Loading...
HomeMy WebLinkAboutBLD20307 SFR - BLD Permit / Conditions - 5/28/1987 � k Shorel ines: ',+//1 P1 nbi n�q: Setback: Mechani a-rr—� Special Interior: Conditions: FINAL:e��/ice MobileHome: Smoke Detector: Remarks: 0o i Setback: ,,• Foundation Wal l s: �7 Framing:, -7 Fireplace: Wood Stove: . , TYPE RESIDENCE Permit No. 20307 No. Floors 1 Sq Ftg 1680 Owner STANFORD, Eldon Tel Date 5-28-87 Address W 860 Little Egypt Rd Shelton Zip Contractor Lumbermens Address Shelton Zip Legal Description Tr SE}SE 18-20-4 Direction to project site MAP ATTACHED Plumbing x Mechanical x Sewer oo tove x Fireplace Deck -a rage import Basement Loft Other 3 bdrm � y i I � i 1sr Az or. i BUILDING PERMIT APPLICATION MASON COUNTY DEPARTMENT of GENERAL SERVICES P.O. BOX 186 SHELTON, WASHINGTON 98584 426-5593 DATE ISSUEDv/���eP7 PERMIT NO. �CJ%,5Q OWNER NAME MAILADDRESS CITY&STATE ZIP PHONE ,C oyv s Div �� l vE'STx6o Il L DIRECTIONS ems, TO JOB SITE 11y LEGAL or Ti�� S iy s�c�./� o �-►, DESCR. pw -,z lv ofQ Y v 00 20 NAME MAILADDRESS CITY&STATE ICENSENO. ZIP PHONE CONTRACTOR v�4I3 ME•�/.S •O• �o,X JOU Sf_-110W U��z? .T;7 T 'Yz�-�6� USE OF BUILDING If'rsi CLASS OF NEW ADDITION ALTERATION REPAIR MOVE REMOVE WORK ✓ DESCRIBE _ WORK BEDROOMS DECKS /VbAIF- CARPORT ItV /E NOTICE SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, HEATING, VENTILATING OR AIR BATHROOMS TOTAL SO.FT. GARAGE CONDITIONING. NO.OF STORIES L BASEMENT NONE ATTACHED THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR TOTAL SQ.FT./%/,_f_V FIREPLACE DETACHED ABANDONED FOR A PERIOD OF 180 DAYS AT ANYTIME AFTER WORK IS COMMENCED. PERMANENT ` SHORELINE 1410 SEASONAL OWNERSAF IDAVIT CONTRACTORS AFFIDAVIT I CERTIFY T AT I AM EXEMPT FROM THE REQUIREMENTS OF THE CONTRACTORS I CERTIFY THAT I AM A CURRENTLY REGISTERED CONTRACTOR IN THE STATE OF CERTIFY LAW RCW 18.27, AND AM AWARE OF THE MASON COUNTY ORDINANCE WASHINGTON AND I AM AWARE OF THE ORDINANCE REQUIREMENTS REGULATING THE REQUIREM TS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL WORK DONE WILL BE WORK FOR WHICH THE PERMIT IS ISSUED AND ALL WORK DONE WILL BE IN IN CONF MANCE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT FIRST CONFORMANCE THEREWITH.NO CHANGES SHALL BE MADE WITHOUT FIRST OBTAINING OBTAINI APPROVAL FROM THE BUILDING DEPARTMENT. APPROVAL FROM THE BUILDING DEPARTMENT. O ER DATE X BY �/ V�/ �`� DATE �� 7 FOR OFFICE USE ONLY D ARTMENT YES APPROVEDJ0 DEPARTMENT YES DEPARTMENT BUILDING VALUATION HEALTH PUBLIC WORKS FEE PLANNING FIRE BUILDING PERMIT .yes'I, D.O.T. BUILDING PLAN CHECK o v SPECIAL CONDITIONS BUILDING GROUP �"- PRE-INSPECTION SHORELINE 011-14z PLUMBING MECHANICAL STATE BUILDING FEE �F STATE SURCHARGE APPLICATION ACCEPTED BY PLANS C/HQKpBY APPROVED FOR IS ANCE PERMIT VALIDATION BY CASH CK MO TOTAL PLUMBING & MECHANICAL PERMIT APPLICA MASON COUNTY DEPARTMENT of GENERAL SERVICES P.O. BOX 186 SHELTON, WASHINGTON 98584 426-5593 DATE ISSUED PERMIT NO. OWNER NAME MAILADDRESS CITY&STATE ZIP PHONE 10 n 02 fsT L�/�L DIRECTIONS TO JOB SITE LEGAL / _ DESCR. T/�//C' 4 Z �/`��f G^ Off"r��� S/ /'Y S fe'. NAME MAILADDRESS CITY&STATE LICENSE NO. Z ONE CONTRACTOR LU�41� S 'X& U USE OF BUILDING PLUMBING FIXTURES MECHANICAL FIXTURES NO. 2.00 PER FIXTURE OR TRAP FEE NO. TYPE OF FIXTURE FEE WATER CLOSETS L C C FORCED-AIR I GRAVITY TYPE FURNACE 6.00 BASINS v C FLOOR/SUSPENDED FURNACE 6.00 BATH TUBS o G BOILER I COMPRESSOR 6.00 SHOWERS C o REPAIR/ALTERATION 6.00 WATER HEATERS c REFRIGERATION COMPRESSOR SYSTEM 6.00 AUTO.WASHER I - AIR HANDLING UNITS 7.50 SINKS D. c HEAT-PUMPS 6.00 FLOOR DRAINS EACH GAS PIPING SYS.2.00 PER OUTLET DRINKING FOUNTAINS > VENT.FAN SYS.3.00 PER UNIT C d LAUNDRY TRAYS WOOD STOVES 5.00 CONNECT TO CITY SEWER WOOD FURNACE 5.00 DISHWASHER C Gi DISPOSAL URINALS 1 PERMIT BASIC FEE 3.00 PERMIT BASIC FEE 10.00 TOTAL TOTAL �•�� SPECIAL CONDITIONS: NOTICE: THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS,OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. OWNERS AFFIDAVIT: I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF CONTRACTORS AFFIDAVIT: I CERTIFY THAT I AM A CURRENTLY REGISTERED THE CONTRACT OR REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON CONTRACTOR IN THE STATE OF WASHINGTON AND I AM AWARE OF THE ORDINANCE COUNTY ORDINANCE REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL REQUIREMENTS REGULATING THE WORK FOR WHICH THIS PERMIT IS ISSUED AND ALL WORK DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WORK DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT FIRST OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT. WITHOUT FIRST OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT. X OWNER DATE X BY DATE FOR OFFICE USE ONLY APPLICATION ACCEPTED BY PLANS CHECK BY BUILDING GROUP APPROVED FOR ISSUANCE PERMIT VALIDATION APPLICATION ACCEPTED BY PLANS CHECK BY 7 IBY CASH CK Uo CALCULATIONS FOR WALLS STANFORD RESIDENCE ----------------------------------------------------- WALL 1 SYSTEM R VALUES R VALUES WALL 1 AREA AREA U Ux HEATING 1 FRAMING CAVITY HEATING (S. F. ) RATIO VALUE RATIO ----------------------------------------- --------------------------------------------- 1 AIR FILM OUTSIDE 0. 