Loading...
HomeMy WebLinkAboutFIR2022-00042 - FIR Construction Plans (Blue Prints) - 3/8/2023Asio Mason Co Fire Marshal WI Approved with Conditions 09/06/2022 3:24:32 PM ki r's‘r-" CONDITIONS: - A rough-in/bucket inspection/test shall be witnessed by this office. Pipe insulation shall be in -place prior to inspection - A final inspection shall be required BEDROOM #2 8-0 BATI-I ROOM 5-0 CLOSET L I 12 LAUNDRY 5-0 Br1JRO #1 8-r eAv r — 7-q r FLAT-CLG SrP I-1 6-0 co r DINING 7 ROOM VAULTED CLOSET FLAT -CEILING STA I R DN - LIV'R-1-NG / VAUM LTED 2ND FLOOR FIRE SPRINKLER PLAN SCALE: I/4"=11-0" A FPI: GARAGE OR O rn O e0 5-4 A FPI • STAIR UP (H 1ST FLOOR FIRE SPRINKLER PLAN \\,,,��� SCALE: I/4"=I'-0" \"` CPVC PIPE STAND-OFF HANGER AND RESTRAINER. TYCO FIG. 26 TRUSS BOTTOM CPVC PIPE HANGER DETAILS SCALE: N.T.S. !7 I% HYDRAULIC REMOTE AREA 111: KITCHEN/DINING ROOM .05 GPM/SQ. FT. OVER MOST DEMANDING 2 HEADS TOTAL DEMAND OF 2 SPRINKLERS CALCULATED 26.18 GPM AT 20.26 PSI AT THE BASE OF RISER DOUBLE FASTENER STRAP TYPE -SIDE MOUNT 34' THRU 2" CPVC PIPE LJ r-i z u z R RISER DETAIL FPI SCALE: I/211=11-0" TRUSS BOTTOM UNHEATED ATTIC AREA CPVC SPRINKLER PIPE CEILING) AIR SPACE BUILDING INTERIOR R-IIx2'-0" UNFACED BATT INSULATION OVER THE SPRINKLER PIPE -BY OTHERS INSULATION DETAIL SCALE: N.T.S. L ;SET ADDITIONAL BLOW IN INSULATION PER SPECIFICATIONS - BY OTHERS TRUSS CHORD BEDROOM Q GARAGE FIRE SPRINKLER SECTION FPI SCALE: I/4"=1'-0" VICINITY MAP N.T.5. SCOPE OF WORK: KNIGHT FIRE PROTECTION, INC. TO INSTALL A NEW WET PIPE FIRE SPRINKLED SYSTEM IN THE NEW RESIDENCE PER NFPA I3D. DESIGN CRITERIA: THE NFPA 13D SPRINKLER SYSTEM 15 DESIGNED AND HYDRAULICALLY CALCUL, TO PROVIDE .05 GPM/SQ. FT. OVER THE MOST DEMANDING TWO SPRINKLERS IN A SINGLE COMPARTMENT. GENERAL NOTES: 1. WATER SOURCE IS A NEW 1-1H3-150C FIRE PUMP/TANK IN THE GARAGE. 2. KFP START POINT TO BE THE HH3-I50C PUMP/TANK PACKAGE. 3. MAXIMUM SPRINKLER SPACING IN COMPARTMENTS CONTAINING TWO OR MOR. SPRINKLERS 15 16'xl6'; MAX 8' FROM WALLS. MAXIMUM SPRINKLER SPACING COMPARTMENTS CONTAINING ONE SPRINKLER 15 I6'xl6'; MAX 8' FROM WALLS 4. ALL PIPE TO BE I" CPVC U.N.O. 5. ALL SPRINKLERS AND PIPE TO BE INSTALLED ACCORDING TO THEIR LISTIN( G. MAXIMUM STANDARD CPVC HANGER SPACING TO BE AS FOLLOWS: I" = 6' IY41 = 6' -611 WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Joseph Aaron Pennell 3479-0220-B Level 2 Knight Fire Protection KNIGHFP044LK Signature OHYDRAULIC NODE GENERAL NC REFER TO THE NFPA 13, 2 1. MATERIAL TO BE NEW UL LISTED. 2. PIPING SMALL BE PER 3. EARTHQUAKE BRACING PER NFPA 13. 4. JOINING OF PIPE AND I THREADED, GROOVED, AND WELDED SHALL BI 13. 5. PIPE HANGERS AND ME HANGING TO BE PER N 6. PIPING DIMENSIONS AR TO CENTER. 7. OWNER TO PROVIDE AI HEAT TO PREVENT NA PIPES FROM FREEZING PROTECTED BY A WET SPRINKLER SYSTEM.(M REQUIRED) 5. ALL WIRING OF ELECTF DEVICES TO BE BY OT 9. PAINTING OF PIPE AND EQUIPMENT (IF REQUIR OTHERS. 10. FURRING OF PIPE AND (IF REQUIRED) BY OTI- APPROVAL MASON COUNTY OWNER/ARCM TE KN/GNT FIRE TO SPRINKLERS USED SPRINKLER MAKE t MODEL RELIABLE RES. PEND. CONCEALED RELIABLE RES. PEND. CONCEALED TYCO LFII RES. HSW SEMI -RECESS S.I.N. THREAD SIZE K SPRINKLER FACTOR FINISH FcrTTCFIE FINISH RA0616 I/2' 4.9 BRASS WHITE RA0616 1/2' 4.9 BRA55 WHITE RA3533 I/2' 4.4 WHITE WHITE SYSTEM DEMAND REQUIRED PRESSURE 28 p.s.i. AVAILABLE PRESSURE 44 p.s.i. TOTAL DEMAND 26 g.p.m. HOSE N/A g.p.m. STANDARD WATER FLOW STATIC PRESSURE RESIDUAL PRESSURE FLOW DATE TESTED DESIGN CRITERIA HAZARD CLASSIFICATION: NFPA 13D (2016) RESIDENTIAL MAX SQ. FT. / HEAD 256 DENSITY .05 GPM/ TYPE OF SYSTEM: WET QUALITY CONTROL BY: MK DATE BY REVISIONS 512 SI DATE: CONTRACT WITH: Tom Noble P.O. Box 129 Long Beach, WA 98631 Jobsite Supt: Tom Noble Phone: 909-37 CONTRACT NAME: Noble Residence 835 N Hamma Ridge Dr. Lilliwaup, WA 98555 KNIGHT FIRE PROTECTION 9702 LATHROP INDUSTRIAL E OLYMPIA, WA 98512-9188 (360) 786-8606 24 NOUN A DAr LICENSE NO. KNIGHFP044LK DESIGNER DATE JOB NUMBER Mark Cantrell 8-15-22 22-066 FILE NAME, 22-088 Noble Residence