GENERAL NOTES:
ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE 1997 UNIFORM BUILDING -
CODE, AND ANY OTHER GROVENING CODES AS ADOPTED BY PIERCE COUNTY.
VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO ANY CONSTRUCTION.
SUBSTITUTION OF MATERIALS AS -APPROVED PER UBC.
SOLID BEARING':SOJL ASSUMED TO_;BE 2000 PSI.
FOOTINGS TO BEAR ON UNDISTURBED`SOIL, DEVOID OF ANY ORGANIC MATERIAL. •
CONCRETE TO DEVELOP A MINIMUM OF 2500 PSI AT 28 DAYS WITH A FIVE (5) SACK
CEMENT PER YARD, AND A:MINIMUM SLUMP OF 4".
REINFORCEMENT STEEL TO BE GRADE 40 MINIMUM.
ALL WOOD IN CONTACT WITH EARTH OR CONCRETE SHALL BE TREATED WOOD OR
FOUNDATION REDWOOD; ALL MARKED OR. BRANDED BY AN APPROVED AGENCY.
DRAINAGE PROVISIONS SHALL BE MADE FOR THE CONTROL OF SUFACE WATER AROUND
THE BUILDING.
LUMBER REQUIREMENTS PER DRAWINGS !: LYWOOD OR OSB SHALL BE APA-APPROVED
AND INDEX NOTED.
WINDOWS TO BE PER PLAN.
INSULATION REQUIREMENTS:
FLOORS R-30
WALLS R 2.1 MIN.
ROGER 38 MIN.
FASTENERS `SHALL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS AND TO MEET
UBC SECTION _25,.TABLE.23-I-Q.
BOARDLUMBER SHALL NOT EXCEED 19% MOISTURE CONTENT AT THE TIME OF
INSPECTION FOR WALL BOARD INSTALLATION:
DESIGN CRITERIA:
WIND 80 MPH
EXPOSURE B
SEISMIC 3
SNOW LOAD 25.PSF
FLOOR LOAD 40
SCOPE:
THE PROVISIONS OF THE 1997 UNIFORM BUii.DING CODE SHALL APPLY TO THE
CONSTRUCTION OF THIS PROJECT. WHERE THERE IS A CONFLICT BETWEEN A GENERAL
REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL BE
APPLICABLE, AS WELL AS ALL ENGINEERING: REQUIREMENTS. •
THE PURPOSE OF THIS CODE IS TO PROVIDE IAi VIMUM STANDARDS TO SAFEGUARD LIFE
OR. LIMB, HEALTH, PROPERTY AND PUBLIC WELFARE BY REGULATING AND
CONTROLLING THE DESIGN, CONSTRUCTION QUALITY OF 1vIATERIALS,-USEE AND
OCCUPANCY, LOCATION AND MAINTENANCE OF ALL BUILDINGS AND STRUCTURES
WITHIN THIS JURISDICTION.
THESE DRAWINGS. HAVE BEEN PREPARED Te MEET THE MINIMUM STANDARDS OF THE 1997 EDITION OF
THE UNIFORM BUILDING CODE: -.LOCAL ORD)h 4NCES AND REGULATIONS. MAY IMPOSE ADDITIONAL
REQUIREMENTS: THE BUILDER SHALL IDEN Ir Y ANY: ADDITIONAL. REQUIREMENTS BEFORE
COMMENCING WORK AND SHALL VERIFY Al.I: DIMENSIONS AND CONDITIONS AT I'm .SITE DURING THE
EXECUTION OF. THE PROJECT. ANY ERRORS. OR OMISSIONS FOUNT? ON.THE DRAWINGS. SHALL BE
BROUGHT TO THE ATTENTION OF THE DESIGR PRIOR. TO COMMENCING ANY. WORK. THESE PLANS
HAVE BEEN PREPARED TO REPRESENT THE INTENT CIF THE FINISHED STRUCTURAL AND FUNCTIONAL.
CONFIGURATION OF THE BUILDING THE METHODS CHOSEN TO MEET THIS INTENT.ARE TH$:'
RESPONSIBILITY OF: THE OWNER OR BUILDER_ THE DESIGNER. MAKES ,NO WARRANTIES, EITHER
EXPRESSED OR IMPLIED AND ASSUMES NO LIABILITY FOR ERRORS AT THE SITE>IN:THE USE OF THESE
DRAWINGS.