HomeMy WebLinkAboutCOM2003-00157 ReRoof Bldg 8 - COM Permit / Conditions - 10/6/2003 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection(360)ine(36 0,ext7262
Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Phone: (360)427-9670,ext.352
Shelton,WA 98584
L�
COMMERCIAL BUILDING PERMIT COM2003-00157
OWNER: BLUE HERON CONDOMINIUM ASSOC RECEIVED: 9/12/2003
CONTRACTOR: FIELDS ROOF SERVICE INC LICENSE: FIELDRS2621_1 EXP: 9/25/2005 ISSUED: 10/6/2003
SITE ADDRESS: 6520 E STATE ROUTE 106 UNION EXPIRES: 4/6/2004
PARCEL NUMBER: 322335289004
LEGAL DESCRIPTION: BLUE HERON CONDOMINIUM PHASE 1 1/6 INT. UNIT 8-9 PH 1 UND. INT. IN COMMON AREAS & FACILITIES TSI J E 6520
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
REROOF BUILDING#8 BELFAIR TO HWY 106 TO UNION, PAST ALDERBROOK ON LEFT
General Information Construction &Occupancy Information
Type of Use: Condominiums Insp.Area: No.of Units: Type of Constr.: V-N
Type of Work: RRF Fire Dist.: 6 No.of Bathrooms: Occ. Group: R-1
No.of Stories: Occ. Load:
Valuation: $ 28,146.00
Building Height:
Pre-Manufactured Unit Information Square Footage Information
Make: Length: Lot Size:
Model: Width: Building:
Year: Serial No.: Basement: Parking Spaces:
Setback Information
Shoreline&Planning Information
Front: Ft. Shoreline: Ft.
Rear: Ft. Slope: Ft. Water Body: Shoreline Desig.:
Side 1: Ft. SEPA?: Comp.Plan Desig.:
Side 2: Ft.
Fire Protection System Information
Auto Fire Alarm System?: Emergency Key Box?: Standpipe?:
Auto Fire Sprinkler System?: Access Road?: Fire Extinguishers?:
Fixed Fire Suppression System?: Fire Hydrants?: Fire Lanes?:
COM2003-00157 Please refer to the following pages for conditions of this permit. 1 of 4
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Plan Check Fee KR Qr1?i9nnA �,9An F7 q1?nnAnn
Building Permit Fee KR Qn?i?nnA Sd111 r", q?9nnAnn
Building State Fee 'iRN QiAni?nnA ,za An q?9nnAnn
Total $716.72
CASE NOTES FOR
COM2003-00157
CONDITIONS FOR
COM2003-00157
1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance
Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be
obtained at 1-800-647-098 . The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to
WA state law. X
2) PURSUANT TO 199�IFORM BUILDING CODE, ALL SITES MUST HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A
POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. MASON COUNTY
BUILDING DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS. A REINSPECTION
FEE, BASED ON RATES AS ADOPTED BY THE JURISDICTION AND THE 1997 UNIFORM BUILDING CODE WILL BE ASSESSED IF
OWNER/CO�TRACTOR FAILS TO POST ADDRESS ON SITE PRIOR TO REQUESTING INSPECTIONS.
X i r
r
3) ENCLOSED ROOF SYST,EI p THAT ARE EXPOSED TO THE SHEATHING SHALL BE INSULATED TO A MINIMUM R-30 AND INSPECTED
PRIOR TO COVER. X
4) SINGLE RAFTER JOIST ROOF REPLACEMENT SHALL BE INSULATED TO A MINIMUM OF R-30 ALLOWING FOR A MINIMUM OF ONE INCH
CONTINUOUS VENTED AIRSPACE ABOVE THE LEVEL OF INSULATION. X
5) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The
failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being
non-comp)an�yvith Mason County ordinances and building regulations.
X �4
6) ALL CONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND UBC REQUIREMENTS AND OCCUPANCY IS LIMITED TO THE
PERMITTED AND APPROVED CLASSIFICATION. ANY CHANGE OF US�O OCCUPANCY WOULD RESULT IN PERMIT REVOCATION.
CHANGE OF USE MUST BE APPROVED PRIOR TO CHANGE. x
7) CONSTRUCTION PROC�S TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND UNIFORM
BUILDING CODE.x /7p'
8) THE DEMOLITION AND DISPOSAL OF DEMOLITION DEBRIS MUST MEET REQUIREMENTS AS PER MASON COUNTY REGULATIONS.
X
COM2003-00157 2 of 4
TN"permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is
•` commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied.
i
OWN ER OR AGENT: �/�� `� _ DATE:
COM2003-00157 3 of 4
1
CONCRETE MECHANICAL MANUFACTURED HOME '
N
o Footings / Setbacks Date By Ribbons
Wo Date By Gas Piping Date By
cn
Foundation Walls Date B y Set-up
4 Date By INSULATION Date By
B G / Slab Insulation Floors Final
Date By Date By Date By
FRAMING Walls FIRE DEPT
Date By Date By Date By
PLUMBING Attic OTHER
Groundwork Date By
Date By WALLBOARD NAILING
D.W.V. Date By
Date By FINAL INSPECTION
Water Line Date Ymm By WiC
Date Byti°° ` Date By
yi'lay
\MWJ
IM
O
O
O yO�
O V
W O
O
Ouu
1�
U
Y
ti.