17 0. 17 13 GROSS WALL 1408 XXXX XXXX XXXXX 2 OUTER SURFACE 0. 78 0.78 14 WINDOW 1 210 0. 15 0. 52 0.078 3 OUTER SHEATHING 0.00 0.00 15 WINDOW 2 42 0.03 0. 56 0.017 4 FRAMING 6.88 XXXXX 16 WINDOW 3 0 0.00 0. 60 0.000 5 CAVITY a)INSULATION XXXX 19.00 17 DOOR 1 40 0.03 0. 08 0.002 6 b)AIR SPACE XXXX 0.00 18 DOOR 2 0 0.00 0. 48 0.000 7 INSIDE SURFACE 0.45 0.45 19 DOOR 3 0 0.00 0.48 0.000 8 AIR FILM INSIDE 0. 68 0.68 20 OPAQUE WALL 1116 XXXX XXXX XXXXX 9 OTHER a) 0.00 0.00 21 FRAMING 167 0. 12 0. 11 0. 013 10 b) 0.00 0.00 22 CAVITY 949 0. 67 0.05 0.032 11 Rt=TOTAL LINES 1-10 8. 96 21.08 ------------------------------------------ 12 U=1/R TOTAL 0. 112 0.047 Uo=TOTAL LINES 14 TO 20 0. 142 -- ------------------------------------------------------------------------------- WALL 2 SYSTEM R VALUES R VALUES WALL 2 AREA AREA U Ux HEATING 0 FRAMING CAVITY HEATING (S. F. ) RATIO VALUE RATIO ----------------------------------------- --------------------------------------------- 1 AIR FILM OUTSIDE 0.00 0.00 13 GROSS WALL 0 XXXX XXXX XXXXX 2 OUTER SURFACE 0.00 0.00 14 WINDOW* 0 0.00 0.00 0.000 3 OUTER SHEATHING 0.00 0.00 15 DOOR* 0 0.00 0.00 0.000 4 FRAMING 0.00 XXXXX 16 OTHER 0 0.00 0.00 0.000 5 CAVITY a)INSULATION XXXX 0.00 17 OTHER 0 0.00 0.00 0.000 6 b)AIR SPACE XXXX 0.00 18 OPAQUE WALL 0 XXXX XXXX XXXXX 7 INSIDE SURFACE 0.00 0.00 19 FRAMING 0 0.00 0.00 0.000 8 AIR FILM INSIDE 0.00 0.00 20 CAVITY 0 0.00 0.00 0.000 9 OTHER a) 0.00 0.00 --------------------------------------------- 10 b) 0.00 0.00 21 Uo=TOTAL LINES 14 TO 20 0.000 11 Rt=TOTAL LINES 1-10 0.00 0.00 12 U=1/R TOTAL 0.000 0. 000 *INCLUDED IN WALL 1 . ---------------------------------------------------------------- WALL 3 SYSTEM R VALUES R VALUES WALL 3 AREA AREA U Ux HEATING 0 FRAMING CAVITY HEATING (S. F. ) RATIO VALUE RATIO ----------------------------------------- --------------------------------------------- 1 AIR FILM OUTSIDE 0.00 0.00 13 GROSS WALL 0 XXXX XXXX XXXXX 2 OUTER SURFACE 0.00 0.00 14 WINDOWS' 0 0.00 0.00 0.000 3 OUTER SHEATHING 0.00 0.00 15 DOOR* 0 0.00 0.00 0.000 4 FRAMING 0.00 XXXXX 16 OTHER 0 0.00 0.00 0.000 5 CAVITY a)INSULATION XXXX 0.00 17 OTHER 0 0.00 0. 