Loading...
HomeMy WebLinkAboutBLD2013-00042 Remove 2nd Floor, Balcony - BLD Permit / Conditions - 5/8/2013 Inspec _!ne (360)427-7262 MASON COUNT ''DEPT. OF COMW LAITY DEVELOPMEN-r Phone: , a.0 427-9670, ext. 352 Mason County Bldg. I ' : W. Cedar P.O. Box 2- Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2013-00042 OWNER: JOHN CARROUGHER RECEIVED: 1/15/2013 CONTRACTOR: LICENSE: EXP: ISSUED: 5/8/2013 SITE ADDRESS: 7611 E STATE ROUTE 106 UNION EXPIRES: 11/8/2013 PARCEL NUMBER: 322334400010 LEGAL DESCRIPTION: TR 1 OF E1/4 OF LOT 1 &TL S 6/64 PROJECT DESCRIPTION: DIRECTIONS TO SITE: REMOVE THE EXISTING SECOND FLOOR, REPLACE, ADD NEW BROCKDALE RD TO MCREAVY RD RIGHT ON DALBY RD RIGHT HWY 106 BALCONY PROPERTY ON ELFTAT 7611 WATER SIDE General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 2 Occ. Group: R3 Lot Size: Deck: 351 Type of Work: ADD Fire Dist.: 6 No. of Stories: 2 Occ. Load: Building:1,651 Valuation: $ 131,199.59 Building Height: Occ. Status: Seasonal Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: S 25.0 Ft. Shoreline: 15.0 Ft. Water Body: HOOD CANAL Rear: N 15.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: E 30.0 Ft. Shoreline Desig.: Urban Year: Serial No.: Side 2: W 15.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Water Closets (Toilets) 1 Furnace<100K 1 Plan Check Fee TW 1/15/2013 $577.69 S2201300000001 Lavatories 1 Ventilation Fan 2 Planning Review Fee TW 1/15/2013 $205.00 S2201300000001 Showers 1 Fireplace 1 EH Plan Review MRB 1/15/2013 $ 103.00 S5201300000001 Water Heaters 1 Building State Fee DLC 2/1/2013 $4.50 S2201300000001 Building Permit Fee DLC 2/1/2013 $ 1,172.95 S2201300000001 Mechanical Permit Fee DLC 2/1/2013 $ 109.30 S2201300000001 Mechanical Base Fee DLC 2/1/2013 $2&50 S2201300000001 Plumbing Permit Fee DLC 2/1/2013 $34.80 S2201300000001 Plumbing Base Fee DLC 2/1/2013 $24.70 S2201300000001 ADJUST--Plan Check Fee DLC 2/1/2013 $ 184.73 S2201300000001 Total $ 2,445.17 BLD2013-00042 Please refer to the following pages for conditions of this permit. Page 1 of 6 CASE NOTES �-OR BLD2013-00042 CONDITIONS FOR BLD2013-00042 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X ( t1 - 2) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. XC'ly 3) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X 4- 4) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X k- 5) All wall cavities serving as exterior walls, exposed during construction or remodeling work shall be insulated to the full depth of the wall cavity and inspected prior to covering. Insulation R-values shall be as follows: 2x4 wall cavities min. R-15 and 2x6 wall cavities min. R-21. X e/Z.— 6) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X ` BLD2013-00042 Please refer to the following pages for conditions of this permit. Page 2 of 6 7) Washingt- State Energy Code Compliance has been approved as fc Heat Type. 'ectric or other than electric Compliance Method: Presc. c: ve option III, Window(Max U-�--actor):0.30, Skylight(Max U-F icror):0.50, Doors (Type/Ma= �actor):0.20 or less, Wall rsulation R-21, Floor insulaticr :- 30, Ceiling Insulation R-38 :3c.anced or R-49 standard, Vau , .-:sulation R-38, and Slab s..iation R-10. In addition 'he following credit from Table 9-1 shall be completed: Op-cc, Addtn less than 750 sq. ft X ('1�- 8) A permanent certificate, completed by the builder or registered design professional, shall be posted within three feet of the electrical distribution panel. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section 503.10.2, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 0.00030 Specific Leakage Area (SLA) when tested with a blower door at a press of 50 Pascals (0.2 inch w.g.). Testing shall occur at any time after rough in and after installation of penetrations of the building envelope, including penetrations for utilities, plumbing, electrical, ventilation, and combustion appliances and sealing thereof. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 750 square feet. Reference WSEC 105.4 Certificate and 502.4.5 Building Air Leakage Testing. Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2009 Certificate" and are available in %or%sheets. The Mason County Permit Center will also have some available. X 9) A minimum of 50 percent of all luminaires shall be high efficacy luminaries unless lighting compliance was approved using the options available in WSEC Section 1520 or 1530. Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaries unless permanently installed outdoor luminaires are controlled by a motion sensor(s) with integral photocontrol photosensor or installed in or around swimming pools or water features. All fluorescent fixtures must be fitted with T-8 or smaller lamps (but not T-10 or T-12 lamps). Referenc WSEC 505. X 10) All windows and doors shall be installed and flashed in accordance with the manufacturers written installation instructions and shall be available during inspections. In addition to other inspection(s), an inspection of the flashing shall be required for projects located in an area with a wind exposure of C or D, reference IRC RKL 2.1.4 & IBC 1609.4. The design criteria for this project is established at 85 mph wind speed, exposure C. X11— 11) WIND LOADS - Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. X �,2� BLD2013-00042 Please refer to the following pages for conditions of this permit. Page 3 of 6 12 REQUIREMENTS FOR ROOF COVERINGS. Roof o .e:ings shall be applied in accordance with the applicable pro. -,--is of the current code and -e manufacturer's installation: instructions. X (" `L- 13) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. "NOTE if Stormwater Management option "A" was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X C, �4_ 14) In addition to the inspections required in IBC, Section 109, the owner, the engineer or architect of record acting as the owner's agent shall employ one or more special inspectors who shall provide inspections during construction on the types of work listed under Chapter 17 and as specified by the design professional. The special inspectors duties & responsibilities shall be as specified in Chapter 17. Special inspections shall be performed by authorized inspectors representing Northwest Testing Co. to verify proper installation of epoxy and shear panels designated on approved plans. All welding shall be performed in a certified shop. Welding not performed within the certified shop shall be inspected in accordance with Chapter 17 of the 2009 International Building Code. Special inspection reports shall be submitted to the Mason County Building Department, PO Box 279, Shelton WA 98584 and available for inspection. Inspection reports shall be completed and submitted to the dept. in a timely manner and shall be submitted prior to the framing and final occupancy inspections. X (t__ 15) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be X arged (arxi shall be collected by the Building Department prior to any further inspections being performed or approvals granted. 16) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocat_rl _ X BLD2013-00042 Please refer to the following pages for conditions of this permit. Page 4 of 6 17) The demolition r: disposal of debris must rr= �;; a regulations of Mason C:-:.:-,'y and Olympic Region Cle&�- : Agency(ORCAA). It is unlawful for any person to cause or allow_.-_, : emolition (or major renova-;e­ of any structure unless all :asbestos containing materials have been identified and removed from the area to be dE rr~_fished. Work shall not comr-e-w.e on an asbestos project c! Demolition project unless the ,,wner or operator has obtained written approval from C�� ;CA.2490 B Limited Lane N`.v, Olympia WA 98502, 360.586.': 144/800.422.5623 www.orcaa.org X r.�� 18) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X � 19) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or r�gul�n, must be reviewed and approved by Mason County prior to construction. X 20) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. X 21) Those parts of heating systems that are altered or replaced shall comply with the current Washington State Energy Code, Section 503. When a space-conditioning system is altered by the installation or replacement of space conditioning equipment(including replacement of the air handler, outdoor condensing unit of a split system air conditioner or heat pump, cooling or heating coil, or the furnace heat exchanger), the duct system that is connected to the new or replacement space-conditioning equipment shall be tested as specified in RS-33. The test results shall be provided to the Mason County Building Department at the final inspection. X_ L'l 22) All property lines shall be clearly identified at the time of foundation inspection. X C�f� 23) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X 24) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X BLD2013-00042 Please refer to the following pages for conditions of this permit. Page 5 of 6 2E'' ' ALL SURFACE WATEF ivu POTENTIAL RUNOFF V.': _:_ 33E CONTROLLED ON SIT AND SHALL NOT ADVERSLI` , ;ECTANYADJACENT PROPERTIES NOR IN:: <'._SSE THE VELOCITY FLO. -"�TERING OR ABUTTING ANY STATE OR COUNTY C',,_'•;ERTING/DITCHING SYST .