HomeMy WebLinkAboutFIR2022-00042 - FIR Construction Plans (Blue Prints) - 3/8/2023Asio Mason Co Fire Marshal
WI Approved with Conditions
09/06/2022 3:24:32 PM
ki
r's‘r-"
CONDITIONS:
- A rough-in/bucket inspection/test shall be witnessed by this
office. Pipe insulation shall be in -place prior to inspection
- A final inspection shall be required
BEDROOM
#2
8-0
BATI-I ROOM
5-0
CLOSET
L
I 12
LAUNDRY
5-0
Br1JRO
#1
8-r
eAv
r
—
7-q
r
FLAT-CLG
SrP
I-1 6-0
co
r
DINING
7 ROOM
VAULTED
CLOSET
FLAT -CEILING
STA I R
DN
- LIV'R-1-NG
/ VAUM
LTED
2ND FLOOR FIRE SPRINKLER PLAN
SCALE: I/4"=11-0"
A
FPI:
GARAGE
OR
O
rn
O
e0
5-4
A
FPI
•
STAIR
UP
(H
1ST FLOOR FIRE SPRINKLER PLAN
\\,,,���
SCALE: I/4"=I'-0" \"`
CPVC PIPE
STAND-OFF HANGER AND
RESTRAINER.
TYCO FIG. 26
TRUSS
BOTTOM
CPVC PIPE
HANGER DETAILS
SCALE: N.T.S.
!7
I%
HYDRAULIC REMOTE AREA 111: KITCHEN/DINING ROOM
.05 GPM/SQ. FT. OVER MOST DEMANDING 2 HEADS
TOTAL DEMAND OF 2 SPRINKLERS CALCULATED
26.18 GPM AT 20.26 PSI AT THE BASE OF RISER
DOUBLE FASTENER
STRAP TYPE -SIDE MOUNT
34' THRU 2" CPVC PIPE
LJ
r-i
z
u
z
R RISER DETAIL
FPI SCALE: I/211=11-0"
TRUSS
BOTTOM
UNHEATED ATTIC AREA
CPVC SPRINKLER PIPE
CEILING) AIR SPACE
BUILDING INTERIOR
R-IIx2'-0" UNFACED BATT
INSULATION OVER THE
SPRINKLER PIPE -BY OTHERS
INSULATION DETAIL
SCALE: N.T.S.
L ;SET
ADDITIONAL BLOW
IN INSULATION PER
SPECIFICATIONS -
BY OTHERS
TRUSS CHORD
BEDROOM
Q
GARAGE
FIRE SPRINKLER SECTION
FPI SCALE: I/4"=1'-0"
VICINITY MAP
N.T.5.
SCOPE OF WORK:
KNIGHT FIRE PROTECTION, INC. TO INSTALL A NEW WET PIPE FIRE SPRINKLED
SYSTEM IN THE NEW RESIDENCE PER NFPA I3D.
DESIGN CRITERIA:
THE NFPA 13D SPRINKLER SYSTEM 15 DESIGNED AND HYDRAULICALLY CALCUL,
TO PROVIDE .05 GPM/SQ. FT. OVER THE MOST DEMANDING TWO SPRINKLERS
IN A SINGLE COMPARTMENT.
GENERAL NOTES:
1. WATER SOURCE IS A NEW 1-1H3-150C FIRE PUMP/TANK IN THE GARAGE.
2. KFP START POINT TO BE THE HH3-I50C PUMP/TANK PACKAGE.
3. MAXIMUM SPRINKLER SPACING IN COMPARTMENTS CONTAINING TWO OR MOR.
SPRINKLERS 15 16'xl6'; MAX 8' FROM WALLS. MAXIMUM SPRINKLER SPACING
COMPARTMENTS CONTAINING ONE SPRINKLER 15 I6'xl6'; MAX 8' FROM WALLS
4. ALL PIPE TO BE I" CPVC U.N.O.
5. ALL SPRINKLERS AND PIPE TO BE INSTALLED ACCORDING TO THEIR LISTIN(
G. MAXIMUM STANDARD CPVC HANGER SPACING TO BE AS FOLLOWS:
I" = 6'
IY41 = 6' -611
WASHINGTON STATE
CERTIFICATE OF COMPETENCY
FIRE PROTECTION SPRINKLER SYSTEMS
Joseph Aaron Pennell
3479-0220-B Level 2
Knight Fire Protection
KNIGHFP044LK
Signature
OHYDRAULIC NODE
GENERAL NC
REFER TO THE NFPA 13, 2
1. MATERIAL TO BE NEW
UL LISTED.
2. PIPING SMALL BE PER
3. EARTHQUAKE BRACING
PER NFPA 13.
4. JOINING OF PIPE AND I
THREADED, GROOVED,
AND WELDED SHALL BI
13.
5. PIPE HANGERS AND ME
HANGING TO BE PER N
6. PIPING DIMENSIONS AR
TO CENTER.
7. OWNER TO PROVIDE AI
HEAT TO PREVENT NA
PIPES FROM FREEZING
PROTECTED BY A WET
SPRINKLER SYSTEM.(M
REQUIRED)
5. ALL WIRING OF ELECTF
DEVICES TO BE BY OT
9. PAINTING OF PIPE AND
EQUIPMENT (IF REQUIR
OTHERS.
10. FURRING OF PIPE AND
(IF REQUIRED) BY OTI-
APPROVAL
MASON COUNTY
OWNER/ARCM TE
KN/GNT FIRE
TO
SPRINKLERS USED
SPRINKLER MAKE t MODEL
RELIABLE RES. PEND. CONCEALED
RELIABLE RES. PEND. CONCEALED
TYCO LFII RES. HSW SEMI -RECESS
S.I.N.
THREAD
SIZE
K SPRINKLER
FACTOR FINISH
FcrTTCFIE
FINISH
RA0616
I/2'
4.9
BRASS
WHITE
RA0616
1/2'
4.9
BRA55
WHITE
RA3533
I/2'
4.4
WHITE
WHITE
SYSTEM DEMAND
REQUIRED PRESSURE
28 p.s.i.
AVAILABLE PRESSURE
44 p.s.i.
TOTAL DEMAND 26 g.p.m.
HOSE N/A g.p.m.
STANDARD
WATER FLOW
STATIC PRESSURE
RESIDUAL PRESSURE
FLOW
DATE TESTED
DESIGN CRITERIA
HAZARD CLASSIFICATION:
NFPA 13D (2016)
RESIDENTIAL
MAX SQ. FT. / HEAD 256 DENSITY .05 GPM/
TYPE OF SYSTEM: WET
QUALITY CONTROL BY:
MK
DATE
BY
REVISIONS
512 SI
DATE:
CONTRACT WITH:
Tom Noble
P.O. Box 129
Long Beach, WA 98631
Jobsite Supt: Tom Noble
Phone: 909-37
CONTRACT NAME:
Noble Residence
835 N Hamma Ridge Dr.
Lilliwaup, WA 98555
KNIGHT FIRE PROTECTION
9702 LATHROP INDUSTRIAL E
OLYMPIA, WA 98512-9188
(360) 786-8606
24 NOUN A DAr
LICENSE NO. KNIGHFP044LK
DESIGNER
DATE
JOB NUMBER
Mark
Cantrell
8-15-22
22-066
FILE NAME,
22-088 Noble Residence