00 0.000 6 b)AIR SPACE XXXX 0.00 18 OPAQUE WALL 0 XXXX XXXX XXXXX 7 INSIDE SURFACE 0.00 0.00 19 FRAMING 0 0.00 0.00 0.000 8 AIR FILM INSIDE 0.00 0.00 20 CAVITY 0 0.00 0.00 0.000 9 OTHER a) 0.00 0.00 --------------------------------------------- 10 b) 0.00 0.00 21 Uo=TOTAL LINES 14 TO 20 0.000 11 Rt=TOTAL LINES 1-10 0.00 0.00 12 U=1/R TOTAL 0.000 0.000 INCLUDED IN WALL 1 . Uo CALCULATIONS FOR ROOF STANFORD RESIDENCE ROOF 1 SYSTEM R VALUES R VALUES ROOF 1 AREA AREA U Ux HEATING 2 FRAMING CAVITY HEATING (S. F. ) RATIO VALUE RATIO ----------------------------------------- --------------------------------------------- 1 AIR FILM OUTSIDE 0. 61 0.61 13 GROSS ROOF 1680 XXXX XXXX XXXXX 2 OUTER SURFACE 0.00 0.00 14 SKYLIGHT 1 8 0.00 0. 60 0.003 3 OUTER SHEATHING 0.00 0.00 15 SKYLIGHT 2 0 0.00 0. 60 0.000 4 FRAMING 4.38 XXXXX 16 SCUPPER 0 0.00 0. 60 0.000 5 CAVITY a)INSULATION XXXX 38.00 17 OTHER 0 0.00 0. 00 0.000 6 b)AIR SPACE XXXX 0.00 18 OPAQUE ROOF 1672 XXXX XXXX XXXXX 7 INSIDE SURFACE 0. 56 0. 56 19 FRAMING 100 0.06 0. 16 0.010 8 AIR FILM INSIDE 0.61 0.61 20 CAVITY 1572 0.94 0.03 0.024 9 OTHER a) 0.00 0.00 --------------------------------------------- 10 b) 0.00 0.00 21 Uo=TOTAL LINES 14 TO 20 0.036 11 Rt=TOTAL LINES 1-10 6. 16 39.78 12 U=1/R TOTAL 0. 162 0.025 ---------------------------------------------- ROOF 2 SYSTEM R VALUES R VALUES ROOF 2 AREA AREA U Ux HEATING 0 FRAMING CAVITY HEATING (S. F. ) RATIO VALUE RATIO ----------------------------------------- --------------------------------------------- 1 AIR FILM OUTSIDE 0.00 0.00 13 GROSS ROOF 0 XXXX XXXX XXXXX 2 OUTER SURFACE 0.00 0.00 14 SKYLIGHT* 0 0.00 0.00 0.00 3 OUTER SHEATHING 0.00 0.00 15 SCUPPER* 0 0.00 0.00 0.00 4 FRAMING 0.00 XXXXX 16 OTHER 0 0.00 0.00 0.000 5 CAVITY a)INSULATION XXXX 0.00 17 OTHER 0 0.00 0.00 0.000 6 b)AIR SPACE XXXX 0.00 18 OPAQUE ROOF 0 XXXX XXXX XXXXX 7 INSIDE SURFACE 0.00 0.00 19 FRAMING 0 0.00 0.00 0.000 8 AIR FILM INSIDE 0.00 0.00 20 CAVITY 0 0.00 0.00 0.000 9 OTHER a) 0.00 0.00 --------------------------------------------- 10 b) 0.00 0.00 21 Uo=TOTAL LINES 14 TO 20 0.000 11 Rt=TOTAL LINES 1-10 0.00 0.00 12 U=1/R TOTAL 0.000 0.000 *INCLUDED IN ROOF 1. --------------------------------- ROOF 3 SYSTEM R VALUES R VALUES ROOF 3 AREA AREA U Ux HEATING 0 FRAMING CAVITY HEATING (S.F. ) RATIO VALUE RATIO ----------------------------------------- --------------------------------------------- 1 AIR FILM OUTSIDE 0.00 0.00 13 GROSS ROOF 0 XXXX XXXX XXXXX 2 OUTER SURFACE 0.00 0.00 14 SKYLIGHT* 0 0.00 0.00 0.000 3 OUTER SHEATHING 0.00 0.00 15 SCUPPER* 0 0.00 0.00 0.000 4 FRAMING 0.00 XXXXX 16 OTHER 0 0.00 0. 