HomeMy WebLinkAboutBLD92-1485 - BLD CD Environmental Health Review - 12/8/1992 ULU 0 'J 1992 U MASON COUNTY Permit No.BLD rI_ -- I LIB
GENERAL SERVICES BUILDING PERMIT APPLICATION
PLEASE PRINT
#1 Owner Phone# T� 9 .Sd
Site Address /3/ Te f L e /� 1 4 '� V QgyS7
City
State G lq Zip
Directions to Job Site T/� i- Q orJ /JP _-f.D F'C
�I / y / � rn f leaf
J`n a I6 -To/ f 5i
a
Owner Mailing Address &n
City /— State /A/'Zz Zip
Lien/Title Holder Sm}/ -_�_9_ ('r.a p Fv
Address
City State
Zip
#2 Contractor Name Contractor Reg #
Address
Expiration Date
City State Zip Phone
#3 If septic is located on project site, include reords.
I
f<O Connect to Septic? Public Water Supply- _Well
1�J (If residential, proof of potable water may be required.)
#4 Parcel No. � ----__.__��.. -75 -G0sg I
' Legal Description S LA-QG'Tyc I ,191
12 1 ofp155�,
' #5 Building Square Footage: (existing/proposed)
1st Fl / 2nd F1 / 3rd F1 / Loft /
Basement / Deck / #Bedrooms / -3
#Bathrooms_
i Garage / Carport / (Cir e: Attached or Detached?)
Other sq ft
#6 Use of building escribe work M n�ilr.
#7 Type of Job: New Add Alt Repair Demolition
Woodstove Re-roof Bulkhead Other Usc-U
#8 Mobile Hmmg Information
Model Year�� Make {d 1,000 Model
Length_ Width 7 Y Serial No. OQe
#Bedrooms ? #Bathrooms 'J Type of Heat
#9IV y water on or adjacent to property: Saltwater Lake River
IV Pond wetland Seasonal runoff Other
PRESSURE DISTRIBUTION DESIGN WORKSHEET AND/OR CHECKLIST
Computed by: B.J. ' s SEPTIC DESIGNS
445 Lost Hwy. West
Bremerton, WA 98312
Designed for: Kurt & Kelly Rohr (Pressure Trench System)
Street address: P.O. Box 2047
Silverdale, Wa. 98383
SITE CONDITIONS : # of Bedrooms - 3
Soil Type - Sandy Loam
I . DESIGN THE DISTRIBUTION NETWORK
1 . Make Preliminary Determination of Trench/Bed Configuration.
A. Daily design flow 360 .00 gals.
Daily flow = ( # bedrooms ) X ( flow/bedrooms )
B. Application rate based on soil type = 0. 60 gpd/ft2
C. Required absorption area = 600. 00 ft2
Required absorption area (ft2 ) _
[Daily design flow (gpd) ] /[.Application rate (gpd/ft21 ]
D. Selected trench or bed width = 3 .00 lin ft
E. Total trench or bed length = 200 . 00 lin ft
Trench or bed length (ft ) _
[Required area ( ft2 ) 1 /[Selected width (ft ) ]
2 . Select a Primary Network Configuration
A. Lateral length 32. 83 ft
Lac length ft =
[Total trench/bed length ( ft ) - 0. 5 ft]/[# of laterals]
B. Lateral spacing = 11 .00 ft
C. Transport pipe length = 145 . 00 ft
D. Transport pipe diameter = 2 .00 in
E. Manifold length = 22. 00 ft
F. Select an orifice spacing for this lateral 2 . 98 ft
G. Calculate the number of orifices in this lateral 12.00
# of orifices in this lateral=