°d OR ROAD WAY. X (1-1 26) The proposed project must be consistent with all applicable policies and other provisions of the Shoreline Management Act, its rules, and the Mason County Shoreline Master Program.X (�— 27) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X (`I- 28) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X e-.L-- 29) No temporary or final occupancy until installation of SWG2013-00011 is approved. X ��- This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is b eans of a progress inspection. The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of oun y cc s to the above described property and structure for review and inspection. OWNER OR AGENT: vrti� DATE: BLD2013-00042 Please refer to the following pages for conditions of this permit. Page 6 of 6 J MASON COUNTY PERMIT NO. 201 BUILDING PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner C7 ref �6re!�t,:k� . C'ar ro"he+^ Company Name 122' s km- :I-- rfl o err'-1�5 Mailing Address 35I b - 24-t'F+ tt"tx- C tr # N W Mailing Address-SS City(f-I-q 1­6- � State W P� Zip Code 9g335 Cit State Ljj Zip Code Phone LZ3"SILL-9/33 Other Ph. Phone la6 -37/07 Other Ph. Lien/Title Holder Contractor Reg. #DtNNy R-1-37386 Exp.TJ/S E mail address E Mail Address Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC/WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic ✓ Connect to Water System Name of Water System Well ✓ Water System Name of Water System PARCEL INFORMATION - 12 Digit Parcel No 322.33 • 4•'1-• 000io Fire District Legal Description -T'K I o-r C I'J+ c,f L c t I E T L.5 col Io 4- Site Address (Please include street name, street number and city) 7(0:, E -Hwy Io(c , [,uLL',m Directions to site bra-� � P_,� -ft Kc.-Re-a--ty Kd r i ooi Kt c-r. ��Lb�, 2d { r�tkE� t-h.�-� Will ti ber be cut and sold in parcel preparation?Yes o Is property within 200' of Saltwater ✓` Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No TYPE OF JOB - New Add Alt � Repair Other PRIMARY RESIDENCE ❑ SEASONAL Use of Building Describe Work t olc�uu+� 2!�-goar Sf_d&b.LaA No. of Bedrooms No. of Bathrooms 2- Square Footage- 1 st Floor 2nd Floor 7/`4 3rd Floor Basement Deck Covered Deck 3 `f Other Sq. ft. Garage Attached Detached Carport Attached Detached MANUFACTURED HOME INFORMATION - Make Model Year Length idth S o. No. of Be No f N B oms Type of at Purchase Pri Rer it? Yes o Inst er Name tifico ment U .ati OWNER/BUILDE14 Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or the contractor. I further declare that I am entitled to receive this pennit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other parry in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF OF CPNTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. Date: 115�13 Owner/ w rs Re resentative Contractor indicate which one FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date DEPARTMENTAL REVIEW APPROV D DENIED NOTES Building Department rB/yl0 o1c%r 00/ Planning Department Environmental Health Department Public Works Department Fire Marshal FEES Building Permit Fee 7a . 9 Site Inspection Plan Review Fee 8 73 7 W.44a EH Review Fee Plumbing & Base Fee 71 �_ ed Planning Review Fee Mechanical & Base fee 14- / 3v Other Wood/Gas/ Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal T 7 Valuation $ TOTAL FEES � 910 05 � a x , a� x 7 ao 5-1 1 �x 3y L Xa- � l C AY'c h� = 3-7 0-15;e 314 MASON COUNTY PERMIT NO. PLUMBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670•Belfair(360)275-4467•Elma(360)482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner t" � �� C1LX1 1lE► Company Name D"-Or S � `e ' ` 308 Mailing Address h-tx- Mailin Address City► State ZipCode CiV el)I� State Zip Code Phone 3 -514- 9 33 Other Ph. Phone `fz�''37�'� Other Ph. Lien/Title Holder Contractor Reg. # Exp._ 'Tf 5' E mail address E Mail Address Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC INFORMATION - Connect to New Septic Existing Septic ;-' Connect to Sewer System Name of Sewer System PARCEL INFORMATION - 12 Digit Parcel No -322.33 Fire District Legal Description IT F- I & Q- III{- of L'C'l I !