00 0.000 5 CAVITY a)INSULATION XXXX 0.00 17 OTHER 0 0.00 0.00 0.000 6 b)AIR SPACE XXXX 0.00 18 OPAQUE ROOF 0 XXXX XXXX XXXXX 7 INSIDE SURFACE 0.00 0.00 19 FRAMING 0 0.00 0.00 0.000 8 AIR FILM INSIDE 0.00 0.00 20 CAVITY 0 0.00 0.00 0.000 9 OTHER a) 0.00 0.00 --------------------------------------------- 10 b) 0.00 0.00 21 Uo=TOTAL LINES 14 TO 20 0.000 11 Rt=TOTAL LINES 1-10 0.00 0.00 12 U=1/R TOTAL 0.000 0.000 *INCLUDED IN ROOF 1. Uo CALCULATIONS FOR FLOORS STANFORD RESIDENCE FLOOR 1 SYSTEM R VALUES R VALUES FLOOR 1 AREA AREA U Ux HEATING 3 FRAMING CAVITY HEATING (S. F. ) RATIO VALUE RATIO ----------------------------------------- --------------------------------------------- 1 AIR FILM OUTSIDE 0.92 0.92 13 GROSS FLR. 380 XXXX XXXX XXXXX 2 OUTER SURFACE 0.00 0.00 14 OTHER 0 0.00 0.00 0.000 3 OUTER SHEATHING 0.00 0.00 15 OTHER 0 0.00 0.00 0.000 4 FRAMING 9.06 XXXXX 16 OTHER 0 0.00 0.00 0.000 5 CAVITY a)INSULATION XXXX 19.00 17 OTHER 0 0.00 0.00 0.000 6 b)AIR SPACE XXXX 0.00 18 OPAQUE FLR. 380 XXXX XXXX XXXXX 7 INSIDE SURFACE 0. 78 0.78 19 FRAMING 38 0. 10 0.08 0.008 8 AIR FILM INSIDE 0.92 0.92 20 CAVITY 342 0.90 0.04 0.040 9 OTHER a) 1/2 P.B. , 0.66 0.66 --------------------------------------------- 10 b) VINYL 0. 05 0.05 21 Uo=TOTAL LINES 14 TO 20 0.048 11 Rt=TOTAL LINES 1-10 12.39 22.33 12 U=1/R TOTAL 0.081 0. 045 -- ---------------------- FLOOR 2 SYSTEM R VALUES R VALUES FLOOR 2 AREA AREA U Ux HEATING 4 FRAMING CAVITY HEATING (S. F. ) RATIO VALUE RATIO ----------------------------------------- --------------------------------------------- 1 AIR FILM OUTSIDE 0. 92 0.92 13 GROSS FLR. 1600 XXXX XXXX XXXXX 2 OUTER SURFACE 0.00 0.00 14 OTHER 0 0.00 0.00 0.000 3 OUTER SHEATHING 0.00 0.00 15 OTHER 0 0.00 0.00 0.000 4 FRAMING 9.06 XXXXX 16 OTHER 0 0.00 0.00 0.000 5 CAVITY a)INSULATION XXXX 19.00 17 OTHER 0 0.00 0.00 0.000 6 b)AIR SPACE XXXX 0.00 18 OPAQUE FLR. 1600 XXXX XXXX XXXXX 7 INSIDE SURFACE 0. 78 0. 78 19 FRAMING 160 0. 10 0.07 0.007 8 AIR FILM INSIDE 0. 92 0. 92 20 CAVITY 1440 0. 90 0.04 0.037 9 OTHER a) 1/2 P.B. , 0.66 0. 66 --------------------------------------------- 10 b) CARPET 2.08 2.08 21 Uo=TOTAL LINES 14 TO 20 0.044 11 Rt=TOTAL LINES 1-10 14.42 24. 36 12 U=1/R TOTAL 0.069 0.041 FLOOR 3 SYSTEM R VALUES R VALUES FLOOR 3 AREA AREA U Ux HEATING 0 FRAMING CAVITY HEATING (S. F. ) RATIO VALUE RATIO ----------------------------------------- --------------------------------------------- 1 AIR FILM OUTSIDE 0.00 0.00 13 GROSS FLR. 0 XXXX XXXX XXXXX 2 OUTER SURFACE 0.00 0.00 14 OTHER 0 0.00 0.00 0.000 3 OUTER SHEATHING 0.00 0.00 15 OTHER 0 0.00 0.00 0.000 4 FRAMING 0.00 XXXXX 16 OTHER 0 0.00 0.00 0.000 5 