Loading...
HomeMy WebLinkAboutSWG2022-00435 - SWG As-Built - 10/12/2023 jte Mason County OSS Installation Report pg. 1 MASON COUNTY PUBLIC HEALTH APPLICANT/ PERMIT INFORMATION Permit Number SWG 2022-00435 _ Parcel # 32123-11-50020 Applicant Name David Stebor Subdivision (Name/Div/Block/Lot) Applicant Address P.O. Box 2297 City, State, Zip Silverdale, WA 98383 Installer Name Active Underground LLC Site Address 211 E Duramen Trail Designer Name Adam Hunter INSTALLATION CHECKLIST Q Full System Installation ❑Tank(s)Only ❑ Drainfield Only ❑Repair ❑ Other System Type Pressure Dist. Pretreatment Type >5 ft. from foundation? ❑ N/A ®YES ❑ NO >50 ft. from wells? . ❑ ® ❑ Z >50 ft. from surface water? ❑ 0 Ill F Cleanout between building and tank? - El ❑ a Tank baffles present? - ❑ 0 ❑ d 24"access risers over each compartment?- - ❑ 0 ❑ W Effluent filter installed?- - ❑ 0 ❑ d7 Septic tank capacity (working) 1200 gal Manufacturer SPS C D-box water level and speed levelers used? - - 0 N/A ❑ YES El NO oJ O Manifold/D-box accessible from surface?- - ❑ 0 ❑ m2 Check valves installed? ❑� ❑ ❑ oa 2 Transport Line Size 2 Schedule/Class 40 Bedrooms installed(check one) ❑ 2 1113 0 4 ❑ 5 ❑6 ❑Commercial/Other >10 ft. from foundation?- A ❑ N/A ® YES ❑ NO C >100 ft. from wells?- T \t ,,.i - - ❑ 0 ❑ W >100 ft. from surface water? - ❑ 0 ❑ tr. >10 ft. from potable water lines?- ❑ I ❑ _ > 5 ft. from property lines and easements?- ❑ ® 0 K > 30 ft. from downgradient curtain/foundation drains? ❑ 1.1 ❑ C Drainfield level and observation ports present - ❑ S ❑ ❑ Graveless chambers or El Clean gravel used? (check one) Proper cover installed over drainfield? ❑ 0 ❑ Pump tank setbacks consistent with septic tank? - - ❑ N/A 0 YES ❑ NO • Pump tank capacity (flood) 1250 gal Manufacturer SPS < 24" access riser(s)and accessible from surface? ❑ 0 ❑ aAlarm or Control Panel Installed? ❑ N.eds t=-red❑ 0 f Control Panel equipped with Timer/ ETM/Counter- - ❑ ® ❑ 7 a Pump installed in ❑ Bucket or ❑ On Block or 0 Other Pump silo w/intake holes 1 B"off floor a D Pump Make/Model Liberty 290 0 Floats or ❑ Transducer d Tank draw down 2.5 in/min Pump capacity 57 qpm Squirt Height 52" ft Pump on time 1min 10sec Pump off time 4hour Daily flow set at 360 gpd Ueda,ed Wa1Q018 Mason County OSS Installation Report pg. 2 Parcel# 32123-11-50020 ABANDONMENT RECORD Were existing septic components abandoned as part of this project? 0 YES Q NO If yes, please describe: Were all components pumped out and properly abandoned per WAC246-272A-0300? - - ❑ YES NO RECORD DRAWING This is a permanent record and must be accurate and descriptive enough to re-locate in the need of maintenance activities and future development Typical Record Drawings contain Dramfeld&manifold onentalmn&layout.Septic/pump lank location.Nosh arrow,reserve drainneld.existing and proposed buildings,prallm of wells,waterlines, wells,observation pods.cleanoun,and other maintenance access points. Incomplete Record Drawings may create additional delays in final Installation approval and related pemMs. Record Drawing Attached CERTIFICATION OF INSTALLATION INSTALLER DESIGNER/ENGINEER I certify that 1 installed the system in accordance with I certify that the system has been installed in accor- the septic design stamped"APPROVED"by Mason dance with the septic design stamped "APPROVED"by County Public Health and that any deviations shown Mason County Public Health and that any deviations here have been cleared/approved by both the designer shown here have been cleared/approved by both and Mason County Public Health and meet all State myself and Mason County Public Health and meet all and Mason County Codes. State and Mason County Codes I further certify that all information contained on this I further certify that all information contained on this form and at+at red Rec6rd Drawing-is accurate. form and attached Record Drawing is accurate. qinfig Signature of Installer ('+ Date r 011 I C P S ��Me< �{ L'Q\C r� Printed Name of Signee MASON COUNTY PUBLIC HEALTH r 'h1 The undersigned approves this Installation Report and f Record Drawing on behalf of Mason County Public it t Health: �s�.