--rL-S Site Address (Please include street name, street number and city) -7/011 f52 f'W lob LLI-Lt,rn-1 Directions to site t le. 12-8 `t c 9` S-E f -d, r i%tom' a� Pm t by d ►^i - ►e,1• v- r wtj t C b rn e r C"\ �f -+ v i A e 7(o I I Is property within 20 of Saltwater ✓ Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% TYPE OF JOB - New Add Alt ✓ Repair Other Use of Building -5�77- Location of Fixtures/Units - 1 st Floor 2nd Floor Basement Garage Closet PLUMBING FIXTURES (Show Number of each) MECHANICAL UNIT Type of Fixture No. of Fixtures Fees Fuel Type:Electric_LPG_Natural Gas Heat Pump_ Toilets _ Type of Unit No.of Units Fees Bathroom Sink Furnace Bath Tubs — Heatpumps Showers Spot Vent Fan Z Water Heater Propane Tank Clothes Washer Gas Outlets Kithen Sinks Wood/Gas/Pellet Stove Dishwasher x Kitchen Exhaust Hood Hosebibs ^ _ Dryer Vent �X Other Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF OF CONTINUATION(?f WO K IS BY MEANS OF A PROGRESS INSPECTION. X Date:_ Owner Owners Re resentativ /Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Planning Pd Ck# Date Bid Pd Receipt No. DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Occ Grou —Type Constr. Planning Department Environmental Health Department FEES Plumbing & Base Fee Site Inspection Mechanical & Base fee UFC Plan Review Fee Wood/Gas/Pellet Stove Fee Other Violation Fee TOTAL FEES Hood Canal EXISTING DOCK *'SHORELINE SETBACK LINE CONCRETE BULKHEAD BELOW(MHW) NEW UPPER FLOOR ADDITION BOTH ��, SIDES OF EXISTING UPPER FLOOR- ROOF NG I23 8Q FT.TOTAL ADDED AREA OVER EXISTING DECK REMAINS TYP. EXISTING UPPER FLOOR (REPAIR AND REPLACE AS Ma'D.) NEW DECK IN EXISTING DECK 11 .20 (L0V T) �_ PLANTER AREA 115.15 (CALL) �— Zm'SIDE SETBACK LINE ` — xisting \ ErUl-TAW SEPTIC 876TE1 CONCRETE BULKHEAD(MHw) �'' Residence \ NEW DECK ABOVE I'm Sa FT. I PARKING SPACE PROJECTED \ NEW SPIRAL STAIR \ / \ -"� 1 _——— NEW Lh I ROOF Im'FRONT SETBACK LINE _ \\ N 83_29_38_E----------- (ADMINISTRATIVE VARIANCE \ —— —— I - ---- --------`---- EX16TNG BIND REMAINS -----------L ----- ----------`---- Shed I E \ HIGHLLt47 PAVING ------------------ 1 ___ \ 1 \ �1 \ 10 DRAINAGE OUTFALL '! SR J 06 LINES 1'o __ — EDGE OF HGFIWAY PAVING -— N i3'i9'38" E E ---- 1 ¢DITGH�------------------ -----`.---- ----------------------------- 1 �HIGNWAY RIGHT-OF-WAY LINES I0'FISH 4 WILDLIFE OLFFMSET15ACK LINE 1 1 I 1 �_...� APPROVED IMASON COUNTY OCD PLANNING ' SITE PLAN REO ;I QED TO BE ON SITE CHANGES SUS '_;;"f 7U APPROVAL I PI-A 1 By Daa -_ 1 V I LPROJERCT10tj LL SETBACKS AREMEASUREDg1, THE FURTHESNG WELL OF THE QU�LDING Site Plan Scale. P EXISTNG RESIDENCE PROJECTED ROOF AREA- 1,IW 8Q FT. PROPOWD ADDED UPPER FLOOR AREA- 123 6a FT. (ALL WITHIN EXISTING ROOF FOOTPRINT) Named lAt u°.r Parcel# .5 BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code, Title 14, Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development, or redevelopment',with more than 2,000 square feet of impervious surface 2. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area 'All dimensions in feet Buildings X = X = Measurements for buildings are taken at the X _ perimeter of the farthest projections (example: eaves/gutters) X = Driveways X = X = Length of drive begins at the right of way X = Parking Areas X = X = Any paved, gravel or packed area per definition above table X = Patios/Walks X = X = Any paved, gravel or packed area per definition above table X = Others X = X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor. I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X �> v—"d�— Owne Agen Contractor(circle one)Date: I�15�13 If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read,acknowledge and sign the information provided on page 2 of 2. Pagel of 2 . Name r Parcel#32233 Coe I Q-) BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14, Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to "Title 14, Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70). You will receive a copy of the Public Works document entitled "Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions, guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT. 450 Mail: P 0 Box 1850, Shelton WA 98584 Physical: 415 N 6th St, Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other, parcel.You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail: P 0 Box 1666, Shelton WA 98584 Physical: 426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/ g�enyContractor(circle one)Date: Page 2 of 2