CAVITY a)INSULATION XXXX 0.00 17 OTHER 0 0.00 0.00 0.000 6 b)AIR SPACE XXXX 0.00 18 OPAQUE FLR. 0 XXXX XXXX XXXXX 7 INSIDE SURFACE 0.00 0.00 19 FRAMING 0 0.00 0.00 0.000 8 AIR FILM INSIDE 0.00 0.00 20 CAVITY 0 0.00 0.00 0.000 9 OTHER a) 0.00 0.00 --------------------------------------------- 10 b) 0.00 0.00 21 Uo=TOTAL LINES 14 TO 20 0.000 11 Rt=TOTAL LINES 1-10 0.00 0.00 12 U=1/R TOTAL 0.000 0.000 -------------------------------------------------------------------------------------------- -------------------------------------------------------------------------------------------- RESIDENTIAL COMPONENT COMPARISON STANFORD RESIDENCE -------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------- ALLOWED AREA GR.AREA U VALUE Ux ACTUAL AREA GR.AREA U VAL. Ux RATIO ALLOWED RATIO RATIO ACTUAL RATIO ----------------------------------------------- ---------------------------------------- 22 FLOOR 1 380 0.075 0.055 0.004 22 FLOOR 1 380 0.075 0.048 0.004 FLOOR 2 1600 0. 316 0.055 0.017 FLOOR 2 1600 0. 316 0.044 0.014 FLOOR 3 0 0.000 0.055 0.000 FLOOR 3 0 0.000 0.000 0.000 ----------------------------------------------- ---------------------------------------- 23 ROOF 1 1680 0. 331 0.026 0.009 23 ROOF 1 1680 0. 331 0.036 0.012 ROOF 2 0 0.000 0.026 0.000 ROOF 2 0 0.000 0.000 0.000 ROOF 3 0 0.000 0.026 0.000 ROOF 3 0 0.000 0.000 0.000 ----------------------------------------------- ---------------------------------------- 24 WALL 1 1408 0. 278 0. 144 0.040 24 WALL 1 1408 0. 278 0. 142 0.039 WALL 2 0 0.000 0. 144 0.000 WALL 2 0 0.000 0.000 0.000 WALL 3 0 0.000 0. 144 0.000 WALL 3 0 0.000 0.000 0.000 ----------------------------------------------- ---------------------------------------- 25 TOTAL 5068 Ut ALLOWED 0.070 25 TOTAL 5068 Ut ACTUAL 0.069 THIS BUILDING CONFORMS TO CHAPTER 4 OF THE WASHINGTON STATE ENERGY CODE. HEAT LOSS CALCULATION AND HEATING SYSTEM SIZE STANFORD RESIDENCE ------------------------------------------------------------------------- ------------------------------------------------------------------------- COMPONENT AREA U VALUE DELTA T HEAT LOSS (Q=U A T) ------------------------------------------------------------------------- FLOOR 1 CAVITY 342 0.045 47 719.8 FLOOR 1 FRAMING 38 0.081 47 144. 1 FLOOR 2 CAVITY 1440 0.041 47 2778. 3 FLOOR 2 FRAMING 160 0.069 47 521 . 5 FLOOR 3 CAVITY 0 0.000 47 0.0 FLOOR 3 FRAMING 0 0.000 47 0.0 ROOF 1 CAVITY 1572 0.025 47 1856. 9 ROOF 1 FRAMING 100 0. 