000 ft 0.0000 in 0.000 ft
+0.60D+0.60W 0.0000 in 0.000 ft 0.0000 in 0.000 ft
+0.60D 0.0000 in 0.000 ft 0.0000 in 0.000 ft
W Only 0.0000 in 0.000 ft 0.0000 in 0.000 ft
Eg.".1
sifts&hill Designed: TJC Date: 3 22 21 Project Number: 19,193
Tacoma,Washington 253-474-9449 Checked: CJT Date: 3 22 21 10
Project: Brett Ross Residential Float
CONNECTION DESIGN
CONNECTION LOADING:
It:=10 ft Float length tributary to anchor
Plat:=It' WwL=1346 lbf
Prens:= Prat —5199.6 [bf Assuming minimum anchor line angle of 15 °
sin(15•deg)
CHECK 1/2" BOLTS:
n:=8 Number of bolts in connection
WOOD CONNECTION CAPACITY ANALYSIS:
Cd:=1.6 Load duration Factor
Zpororre(:=830 !bf Strength of 1/2" diameter fasteners
in single shear per NDS Table 12F
zperp:=510 !bf Strength of 1/2" diameter fasteners
in tension per NDS Table 12F
Pot + Prens = 1.0,connection OK
n•Zpara(le('Cd n-Zperp'Cd
CHECK END BEAM:
Ptens=5199.6 lbf
Paxia('=Plat=1345.8 lbf
Pwrt:= Pten'2 —P(atz =5022.4 lbf
Per attached Enercalc, end beam OK
sifts& hill 11
Wood Column Build:
9193.ec6 l'I
Software copyright ENERCALC,INC.1983-2020, iId:12.20.8.24
r.rr
DESCRIPTION: End Beam
Code References
Calculations per NDS 2018, IBC 2018, CBC 2019,ASCE 7-16
Load Combinations Used :ASCE 7-16
General Information
Analysis Method: Allowable Stress Design Wood Section Name 4x10
End Fixities Top&Bottom Pinned Wood Grading/Manuf. Graded Lumber
Overall Column Height 4 ft Wood Member Type Sawn
slender calculations) Exact Width 3.50 in Allow Stress Modification Factors
Wood Species Douglas Fir-Larch Exact Depth
Wood Grade No.2 p 9.250 in Cf or Cv for Bending 1.20
Area 32.375 in12 Cf or Cv for Compression 1.0
Fb+ 900.0 psi Fv 180.0 psi Ix 230.840 in14 Cf or Cv for Tension 1.10
Fb- 900.0 psi Ft 575.0 psi ly 33.049 in14 Cm:Wet Use Factor 1.0
Fc-PHI 1,350.0 psi Density 31.210 pcf Incising Factors: Ct:Temperature Factor 1.0
Fc-Perp 625.0 psi for Bending 0.80 Cfu:Flat Use Factor 1.0
E:Modulus of Elasticity... x-x Bending y-y Bending Axial for Elastic Modulus 0.95 Kf:Built-up columns 1.0
Basic 1,600.0 1,600.0 1,600.0 ksi Use Cr:Repetitive? No
Minimum 580.0 580.0 Brace condition for deflection(buckling)along columns:
X-X(width)axis: Fully braced against buckling ABOUT Y-Y Axis
Y-Y(depth)axis: Fully braced against buckling ABOUT XA Axis
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Column self weiqht included:28.067 Ibs*Dead Load Factor
AXIAL LOADS. . .
Axial Load at 2.0 ft,Xecc=1.750 in,W=1.350 k
BENDING LOADS. . .
Lat. Point Load at 2.0 ft creatinq Mx-x,W=5.20 k
DESIGN SUMMARY -
Bending&Shear Check Results
PASS Max.Axial+Bending Stress Ratio = 0.9522:1 Maximum SERVICE Lateral Load Reactions..
Load Combination W Only Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k
Governing NDS Forumla Bending Only,Tension Side Top along X-X 0.0 k Bottom along X-X 0.0 k
Location of max.above base 2.013 ft Maximum SERVICE Load Lateral Deflections...
At maximum location values are... Along Y-Y 0.0 in at 0.0 ft above base
Applied Axial 0.0 k for load combination: n/a
Applied Mx 5.165 k-ft
Applied My 0.09778 k-ft Along X-X 0.0 in at 0.0 ft above base
Fc:Allowable 1,728.0 psi for load combination:n/a
Other Factors used to calculate allowable stresses...
PASS Maximum Shear Stress Ratio= 0.5228 :1 Bending Compression Tension
Load Combination W Only
Location of max.above base 4.0 ft
Applied Design Shear 120.463 psi
Allowable Shear 230.40 psi
Load Combination Results
Maximum Axial+Bending Stress Ratios Maximum Shear Ratios
Load Combination C D C p Stress Ratio Status Location Stress Ratio Status Location
W Only 1.600 1.000 0.9522 PASS 2.013 ft 0.5228 PASS 4.0 ft
sifts& hill 'Z
Wood Column File:19193.ec6
Software copyright ENERCALC,INC.1983 2020,BuiId:1220.8.24
i.
DESCRIPTION: End Beam
Sketches
0
Load 1
u7
N
s.za
410
3.50 in