�..�.zs::.,•��:=• k12-17—P-A/l/t16141 �Q jl Z_h"25-S L� Signature of Environmental Health Specialist Date (stamp, signature and date) THIS FORM MAY BE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEB SITE Updated erztrzms Rhonda Thompson From: lim Hunter&Associates <jhandassociates@hotmail.com> Sent Wednesday, October 11, 2023 11:39 AM To: Rhonda Thompson Cc: James Medcalf; Adam Hunter Subject: Re: 5WG202 2-0043 5 Caution: External Email Warning!This email has originated from outside of the Mason County Network. Do not click links or open attachments unless you recognize the sender, are expecting the email, and know the content is safe. If a link sends you to a website where you are asked to validate using your Account and Password, DO NOT DO SO! Instead, report the incident. Hi Rhonda, This was a renewal of an expired design by another designer. I believe that the original design had the test holes and dra infield located incorrectly and that the dra infield location as installed was actually in the original test hole area. Adam On Oct 10, 2023,at 4:04 PM, Rhonda Thompson <RThompson@masoncountywa.gov>wrote: Thank you for this information. Adam do you have anything to add? Rhonda Thompson, RS Senior Environmental Health Specialist Mason County Public Health 415 N 6`h St. Shelton,WA 98584 360-427-9670 ext. 581 Rthompson@masoncountywa.gov From:lames Medcalf<jlm@activeundergroundllc.com> Sent:Tuesday, October 10, 2023 2:17 PM To: Rhonda Thompson<RThompson@masoncountywa.gov>; 'Adam Hunter' <adam.j.hunter@gmail.com>;1HANDASSOCIATES@HOTMAIL.COM Subject: RE: SWG2022-00435 Caution: External Email Warning!This email has originated from outside of the Mason County Network. Do not click links or open attachments unless you recognize the sender, are expecting the email, and know the content is safe. If a link sends you to a website where you are asked to validate using your Account and Password, DO NOT DO 501 Instead, report the incident. I've attached a couple of pictures of the evidence I found in area of dra infield placement during installation. 1 <image001.png> From: Rhonda Thompson Sent:Tuesday, October 10, 2023 1:06 PM To:Adam Hunter<adam.l.hunter(dkmail.com>; 1HANDASSOCIATES@HOTMAIL.COM• JLM@ACTIVEUNDERGROUNDLLC.COM Subject: SWG2022-00435 Hi Adam and James, I am pretty confused on this one. Parcel 32123-11-50020 for David Stebor at 211 E Duramen Trail. I got the complete asbuilt and am measuring the drainfield got installed over 100ft away from where the test holes were originally dug.... Is there any explanation here?The new design was already cutting it pretty close for conventional pressure 24"vertical separation with 6-8" excavation.Wendy Jonas in 2017 found 32" of vertical separation so there was really no wiggle room here. 100+ft is a huge distance from where the drainfield should have been installed.We will require new test holes to be dug around the newly installed system to verify soil depths. I would also guess that you connected that fourth lateral to the system but the record drawing doesn't show it. Attached are my measurements with a calibration to property lines in Bluebeam. Additional inspection fees/revision fees may apply. Thank you, Rhonda Thompson, RS Senior Environmental Health Specialist Mason County Public Health 415 N 6'h St.Shelton,WA 98584 360-427-9670 ext. 581 Rthompson@masoncourttywa.Rov 2 ii n X X X D m m m m y z z z \ 11 v CO No m m m _ 0 • n d L'Si o_ 00 ern / '% 'l m m a z - j m / A f� O 0 w� ��- 4ii m o -n m y w O l el _ - 9V Hump _ ,x tosI x SpN< vkFRp70/ p F flu air -7 O rJ .13 T 0. y r y i cm N O N N Cr co C x j O TO o rn z to < O n O mn a 2 _ i up co n I x to m z A a F• n (.. v • 0 O y. -IO 0 gC m o m � R. F '= ° w -nz pgj m N ° c Po 0 0 ® mcu T y ffl Y R. L Z Z m t� Z , N N Y - O o m (G O Ft s o ^ 7 V n m L m O m O zl m m y O Z m n N n m 5 • o O CI 4' O r m n @ p m o o m m n 7J • c r• m i m yc N 2 z " p A O C z O