162 47 765.4 ROOF 2 CAVITY 0 0.000 47 0.0 ROOF 2 FRAMING 0 0.000 47 0.0 ROOF 3 CAVITY 0 0.000 47 0.0 ROOF 3 FRAMING 0 0.000 47 0.0 WALL 1 CAVITY 949 0.047 47 2115.0 WALL 1 FRAMING 167 0. 112 47 878. 1 WALL 2 CAVITY 0 0.000 47 0.0 WALL 2 FRAMING 0 0.000 47 0.0 WALL 3 CAVITY 0 0.000 47 0.0 WALL 3 FRAMING 0 0.000 47 0.0 WINDOW 1 210 0. 520 47 5132.4 WINDOW 2 42 0. 560 47 1105.4 WINDOW 3 0 0.600 47 0.0 DOOR 1 40 0.080 47 150.4 DOOR 2 0 0.480 47 0.0 DOOR 3 0 0.480 47 0.0 SKYLIGHT 1 8 0. 600 47 225. 6 SKYLIGHT 2 0 0.600 47 0.0 SKYLIGHT 3 0 0. 600 47 0.0 INFILTRATION =1 . 1xVxT 47 8582.2 ( RATE =1 .0 FOR DOORS AND 0. 5 FOR WINDOWS) SLAB AREA 0 @ 2 BTU/SF 47 0.0 SLAB EDGE 0 @ 11 BTU/SF 47 0.0 OTHER HEAT LOSS 47 OTHER HEAT LOSS 47 OTHER HEAT LOSS 47 OTHER HEAT LOSS 47 MISC. HEAT GAIN(PEOPLE,APPLIANCES, ETC. ) 47 -2200.0 OTHER HEAT GAIN 47 OTHER HEAT GAIN 47 OTHER HEAT GAIN 47 ------------------------------------------------------------------------- TOTAL HEAT LOSS 22775. 3 ------------------------------------------------------------------------- ------------------------------------------------------------------------- MAXIMUM HEATING SYSTEM SIZE @ 150%: ELECTRIC RESISTANCE: 10.0 KW OTHER: 34163 BTUH NOTES: 1 . WINDOW CRACK ESTIMATED AT 1 L. F./S. F. 2. DOOR INFILTRATION @ 1 CFM/S. F. ------------------------------------------------------------------------- ------------------------------------------------------------------------- PREPARED BY: FOSTER AND WILLIAMS ASSOCIATES, P.S. , ARCHITECTS ANALYST: LEN PROJECT: STANFORD RESIDENCE PROJECT NO. : 87-01-21 DATE: 4-27-87 INTENT: Washington State Energy Code Conformance. NOTE: THIS BUILDING WAS NOT DESIGNED BY FOSTER AND WILLIAMS ASSOCIATES. THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR STRUCTURAL INTEGRITY, NOR CODE COMPLIANCE BEYOND THIS ENERGY EVALUATION. SYSTEMS INCLUDED IN THIS PROJECT — ------------------------------------------------- FLOOR 1 (380 S. F. ) 2x8 JSTS. , R-19 INS. , 5/8 CDX, 1/2 P. B. , VINYL FLOOR 2 (1600 S. F. ) 2x8 JSTS. , R-19 INS. , 5/8 CDX, 1/2 P.B. , CARPET FLOOR 3 (0 S. F. ) ROOF 1 1680 S. F. 2x4 TRUSS R-38 INS. 5 8 G.W. B. ROOF 2 (0 S. F. ) ROOF 3 (0 S. F. ) WALL 1 (1408 S. F. ) 2x6 STUDS, R-19 INS. , 5/8 T-111 , 1/2 G.W. B. WALL 2 (0 S.F. ) WALL 3 (0 S. F. ) SKYLIGHT 1 : (8 S. F. ) U VALUE= 0.6 SKYLIGHT 2: (0 S. F. ) SKYLIGHT 3: (0 S. F. ) WINDOW 1 : (210 S. F. ) U VALUE= 0. 52 WINDOW 2: (42 S. F. ) U VALUE= 0. 56 WINDOW 3: (0 S. F. ) HEAT TYPE: ELECTRIC RESISTANCE HEATING ZONE: 1 BUILDING TYPE: RESIDENTIAL OUTSIDE WINTER DESIGN TEMPERATURE: 23 WINDOWS = 15. 5% OF GROSS FLOOR AREA