Loading...
HomeMy WebLinkAboutBLD92-1485 - BLD CD Environmental Health Review - 12/8/1992 ULU 0 'J 1992 U MASON COUNTY Permit No.BLD rI_ -- I LIB GENERAL SERVICES BUILDING PERMIT APPLICATION PLEASE PRINT #1 Owner Phone# T� 9 .Sd Site Address /3/ Te f L e /� 1 4 '� V QgyS7 City State G lq Zip Directions to Job Site T/� i- Q orJ /JP _-f.D F'C �I / y / � rn f leaf J`n a I6 -To/ f 5i a Owner Mailing Address &n City /— State /A/'Zz Zip Lien/Title Holder Sm}/ -_�_9_ ('r.a p Fv Address City State Zip #2 Contractor Name Contractor Reg # Address Expiration Date City State Zip Phone #3 If septic is located on project site, include reords. I f<O Connect to Septic? Public Water Supply- _Well 1�J (If residential, proof of potable water may be required.) #4 Parcel No. � ----__.__��.. -75 -G0sg I ' Legal Description S LA-QG'Tyc I ,191 12 1 ofp155�, ' #5 Building Square Footage: (existing/proposed) 1st Fl / 2nd F1 / 3rd F1 / Loft / Basement / Deck / #Bedrooms / -3 #Bathrooms_ i Garage / Carport / (Cir e: Attached or Detached?) Other sq ft #6 Use of building escribe work M n�ilr. #7 Type of Job: New Add Alt Repair Demolition Woodstove Re-roof Bulkhead Other Usc-U #8 Mobile Hmmg Information Model Year�� Make {d 1,000 Model Length_ Width 7 Y Serial No. OQe #Bedrooms ? #Bathrooms 'J Type of Heat #9IV y water on or adjacent to property: Saltwater Lake River IV Pond wetland Seasonal runoff Other PRESSURE DISTRIBUTION DESIGN WORKSHEET AND/OR CHECKLIST Computed by: B.J. ' s SEPTIC DESIGNS 445 Lost Hwy. West Bremerton, WA 98312 Designed for: Kurt & Kelly Rohr (Pressure Trench System) Street address: P.O. Box 2047 Silverdale, Wa. 98383 SITE CONDITIONS : # of Bedrooms - 3 Soil Type - Sandy Loam I . DESIGN THE DISTRIBUTION NETWORK 1 . Make Preliminary Determination of Trench/Bed Configuration. A. Daily design flow 360 .00 gals. Daily flow = ( # bedrooms ) X ( flow/bedrooms ) B. Application rate based on soil type = 0. 60 gpd/ft2 C. Required absorption area = 600. 00 ft2 Required absorption area (ft2 ) _ [Daily design flow (gpd) ] /[.Application rate (gpd/ft21 ] D. Selected trench or bed width = 3 .00 lin ft E. Total trench or bed length = 200 . 00 lin ft Trench or bed length (ft ) _ [Required area ( ft2 ) 1 /[Selected width (ft ) ] 2 . Select a Primary Network Configuration A. Lateral length 32. 83 ft Lac length ft = [Total trench/bed length ( ft ) - 0. 5 ft]/[# of laterals] B. Lateral spacing = 11 .00 ft C. Transport pipe length = 145 . 00 ft D. Transport pipe diameter = 2 .00 in E. Manifold length = 22. 00 ft F. Select an orifice spacing for this lateral 2 . 98 ft G. Calculate the number of orifices in this lateral 12.00 # of orifices in this lateral=